Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse Reactor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Optical transmission of glass for the National Ignition Facility near backscatter imagers under x-ray exposure

In experiments at the National Ignition Facility (NIF), the near backscatter imager materials need to maintain high optical transmission while exposed to hohlraum generated x rays. Glass plates are incorporated in the design to protect the optical scattering plates from x-ray damage. Radiation environments spanning those expected on NIF have been produced at the Omega Laser Facility by symmetric laser illumination of 1 mm sized gold spheres. The time-dependent ultraviolet transmission of sample glass plates was measured. The data are interpreted with a free electron absorption model. Combined with the simulations of the hohlraum x-ray emission, this model is used to predict the transmission of the glass plates on the NIF. We predict that the plates should perform adequately up to the peak of the laser pulse.

36 MATERIALS SCIENCE↗

Absolute calibration of microfission chamber in JT-60U

We have conducted calibrations of a microfission chamber, which was installed between the vacuum vessel and the toroidal field coils, by both a Cf-252 neutron source and real deuterium plasmas in JT-60U. The detector employs both pulse counting and Campbell (mean square voltage) modes in the electronics to cover a wide dynamic range of the neutron source strength. The pulse counting and Campbell modes were calibrated by Cf-252 and deuterium plasmas, respectively. Point efficiencies, counts per neutron from a point at a single angle, were measured for 27 locations of the neutron point source in toroidal scan. The efficiencies were influenced by the various components such as the vacuum vessel, port, and graphite tiles. The point efficiencies can be integrated and averaged with angle to provide toroidal line efficiencies. The line efficiencies of the microfission chamber and the nearest neutron monitor of the U-235 fission chamber were 5.38x10{sup -9} and 1.77x10{sup -8}, respectively. Then the calibration for the Campbell mode was also performed by using a real deuterium plasma. The detection efficiency in the Campbell mode was about three-tenths of that of the nearest neutron monitor, which is consistent with the calibration result obtained by using a Cf-252 neutron source for pulse counting mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficient source for the production of ultradense deuterium D(-1) for laser-induced fusion (ICF)

A novel source which simplifies the study of ultradense deuterium D(-1) is now described. This means one step further toward deuterium fusion energy production. The source uses internal gas feed and D(-1) can now be studied without time-of-flight spectral overlap from the related dense phase D(1). The main aim here is to understand the material production parameters, and thus a relatively weak laser with focused intensity {<=}10{sup 12} W cm{sup -2} is employed for analyzing the D(-1) material. The properties of the D(-1) material at the source are studied as a function of laser focus position outside the emitter, deuterium gas feed, laser pulse repetition frequency and laser power, and temperature of the source. These parameters influence the D(-1) cluster size, the ionization mode, and the laser fragmentation patterns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Modeling of Vacuum Pumping for Steady-State Pellet Fueling Systems

We report that future long-pulse magnetic confinement fusion reactors will require density and isotopic mixture control using steady-state repeating pellet injectors. For high-energy density burning plasmas, pellet velocities of 1 km/s and above will be required for sufficient plasma penetration to achieve high fueling efficiency. Currently, steady-state repeating injection systems utilize cryogenic extruder systems to produce an extrusion of solid deuterium or deuterium-tritium. In repeating light gas gun injectors, the solid extrusion is cut and simultaneously loaded into a barrel. Once loaded, a fast operating gas valve delivers a high pressure burst of gas to accelerate the pellet down the barrel and into the machine. This process takes ~10 ms to achieve. Adequate gas pumping of the extruder exhaust and injection line propellant gas collection chambers is necessary for optimal operation of the pellet fueling system. Excess solid from the extruder sublimates in an exhaust chamber. The gas pressure in the extruder exhaust chamber must remain low to maintain low heating loads on the cooling mechanism (cryorefrigerators or liquid helium flow) and to reduce thermal conduction to the extrusion. Pumping the injection line chambers is necessary to limit propellant gas flow into the machine. A numerical simulation code was created to predict temporal pumping performance for these repeating pellet injection systems. Lastly, this paper outlines the methods and assumptions used to create this model and compares results to the pellet injection system currently employed on DIII-D, the steady-state pellet injection system planned for the Wendelstein 7-X, and a brief analysis of the ITER conceptual pellet fueling system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward Verification of RANS Simulations of the T-Tube Modular Divertor Using Large Eddy Simulations of Impinging Turbulent Plane Jets

Turbulent impinging jets have been proposed to cool high heat flux plasma-facing components such as the solid tungsten target plates of the divertor in long-pulse magnetic fusion energy reactors. In particular, the T-tube modular divertor, originally developed by the ARIES Team, consists of two concentric cylindrical tubes where helium flows through a slot in the inner tube, forming an approximately planar jet that impinges upon and cools the inner surface of the pressure boundary (namely, the outer tube) and the ~15-cm 2 plasma-facing W target. The objective of this work is to demonstrate that large eddy simulations (LESs) accurately simulate the thermal transport in canonical flows that comprise the cooling flow in the T-tube, as well as validate temperatures from LES with experimental measurements in a simplified T-tube geometry. Wall‑resolved LESs, validated by experimental data and verified by direct numerical simulations (DNSs), provide benchmark data for two canonical flows in the T‑tube, namely, planar impinging and wall jets, for Reynolds numbers Re B = 4 × 10 3 to 2 × 10 4 . Our LES results are within 4% to 12% root-mean-square error (RMSE) of surface Nusselt number distributions (Nu) from experiments and DNSs. The validated LES results are then used as the ground truth to evaluate four Reynolds‑averaged Navier-Stokes (RANS) turbulence closures, namely, the k‑ω SST, realizable k‑ε, GEKO, and γ‑SST models. The k‑ω SST model has the best overall performance in terms of heat transfer, giving surface Nu within 12% RMSE of the LES results for high‑ReB impinging jets and reduced overprediction in the wall‑jet region. The GEKO model with default constants has the next best performance, providing slightly better Nu predictions for low ReB impinging jets (versus k-ω SST) but worse overall performance over the full range of ReB studied here. The realizable k‑ε turbulence model significantly overestimates turbulence near the stagnation point, while the γ‑SST model suppresses near‑wall production, biasing the simulations toward simulating laminar surface heat transfer. Simulations of the simplified T‑tube show that LES and RANS simulations with the k‑ω SST model give nearly identical average heat transfer coefficients (HTCs) over the impingement surface. The realizable k‑ε model predicts significantly lower wall temperatures due to overestimation of HTC in the outlet flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vacuum Ultraviolet Photoionization of Complex Chemical Systems

Tunable vacuum ultraviolet (VUV) radiation coupled to mass spectrometry is applied to the study of complex chemical systems in this paper. The identification of novel reactive intermediates and radicals is revealed in flame, pulsed photolysis, and pyrolysis reactors, leading to the elucidation of spectroscopy, reaction mechanisms, and kinetics. Mass-resolved threshold photoelectron photoion coincidence measurements provide unprecedented access to vibrationally resolved spectra of free radicals present in high-temperature reactors. Photoionization measurements in water clusters, nucleic acid base dimers, and their complexes with water provide signatures of proton transfer in hydrogen-bonded and π-stacked systems. Experimental and theoretical methods to track ion–molecule reactions and fragmentation pathways in intermolecular and intramolecular hydrogen-bonded systems in sugars and alcohols are described. Photoionization of laser-ablated molecules, clusters, and their reaction products inform thermodynamics and spectroscopy that are relevant to astrochemistry and catalysis. Finally, new directions in coupling VUV radiation to interrogate complex chemical systems are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sulfur Pellets Responses to a Bare and Steel Reflected Pulse of the Oak Ridge National Laboratory Health Physics Research Reactor

The experiments analyzed in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the $\textit{Fast Burst Reactor}$. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. The HPRR was an unmoderated, unshielded fast reactor that used highly enriched uranium and molybdenum alloy as fuel. The reactor was initially sent to the Nevada Test Site in 1962, where it was used to evaluate radiation doses received as a result of the Hiroshima and Nagasaki bombings during World War II. A few years later, the reactor was sent back to ORNL to be part of the Dosimetry Application Research (DOSAR) facility shown in Figure 1, which included a reactor building shown on the left (west) of the picture and a control and laboratory building in the upper right corner (northeast). The critical assembly was used for numerous technical studies, including systems calibration, dosimetry, radiobiology of plants and animals, testing of radiation alarms, as well as teaching and training in radiation dosimetry and nuclear engineering. Between 1963 and 1987, the HPRR was operated for thousands of hours, achieving criticality close to 10,000 times and motivating many publications. The HPRR was decommissioned in 1987. The goal of this effort was to use historical data from operation of the HPRR to create a criticality accident alarm system (CAAS) benchmark to be included in the $\textit{International Handbook of Evaluated Criticality Safety Benchmark Experiments}$ (ICSBEP Handbook). A thorough inspection was performed of all available documentation and information available. The most promising experiments that were selected for evaluation were those described in the 1987 ORNL report entitled $\textit{Health Physics Research Reactor Reference Dosimetry}$, ORNL-6240. The report includes reference dosimetry results of the shielded and unshielded configurations of the HPRR after burst operations. Because of changes to the reactor positioning and storage systems that were made in 1985, the previous dosimetry reports became obsolete, and the newly designed experiments were needed to create the HPRR’s adjusted dosimetry data. The various results reported in ORNL-6240 include reference doses and dose equivalents from different conventions at different distances and elevations as determined using the detected neutron fluence and conversion factors. The HPRR neutron fluence was obtained through different methods, including sulfur pellet analysis and threshold detector unit data. Information about the HPRR spectrum was also obtained through Bonner sphere measurements. This benchmark is focused on a part of the measured sulfur fluences reported in Appendix H of ORNL-6240. Standard commercial sulfur pellets were placed at different distances from the HPRR centerline during burst operation and were activated due to the 32 S(n,p) 32 P reaction. The resulting 32 P activity was then measured and the information about the corresponding sulfur fluence and/or neutron dose could be extracted. Many of those measurements have 7 been performed with the HPRR in its bare configuration or with different shields (combinations of Lucite, concrete, steel). All the necessary, precise information about material and/or dimensions of the different shields was not found, so it was decided to focus only on the unshielded and steel-shielded configurations to minimize the benchmark uncertainty. A total of 31 cases (24 unshielded and 7 shielded cases at different positions) of sulfur fluence were selected before evaluation to develop the benchmark.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An ultrasonic method for studying elastic moduli as a function of temperature

Ultrasonic method is used to determine the elastic moduli of materials used in components of high-temperature nuclear reactors. An ultrasonic, pulse-echo technique determines the velocity of sound waves propogating in a heated region of rod-shaped specimens. From these velocities, the elastic moduli are calculated.

Peterson, R. G.↗

Electronics Upgrades to the Green is Clean Phoswich Detector Systems and Programmatic Implementation at LANL - Phase II Completion - 18403

Los Alamos National Laboratory (LANL) radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to verify that GIC candidate low-density waste contains no radioactivity above background. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. The electronics currently in use by the systems are out of date and some components are no longer manufactured. In 2015, phase I upgrades to the GIC detector systems were completed. Phase I objectives included identifying more modern commercially available electronics that could replace the NIM electronics. A pulse shape discriminator (PSD) module, the Digital Gamma Finder (DGF) Pixie-4 made by XIA LLC, that fits in a compact National Instruments{sup TM} PXI chassis was identified to replace the majority of the original NIM bin electronics - a single Pixie-4 module replaces four NIM amplifiers and four NIM pulse shape analyzers (PSAs). Another phase I objective was to show that that new PSD could separate out the NaI and CsI detector signals in a manner equivalent to or better than the NIM electronics. Proof of concept was achieved in 2015 when a prototype upgrade system on ZEUS was built and tested and gating parameter settings were determined that successfully separated the NaI and CsI signals. Phase II required establishing a LabVIEW software interface with Pixie-4 electronics in lieu of the manufacturer provided Pixie-4 software called the Pixie Viewer. In addition, phase II included 1) final optimization of the gating parameters on the prototype Pixie-4 ZEUS system, 2) finalizing Requirements, Design and Test Plan documents, 3) LabVIEW software interface quality assurance (QA) testing, 4) setting up the HERCULES system with the Pixie-4 upgrade electronics, 5) check source and background calibration of both systems, 6) absolute efficiency determination on both systems and 7) procedure revisions and implementation of both systems into routine operations. In 2017 phase II was completed including the preparation of detailed Requirements, Design and Test Plan documents. The LabVIEW interface software that communicates and controls the Pixie-4 has been completed, merged with the preexisting LabVIEW operations software and fully tested. Gating parameter optimization, configuration of HERCULES with the Pixie-4 electronics, check source and background calibrations and absolute efficiency determinations have all been performed - quantitative results are presented in the full paper. For performance validation, comparison measurements of actual GIC bags on both the HERCULES system using the old NIM Bin electronics and the ZEUS system using the upgraded Pixie-4 electronics have been done and evaluated. Finally, procedure revisions and implementation of both systems into routine operations is currently in process and planned to be complete by the end of calendar year 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resistance heater rod and method of making such

A resistive heater capable of delivering heat loads on the same order as those produced by in-pile nuclear fuel experiments. The heater rod provides the energy for high-temperature steady-state testing, as well as the power needed to simulate the transient pulse in the Transient Reactor Test Loop (TRTL) system. The resistive heater includes a removable housing, two or more thermal conductors in the housing; and one or more stabilizers coupled to the two or more thermal conductors to keep the two or more thermal conductors separated to avoid shorting, wherein the two or more thermal conductors are coupled to the housing via an inert gas (e.g., Helium). The two or more thermal conductors comprise a material with substantially zero infrared spectrum (e.g., sapphire, silica, or glass).

LaBrier, Daniel↗

Pulsed high-density plasmas for advanced dry etching processes

Plasma etching processes at the 22 nm technology node and below will have to satisfy multiple stringent scaling requirements of microelectronics fabrication. To satisfy these requirements simultaneously, significant improvements in controlling key plasma parameters are essential. Pulsed plasmas exhibit considerable potential to meet the majority of the scaling challenges, while leveraging the broad expertise developed over the years in conventional continuous wave plasma processing. Comprehending the underlying physics and etching mechanisms in pulsed plasma operation is, however, a complex undertaking; hence the full potential of this strategy has not yet been realized. In this review paper, we first address the general potential of pulsed plasmas for plasma etching processes followed by the dynamics of pulsed plasmas in conventional high-density plasma reactors. The authors reviewed more than 30 years of academic research on pulsed plasmas for microelectronics processing, primarily for silicon and conductor etch applications, highlighting the potential benefits to date and challenges in extending the technology for mass-production. Schemes such as source pulsing, bias pulsing, synchronous pulsing, and others in conventional high-density plasma reactors used in the semiconductor industry have demonstrated greater flexibility in controlling critical plasma parameters such as ion and radical densities, ion energies, and electron temperature. Specifically, plasma pulsing allows for independent control of ion flux and neutral radicals flux to the wafer, which is key to eliminating several feature profile distortions at the nanometer scale. However, such flexibility might also introduce some difficulty in developing new etching processes based on pulsed plasmas. Therefore, the main characteristics of continuous wave plasmas and different pulsing schemes are compared to provide guidelines for implementing different schemes in advanced plasma etching processes based on results from a particularly challenging etch process in an industrial reactor.

36 MATERIALS SCIENCE↗

Investigation of a catalytic gas generator for the Space Shuttle APU

An investigation was conducted to establish the capability of a monopropellant hydrazine catalytic gas generator to meet the requirements specified for the Space Shuttle APU. Detailed analytical and experimental studies were conducted on potential problem areas including long-term nitriding effects on materials, design variables affecting catalyst life, vehicle vibration effects, and catalyst oxidation/contamination. A full-scale gas generator, designed to operate at a chamber pressure of 750 psia and a flow rate of 0.36 lbm/sec, was fabricated and subjected to three separate life test series. The objective of the first test series was to demonstrate the capability of the gas generator to successfully complete 20 simulated Space Shuttle missions in steady-state operation. The gas generator was then refurbished and subjected to a second series of tests to demonstrate the pulse-mode capability of the gas generator during 20 simulated missions. The third series of tests was conducted with a refurbished reactor to further demonstrate pulse-mode capability with a modified catalyst bed.

Emmons, D. L.↗

KGK-2-type detector of gamma-radiation power for diagnosis of nuclear reactor radiation fields within the range from 1 µGy/s to 100 Gy/s

The construction of the KGK-2-type detector of γ-radiation power is briefly described. The diagnostic possibilities of the detector are shown by the example of results of the dose rate measurement in the energy start-ups of the BR-K1 and BR-1M reactors implemented in the mode of generating fission pulses on delayed neutrons. The possibilities of using the KGK-2 detector for postpulse γ diagnostics are demonstrated by the example of results of measurements in the fission pulse on prompt neutrons of the BR-1M reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiation characterization summary of the NETL beam port 1/5 free-field environment at the 128-inch core centerline adjacent location

The characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields in the University of Texas at Austin Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor for the beam port (BP) 1/5 free-field environment at the 128-inch location adjacent to the core centerline has been accomplished. NETL is being explored as an auxiliary neutron test facility for the Sandia National Laboratories radiation effects sciences research and development campaigns. The NETL reactor is a TRIGA Mark-II pulse and steady-state, above-ground pool-type reactor. NETL is intended as a university research reactor typically used to perform irradiation experiments for students and customers, radioisotope production, as well as a training reactor. Initial criticality of the NETL TRIGA reactor was achieved on March 12, 1992, making it one of the newest test reactor facilities in the US. The neutron energy spectra, uncertainties, and covariance matrices are presented as well as a neutron fluence map of the experiment area of the cavity. For an unmoderated condition, the neutron fluence at the center of BP 1/5, at the adjacent core axial centerline, is about 8.2×10 12 n/cm 2 per MJ of reactor energy. About 67% of the neutron fluence is below 1 keV and 22% above 100 keV. The 1-MeV Damage-Equivalent Silicon (DES) fluence is roughly 1.6×10 12 n/cm 2 per MJ of reactor energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of RELAP5-3D for transient analysis of a dual coolant lead lithium fusion blanket concept

Our research aims to build a multiphysics framework for transient analysis of the Dual- Coolant Lead-Lithium (DCLL) blanket design of the proposed Fusion Nuclear Science Facility (FNSF) for all Onticipated Operational Occurrences (AOOs) using Reduced Order Models (ROMs). This paper presents an assessment of using RELAP5-3D for transient thermal-hydraulic blanket analysis of the DCLL design. Preliminary validation studies for the RELAP5-3D properties were conducted using a representative vertical flow loop model and a comparison study using experimental data from the thermal convection corrosion loops at ORNL. These studies inspected the thermal hydraulic response of Lead-Lithium Eutectic (PbLi) systems within the RELAP5-3D code; mainly pressure drop and heat transfer, as compared to analytical calculations and experimental data. The Magnetohydrodynamic (MHD) pressure drop effect for liquid metal under the effects of a uniform magnetic field was implemented into our models using an equivalent forms loss coefficient based on the phasic momentum equations. We verified our implementation of MHD pressure drop within RELAP5-3D using a systematic approach consisting of two studies. Models were developed to perform comparison studies based on experimental data from the Argonne Liquid metal EXperiment (ALEX) facility and the Magnetohydrodynamic PbLi Experiment (MaPLE) facility. Using the developed validation basis, we built a simplified DCLL channel model within RELAP5-3D, inspected MHD pressure drop and performed transient temperature analysis. The DCLL channel model used radial heating data from the International Thermonuclear Experimental Reactor (ITER) which was normalized to the FNSF design. Here, a representative startup transient was performed using a relative power curve from the initial ramp up of a long-term power pulse of the Tore Supra reactor. This study demonstrated that RELAP5-3D ROMs are capable of accurate transient analysis of the DCLL blanket. We have since utilized MCNP to develop heating profiles based on the FNSF design and are working toward implementing them into our DCLL model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental results from the VENUS-F critical reference state for the GUINEVERE accelerator driven system project

The GUINEVERE (Generation of Uninterrupted Intense Neutron pulses at the lead Venus Reactor) project was launched in 2006 within the framework of FP6 EUROTRANS in order to validate online reactivity monitoring and subcriticality level determination in accelerator driven systems (ADS). Therefore, the VENUS reactor at SCK.CEN in Mol, Belgium, was modified towards a fast core (VENUS-F) and coupled to the GENEPI-3C accelerator built by CNRS. The accelerator can operate in both continuous and pulsed mode. The VENUS-F core is loaded with enriched Uranium and reflected with solid lead. A well-chosen critical reference state is indispensable for the validation of the online subcriticality monitoring methodology. Moreover, a benchmarking tool is required for nuclear data research and code validation. In this paper, the design and the importance of the critical reference state for the GUINEVERE project are motivated. The results of the first experimental phase on the critical core are presented. The control rods worth is determined by the positive period method and the application of the Modified Source Multiplication (MSM) method allows the determination of the worth of the safety rods. The results are implemented in the VENUS-F core certificate for full exploitation of the critical core. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗