Search NASA⌕ Search

SEARCH · Search NASA

Results for “QUALITY ASSURANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Innovative Technologies for Efficient Pharmacotherapeutic Management in Space

Current and future Space exploration missions and extended human presence in space aboard the ISS will expose crew to risks that differ both quantitatively and qualitatively from those encountered before by space travelers and will impose an unknown risk of safety and crew health. The technology development challenges for optimizing therapeutics in space must include the development of pharmaceuticals with extended stability, optimal efficacy and bioavailability with minimal toxicity and side effects. Innovative technology development goals may include sustained/chronic delivery preventive health care products and vaccines, low-cost high‐efficiency noninvasive, non‐oral dosage forms with radio‐protective formulation matrices and dispensing technologies coupled with self‐reliant tracking technologies for quality assurance and quality control assessment. These revolutionary advances in pharmaceutical technology will assure human presence in space and healthy living on Earth. Additionally, the Joint Commission on Accreditation of Healthcare Organizations advocates the use of health information technologies to effectively execute all aspects of medication management (prescribing, dispensing, and administration). The advent of personalized medicine and highly streamlined treatment regimens stimulated interest in new technologies for medication management. Intelligent monitoring devices enhance medication accountability compliance, enable effective drug use, and offer appropriate storage and security conditions for dangerous drug and controlled substance medications in remote sites where traditional pharmacies are unavailable. These features are ideal for Exploration Medical Capabilities. This presentation will highlight current novel commercial off‐the‐shelf (COTS) intelligent medication management devices for the unique dispensing, therapeutic drug monitoring, medication tracking, and drug delivery demands of exploration space medical operations.

Putcha, Lakshmi↗

New developments and verification of fusion blanket simulation capabilities in the MOOSE framework

Multiphysics modeling capabilities have a crucial role to play in the accelerated deployment of fusion energy. To that end, we developed new multiphysics fusion blanket simulation capabilities in the Multiphysics Object-Oriented Simulation Environment (MOOSE). Firstly, we expanded on the existing capabilities of the previously published work, by coupling 3D tritium transport modeling capabilities using the Tritium Migration Analysis Program, version 8 (TMAP8) to an existing tool including thermal hydraulics, fully three-dimensional (3D) heat transfer, and loosely coupled neutronics analysis. Secondly, we performed a thorough verification of the new capabilities and increased testing code coverage to meet MOOSE’s software quality standards. The MOOSE framework follows a strict software quality assurance plan to be Nuclear Quality Assurance, Level 1 compliant. The new multiphysics fusion blanket simulation capabilities are now held to the same standard. Thirdly, to demonstrate MOOSE’s new fusion blanket modeling capabilities, we performed a fully integrated, multiphysics simulation of a 3D solid ceramic breeder blanket design. This proof-of-concept simulation provides the temperature and tritium distribution across the blanket. In conclusion, the combined efforts towards software quality and the development of multiphysics coupling capabilities provide an effective and reliable framework for modeling solid ceramic fusion blankets using MOOSE.

modeling and simulation↗

Quality and security - They work together

This paper describes the importance of considering computer security as part of software quality assurance practice. The intended audience is primarily those professionals involved in the design, development, and quality assurance of software. Many issues are raised which point to the need ultimately for integration of quality assurance and computer security disciplines. To address some of the issues raised, the NASA Automated Information Security program is presented as a model which may be used for improving interactions between the quality assurance and computer security community of professionals.

Carr, Richard↗

Recommendations for developing, documenting, and distributing data products derived from NEON data

The National Ecological Observatory Network (NEON) provides over 180 distinct data products from 81 sites (47 terrestrial and 34 freshwater aquatic sites) within the United States and Puerto Rico. These data products include both field and remote sensing data collected using standardized protocols and sampling schema, with centralized quality assurance and quality control (QA/QC) provided by NEON staff. Such breadth of data creates opportunities for the research community to extend basic and applied research while also extending the impact and reach of NEON data through the creation of derived data products—higher level data products derived by the user community from NEON data. Derived data products are curated, documented, reproducibly-generated datasets created by applying various processing steps to one or more lower level data products—including interpolation, extrapolation, integration, statistical analysis, modeling, or transformations. Derived data products directly benefit the research community and increase the impact of NEON data by broadening the size and diversity of the user base, decreasing the time and effort needed for working with NEON data, providing primary research foci through the development via the derivation process, and helping users address multidisciplinary questions. Creating derived data products also promotes personal career advancement to those involved through publications, citations, and future grant proposals. However, the creation of derived data products is a nontrivial task. Here we provide an overview of the process of creating derived data products while outlining the advantages, challenges, and major considerations.

54 ENVIRONMENTAL SCIENCES↗

Methods development towards automated, physics-informed, quantitative quality control of TRISO-SiC

Tristructural-isotropic (TRISO) fuel particles have been developed as a high-performance fuel for use in high-temperature gas-cooled reactor (HTGR) systems due to their high efficiency and stability under both normal and off-normal conditions. Broader deployment of this technology in advanced nuclear applications may benefit from quantitative quality assurance and quality control (QA/QC) methods that directly link TRISO properties to downstream performance. A key TRISO property is the SiC layer microstructure, which influences fission product retention during irradiation. However, existing QA/QC for the TRISO-SiC microstructure comprises only a qualitative visual inspection; therefore, there is a clear opportunity for the development of quantitative methods for TRISO QA/QC. Here, to this end, previous work has demonstrated an image processing approach to grain boundary (GB) identification and subsequent extraction of microstructural metrics; however, extensive twinning within the SiC layer complicates such analyses because twin GBs significantly influence microstructural metrics but are not expected to contribute to fission product transport. This study presents the initial development, training, and testing of an ML-based image segmentation algorithm designed to identify and remove twin GBs from standard backscattered electron micrographs, providing an industrially applicable, quantitative, and physically meaningful QA/QC approach for the TRISO-SiC microstructure. Although pixel-wise performance metrics for the twin predictions are low, the change in grain area and the number of GB pixels after twin removal predicted by the ML workflow are within 1% of the true values calculated using crystallographic data. This suggests that the model is well capable of predicting overall twin boundary structures and grain morphology, and continued advancement of this approach could enable automated, scalable, and physics-informed QA/QC for TRISO-SiC microstructures, supporting the reliable qualification of coated particle fuels for next-generation reactor systems.

Computer vision↗

Advancing Reel-to-Reel Inspection Techniques for Long HTS Conductors: Comparison and Innovations

The continuous advancement of high-temperature superconductor (HTS) technologies has greatly accelerated the development and deployment of HTS applications. Among the critical tools supporting these advancements are reel-to-reel (R2R) critical current (I c ) measurement techniques, which are extensively used by both manufacturers and end users to characterize long-length REBCO conductors. These techniques play a vital role in quality assurance and quality control (QA/QC), ensuring the reliability and performance of HTS conductors and applications throughout the production cycle. We have developed a range of in-house devices for R2R measurements at the University of Houston and Princeton Plasma Physics Laboratory. These include one-dimensional (1D) scan using a magnetic circuit (MC) and two-dimensional (2D) magnetic field mapping systems based on scanning probe array microscope (SPAM) or scanning probe microscopy (SPM). Each technique offers distinct advantages: the MC system provides ultra-fast scanning speeds, ideal for rapid inspection in large-scale industrial production; the high-resolution SPM delivers detailed insights for conductor research and development; and the SPAM, with its simpler mechanical setup, can be upgraded for higher field and lower temperature conditions with a balanced 2D resolution. Here we compared the magnetization and detection capabilities of these techniques through experiments on rare-earth barium copper oxide (REBCO) coated conductor samples, with data analysis supported by numerical simulations. Based on our comprehensive comparative studies, we propose enhancements for each measurement system and provide guidelines for selecting the optimal technique combinations to meet specific application requirements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Efforts to enhance reproducibility in a human performance research project

Background: Ensuring the validity of results from funded programs is a critical concern for agencies that sponsor biological research. In recent years, the open science movement has sought to promote reproducibility by encouraging sharing not only of finished manuscripts but also of data and code supporting their findings. While these innovations have lent support to third-party efforts to replicate calculations underlying key results in the scientific literature, fields of inquiry where privacy considerations or other sensitivities preclude the broad distribution of raw data or analysis may require a more targeted approach to promote the quality of research output. Methods: We describe efforts oriented toward this goal that were implemented in one human performance research program, Measuring Biological Aptitude, organized by the Defense Advanced Research Project Agency's Biological Technologies Office. Our team implemented a four-pronged independent verification and validation (IV&V) strategy including 1) a centralized data storage and exchange platform, 2) quality assurance and quality control (QA/QC) of data collection, 3) test and evaluation of performer models, and 4) an archival software and data repository. Results: Our IV&V plan was carried out with assistance from both the funding agency and participating teams of researchers. QA/QC of data acquisition aided in process improvement and the flagging of experimental errors. Holdout validation set tests provided an independent gauge of model performance. Conclusions: In circumstances that do not support a fully open approach to scientific criticism, standing up independent teams to cross-check and validate the results generated by primary investigators can be an important tool to promote reproducibility of results.

59 BASIC BIOLOGICAL SCIENCES↗

Total Dissolved Nitrogen and Ammonia Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for total dissolved nitrogen (TDN) and ammonia concentrations for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. TDN was analyzed using a Shimadzu Total Nitrogen Module (TNM-1) combined with the TOC-VCSH analyzer (Shimadzu Corporation, Japan). TNM-1 is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. Ammonia was determined using a Lachat's QuikChem 8500 Series 2 Flow Injection Analysis System (LACHAT Instruments, QuckChem 8500 series 2, Automated Ion Analyzer, Loveland, Colorado). When ammonia in water samples is heated (60 degrees C) with salicylate and hypochlorite in an alkaline phosphate buffer, an emerald green color is produced which is proportional to the ammonia concentration. The color is intensified by the addition of nitroprusside. Ethylenediaminetetraacetic acid (EDTA) is added to the buffer to prevent the interference of metal ions (Ca, Mg, and Fe etc.). Ammonia-N is then determined by LACHAT flow injection and a colorimetric assay at an absorbance wavelength 660 nm. (Reference: LACHAT Instruments: QuickChem Method 90-107-06-3-A, Determination of Ammonia by Flow Injection Analysis (High Throughput, Salicylate Method/DCIC) (Multi Matrix method). Written by Lynn Egan (Application group), February 08, 2011.) All files are labeled by location and variable, and data reported are the mean values upon replicate measurements. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process as detailed in the methods. This data package contains (1) a zip file (tdn_ammonia_data_2015-2025.zip) containing a total of 299 files: 298 data files of ammonia and TDN data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v7_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v7_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the determination of Method Detection Limits (MDLs) for TDN data, which has been updated in 2026-08; and (5) PDF and docx files for the detemination of Method Detection Limits (MDLs) for Ammonia and the Interferences by LACHAT Flow Injection Analysis. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 105 locations containing TDN and Ammonia-N data. Update 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses and Determination of Method Detection Limit for Ammonia and the Interferences by LACHAT Flow Injection Analysis documents, which can be accessed as PDFs or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated total dissolved nitrogen and ammonia data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2022-12-20: Updates were made to both the data files and reporting format specific files. Units were listed incorrectly, but have been fixed to reflect correct units (ug/L). File level metadata (flmd) and data dictionary (dd) files were updated to reflect the updated versions of these files. Available data was added up until 2022-06-01. Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-27. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for TDN were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for TDN data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗

Dissolved Inorganic Carbon and Dissolved Organic Carbon Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for dissolved organic carbon (DOC) and dissolved inorganic carbon (DIC) for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. DOC and DIC concentrations in water samples were determined using a TOC-VCPH analyzer (Shimadzu Corporation, Japan). DOC was analyzed as non-purgeable organic carbon (NPOC) by purging HCl-acidified samples with carbon-free air to remove DIC prior to measurement. After the acidified sample has been sparged, it is injected into a combustion tube filled with oxidation catalyst heated to 680 oC. The DOC in samples is combusted to CO2 and measured by a non-dispersive infrared (NDIR) detector. The peak area of the analog signal produced by the NDIR detector is proportional to the DOC concentration of the sample. DIC was determined by acidifying the samples with HCl first, and then purging with carbon-free air to release CO2 for analysis by NDIR detector. Total dissolved nitrogen (TDN) was analyzed using a Shimadzu Total Nitrogen Module (TNM-L) combined with the TOC-L analyzer (Shimadzu Corporation, Japan). TNM-L is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. All data reported are the mean values upon minimum of three replicate measurements, with a relative standard deviation < 3%. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (dic_npoc_data_2014-2025.zip) containing a total of 337 files: 336 data files of DIC and NPOC data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20250901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20250901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; and (4) PDF and docx files for the determiniation of Method Detection Limits (MDLs) for DIC and NPOC data, which has been updated in 2026-08. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing DIC/NPOC data. Update on 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update on 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses document, which can be accessed as a PDF or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated dissolved inorganic carbon and dissolved organic carbon data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-11-21. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for DIC and NPOC were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available DIC and NPOC data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available DIC and NPOC data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for DIC and NPOC data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗

Cation Data for the East River Watershed, Colorado (2014-2025)

This data package contains mean values for cation concentration for water samples taken from the East River Watershed in Colorado. Inductively coupled plasma mass spectrometry (ICP-MS) has been used to measure the concentrations of elements of interest simultaneously for the East River Watershed, Colorado groundwater and surface water samples to inform insights on the biogeochemistry processes within the watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. For samples collected prior to 06-16-2021, the instrumentation, Elan DRC II, PerkinElmer SCIEX, automatically switches among the three models necessary to analyze all 37 elements. These 37 elements include: (1) Lithium (Li), Beryllium (Be), Boron (B), Sodium (Na), Magnesium (Mg), Aluminium (Al), Silicon (Si), Phosphorus (P), Titanium (Ti), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Caesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th), Uranium (U) using standard model, argon Ar as reaction gas, (2) Potassium (K), Calcium (Ca), Vanadium (V), Chromium (Cr), Manganese (Mn), Iron (Fe) using dynamic reaction cell (DRC) model, ammonia NH3 as reaction gas, and (3) Phosphorus (P) and Selenium (Se) using DRC model, oxygen O2 as reaction gas. Note for the samples with higher concentrations of chloride (Cl-), asenic (As) concentrations were analysed with DRC model (oxygen O2 as reaction gas) to avoid the interference of chloride. For samples collected on and after 06-16-2021, an advanced Agilent 8900 triple quadrupole inductively coupled plasma mass spectrometry system (Agilent 8900 QQQ ICP-MS, Agilent Technologies) has been used to measure the concentrations of interested 36 elements simultaneously for environmental samples, including (1) Lithium (Li), Beryllium (Be) and Boron (B) using standard no gas mode, (2) Sodium (Na), Magnesium (Mg), Aluminium (Al) Phosphorus (P), Potassium (K), Chromium (Cr), Manganese (Mn), Iron (Fe), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Cesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th) and Uranium (U) using standard helium (He) collision mode, (3) Titanium (Ti) and Vanadium (V) using high Energy (HEHe) helium (He) collision mode, and (4) Silicon (Si), Calcium (Ca) and Selenium (Se) using standard H2 reaction mode. All samples were prepared/diluted with 2% (v/v) ultrapure nitric acid in Milli-Q water (18.2 mega ohm-cm), and analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (cation_data_2014_2025.zip) containing a total of 5,849 files: 5.848 data files of cation data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the detemination of Method Detection Limits (MDLs) for ICP-MS PerkinElmer DRC II instrumentation (Detemination_of_Method_Detection_Limits__MDLs__for_ICP_MS__PerkinElmer_Elan_DRC_II__LBL_Bldg74_Lab214D) for samples before November 2021; (5) PDF and docx files for the determination of MDLs for ICP-MS Agilent 8900 QQQ instrumentation (ICP_MS_Analysis_detection_limits_and_QA_QC_WenmingDong_updated_2026-08-06) for samples November 2021 and onward. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing cation data. Update on 2021-04-11: Added Detemination of Method Detection Limits (MDLs) for ICP-MS document, which can be accessed as a PDF or with Microsoft Word. Update on 2022-06-10: versioned updates to this dataset was made along with these changes: (1) updated cation data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) removed suffix and prefix on two variables (“aqberylliumion_asberyllium” and “aqlithiumion_aslithium”), (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-16. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Updated versions of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-06, of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021.

54 ENVIRONMENTAL SCIENCES↗

QA/QC-ed Groundwater Level Time Series in PLM-1 and PLM-6 Monitoring Wells, East River, Colorado (2016-2022)

This data set contains QA/QC-ed (Quality Assurance and Quality Control) water level data for the PLM1 and PLM6 wells. PLM1 and PLM6 are location identifiers used by the Watershed Function SFA project for two groundwater monitoring wells along an elevation gradient located along the lower montane life zone of a hillslope near the Pumphouse location at the East River Watershed, Colorado, USA. These wells are used to monitor subsurface water and carbon inventories and fluxes, and to determine the seasonally dependent flow of groundwater under the PLM hillslope. The downslope flow of groundwater in combination with data on groundwater chemistry (see related references) can be used to estimate rates of solute export from the hillslope to the floodplain and river. QA/QC analysis of measured groundwater levels in monitoring wells PLM-1 and PLM-6 included identification and flagging of duplicated values of timestamps, gap filling of missing timestamps and water levels, removal of abnormal/bad and outliers of measured water levels. The QA/QC analysis also tested the application of different QA/QC methods and the development of regular (5-minute, 1-hour, and 1-day) time series datasets, which can serve as a benchmark for testing other QA/QC techniques, and will be applicable for ecohydrological modeling. The package includes a Readme file, one R code file used to perform QA/QC, a series of 8 data csv files (six QA/QC-ed regular time series datasets of varying intervals (5-min, 1-hr, 1-day) and two files with QA/QC flagging of original data), and three files for the reporting format adoption of this dataset (InstallationMethods, file level metadata (flmd), and data dictionary (dd) files).QA/QC-ed data herein were derived from the original/raw data publication available at Williams et al., 2020 (DOI: 10.15485/1818367). For more information about running R code file (10.15485_1866836_QAQC_PLM1_PLM6.R) to reproduce QA/QC output files, see README (QAQC_PLM_readme.docx). This dataset replaces the previously published raw data time series, and is the final groundwater data product for the PLM wells in the East River. Complete metadata information on the PLM1 and PLM6 wells are available in a related dataset on ESS-DIVE: Varadharajan C, et al (2022). https://doi.org/10.15485/1660962. These data products are part of the Watershed Function Scientific Focus Area collection effort to further scientific understanding of biogeochemical dynamics from genome to watershed scales. 2022/09/09 Update: Converted data files using ESS-DIVE’s Hydrological Monitoring Reporting Format. With the adoption of this reporting format, the addition of three new files (v1_20220909_flmd.csv, V1_20220909_dd.csv, and InstallationMethods.csv) were added. The file-level metadata file (v1_20220909_flmd.csv) contains information specific to the files contained within the dataset. The data dictionary file (v1_20220909_dd.csv) contains definitions of column headers and other terms across the dataset. The installation methods file (InstallationMethods.csv) contains a description of methods associated with installation and deployment at PLM1 and PLM6 wells. Additionally, eight data files were re-formatted to follow the reporting format guidance (er_plm1_waterlevel_2016-2020.csv, er_plm1_waterlevel_1-hour_2016-2020.csv, er_plm1_waterlevel_daily_2016-2020.csv, QA_PLM1_Flagging.csv, er_plm6_waterlevel_2016-2020.csv, er_plm6_waterlevel_1-hour_2016-2020.csv, er_plm6_waterlevel_daily_2016-2020.csv, QA_PLM6_Flagging.csv). The major changes to the data files include the addition of header_rows above the data containing metadata about the particular well, units, and sensor description. 2023/01/18 Update: Dataset updated to include additional QA/QC-ed water level data up until 2022-10-12 for ER-PLM1 and 2022-10-13 for ER-PLM6. Reporting format specific files (v2_20230118_flmd.csv, v2_20230118_dd.csv, v2_20230118_InstallationMethods.csv) were updated to reflect the additional data. R code file (QAQC_PLM1_PLM6.R) was added to replace the previously uploaded HTML files to enable execution of the associated code. R code file (QAQC_PLM1_PLM6.R) and ReadMe file (QAQC_PLM_readme.docx) were revised to clarify where original data was retrieved from and to remove local file paths.

54 ENVIRONMENTAL SCIENCES↗

Data from: "Towards CONUS-Wide ML-Augmented Conceptually-Interpretable Modeling of Catchment-Scale Precipitation-Storage-Runoff Dynamics"

This data package was generated to support the manuscript “Towards CONUS-Wide Machine Learning-Augmented Conceptually Interpretable Modeling of Catchment-Scale Precipitation-Storage-Runoff Dynamics.” It provides input files, model outputs, plotting data, scripts, notebooks, and documentation used to develop, evaluate, and reproduce Mass-Conserving Perceptron (MCP)-based hydrologic modeling experiments across 513 selected Catchment Attributes and Meteorology for Large-sample Studies in the United States (CAMELS-US) basins. The files are organized by modeling component and analysis purpose, including rainfall–runoff experiments, snow module experiments, coupled hydrologic-snow experiments, Long Short-Term Memory (LSTM) benchmark results, model skill metrics, initialization and epoch records, cell-state normalization files, Akaike Information Criterion (AIC)-based model comparison files, and data used to generate manuscript figures. Tabular files can be opened using standard spreadsheet software or Python/R data-analysis tools. Python scripts, Jupyter notebooks, and selected MATLAB scripts are included for model execution, postprocessing, plotting, and statistical analysis. Quality assurance and quality control were conducted through the source-data selection and modeling workflow. Meteorological forcing, streamflow, and static catchment attributes were derived from the CAMELS-US dataset, and snow water equivalent data were derived from the University of Arizona (UA) Snow Water Equivalent dataset. Selected basins and time periods were screened during the associated research workflow to avoid missing observations or poor-quality cases. Static geospatial features were processed primarily using Quantum Geographic Information System (QGIS) and Geospatial Data Abstraction Library (GDAL) workflows. Additional details are provided in the associated manuscript and documentation.

ESS-DIVE CSV File Formatting Guidelines Reporting ↗

bifiPV2020 Bifacial Workshop: A Technology Overview

The virtual bifiPV Workshop was held in July 2020 to provide the solar industry with a forum for sharing and discussing research into bifacial photovoltaic (PV) technology. This report outlines major insights from the workshop to give the reader an overview of the latest developments in bifacial PV technology worldwide, from the lab to the field. Citations are drawn from this workshop unless otherwise noted, with all proceedings available online at bifipvworkshop. com. Presentations for the bifiPV2020 Workshop focused on the following areas: bifacial power plant modeling and simulation, albedo improvements, the development of encapsulants, the durability and reliability of current bifacial technologies, performance comparisons between glass-glass and glass-transparent backsheet configurations, the future of passivated emitter and rear contact (PERC) solar cells, and the growing adoption of n-type solar cells. With 650 GW total PV installed worldwide and 1 TW to come very soon, PERC is now the standard PV cell type produced en masse. However, it is already reaching 23% efficiency, the upper limit for this type of technology. PV modules breaking the 0.5-kW barrier are starting to appear, and the costs of standard PERC technology are already below 0.2 USD/Wp. In 2019, five GW of bifacial PV were installed worldwide. In 2020, the majority of bifacial installations are expected to be located in the United States, China, and Middle East and North Africa (MENA) states. N-type bifacial technologies are becoming increasingly viable and have huge potential to dominate the market in the coming years. With bifacial technology mounted on horizontal single-axis trackers (HSAT), bids below 10 USD/MWh will soon be observed in the MENA region, and later in Chile and the United States. Factory audits and reliability testing can reduce field failures by helping buyers to select producers that follow rigorous quality assurance and quality control processes.

14 SOLAR ENERGY↗

bifiPV2020 Bifacial Workshop: A Technology Overview

The virtual bifiPV Workshop was held in July 2020 to provide the solar industry with a forum for sharing and discussing research into bifacial photovoltaic (PV) technology. This report outlines major insights from the workshop to give the reader an overview of the latest developments in bifacial PV technology worldwide, from the lab to the field. Citations are drawn from this workshop unless otherwise noted. Presentations for the bifiPV2020 Workshop focused on the following areas: bifacial power plant modeling and simulation, albedo improvements, the development of encapsulants, the durability and reliability of current bifacial technologies, performance comparisons between glass-glass and glass-transparent backsheet configurations, the future of passivated emitter and rear contact (PERC) solar cells, and the growing adoption of n-type solar cells. With 650 GW total PV installed worldwide and 1 TW to come very soon, PERC is now the standard PV cell type produced en masse. However, it is already reaching 23% efficiency, the upper limit for this type of technology. PV modules breaking the 0.5-kW barrier are starting to appear, and the costs of standard PERC technology are already below 0.2 USD/Wp. In 2019, five GW of bifacial PV were installed worldwide. In 2020, the majority of bifacial installations are expected to be located in the United States, China, and Middle East and North Africa (MENA) states. N-type bifacial technologies are becoming increasingly viable and have huge potential to dominate the market in the coming years. With bifacial technology mounted on horizontal single-axis trackers (HSAT), bids below 10 USD/MWh will soon be observed in the MENA region, and later in Chile and the United States. Factory audits and reliability testing can reduce field failures by helping buyers to select producers that follow rigorous quality assurance and quality control processes.

14 SOLAR ENERGY↗

Calendar Year 2020 Underground Test Area Annual Sampling Report Nevada National Security Site, Nevada (Rev. 1)

This CY 2020 annual sampling report presents the background of the FFACO and Sampling Plan implementation, sampling and analysis methods, sampling results, quality assurance and quality control, regulatory requirements, and analytical data for the CY 2020. Appendix A presents data from samples collected in CY 2020 from the YF/CM CAU and the RM/SM CAU. This sampling was conducted in support of the Sampling Plan at these CAUs prior to approval of the final CRs. Appendix B presents the well completion diagrams for the wells sampled in CY 2020. Appendix C presents data from samples collected in CY 2019. These results were not reported in the previous sampling report because they were not available from the specialized laboratories at the time of the report’s publication.

54 ENVIRONMENTAL SCIENCES↗

Eco-Friendly High-Performance Carbon Building Material Development from Coal

The development of eco-friendly high-performance building materials based on coal-derived materials is greatly beneficial for promoting environmental sustainability and the coal industry. This project focused on advancing technology to create innovative and scalable construction materials from two domestic sources: (1) coal-derived pyrolyzed char (PC), and (2) solvent-extracted coal deposit, extracts, and residue (CDER). It aimed to simultaneously develop and produce two types of coal-derived building products: (1) char-based concrete bricks (CCB) for wall construction in buildings, and (2) carbon-based structural units (CSU) intended as alternatives to traditional wood, concrete, or steel framing structures. The project team has successfully developed methods for manufacturing CCB samples. Extensive experiments were conducted to assess various manufacturing techniques for these samples. This included measuring their physical properties such as thermal conductivity (ranging from 0.26 to 0.38 W/mK) and bulk density (ranging from 0.85 to 1.15 g/cm 3 ), along with their mechanical properties (e.g., compressive strength ranging from 14 to 16 MPa at 28 days) for samples with a PC composition of 70%. Quality assurance and quality control tests, focusing on density and compressive strength, were also performed on samples selected randomly from pilot-scale production, and cured for a long term (over three months). The average long-term compressive strength of two randomly selected CCB samples was measured as 15.1 MPa, which was higher than the required target strength of 14 MPa. This indicates that the manufactured CCB samples from the preliminary pilot scale production run have good quality control and long-term strength performance.

01 COAL, LIGNITE, AND PEAT↗

Nondestructive property and defect characterization using X-rays and neutrons

As advanced manufacturing (AM) continues to mature as a fabrication technique, interest in its use for the fabrication of nuclear components continues to grow. AM nuclear parts offer the ability to create parts with complex and non-standard geometries that cannot be produced using traditional manufacturing techniques, circumvention of supply chain issues, and reduction of time from design to implementation. However, components fabricated with AM techniques must undergo nondestructive examination (NDE) to ensure they are fabricated to the required specifications to ensure safe and proper operation. The Advanced Materials and Manufacturing Technologies (AMMT) program has undertaken initial exploratory studies on several NDE techniques to evaluate their feasibility for research and development (R&D), as well as Quality Assurance and Quality Control (QA/QC), and in-service inspections of AM parts. This work describes research results on several techniques, including X-ray and neutron tomography and scattering, as well as photothermal radiometry. The experimental results are described and an overview for each techniques’ potential use on AM parts in the various phases of part development and lifetime is given. Finally, future directions for technique development and application to AM nuclear components are described.

36 MATERIALS SCIENCE↗

Automated Segmentation of Twin Boundaries in TRISO Silicon Carbide Using Deep Neural Networks

Coated particle fuels, such as the tristructural isotropic (TRISO) fuel particle, are essential for high-temperature gas reactor (HTGR) applications due to their efficiency and stability under normal and off-normal conditions. However, widespread commercialization and deployment of this technology for next-generation nuclear applications require robust quality assurance and quality control (QA/QC) methods linking fabrication, properties, and performance. Of the many important metrics for TRISO QA/QC, quantification of the silicon carbide (SiC) microstructure is critical because it correlates with fission product retention during irradiation. Previous work has shown extensive twinning of the SiC microstructure, which strongly affects microstructural metrics; however, twin grain boundaries are not expected play a significant role in fission product diffusion. This report summarizes the initial development, training, and testing of a machine learning image processing algorithm to detect twin grain boundaries in a backscattered electron image, which can be removed so that microstructural metrics can be recalculated for legacy data. Further development and deployment of this model will provide automated, scalable improvement of potential QA/QC methods for the SiC layer of TRISO particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗