Magnetic Compensation For Gravitational Pressure Gradient

In technique for partial simulation of low gravitation in diamagnetic or paramagnetic liquid, magnetic field having suitable gradient produces force counteracting gravitational force. Technique makes possible to perform low-gravity experiments on ground, at considerably less expense than in outer space.

Israelsson, Ulf E.↗

Development of a High-Pressure Gaseous Burner for Calibrating Optical Diagnostic Techniques

In this work-in-progress report, we show the development of a unique high-pressure burner facility (up to 60 atm) that provides steady, reproducible premixed flames with high precision, while having the capability to use multiple fuel/oxidizer combinations. The highpressure facility has four optical access ports for applying different laser diagnostic techniques and will provide a standard reference flame for the development of a spectroscopic database in high-pressure/temperature conditions. Spontaneous Raman scattering (SRS) was the first diagnostic applied, and was used to successfully probe premixed hydrogen-air flames generated in the facility using a novel multi-jet micro-premixed array burner element. The SRS spectral data include contributions from H2, N2, O2, and H2O and were collected over a wide range of equivalence ratios ranging from 0.16 to 4.9 at an initial pressure of 10-atm via a spatially resolved point SRS measurement with a high-performance optical system. Temperatures in fuel-lean to stoichiometric conditions were determined from the ratio of the Stokes to anti-Stokes scattering of the Q-branch of N2, and those in fuel-rich conditions via the rotational temperature of H2. The SRS derived temperatures using both techniques were consistent and indicated that the flame temperature was approximately 500 K below that predicted by adiabatic equilibrium, indicating a large amount of heat-loss at the measurement zone. The integrated vibrational SRS signals show that SRS provides quantitative number density data in high-pressure H2-air flames.

Kojima, Jun↗

Atmospheric pressure chemical ionization studies of non-polar isomeric hydrocarbons using ion mobility spectrometry and mass spectrometry with different ionization techniques

The ionization pathways were determined for sets of isomeric non-polar hydrocarbons (structural isomers, cis/trans isomers) using ion mobility spectrometry and mass spectrometry with different techniques of atmospheric pressure chemical ionization to assess the influence of structural features on ion formation. Depending on the structural features, different ions were observed using mass spectrometry. Unsaturated hydrocarbons formed mostly [M - 1]+ and [(M - 1)2H]+ ions while mainly [M - 3]+ and [(M - 3)H2O]+ ions were found for saturated cis/trans isomers using photoionization and 63Ni ionization. These ionization methods and corona discharge ionization were used for ion mobility measurements of these compounds. Different ions were detected for compounds with different structural features. 63Ni ionization and photoionization provide comparable ions for every set of isomers. The product ions formed can be clearly attributed to the structures identified. However, differences in relative abundance of product ions were found. Although corona discharge ionization permits the most sensitive detection of non-polar hydrocarbons, the spectra detected are complex and differ from those obtained with 63Ni ionization and photoionization. c. 2002 American Society for Mass Spectrometry.

Non-NASA Center↗

Solar occultation sounding of pressure and temperature using narrowband radiometers

A technique for simultaneously retrieving pressure and temperature profiles using satellite-based narrowband radiometer measurements of absorption in the CO2 4.3-micron band is described. Pressure and temperature profiles for earth's upper atmosphere on a global scale can be obtained with errors less than 3% and 3 K, respectively. The p-T information can be used not only for improving the accuracy of inverted gas concentrations in the same absorption experiment but also for investigating the upper atmosphere circulation.

Park, J. H.↗

Spectroscopic Measurement Of Temperature And Pressure of O(2)

Spectroscopic technique useful in measuring temperature and pressure of oxygen in laboratory experiments involving high temperatures and/or high pressures. Devised for use in experiments in which oxygen or gas containing oxygen subjected to sudden adiabatic compression, as in shock tube. Also useful in combustion experiments and other experiments in which gaseous oxygen plays role.

Tapphorn, Ralph M.↗

Internal voltage control of hydrogen-oxygen fuel cells: Feasibility study

An experimental study was conducted to assess the feasibility of internal voltage regulation of fuel cell systems. Two methods were tested. In one, reactant partial pressure was used as the voltage control parameter and in the other reactant total pressure was used for control. Both techniques were breadboarded and tested on a single alkaline-electrolyte fuel cell. Both methods were found to be possible forms of regulation, however, of the two the total pressure technique would be more efficient, simpler to apply and would provide better transient characteristics.

Prokopius, P. R.↗

A pressure based method for the solution of viscous incompressible turbomachinery flows

A new technique was developed for the solution of the incompressible Navier-Stokes equations. The numerical technique, derived from a pressure substitution method (PSM), overcomes many of the deficiencies of the pressure correction method. This technique allows for the direct solution of the actual pressure in the form of a Poisson equation which is derived from the pressure weighted substitution of the full momentum equations into the continuity equation. Two dimensional internal flows are computed with this method. The prediction of cascade performance is presented. The extention of the pressure correction method for the solution of three dimensional flows is also presented.

Hobson, Garth Victor↗

Impeller response calculation due to complex pressure loading

An analysis technique is described to calculate the harmonic response of the first-stage impeller of the Space Shuttle Main Engine high pressure fuel turbopump. The excitation is a complex pressure loading at various locations on the impeller blades. The pressure loading was predicted using computational fluid dynamic techniques and was given as a Fourier series at 48 different locations on each of the three impeller blade types. The analysis consisted of mapping the pressures onto a three-dimensional finite element model, then converting these pressure loads to complex nodal force vectors at specified equal time intervals. The resulting vectors were then converted to modal force time histories that were then transformed into the frequency domain where the frequency response was calculated directly. This technique resulted in an improvement to the previously used direct integration technique and in a substantial analysis cost reduction.

Wellstein, Carl↗

High Pressure X-Ray Diffraction Studies of Nanocrystalline Materials

Experimental evidence obtained for a variety of nanocrystalline materials suggest that the crystallographic structure of a very small size particle deviates from that in the bulk crystals. In this paper we show the effect of the surface of nanocrystals on their structure by the analysis of generation and distribution of macro- and micro-strains at high pressures and their dependence on the grain size in nanocrystalline powders of Sic. We studied the structure of Sic nanocrystals by in-situ high-pressure powder diffraction technique using synchrotron and neutron sources and hydrostatic or isostatic pressure conditions. The diffraction measurements were done in HASYLAB at DESY using a Diamond Anvil Cell (DAC) in the energy dispersive geometry in the diffraction vector range up to 3.5 - 4/A and under pressures up to 50 GPa at room temperature. In-situ high pressure neutron diffraction measurements were done at LANSCE in Los Alamos National Laboratory using the HIPD and HIPPO diffractometers with the Paris-Edinburgh and TAP-98 cells, respectively, in the diffraction vector range up to 26 Examination of the response of the material to external stresses requires nonstandard methodology of the materials characterization and description. Although every diffraction pattern contains a complete information on macro- and micro-strains, a high pressure experiment can reveal only those factors which contribute to the characteristic diffraction patterns of the crystalline phases present in the sample. The elastic properties of powders with the grain size from several nm to micrometers were examined using three methodologies: (l), the analysis of positions and widths of individual Bragg reflections (used for calculating macro- and micro-strains generated during densification) [I], (2). the analysis of the dependence of the experimental apparent lattice parameter, alp, on the diffraction vector Q [2], and (3), the atomic Pair Distribution Function (PDF) technique [3]. The results of our studies show, that Sic nanocrystals have the features of two phases, each with its distinct elastic properties. and under pressures up to 8 GPa.

Palosz, B.↗

Degradation Characterization of Unsteady Pressure-Sensitive Paint Under Various Pressures

The lifetime and intensity techniques are two distinct methods used to measure the surface pressure of wind tunnel models with pressure-sensitive paint (PSP). When exposed to 405 nm light for extended periods, both the luminescence and the lifetime ratio were observed to decrease, affecting perceived pressure values. To help further the implementation of the uPSP, this paper describes the efforts to characterize the degradation of both the intensity of the paint and its lifetime ratio, as well as the change in intensity calibration. It was found that the paint degrades at different rates depending on the partial pressure of oxygen during excitation. It was also found that the calibration curves exhibit greater changes when under higher oxygen concentrations, both indicating photodegradation due to photodecomposition and photo-oxidation processes. These effects are observed on models in a subsonic 14” × 14” wind tunnel. The work provides insight into the dynamic degradation behavior of PSP and uPSP, paving the way to reduce the error in pressure measurements obtained through these techniques.

Pressure-Sensitive Paint↗

Characterization of Photodegredation in Unsteady Pressure-Sensitive Paint Under Varying Pressures

The lifetime and intensity techniques are two distinct methods used to measure the surface pressure of wind tunnel models with pressure-sensitive paint (PSP). When exposed to 405 nm light for extended periods, both the luminescence and the lifetime ratio were observed to decrease, affecting perceived pressure values. To help further the implementation of the unsteady pressure-sensitive paint (uPSP), this paper describes the efforts to characterize how photo degradation affects the intensity of the paint signal and its lifetime ratio, as well as the intensity calibration's response and how these changes vary with different pressure environments. It was found that the paint photo degrades at different rates depending on the partial pressure of oxygen during excitation. It was also found that the calibration curves exhibit greater changes when exposed to excitation light in higher pressure environments, both indicating photo degradation due to photo decomposition and photo-oxidation processes. These effects are observed on models in a subsonic 14” × 14” wind tunnel as well as a large-scale 11’ x 11’ transonic wind tunnel. The work provides analysis into the photo degradation behavior of PSP and uPSP, paving the way to reduce the error in pressure measurements obtained through these techniques.

Pressure-Sensitive Paint↗

Interfering surfaces in subsonic, transonic, and supersonic flow

Computer program provides analysis method based on kernel-function technique that uses assumed pressure functions with unknown coefficients. With technique, generalized forces are calculated in unsteady flow, and pressure distributions are obtained in steady and unsteady flow.

Cunningham, A. M., Jr.↗

Pressure sensing of the atmosphere by solar occultation using broadband CO2 absorption

A technique for obtaining pressure at the tangent point in an IR solar occulation experiment is described. By measuring IR absorption in bands of atmospheric CO2 (e.g., 2.0, 2.7, or 4.3 microns), mean pressure values for each tangent point layer (vertical thickness 2 km or less) of the atmosphere can be obtained with rms errors of less than 3%. The simultaneous retrieval of pressure and gas concentration in a remote-sensing experiment will increase the accuracy of inverted gas concentrations and minimize the dependence of the experiment on pressure or mass path error resulting from use of climatological pressure data, satellite ephemeris, and instrument pointing accuracy.

Park, J. H.↗

Flight testing of a luminescent surface pressure sensor

NASA ARC has conducted flight tests of a new type of aerodynamic pressure sensor based on a luminescent surface coating. Flights were conducted at the NASA ARC-Dryden Flight Research Facility. The luminescent pressure sensor is based on a surface coating which, when illuminated with ultraviolet light, emits visible light with an intensity dependent on the local air pressure on the surface. This technique makes it possible to obtain pressure data over the entire surface of an aircraft, as opposed to conventional instrumentation, which can only make measurements at pre-selected points. The objective of the flight tests was to evaluate the effectiveness and practicality of a luminescent pressure sensor in the actual flight environment. A luminescent pressure sensor was installed on a fin, the Flight Test Fixture (FTF), that is attached to the underside of an F-104 aircraft. The response of one particular surface coating was evaluated at low supersonic Mach numbers (M = 1.0-1.6) in order to provide an initial estimate of the sensor's capabilities. This memo describes the test approach, the techniques used, and the pressure sensor's behavior under flight conditions. A direct comparison between data provided by the luminescent pressure sensor and that produced by conventional pressure instrumentation shows that the luminescent sensor can provide quantitative data under flight conditions. However, the test results also show that the sensor has a number of limitations which must be addressed if this technique is to prove useful in the flight environment.

Mclachlan, B. G.↗

Vapor pressures of acetylene at low temperatures

The atmospheres of many of the outer planets and their satellites contain a large number of hydrocarbon species. In particular, acetylene (C2H2) has been identified at Jupiter, Saturn and its satellite Titan, Uranus and Neptune. In the lower atmospheres of these planets, where colder temperatures prevail, the condensation and/or freezing of acetylene is probable. In order to obtain accurate models of the acetylene in these atmospheres, it is necessary to have a complete understanding of its vapor pressures at low temperatures. Vapor pressures at low temperatures for acetylene are being determined. The vapor pressures are measured with two different techniques in order to cover a wide range of temperatures and pressures. In the first, the acetylene is placed in a sample tube which is immersed in a low temperature solvent/liquid nitrogen slush bath whose temperature is measured with a thermocouple. The vapor pressure is then measured directly with a capacitance manometer. For lower pressures, a second technique which was called the thin-film infrared method (TFIR) was developed. It involves measuring the disappearance rate of a thin film of acetylene at a particular temperature. The spectra are then analyzed using previously determined extinction coefficient values, to determine the disappearance rate R (where R = delta n/delta t, the number of molecules that disappear per unit time). This can be related to the vapor pressure directly. This technique facilitates measurement of the lower temperatures and pressures. Both techniques have been calibrated using CO2, and have shown good agreement with the existing literature data.

Masterson, C. M.↗

Wrapped Wire Detects Rupture Of Pressure Vessel

Simple, inexpensive technique helps protect against damage caused by continuing operation of equipment after rupture or burnout of pressure vessel. Wire wrapped over area on outside of vessel where breakthrough most likely. If wall breaks or burns, so does wire. Current passing through wire ceases, triggering cutoff mechanism stopping flow in vessel to prevent further damage. Applied in other situations in which pipes or vessels fail due to overpressure, overheating, or corrosion.

Hunt, James B.↗