Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Fused Bead Analysis of Diogenite Meteorites

Bulk rock chemistry is an essential dataset in meteoritics and planetary science [1]. A common method used to obtain the bulk chemistry of meteorites is ICP-MS. While the accuracy, precision and low detection limits of this process are advantageous [2], the sample size used for analysis (approx.70 mg) can be a problem in a field where small and finite samples are the norm. Fused bead analysis is another bulk rock analytical technique that has been used in meteoritics [3]. This technique involves forming a glass bead from ~10 mg of sample and measuring its chemistry using a defocused beam on a microprobe. Though the ICP-MS has lower detection limits than the microprobe, the fused bead method destroys a much smaller sample of the meteorite. Fused bead analysis was initially designed for samples with near-eutectic compositions and low viscosities. Melts generated of this type homogenize at relatively low temperatures and produce primary melts near the sample s bulk composition [3]. The application of fused bead analysis to samples with noneutectic melt compositions has not been validated. The purpose of this study is to test if fused bead analysis can accurately determine the bulk rock chemistry of non-eutectic melt composition meteorites. To determine this, we conduct two examinations of the fused bead. First, we compare ICP-MS and fused bead results of the same samples using statistical analysis. Secondly, we inspect the beads for the presence of crystals and chemical heterogeneity. The presence of either of these would indicate incomplete melting and quenching of the bead.

Mittlefehldt, D.W.↗

Automated Lab-on-a-Chip Electrophoresis System

Capillary electrophoresis is an analytical technique that can be used to detect and quantify extremely small amounts of various biological molecules. In the search for biochemical traces of life on other planets, part of this search involves an examination of amino acids, which are the building blocks of life on Earth. The most sensitive method for detecting amino acids is the use of laser induced fluorescence. However, since amino acids do not, in general, fluoresce, they first must be reacted with a fluorescent dye label prior to analysis. After this process is completed, the liquid sample then must be transported into the electrophoresis system. If the system is to be reused multiple times, samples must be added and removed each time. In typical laboratories, this process is performed manually by skilled human operators using standard laboratory equipment. This level of human intervention is not possible if this technology is to be implemented on extraterrestrial targets. Microchip capillary electrophoresis (CE) combined with laser induced fluorescence detection (LIF) was selected as an extremely sensitive method to detect amino acids and other compounds that can be tagged with a fluorescent dye. It is highly desirable to package this technology into an integrated, autonomous, in situ instrument capable of performing CE-LIF on the surface of an extraterrestrial body. However, to be fully autonomous, the CE device must be able to perform a large number of sample preparation and analysis operations without the direct intervention of a human.

Willis, Peter A.↗

Sampling and Analysis Plan for Investigation of Undeclared Nuclear Activities - 20104

The nuclear-centered energy policy in South Korea is moving towards a nuclear-free era. It also facilitates an action or progress on the denuclearization of the Korean peninsula. The Nuclear Safety and Security Commission (NSSC) launched a new R and D project which attempts to verify nuclear activities via analyzing environmental samples. Environmental samples possibly contain significant radiological information relevant to past undeclared activities. In order to precisely verify them, it is essential to provide 1) the concrete information of target facilities, 2) appropriate methodologies and procedures, and 3) well-suited instrumentation and equipment corresponding to sample signatures. It is also important to provide scientific reliability or validity in any process such as sample collection, handling, transportation and laboratory analysis. Therefore, the information of nuclear facilities (fuel fabrication plant, graphite moderated reactor, reprocessing plant) in North Korea are reviewed in order to determine parameters for appropriate sampling methods representing a facility's characteristics. Secondly, a sampling procedure for radioactive elements is being developed based on international and domestic standards such as ASTM (American Society for Testing and Materials), KS (Korean industrial Standards), and International Atomic Energy Agency (IAEA) manuals. The procedure contains some specific information including sampling process, sampling tools, amount of sample, sample identification, and other related information. Developing the qualified national guidelines is most important since sampling and analyzing results can be used as evidences of nuclear activities. The guideline developed through this work will clearly define various methodologies such as document verification, sampling procedures, collection methods, sample storage criteria, chain of custody, and transportation conditions. The final objective of this work is to establish the infrastructure and regulatory framework for assessment of nuclear activities, and provide a national guideline for sampling and analysis. This will bring confidence in the results and play a critical role in complete denuclearization progress in South Korea. (authors)

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Space Weathering in OSIRIS-REx Samples From Bennu: Impact Melt Deposits

Early analyses of regolith samples from asteroid Bennu delivered by the OSIRIS-REx spacecraft showed a mineralogy dominated by hydrated silicates, sulfides, magnetite, phosphates, and abundant organic matter, in addition to other minor/trace phases. A major objective of the sample analysis campaign is to understand the nature and extent of space weathering processes recorded by returned samples from Bennu. Here we report our preliminary transmission electron microscope (TEM) observations of impact melt deposits on surfaces of Bennu sample particles.

L. P. Keller↗

Characterising Ion-Irradiated FeCr: Hardness, Thermal Diffusivity and Lattice Strain

Ion-irradiated FeCr alloys are useful for understanding and predicting neutron damage in the structural steels of future nuclear reactors. Previous studies have largely focused on the structure of irradiation induced defects, probed by transmission electron microscopy (TEM), as well as changes in mechanical properties. Across these studies, a wide range of irradiation conditions has been employed on samples with different processing histories, which complicates the analysis of the relationship between defect structures and material properties. Furthermore, key properties, such as irradiation-induced changes in thermal transport and lattice strain, are little explored. Here we present a systematic study of Fe3Cr, Fe5Cr and Fe10Cr binary alloys implanted with 20 MeV Fe3+ ions to nominal doses of 0.01 dpa and 0.1 dpa at room temperature. Nanoindentation, transient grating spectroscopy (TGS) and X-ray micro-beam Laue diffraction were used to study the changes in hardness, thermal diffusivity and strain in the material as a function of damage and Cr content. Our results suggest that Cr leads to an increased retention of irradiation-induced defects, causing substantial changes in hardness and lattice strain. However, thermal diffusivity varies little with increasing damage and instead degrades significantly with increasing Cr content in the material. We find significant lattice strains even in samples exposed to a nominal displacement damage of 0.01 dpa. The defect density predicted from the lattice strain measurements is significantly higher than that observed in previous TEM studies, suggesting that TEM may not fully capture the irradiation-induced defect population. (C) 2020 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

FeCr alloys↗

Comparative quantification and statistical analysis of η′ and η precipitates in aluminum alloy AA7075-T651 by TEM and AFM

Quantification of nanometric precipitates in metallic alloys has been traditionally performed using transmission electron microscopy, which is nominally a low throughput technique. This work presents a comparative study of quantification of η′ and η precipitates in aluminum alloy AA7075-T651 using transmission electron microscopy (TEM) and non-contact atomic force microscopy (AFM). AFM quantification was compared with 2-D stereological results reported elsewhere. Also, a method was developed, using specialized software, to characterize nanometric size precipitates observed in dark-field TEM micrographs. Statistical analysis of the quantification results from both measurement techniques supports the use of AFM for precipitate characterization. Once the precipitate stoichiometry has been determined by appropriate analytical techniques like TEM, as it is the case for η′ and η in AA7075-T651, the relative ease with which specimens are prepared for AFM analysis could be advantageous in product and process development, and quality control, where a large number of samples are expected for analysis on a regular basis. - Highlights: • Nanometric MgZn{sub 2} precipitates in AA7075-T651 were characterized using AFM and TEM. • Phase-contrast AFM was used to differentiate metal matrix from MgZn{sub 2} precipitates. • TEM and AFM micrographs were analyzed using commercially available software. • AFM image analysis and TEM 2-D stereology render statistically equivalent results.

36 MATERIALS SCIENCE↗

Analysis of Krypton-85 Legacy Waste Forms: Part II

During a removal of legacy materials from one hot cell at the Idaho National Laboratory in 2010, five metal capsules and some loose zeolite material were identified as krypton (Kr) immobilization test specimens produced in the late 1970s under the Airborne Waste Management Program (AWMP). This AWMP research and development effort examined the encapsulation of 85Kr within a collapsed zeolite structure for use as a potential waste form for long-term storage. The recovered capsules appeared to have been placed to the side and remained untouched after the AWMP was halted in the mid-1980s. These reclaimed capsules and loose material presented a unique opportunity to study a potential 85 Kr waste form after three half-lives had elapsed. The first phase of this study included two parts: The first was to assess the physical condition of the capsule walls, and the second was to examine the Kr-containing material within the capsules. The first part of this study was previously reported and noted that substantial corrosion was observed throughout each capsule wall of the two previously breached capsules that were examined. One of these capsules had been hot isostatic pressed (HIPed) and one was not HIPed. The second part of the study examined the materials contained in the two previously breached capsules. There appears to be a relatively uniform distribution of Kr and rubidium throughout the pellets examined. The chemical composition of the pellets appears to be consistent with 5A molecular sieves. The material contained within the HIPed capsules showed ~1 at. % lead (Pb). The origin of the Pb is currently indeterminate. X-ray diffraction analysis shows a significant shift from the 5A structure, most likely due to the Kr encapsulation/sintering process that occurred when the samples were made. Calculations based on the energy dispersive spectrometry elemental analysis show a residual Kr level within the pellets that is within a factor of 2 of the reported Kr capacities for this type of processed material. This provides a clear indication that a significant fraction of the Kr initially encapsulated in the material remained within the waste form even following a significant breach of the capsule wall. As a result, it would appear that this Kr immobilization method, even in non-HIPed form, is very promising as a waste form for long-term storage. The successful analysis of these two breached capsules forms a solid basis for the future analysis of the remaining unbreached capsules, which offers the opportunity to provide an even more complete understanding of the long-term Kr retention performance of this promising waste form.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

X-Ray Fluorescence Quantitative and Qualitative Analysis Using Micro Glass Beads

The fused glass bead method is the accepted 'best practice' method of preparation of samples for X-ray fluorescence (XRF) analysis. It minimizes the effects of sample heterogeneity and simplifies calibration by dissolving the sample into a uniform glass matrix. Glass fusion XRF samples are typically prepared by grinding sample powder with Lithium Tetraborate / Lithium Bromide and fusing the mixture at 1000 deg. C. In most cases sample-to-flux ratios of between 1:1 to 1:10 are used (1:1 for determination of trace elements and 1:10 for major elements). Typical sample mass consumed is in the range of 1000 to 2500 mg. It would be advantageous to reduce this sample mass in cases where the sample material is rare, valuable or highly radioactive. This study examines the effects of using lower sample-to-flux ratios and smaller fusion bead size on the detection and quantification of major and trace elements by XRF analysis. We have employed a micro fused glass bead process, using sample-to-flux ratios of 1:10, 1:15 and 1:25, to determine the effects on measurement precision, accuracy and detection limit. Objectives: - Created micro fused glass beads of a series of standards and andesite sample with sample-to-flux ratios of 1:10, 1:15 and 1:25. - Perform an qualitative analysis of the different sample-to-flux ratio micro beads and compare the results with the 1:5.3 beads routinely used at SRNL. - Quantitate the major components in the different sample-to-flux ratio micro beads using a wavelength dispersive x-ray fluorescence instrument. Advantages: - Reduce sample amount needed. - Speed up waste tank characterization. - Reduce personnel exposure. - Potential sealed source. Fused micro glass beads with sample-to-flux ratios of 1:10, 1:15 and 1:25 were created using sample amounts of 123 mg, 82 mg and 52 mg respectively. It was possible to detect most of the major oxides and some trace elements in the fused micro glass beads with different sample-to-flux ratios. The quantitative analysis showed good linear correlation between the intensity of the analysis and the concentration of the elements. Good precision and accuracy results were obtained for the majority of the major oxides in the three fused micro glass beads with different sample-to-flux ratios. Path Forward: Enhance the precision and accuracy of the method by optimizing different sample preparation steps, such as weighing and sample transfer. Continue to increase the sample-to-flux ratio to determine the minimum amount of sample needed to perform a multielement analysis. Consider the use of synthetic standards to lower the detection limit of the analysis. Used the micro bead sample preparation method to analyze radioactive samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fast processing of data from Sneg-2MP experiment

The following subjects are covered: Basic stages during computer processing of data from Sneg-2MP instrument, basic modes during separation and fast processing (separation of data during satellite flight, separation of burst data segments, sampling and analysis of initial burst data segment). Experimental results obtained on the basis of fast processed data are reported.

Dumer, I. I.↗

Versatile technique for assessing thickness of 2D layered materials by XPS

X-ray photoelectron spectroscopy (XPS) has been utilized as a versatile method for thickness characterization of various two-dimensional (2D) films. Accurate thickness can be measured simultaneously while acquiring XPS data for chemical characterization of 2D films having thickness up to approximately 10 nm. For validating the developed technique, thicknesses of few-layer graphene (FLG), MoS 2 and amorphous boron nitride (a-BN) layer, produced by microwave plasma chemical vapor deposition (MPCVD), plasma enhanced chemical vapor deposition (PECVD), and pulsed laser deposition (PLD) respectively, were accurately measured. The intensity ratio between photoemission peaks recorded for the films (C 1s, Mo 3d, B 1s) and the substrates (Cu 2p, Al 2p, Si 2p) is the primary input parameter for thickness calculation, in addition to the atomic densities of the substrate and the film, and the corresponding electron attenuation length (EAL). The XPS data was used with a proposed model for thickness calculations, which was verified by cross-sectional transmission electron microscope (TEM) measurement of thickness for all the films. The XPS method determines thickness values averaged over an analysis area which is orders of magnitude larger than the typical area in cross-sectional TEM imaging, hence provides an advanced approach for thickness measurement over large areas of 2D materials. The study confirms that the versatile XPS method allows rapid and reliable assessment of the 2D material thickness and this method can facilitate in tailoring growth conditions for producing very thin 2D materials effectively over a large area. Furthermore, the XPS measurement for a typical 2D material is non-destructive and does not require special sample preparation. Furthermore, after XPS analysis, exactly the same sample can undergo further processing or utilization.

2D film thickness↗

SHαDE: survey description and mass–kinematics scaling relations for dwarf galaxies

ABSTRACT The Study of H α from Dwarf Emissions (SHαDE) is a high spectral resolution (R = 13 500) H α integral field survey of 69 dwarf galaxies with stellar masses 106 < M⋆ < 109 M⊙. The survey used FLAMES on the ESO Very Large Telescope. SHαDE is designed to study the kinematics and stellar populations of dwarf galaxies using consistent methods applied to massive galaxies and at matching level of detail, connecting these mass ranges in an unbiased way. In this paper, we set out the science goals of SHαDE, describe the sample properties, outline the data reduction, and analysis processes. We investigate the log M⋆–log S0.5 mass–kinematics scaling relation, which has previously shown potential for combining galaxies of all morphologies in a single scaling relation. We extend the scaling relation from massive galaxies to dwarf galaxies, demonstrating this relation is linear down to a stellar mass of M⋆ ∼ 108.6 M⊙. Below this limit, the kinematics of galaxies inside one effective radius appears to be dominated by the internal velocity dispersion limit of the H α-emitting gas, giving a bend in the log M⋆–log S0.5 relation. Replacing stellar mass with total baryonic mass using gas mass estimate reduces the severity but does not remove the linearity limit of the scaling relation. An extrapolation to estimate the galaxies’ dark matter halo masses, yields a log Mh–log S0.5 scaling relation that is free of any bend, has reduced curvature over the whole mass range, and brings galaxies of all masses and morphologies on to the virial relation.

Barat, Dilyar↗

A multimodal and integrated approach to interrogate human kidney biopsies with rigor and reproducibility: guidelines from the Kidney Precision Medicine Project

Comprehensive and spatially mapped molecular atlases of organs at a cellular level are a critical resource to gain insights into pathogenic mechanisms and personalized therapies for diseases. The Kidney Precision Medicine Project (KPMP) is an endeavor to generate three-dimensional (3-D) molecular atlases of healthy and diseased kidney biopsies by using multiple state-of-the-art omics and imaging technologies across several institutions. Obtaining rigorous and reproducible results from disparate methods and at different sites to interrogate biomolecules at a single-cell level or in 3-D space is a significant challenge that can be a futile exercise if not well controlled. Here we describe a “follow the tissue” pipeline for generating a reliable and authentic single-cell/region 3-D molecular atlas of human adult kidney. Our approach emphasizes quality assurance, quality control, validation, and harmonization across different omics and imaging technologies from sample procurement, processing, storage, shipping to data generation, analysis, and sharing. We established benchmarks for quality control, rigor, reproducibility, and feasibility across multiple technologies through a pilot experiment using common source tissue that was processed and analyzed at different institutions and different technologies. A peer review system was established to critically review quality control measures and the reproducibility of data generated by each technology before their being approved to interrogate clinical biopsy specimens. The process established economizes the use of valuable biopsy tissue for multiomics and imaging analysis with stringent quality control to ensure rigor and reproducibility of results and serves as a model for precision medicine projects across laboratories, institutions and consortia.

59 BASIC BIOLOGICAL SCIENCES↗

RCT: Module 2.03, Counting Errors and Statistics, Course 8768

Radiological sample analysis involves the observation of a random process that may or may not occur and an estimation of the amount of radioactive material present based on that observation. Across the country, radiological control personnel are using the activity measurements to make decisions that may affect the health and safety of workers at those facilities and their surrounding environments. This course will present an overview of measurement processes, a statistical evaluation of both measurements and equipment performance, and some actions to take to minimize the sources of error in count room operations. This course will prepare the student with the skills necessary for radiological control technician (RCT) qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and by providing in the field skills.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Innovative Strategies for Long-Term Monitoring of Complex Groundwater Plumes at DOE’s Legacy Sites (Workshop Report)

Most remaining Department of Energy (DOE) sites will require extended periods of institutional control, especially at complex groundwater sites where attenuation-based strategies have been implemented to facilitate closure. The current practice of monitoring—obtaining and analyzing contaminant concentration in groundwater samples at numerous wells—will account for a large portion of the projected life-cycle at these DOE sites unless a new approach is adopted. State-of-the-art technologies are being developed, including in situ sensors, geophysics, radiation mapping, numerical modeling and AI/ML. These technologies can optimize monitoring strategies in space and time, provide spatially extensive information at vulnerable regions and/or provide more continuous monitoring at lower cost. As part of DOE’s Office of Environmental Management (DOE-EM’s) efforts to advance long-term monitoring systems, an in-person/virtual hybrid workshop was hosted by Savannah River National Laboratory (SRNL) on January 24 and 25, 2023, in Augusta, Georgia. Because DOE-EM’s complex sites will eventually be transferred to DOE’s Office of Legacy Management (DOE-LM), representatives of DOE-LM were important participants in the workshop. The purpose of the workshop was to identify challenges and opportunities for deploying advanced technologies for long-term monitoring at DOE sites. The key questions during the workshop were: 1) the regulatory acceptance of replacing a process that traditionally has used laboratory sampling and analysis of groundwater samples, and 2) the application of this strategy to the southwestern arid sites that include many of the remaining DOE-EM and DOE-LM complex groundwater plumes. Characteristics common to most arid sites present both limitations and opportunities for advanced technologies. DOE-EM has funded a National Laboratory team from SRNL, Lawrence Berkeley National Laboratory (LBNL), and Pacific Northwest National Laboratory (PNNL) to establish the overarching framework of long-term monitoring by systematically combining advanced hardware and software technologies. This project is titled “Advanced Long-Term Environmental Monitoring Systems (ALTEMIS)” and is sponsored by the DOE-EM Technology Development Program. The multi-laboratory team is currently developing and testing innovative monitoring strategies, including the use of in situ groundwater sensors, geophysics, drone/satellite-based remote sensing, reactive transport modeling, and artificial intelligence/machine learning (AI/ML). The project’s demonstration testbed is at the Savannah River Site (SRS) F-Area Seepage Basins, where a well-characterized complex groundwater plume composed of uranium and other radionuclides is in the latter stages of remediation. The workshop included more than 70 participants, presentations, a field visit to F-Area, breakout working groups, and large group discussion. Participants developed recommendations on five topics: in situ sensors, spatially integrative tools, challenges to regulatory acceptance, AI/ML strategies, and transitioning sites to DOE-LM.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remote sensing of coal mine pollution in the upper Potomac River basin

A survey of remote sensing data pertinent to locating and monitoring sources of pollution resulting from surface and shaft mining operations was conducted in order to determine the various methods by which ERTS and aircraft remote sensing data can be used as a replacement for, or a supplement to traditional methods of monitoring coal mine pollution of the upper Potomac Basin. The gathering and analysis of representative samples of the raw and processed data obtained during the survey are described, along with plans to demonstrate and optimize the data collection processes.

Source record↗

Remote water-monitoring system

General-purpose, water-quality sampling process detects microorganisms and integrates sampling, sample preservation, and sample analysis. System overcomes difficulties in correlation of surface measurements with remote measurements and minimizes human error in handling of samples and instrumentation.

Grana, D. C.↗

A Web-Based System for Monitoring and Controlling Multidisciplinary Design Projects

In today's competitive environment, both industry and government agencies are under enormous pressure to reduce the time and cost of multidisciplinary design projects. A number of frameworks have been introduced to assist in this process by facilitating the integration of and communication among diverse disciplinary codes. An examination of current frameworks reveals weaknesses in various areas such as sequencing, displaying, monitoring, and controlling the design process. The objective of this research is to explore how Web technology, in conjunction with an existing framework, can improve these areas of weakness. This paper describes a system that executes a sequence of programs, monitors and controls the design process through a Web-based interface, and visualizes intermediate and final results through the use of Java(Tm) applets. A small sample problem, which includes nine processes with two analysis programs that are coupled to an optimizer, is used to demonstrate the feasibility of this approach.

Salas, Andrea O.↗

Tracking capability for entry, descent and landing and its support to NASA Mars Exploration Rovers

This paper described a new capability recently deployed in the NASA Deep Space Network to support the entry, descent and landing of the two Mars Exploration Rovers - Spirit and Opportunity. This final segment of a 7-month journey was critical step in enabling successful mission operation. The EDL Data Analysis (EDA) equipment processed the open loop recording samples from the existing radio science receivers, extracted the MFSK-modulated tones, and provided information on the occurrence of associated events happened onboard spacecraft. The EDA software supported real-time as well as post pass processing. The design flexibility allowed the track to be divided into different segments, each could be processed with a configuration optimized for its signal conditions and uncertainties. The use of dynamic lock state concept enabled signal detection be done with minimum required computing power - less was spent when signal was steadily detected and more when signal fluctuated. With the server-client design, the EDA supported connections to different remote operation centers for monitor purpose. The paper also presented the field results from both Spirit and Opportunity landings. The detection were much better than anticipated. All critical event tones were seen in real time. Surprising detection of LCP signal was found with Spirit landing, resulted in a reconfiguration for Opportunity landing to maximize signal detection.

tracking↗