Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The pick-up of cometary protons by the solar wind

The High Energy Range Spectrometer (HERS) of the Ion Mass Spectrometer on the Giotto spacecraft measured the 3-dimensional distribution of picked-up cometary protons over a distance of approximately 8 million km upstream of the bow shock of Comet Halley. The protons were observed to be elastically scattered out of their original cycloidal trajectories such that they were nonuniformly distributed over a spherical shell in velocity space. The shell radius (relative to its expected radius) and thickness increased as the bow shock was approached. Downstream of the shock, the cometary protons could not be distinguished from the heated solar wind protons.

Neugebauer, M.↗

Response of thyroid follicular cells to gamma irradiation compared to proton irradiation: II. The role of connexin 32

The objective of this study was to determine whether connexin 32-type gap junctions contribute to the "contact effect" in follicular thyrocytes and whether the response is influenced by radiation quality. Our previous studies demonstrated that early-passage follicular cultures of Fischer rat thyroid cells express functional connexin 32 gap junctions, with later-passage cultures expressing a truncated nonfunctional form of the protein. This model allowed us to assess the role of connexin 32 in radiation responsiveness without relying solely on chemical manipulation of gap junctions. The survival curves generated after gamma irradiation revealed that early-passage follicular cultures had significantly lower values of alpha (0.04 Gy(-1)) than later-passage cultures (0.11 Gy(-1)) (P < 0.0001, n = 12). As an additional way to determine whether connexin 32 was contributing to the difference in survival, cultures were treated with heptanol, resulting in higher alpha values, with early-passage cultures (0.10 Gy(-1)) nearly equivalent to untreated late-passage cultures (0.11 Gy(-1)) (P > 0.1, n = 9). This strongly suggests that the presence of functional connexin 32-type gap junctions was contributing to radiation resistance in gamma-irradiated thyroid follicles. Survival curves from proton-irradiated cultures had alpha values that were not significantly different whether cells expressed functional connexin 32 (0.10 Gy(-1)), did not express connexin 32 (0.09 Gy(-1)), or were down-regulated (early-passage plus heptanol, 0.09 Gy(-1); late-passage plus heptanol, 0.12 Gy(-1)) (P > 0.1, n = 19). Thus, for proton irradiation, the presence of connexin 32-type gap junctional channels did not influence their radiosensitivity. Collectively, the data support the following conclusions. (1) The lower alpha values from the gamma-ray survival curves of the early-passage cultures suggest greater repair efficiency and/or enhanced resistance to radiation-induced damage, coincident with the expression of connexin 32-type gap junctions. (2) The increased sensitivity of FRTL-5 cells to proton irradiation was independent of their ability to communicate through connexin 32 gap junctions. (3) The fact that the beta components of the survival curves from both gamma rays and proton beams were similar (average 0.022 +/- 0.008 Gy(-2), P > 0.1, n = 39) suggests that at higher doses the loss of viability occurs at a relatively constant rate and is independent of radiation quality and the presence of functional gap junctions.

Non-NASA Center↗

Mechanisms of mutagenesis in human cells exposed to 55 MeV protons

Protons represent the major type of charged particle radiation in spaceflight environments. The purpose of this study was to assess mutations arising in human lymphoid cells exposed to protons. Mutations were quantitated at the thymidine kinase (TK1) locus in cell lines derived from the same donor: TK6 cells (wt TP53) and WTK1 cells (mutant TP53). WTK1 cells were much more susceptible to mutagenesis following proton exposure than TK6 cells. Intragenic deletions were observed among early-arising TK1 mutants in TK6 cells, but not in WTK1 cells where all of the mutants arose by LOH. Deletion was the predominant mode of LOH in TK6 cells, while allelic recombination was the major mode of LOH in WTK1 cells. Deletions were of variable lengths, from <1 cM to 64 cM, while mutations that arose by allelic recombination often extended to the telomere. In summary, proton exposures elicited many types of mutations at an autosomal locus in human cells. Most involved large scale loss of genetic information, either through deletion or by recombination.

NASA Discipline Radiation Health↗

Particle directionality and trapped proton fluences on LDEF

Directionality of incident space radiation is a significant factor in spacecraft shielding and astronaut dosimetry in low Earth orbit (LEO). Particle directionality of GCR and trapped protons were measured on LDEF with plastic nuclear track detectors (PNTD) from the P0006 west-side experiment. This experiment consisted of a thick detector stack and is described more fully in a companion article (Benton et al., 1996). The anisotropy of the trapped protons produced maximum intensity for protons arriving from the west. The fluences of the eastward directed trapped protons have been measured by selection of the particles on the basis of range in the PNTDs. The measured fluences are compared with the model calculations of Armstrong and Colborn (1993).

unmanned↗

Measuring the spectrum of mutation induced by nitrogen ions and protons in the human-hamster hybrid cell line A(L)C

Astronauts can be exposed to charged particles, including protons, alpha particles and heavier ions, during space flights. Therefore, studying the biological effectiveness of these sparsely and densely ionizing radiations is important to understanding the potential health effects for astronauts. We evaluated the mutagenic effectiveness of sparsely ionizing 55 MeV protons and densely ionizing 32 MeV/nucleon nitrogen ions using cells of two human-hamster cell lines, A(L) and A(L)C. We have previously characterized a spectrum of mutations, including megabase deletions, in human chromosome 11, the sole human chromosome in the human-hamster hybrid cell lines A(L)C and A(L). CD59(-) mutants have lost expression of a human cell surface antigen encoded by the CD59 gene located at 11p13. Deletion of genes located on the tip of the short arm of 11 (11p15.5) is lethal to the A(L) hybrid, so that CD59 mutants that lose the entire chromosome 11 die and escape detection. In contrast, deletion of the 11p15.5 region is not lethal in the hybrid A(L)C, allowing for the detection of chromosome loss or other chromosomal mutations involving 11p15.5. The 55 MeV protons and 32 MeV/nucleon nitrogen ions were each about 10 times more mutagenic per unit dose at the CD59 locus in A(L)C cells than in A(L) cells. In the case of nitrogen ions, the mutations observed in A(L)C cells were predominantly due to chromosome loss events or 11p deletions, often containing a breakpoint in the pericentromeric region. The increase in the CD59(-) mutant fraction for A(L)C cells exposed to protons was associated with either translocation of portions of 11q onto a hamster chromosome, or discontinuous or "skipping" mutations. We demonstrate here that A(L)C cells are a powerful tool that will aid in the understanding of the mutagenic effects of different types of ionizing radiation.

Non-NASA Center↗

Effects of proton and gamma radiation on lymphocyte populations and acute response to antigen

BACKGROUND: The clinical use of proton radiation in the management of cancer, as well as benign disorders, is rapidly increasing. The major goal of this study was to compare the effects of proton and gamma (60Co) radiation on cell-mediated and humoral immunological parameters. MATERIALS AND METHODS: C57BL/6 mice were exposed to a single dose of 3 Gray (Gy) protons or gamma-rays and intraperitoneally injected 1 day later with sheep red blood cells (sRBC). On 4, 10, 15, and 29 days after exposure, subsets from each group were euthanised; nonirradiated controls (with and without sRBC injection) were included. Body and relative spleen weights, leukocyte counts, spontaneous blastogenesis, lymphocyte populations, and anti-sRBC titers were evaluated. RESULTS: The data showed significant depression (p < 0.05) in nearly all assays on days 4 and 10 after irradiation. B lymphocytes (CD19+) were the most radiosensitive, although reconstitution back to normal levels was observed by day 15. T cell (CD3+) and T helper cell (CD4+) recovery was evident by day 29, whereas the T cytotoxic cell (CD8+) count remained significantly below normal. Natural killer cells (NK1.1+) were relatively radioresistant. Anti-sRBC antibody production was slow and low titers were obtained after irradiation. No significant differences were noted between the two types of radiation. CONCLUSIONS: Taken together, the data show that whole-body irradiation with protons or gamma-rays, at the dose employed, results in marked, but transient, immunosuppression. However, at the time points of testing and with the assays used, little or no differences were found between the two forms of radiation.

NASA Discipline Radiation Health↗

Electron and proton flux models for Jupiter's radiation belts

Estimates of the energetic particle distribution in Jupiter's radiation belts are presented and are compared with previous estimates. Mathematical expressions are developed for the equatorial electron and proton fluxes, shielded electron and proton dose rates, and radiation lifetimes of electronic circuits. It is calculated that a 1 g/sq cm aluminum shield will screen out all protons of energy less than 27.5 MeV, and a 2 g/sq cm shield will screen out protons less than 40.6 MeV. The radiation lifetimes are based on a maximum permissible dose value of 10 million rads, a value 1/2 to 1/3 of the flux at which electronic circuits begin to fail. Estimated increases in lifetimes by using a 3 x 50 orbit instead of a 3 x 3 orbit, and going from 1 to 2 g/sq cm are given.

Klopp, D. A.↗

Discussion of the reliability of electron densities and energies interpreted from data and limits on the proton energy and density

Analysis of radio observations of Jupiter were changed to take into account the antenna resolution. A dipole magnetic field with a surface equatorial value of 7 gauss is assumed. The electron temperature is found to increase for r 2.5 Jupiter radii with decreasing r as 1/r cubed, reaching a peak of about 100 MeV at r = 2.5 Jupiter radii. For r 2.5 Jupiter radii, the electron temperature goes as r to the 6th power because of energy lost to radiation. The consequences of making an upper estimate on the proton flux by assuming the magnetic field is loaded with all the energetic protons it can hold are described. The upper limits of proton energy, density, flux, and energy flux are calculated for 1, 2, 2.5, 3, and 6 Jupiter radii. The proton energy and velocity estimates are considered to be fairly reliable; the upper limit to the number density is probably much higher than actuality.

Beard, D. B.↗

The effect of Jupiter's satellites on the diffusion of protons

Proton diffusion data are calculated for the Jovian satellites Amalthea, Io, Europa, Ganymede, and Callisto, assuming an equatorial magnetic field at Jupiter's surface of 10 gauss. The cyclotron radius, bounce period, and drift period are calculated for 1 MeV protons. These characteristics and the proton energy at the satellite, mean life near the satellite before impact, and diffusion time are also calculated for 100 MeV protons which conserve their first adiabatic invariant. The longitudinal distance between successive bounces is of the order of a few satellite radii.

Mead, G. D.↗

RBE for late somatic effects in mice irradiated with 60 MeV protons relative to X-rays.

Investigation of the relative biological effectiveness of energetic protons for the induction of somatic effects in a mammal (mice) following whole body irradiation. The proton energy used approximates the mean energy for proton spectra accompanying solar events. The effects on longevity and the incidence of major neoplastic diseases are summarized. The results obtained suggest that medium energy proton irradiation is no more effective, and on the whole, probably less effective, than conventional X radiation for the induction of late radiation effects in the mouse.

Darden, E. B., Jr.↗

Electron-proton spectrometer design summary

The electron-proton spectrometer (EPS) will be placed aboard the Skylab in order to provide data from which electron and proton radiation dose can be determined. The EPS has five sensors, each consisting of a shielded silicon detector. These provide four integral electron channels and five integral proton channels from which can be deduced four differential proton increments.

Source record↗

Time variations of magnetospheric intensities of outer zone protons, alpha particles and ions (Z greater than or equal to 2)

A comprehensive study of the temporal behavior of trapped protons, alpha particles and ions (Z 2) in outer zone of the earth's magnetosphere has been made. These observations were made by the Injun V satellite during the first 21 months of operation, August 1968 to May 1970. Rapid increases in the observed number of particles followed by slower exponential decay characterize the data. Comparisons are made with the temporal behavior of interplanetary particles of the same energy observed by Explorer 35. Increases in the trapped fluxes generally correspond to enhanced interplanetary activity. The energy spectra of protons and alpha particles at L = 3 have similar shapes when compared on an energy per charge basis while the respective polar cap spectra have similar shape on an energy per nucleon basis. Apparent inward trans-L motion of energetic protons is observed. These particles are diffused inward by a process involving fluctuating electric fields. The loss of trapped low altitude protons, alpha particles and ions (Z 2) is controlled by coulombic energy loss in the atmosphere.

Randall, B. A.↗

Probabilities for the peak flux and fluence of energetic solar protons incident on interplanetary spacecraft

Energetic protons injected into interplanetary space in solar particle events can interfere with spacecraft operations and experiments and can cause permanent degradation of some components. For future long term interplanetary and planetary missions, techniques were developed which use solar particle event data from 1956 through 1970 to predict the probability of exceeding any value of peak proton intensity or mission proton fluence. Dependences on proton energy (near 10 to 100 MeV), heliocentric distance, and phase of the solar cycle are included. The techniques are described and applied to the Mariner Jupiter/Saturn 1977 mission.

Divine, N.↗

Interaction lengths of energetic pions and protons in iron.

Determination of the mean interaction lengths for 9.3-, 13.8-, and 17.8-GeV protons and 9.3- and 17.8-GeV positive pions in iron. The mean interaction length of pions is found to be approximately 20% greater than that of protons. No statistically significant variation of the mean interaction length for protons or pions as a function of energy is observed. With only two exceptions, the data obtained show a systematic 5% difference between measurements of the mean interaction length made with cosmic rays and those made with accelerator-produced protons.

Crannell, H.↗

Access of solar protons to the earth's polar caps.

Energetic solar proton observations in the interplanetary medium by Explorer 33 and Explorer 35 and over the polar caps by Injun 5 during the period from September 1968 through March 1970 have been examined in detail. The solar proton intensities observed over the polar regions were compared with the interplanetary intensities on an absolute basis. The high polar latitude (HPL) proton intensities tracked the magnetic field aligned interplanetary intensities well (solar-antisolar intensities as determined from the sectored Explorer data). The tracking was in agreement with the open magnetosphere model about 90% of the time - i.e., the intensities observed on the HPL magnetic lines of force, which would be connected to magnetic lines of force from the sun in an interconnected geomagnetic and interplanetary magnetic field, were in agreement with the maximum intensity of the interplanetary proton pitch angle distribution. The intensities observed at the HPL region of the opposite polar cap were in agreement with the minimum intensity of the interplanetary pitch angle distribution. The low polar latitude intensities generally tracked the maximum interplanetary intensity very well.

Fennell, J. F.↗

Energy spectra and pitch angle distributions of storm-time and substorm injected protons.

Discussion of the energy spectra and pitch angle distributions of ring current protons observed with the solid-state proton detector of Explorer 45 during the main and fast recovery phases of a storm on Dec. 17, 1971. Appearances of characteristic changes in the pitch angle distributions of roughly 100-eV protons are interpreted as pitch angle dispersion of rapidly injected protons during their azimuthal drift at L values above 5.

Konradi, A.↗

ATS-5 observations of energetic proton injection

Energetic particle observations from ATS-5 are presented that directly show asymmetric injection of 30- to 300-keV proton fluxes into the nightside magnetosphere to form the asymmetric ring current. The temporal structure of these substorm-correlated proton bursts is consistent with a westward gradient drift from the nightside acceleration region. The drifting protons tend to be accompanied by nondiamagnetic decreases of the magnetic field at the satellite. Adiabatic decreases of the energetic electron fluxes often occur with these changes in the field strength. Nearly 200 proton-only events have been observed, occurring uniformly between 1500 and 2200 LT and not at all before 1200 LT or after 2300 LT.

Bogott, F. H.↗