Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

New Measurements of the Li, Be, and B Isotopes as a Test of Cosmic Ray Transport Models

Precise measurements of predominantly secondary cosmic-ray Li, Be, and B together with current well-measured production cross-sections for these isotopes help to improve our understanding of galactic cosmic ray propagation models. The Cosmic Ray Isotope Spectrometer (CRIS) on ACE has been measuring isotopic composition of cosmic rays since 1997 with high statistical precision. We present the isotopic abundances from CRIS and discuss these observations in the context of cosmic-ray transport models and previous cosmic-ray measurements.

deNolfo, Georgia A.↗

2-Micron Laser Transmitter for Coherent CO2 DIAL Measurement

Carbon dioxide (CO2) has been recognized as one of the most important greenhouse gases. It is essential for the study of global warming to accurately measure the CO2 concentration in the atmosphere and continuously record its variation. A high repetition rate, highly efficient, Q-switched 2-micron laser system as the transmitter of a coherent differential absorption lidar for CO2 measurement has been developed in NASA Langley Research Center. This laser system is capable of making a vertical profiling of CO2 from ground and column measurement of CO2 from air and space-borne platform. The transmitter is a master-slave laser system. The master laser operates in a single frequency, either on-line or off-line of a selected CO2 absorption line. The slave laser is a Q-switched ring-cavity Ho:YLF laser which is pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz. The injection seeding success rate is from 99.4% to 99.95%. For 1 kHz operation, the output pulse energy is 5.5mJ with the pulse length of ~50 ns. The optical-to-optical efficiency is 39% when the pump power is 14.5W. A Ho:YLF laser operating in the range of 2.05 micrometers can be tuned over several characteristic lines of CO2 absorption. Experimentally, a diode pumped Ho:Tm:YLF laser has been successfully used as the transmitter of coherent differential absorption lidar for the measurement of CO2 with a repetition rate of 5 Hz and pulse energy of 75 mJ. For coherent detection, high repetition rate is required for speckle averaging to obtain highly precise measurements. However, a diode pumped Ho:Tm:YLF laser can not operate in high repetition rate due to the large heat loading and up-conversion. A Tm:fiber laser pumped Ho:YLF laser with low heat loading can operate in high repetition rate. A theoretical model has been established to simulate the performance of Tm:fiber laser pumped Ho:YLF lasers. For continuous wave (CW) operation, high pump intensity with small beam size is suitable for high efficiency. For Q-switched operation, the optimal energy extraction relies on the pump intensity, pump volume, and pump duration which is inversely proportion to the repetition rate. CW and Q-switched Ho:YLF lasers with different linear cavity configurations have been designed and demonstrated for a 30 W Tm:fiber pump laser. The CW Ho laser slope efficiency and optical-to-optical efficiencies reach 65% and 55%, respectively. The pulsed laser efficiency depends on the repetition rate. For 1 kHz operation, the optical-to-optical efficiency is 39% when the pump power is 14.5W. Currently, the injection seeding success rate is between 99.4% and 99.95%. After a ten thousand pulses, the standard deviation of the laser frequency jitter is about 3 MHz. It meets the requirements of highly precise CO2 concentration measurement. In conclusion, an injection seeded, high repetition rate, Q-switched Ho:YLF laser has been developed for a coherent CO2 differential absorption lidar. This master-slave laser system has high optical-to-optical efficiency and seeding success rate. It can potentially meet the requirements of the coherent detection of CO2 concentration by a differential absorption lidar technique.

Singh, Upendra N.↗

Measuring ground movement in geothermal areas of Imperial Valley, California

Significant ground movement may accompany the extraction of large quantities of fluids from the subsurface. In Imperial Valley, California, one of the potential hazards of geothermal development is the threat of both subsidence and horizontal movement of the land surface. Regional and local survey nets are being monitored to detect and measure possible ground movement caused by future geothermal developments. Precise measurement of surface and subsurface changes will be required to differentiate man-induced changes from natural processes in this tectonically active region.

Lofgren, B. E.↗

On the determination of atmospheric path length by passive microwave radiometer

Microwave radiometer techniques were evaluated for use in atmospheric path length correction of Pacific Plate Motion Experiment interferometer measurements. It is shown that passive microwave radiometry allows precise measurement of the brightness temperature of the sky. It is also noted that the technological requirements of radiometers are very different from the requirements of radio astronomy. The technology was used in the construction of radiometers which are sufficient for use in the path length correction problem. A simulation study shows that, when combined with surface meteorology data, passive microwave radiometer data would allow a determination of the path length correction to better than 2 cm at the zenith. By a careful choice of frequencies, a dual frequency system would allow a measurement of the path length correction to better than 4 cm at zenith angles as great as 60 deg. Because of the wide range of weather conditions to be expected for the PPME sites (which include Alaska, Hawaii and Massachusetts), it will probably be necessary to use a separate correction algorithm for each site.

Webster, W. J., Jr.↗

Superconducting gravimeter

The superconducting gravimeter was developed and applied to field measurements. The stability of the instrument yielded the highest precision measurements of the Earth tides ever attained. It revealed unprecedented details about the effect of the atmosphere on gravity. Secular variations in gravity and the stability of the instruments were measured by comparing records from co-located instruments. These efforts have resulted in substantial reductions in the noise level at very low frequencies so that the peak differences between two instruments at the same location can be reduced to 0.1 micron gal.

Goodkind, J. M.↗

L-band Dielectric Constant Measurements of Seawater (Oral presentation and SMOS Poster)

This paper describes a resonant cavity technique for the measurement of the dielectric constant of seawater as a function of its salinity. Accurate relationships between salinity and dielectric constant (which determines emissivity) are needed for sensor systems such as SMOS and Aquarius that will monitor salinity from space in the near future. The purpose of the new measurements is to establish the dependence of the dielectric constant of seawater on salinity in contemporary units (e.g. psu) and to take advantage of modern instrumentation to increase the accuracy of these measurements. The measurement device is a brass cylindrical cavity 16cm in diameter and 7cm in height. The seawater is introduced into the cavity through a slender glass tube having an inner diameter of 0.1 mm. By assuming that this small amount of seawater slightly perturbs the internal fields in the cavity, perturbation theory can be employed. A simple formula results relating the real part of the dielectric constant to the change in resonant frequency of the cavity. In a similar manner, the imaginary part of the dielectric constant is related to the change in the cavity s Q. The expected accuracy of the cavity technique is better than 1% for the real part and 1 to 2% for the imaginary part. Presently, measurements of methanol have been made and agree with precision measurements in the literature to within 1% in both real and imaginary parts. Measurements have been made of the dielectric constant of seawater samples from Ocean Scientific in the United Kingdom with salinities of 10, 30, 35 and 38 psu. All measurements were made at room temperature. Plans to make measurements at a range of temperatures and salinities will be discussed.

Lang, Roger H.↗

First Measurement of the Cross-Correlation of CMB Lensing and Galaxy Lensing

We measure the cross-correlation of cosmic microwave background (CMB) lensing convergence maps derived from Atacama Cosmology Telescope data with galaxy lensing convergence maps as measured by the Canada-France-Hawaii Telescope Stripe 82 Survey. The CMB-galaxy lensing cross power spectrum is measured for the first time with a significance of 4.2σ, which corresponds to a 12% constraint on the amplitude of density fluctuations at redshifts ∼0.9. With upcoming improved lensing data, this novel type of measurement will become a powerful cosmological probe, providing a precise measurement of the mass distribution at intermediate redshifts and serving as a calibrator for systematic biases in weak lensing measurements.

CMB-galzxy lensing cross power spectrum↗

First Measurement of the Cross-Correlation of CMB Lensing and Galaxy Lensing

We measure the cross-correlation of cosmic microwave background lensing convergence maps derived from Atacama Cosmology Telescope data with galaxy lensing convergence maps as measured by the Canada-France-Hawaii Telescope Stripe 82 Survey. The CMB-galaxy lensing cross power spectrum is measured for the first time with a significance of 3.2σ, which corresponds to a 16% constraint on the amplitude of density fluctuations at redshifts ~ 0.9. With upcoming improved lensing data, this novel type of measurement will become a powerful cosmological probe, providing a precise measurement of the mass distribution at intermediate redshifts and serving as a calibrator for systematic biases in weak lensing measurements.

Hand, Nick↗

Velocity Measurements in the Wake of the Swept Wing Flow Test Model at the National Transonic Facility

Femtosecond laser electronic excitation tagging (FLEET) was applied to obtain flowfield velocity data for the Swept Wing Flow Test (SWiFT) at the NASA Langley Research Center National Transonic Facility (NTF). Despite numerous challenges associated with performing flow velocimetry measurements within a large-scale cryogenic wind tunnel facility, the experimental campaign was conducted under various conditions, including dry air at 320 K, cool nitrogen at 240 K, and Mach numbers of 0.2 and 0.8. FLEET velocimetry measurements were performed in the downstream wake of the SWiFT model, providing a quantitative dataset. This dataset includes one-dimensional velocity profiles and two-dimensional velocity maps acquired at different angles of attack and Reynolds numbers. The two-dimensional single component velocity maps indicate relatively uniform flow across the 120-mm wide wake flow survey suggesting that the main flow features can be represented by single-position linear velocity profiles. The measured instantaneous velocity profiles at variable angles of attack are compared to model lift coefficient information obtained at Mach 0.2. At high Reynolds numbers, a sudden velocity decrease was observed in the FLEET measurements at the same time as stall in lift coefficient was observed. At a low Reynolds number, both the velocity profiles and the lift coefficient show a smoother transition, without a sudden stall. Furthermore, the two-dimensional, one component velocity map reveals a velocity deficit region at Mach 0.8 at various angles of attack. Both single shot and mean velocity measurements were acquired allowing assessment of flowfield fluctuations and measurement precisions. The uncertainties are within 4 m/s in mean measurements based on repeatability data and about 5 m/s in instantaneous single-shot measurements. Measurements are reported with ~4.8 mm spatial resolution with 32-pixel averaging used to reduce measurement errors.

femtosecond↗

Velocity Measurements in the Wake of the Swept Wing Flow Test (SWIFT) Model at the National Transonic Facility

Femtosecond laser electronic excitation tagging (FLEET) was applied to obtain flowfield velocity data for the Swept Wing Flow Test (SWiFT) at the NASA Langley Research Center National Transonic Facility (NTF). Despite numerous challenges associated with performing flow velocimetry measurements within a large-scale cryogenic wind tunnel facility, the experimental campaign was conducted under various conditions, including dry air at 320 K, cool nitrogen at 240 K, and Mach numbers of 0.2 and 0.8. FLEET velocimetry measurements were performed in the downstream wake of the SWiFT model, providing a quantitative dataset. This dataset includes one-dimensional velocity profiles and two-dimensional velocity maps acquired at different angles of attack and Reynolds numbers. The two-dimensional single component velocity maps indicate relatively uniform flow across the 120-mm wide wake flow survey suggesting that the main flow features can be represented by single-position linear velocity profiles. The measured instantaneous velocity profiles at variable angles of attack are compared to model lift coefficient information obtained at Mach 0.2. At high Reynolds numbers, a sudden velocity decrease was observed in the FLEET measurements at the same time as stall in lift coefficient was observed. At a low Reynolds number, both the velocity profiles and the lift coefficient show a smoother transition, without a sudden stall. Furthermore, the two-dimensional, one component velocity map reveals a velocity deficit region at Mach 0.8 at various angles of attack. Both single shot and mean velocity measurements were acquired allowing assessment of flowfield fluctuations and measurement precisions. The uncertainties are within 4 m/s in mean measurements based on repeatability data and about 5 m/s in instantaneous single-shot measurements. Measurements are reported with ~4.8 mm spatial resolution with 32-pixel averaging used to reduce measurement errors.

Transonic↗

Measurements of I-129 in meteorites and lunar rock by tandem accelerator mass spectrometry

Precise measurements of the half-life of I-129 in three different meteorites and one lunar surface rock are reported. The meteorite source of I-129 was produced by cosmic ray secondary neutron reactions on Te, while the source in lunar materials in spallation on barium and rare earth elements. The Abee, Allende, and Dhajala meteorites were examined, together with the lunar rock 14310. Details of the process used to extract the iodine are provided. The Abee and Allende samples exhibited a production of 0.5 atom/min per gm of Te from the (n,2n) reaction and 0.05 atom/min/gm for the (n,gamma) reaction. The I-129 is concluded to be a viable tool for long-lived cosmogenic nuclide studies. Further work to extend the data to include the constancy of the cosmic ray flux, the meteorite bombardment history, and the cosmic exposure age dating by means of the I-129 and Xe-129 method is indicated.

Nizhiizumi, K.↗

Measuring Large Circumferences More Precisely

Optoelectromechanical gauge measures circumference of large object with resolution of 10 to the negative 4th power inches. Measuring wheel held by spring against cylindrical surface to be measured. Laser reader detects code marks on side of wheel. Marks indicate distance traveled around circumference. Measures inside or outside circumference. Also measures distance between two marks on edge of plate or along beam or track.

Moore, Louis E.↗

Description of the dedicated gravitational satellite mission /Gravsat/

A description of the dedicated gravitational satellite (Gravsat) mission is presented. Scientific objectives are to substantially improve knowledge of solid earth geophysics and oceanography by determining a more accurate geopotential. The most stringent requirement is determination of mean gravity anomalies over regions 100-km square to an accuracy of 2.5 mgal (1 gal = 1 cm/s squared). Fundamental geodetic data will be satellite-to-satellite measurement of relative range rate. Orbital characteristics are discussed. An error budget is presented which indicates that the requisite measurement precision can be achieved by closed-loop RF doppler measurements. Implicit in the discussion of the error budget is a description of the spacecraft and systems components.

Pisacane, V. L.↗

TLRS-3 system upgrades

This presentation describes the upgrades to the Transportable Laser Ranging Systems serial number three (TLRS-3), and the impact that these upgrades will have on the TLRS-3 performance in the field. The four major areas of system upgrades are the HP-380 computer, the Optical Attenuation Mechanism (OAM), the upgraded spatial, spectral and temporal filtering for improved daylight ranging capability, and the software upgrade to enable the system to track the Etalon satellites. The TLRS-3 was returned to the Goddard Geophysical and Astronomical Observatory (GGAO) in December 1991 for system upgrades in preparation of the TOPEX/POSEIDON campaign scheduled to begin in the summer of 1992. Many system upgrades were incorporated into the system while interleaving planned facility maintenance making TLRS-3 a more versatile and more dependable laser ranging system. The TLRS-3 was initially baselined with the MOBLAS-7 via simultaneous satellite ranging on the LAGEOS, Ajisai, Starlette, and ERS-I satellites. During the upgrades and following completion of the system upgrades intercomparisons with the MOBLAS-7 were made to verify the integrity and accuracy of the system changes. Several other groups of personnel participated in the TLRS-3 upgrade and they are: the Survey Section, the Precision Measurement Equipment Laboratory, the Architectural and Engineering Services Department, the Precision Timing Section, and the station personnel at TLRS-3 and MOBLAS-7.

Eichinger, Richard↗

Novel Estimation of Pilot Performance Characteristics

Two mechanisms internal to the pilot that affect performance during a tracking task are: 1) Pilot equalization (i.e. lead/lag); and 2) Pilot gain (i.e. sensitivity to the error signal). For some applications McRuer's Crossover Model can be used to anticipate what equalization will be employed to control a vehicle's dynamics. McRuer also established approximate time delays associated with different types of equalization - the more cognitive processing that is required due to equalization difficulty, the larger the time delay. However, the Crossover Model does not predict what the pilot gain will be. A nonlinear pilot control technique, observed and coined by the authors as 'amplitude clipping', is shown to improve stability, performance, and reduce workload when employed with vehicle dynamics that require high lead compensation by the pilot. Combining linear and nonlinear methods a novel approach is used to measure the pilot control parameters when amplitude clipping is present, allowing precise measurement in real time of key pilot control parameters. Based on the results of an experiment which was designed to probe workload primary drivers, a method is developed that estimates pilot spare capacity from readily observable measures and is tested for generality using multi-axis flight data. This paper documents the initial steps to developing a novel, simple objective metric for assessing pilot workload and its variation over time across a wide variety of tasks. Additionally, it offers a tangible, easily implementable methodology for anticipating a pilot's operating parameters and workload, and an effective design tool. The model shows promise in being able to precisely predict the actual pilot settings and workload, and observed tolerance of pilot parameter variation over the course of operation. Finally, an approach is proposed for generating Cooper-Harper ratings based on the workload and parameter estimation methodology.

Human pilot models↗

Fundamental study on gas monitoring in CELSS

A mass spectrometer and computer system was developed for conducting a fundamental study on gas monitoring in a Controlled Ecological Life Support System. Respiration and metabolism of the hamster and photosynthesis of the Spirulina were measured in a combination system consisting of a hamster chamber and a Spirulina cultivator. They are connected through a membrane gas exchanger. Some technical problems were examined. In the mass spectrometric gas monitoring, a simultaneous multisample measurement was developed by employing a rotating exchange valve. Long term precise measurement was obtained by employing an automatic calibration system. The membrane gas sampling probe proved to be useful for long term measurement. The cultivation rate of the Spirulina was effectively changed by controlling CO2 and light supply. The experimental results are helpful for improving the hamster-spirulina system.

Nishi, I.↗

Electromechanical Nerve Stimulator

Nerve stimulator applies and/or measures precisely controlled force and/or displacement to nerve so response of nerve measured. Consists of three major components connected in tandem: miniature probe with spherical tip; transducer; and actuator. Probe applies force to nerve, transducer measures force and sends feedback signal to control circuitry, and actuator positions force transducer and probe. Separate box houses control circuits and panel. Operator uses panel to select operating mode and parameters. Stimulator used in research to characterize behavior of nerve under various conditions of temperature, anesthesia, ventilation, and prior damage to nerve. Also used clinically to assess damage to nerve from disease or accident and to monitor response of nerve during surgery.

Tcheng, Ping↗