Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION, GAMMA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Reliability studies on Si PIN photodiodes under Co-60 gamma radiation

Silicon PIN photodiodes were fabricated with 250 nm SiO{sub 2} antireflective coating (ARC). The changes in the electrical characteristics, capacitance-voltage characteristics and spectral response after gamma irradiation are systematically studied to estimate the radiation tolerance up to 10 Mrad. The different characteristics studied in this investigation demonstrate that Si PIN photodiodes are suitable for high radiation environment.

36 MATERIALS SCIENCE↗

Characterization of commercial proton exchange membrane materials after exposure to beta and gamma radiation

Proton Exchange Membrane (PEM) type electrolysis cells have a potential use for tritium removal and heavy water upgrading. AECL is currently exposing various commercial PEM materials to both gamma (Cobalt-60 source) and beta (tritiated water) radiation to study the effects of radiation on these materials. This paper summarizes the testing methods and results that have been collected to date. The PEM materials that are or have been exposed to radiation are: Nafion 112, 212, 117 and 1110. Membrane characterization pre- and post- exposure consists of non-destructive inspection (FTIR, SEM/XPS), mechanical (tensile strength, percentage elongation, and modulus), electrical (resistance), or chemical (ion-exchange capacity - IEC). It has appeared that the best characterization techniques to compare exposed versus unexposed membranes were IEC, ultimate tensile strength and percent elongation. These testing techniques are easy and cheap to perform. The non-destructive tests, such as SEM and FTIR did not provide particularly useful information on radiation-induced degradation. Where changes in material properties were measured after radiation exposure, they would be expected to result in poorer cell performance. However, for modest γ-radiation exposure, all membranes showed a slight decrease in cell voltage (better performance). In contrast, the one β-radiation exposed membrane did show the expected increase in cell voltage. The counterintuitive trend for γ-radiation exposed membranes is not yet understood. Based on these preliminary results, it appears that γ- and β-radiation exposures have different effects.

07 ISOTOPE AND RADIATION SOURCES↗

Development of a Physical-Topological Model for the Response of a High-Power Vertical DMOS Transistor to the Effect of Pulsed Gamma-Radiation

A method for developing models of semiconductor devices with two-dimensional nonuniform concentration profiles of donors and acceptors in working regions of a semiconductor device structure is for the first time proposed based on a complex of physical-topological modeling of charge carrier transport and process simulation of the forming processes of the device structure. The application of process simulation is due to the need to correctly define the parameters of the semiconductor device structure, which are used as initial data to calculate the electron transport according to the physical-topological model. The parameters of production processes of ion implantation, diffusion, and lithography, which were refined during process simulation, are determined for a high-power metal—oxide—semiconductor (MOS) transistor forming by the double diffusion method in accordance with known electrical characteristics and measured geometrical sizes of the structure. This results in two-dimensional distribution profiles of donors and acceptors in p–n junctions necessary to calculate the transistor breakdown under the effect of pulsed γ radiation. Breakdown processes are modeled with the help of the physical-topological model based on the Poisson and continuity equations as well as expressions for the diffusion and drift current densities in the transistor. Accounting for carriers formed at the instant of γ irradiation is implemented by the introduction of the dependence of the generation coefficient of electron–hole pairs on the radiation-dose power. The results of calculations correlate well with the experimental data, which makes it possible to give a conclusion regarding the adequacy of the proposed complex model.

36 MATERIALS SCIENCE↗

Low Dose Gamma Radiation Monitoring Through TiO{sub 2} Doped Lead Phthalocyanine (Pb-Pc) Based Schottky Device

The concept of Organic thin film based solid-state dosimeters is relatively new and more effective. The organic conductor based solid-state dosimeter provides a mean for low cost, ease to fabricate and sensitive radiation sensor which can be employed as pocket dosimeter for army personals getting exposed to nuclear radiation while working in the radioactive environment This concept is being utilized here for monitoring the effect of nuclear radiation on our organic material based sandwiched devices. In the present communication, lead Phthalocyanine (PbPc) doped with TiO{sub 2} (5% by weight) is developed into the form of thin film structure. The developed ITO/PbPc: TiO{sub 2}/Ag Schottky device structure was characterized in terms of change in its electrical and optical properties before and after exposure to radiation Exposure to radiation imparts an accelerated decrease in forward bias current and capacitance characteristics reveal a linear relationship between dose v/s current behavior which supports its suitability as pocket dosimeter for the dose ranging from 50 mR to 800 mR.

36 MATERIALS SCIENCE↗

Effect of Gamma Radiation on the Properties of Crosslinked Chitosan Nano-composite Film

Chitosan nano-composite film crosslinked by citric acid and with glycerol as plasticizer and MgO as antibacterial agent was prepared by casting method. MgO nanoparticles were synthesized via calcination method in furnace at 500 °C for 4 h and characterized by X-ray diffraction and transmission electron microscope. The chitosan nano-composite film with composition chitosan/citric/glycerol/magnesium oxide (1 wt%:1 wt%:75 vol%:10 wt%) has high mechanical properties than other films. The effects of different irradiation doses on the mechanical, thermal and antibacterial activity were investigated. The tensile strength enhanced by increasing irradiation dose up to 10 kGy and the elongation negligible changed as irradiation dose increased. The thermal stability slightly increased up to dose 2.5 kGy then decreased with dose increment. The antimicrobial activity film was studied against white mulberry-borne bacterial pathogens either Gram positive or Gram negative bacteria and has positive impact of gamma irradiation on the antimicrobial activity. The use of the selected chitosan nano-composite film which irradiated by dose of 2.5 kGy and has magnesium oxide of average particle size 54.3 nm as new packaging materials found to improve storage quality and shelf-life of mulberry fruit.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of Gamma Radiation on Absorption of Light in Potassium-Aluminoborate Glasses with Additions of Iron Oxide

The effect of radiation on the absorption of light by potassium–alumina–borate glasses with various concentrations of iron additions and various thicknesses was investigated. It was shown that in contrast to samples of small thickness (1 mm) a bleaching effect was observed in the samples with a thickness of 8 mm. A possible mechanism involving the formation of nanostructured units is proposed for the observed effect.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Determination of activity of {sup 51}Cr on gamma radiation measurements

A method of determining the activity of intensive distributed -sources on the measurement of the continuous spectrum of radiation, for example the internal bremsstrahlung, is developed. The recurrent formula for reconstructing of a continuous spectrum, registered in a Ge detector, at distorting it in the detector. The method of precise measurements of the spectrum of {sup 51}Cr internal bremsstrahlung using two point sources of low activity is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma radiation from radio pulsars

The probable magnetospheric location and source of the gamma ray emission from some young radiopulsars is discussed. The suggested evolution of this emission as a function of pulsar period gives a diminished gamma-ray luminosity for a more rapidly spinning pre-Crab pulsar. A greatly enhanced one, similar to that of unidentified Cos B sources, is predicted for a slightly slower post-Vela pulsar, followed by a relatively rapid quenching of the gamma-ray luminosity at still longer periods. Possible anomalous exo-magnetospheric pulsed MeV and TeV-PeV radiation from the Crab pulsar is considered.

Ruderman, Malvin↗

Criticality detection method based on FP gamma radiation measurement

A method is proposed to evaluate the extent of subcriticality of an accident-damaged nuclear reactor. In this method the radiation ratio of two FP rare gas nuclides, {sup 88}Kr and {sup 133}Xe, is measured. From the measured value, the value in the core is estimated by correcting for the time required by the gases to diffuse from the core to the measuring point. A simple expression for neutron multiplication factor has been derived, which uses the corrected {sup 88}Kr-to-{sup 133}Xe radiation ratio and the {sup 88}Kr-to-{sup 133}Xe fission yield ratios from {sup 244}Cm and {sup 235}U but no information on the amount or distribution of fissile materials, making the proposed method very simple. The method has the advantage that FP rare gases can easily leak from the reactor core through many openings and gaps, reaching germanium counters without reacting with other materials. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

KGK-2-type detector of gamma-radiation power for diagnosis of nuclear reactor radiation fields within the range from 1 µGy/s to 100 Gy/s

The construction of the KGK-2-type detector of γ-radiation power is briefly described. The diagnostic possibilities of the detector are shown by the example of results of the dose rate measurement in the energy start-ups of the BR-K1 and BR-1M reactors implemented in the mode of generating fission pulses on delayed neutrons. The possibilities of using the KGK-2 detector for postpulse γ diagnostics are demonstrated by the example of results of measurements in the fission pulse on prompt neutrons of the BR-1M reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Use of information on the motion of spacecraft around the center of bodies in the undertaking of detecting sources of X-ray and gamma radiation

The problem of localizing sources of X-ray and gamma surges can be solved vis the installation of suitable monitors on several dispersed spacecraft. In this manner, determination of the coordinates of the source is possible only with the use of four spacecraft. In the case of the use of 3 or 2 spacecraft, it is necessary to use supplementary information. Data on the motion of a spacecraft around the center of a mass was used in the capacity of such information.

Eysmont, N. A.↗

Effect of Bcl11b genotypes and {gamma}-radiation on the development of mouse thymic lymphomas

Bcl11b is a haploinsufficient tumor suppressor gene and expressed in many tissues such as thymus, brain and skin. Irradiated Bcl11b{sup +/-} heterozygous mice mostly develop thymic lymphomas, but the preference of Bcl11b inactivation for thymic lymphomas remains to be addressed. We produced Bcl11b{sup +/-} heterozygous and Bcl11b wild-type mice of p53{sup +/-} background and compared their incidence of {gamma}-ray induced thymic lymphomas. Majority of the tumors in p53{sup +/-} mice were skin tumors, and only 5 (36%) of the 14 tumors were thymic lymphomas. In contrast, Bcl11b{sup +/-}p53{sup +/-} doubly heterozygous mice developed thymic lymphomas at the frequency of 27 (79%) of the 34 tumors developed (P = 0.008). This indicates the preference of Bcl11b impairment for thymic lymphoma development. We also analyzed loss of the wild-type alleles in the 27 lymphomas, a predicted consequence given by {gamma}-irradiation. However, the loss frequency was low, only six (22%) for Bcl11b and five (19%) for p53. The frequencies did not differ from those of spontaneously developed thymic lymphomas in the doubly heterozygous mice, though the latency of lymphoma development markedly differed between them. This suggests that the main contribution of irradiation at least in those mice is not for the tumor initiation by inducing allelic losses but probably for the promotion of thymic lymphoma development.

60 APPLIED LIFE SCIENCES↗

SAS 2 observation of pulsed high-energy gamma radiation from Geminga

Following the detection of pulsed X-rays and gamma rays from Geminga, the 1972-1973 SAS 2 data which first revealed this source have been reanalyzed. The 237 ms periodicity is visible in those observations. The phase of the SAS 2 periodicity is consistent with that of COS B suggesting that the gamma-ray data allow an accounting for every revolution of the Geminga pulsar between 1972 and 1982.

Mattox, J. R.↗