Search NASA⌕ Search

SEARCH · Search NASA

Results for “RECORDING INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Approaching Angstrom-Scale Resolution in Lithography Using Low-Molecular-Mass Resists (<500 Da)

Resists that enable high-throughput and high-resolution patterning are essential in driving the semiconductor technology forward. The ultimate patterning performance of a resist in lithography is limited because of the trade-off between resolution, line-width roughness, and sensitivity; improving one or two of these parameters typically leads to a loss in the third. As the patterned feature sizes approach angstrom scale, the trade-off between these three metrics becomes increasingly hard to resolve and calls for a fundamental rethinking of the resist chemistry. Low-molecular-mass monodispersed metal-containing resists of high atom economy can provide not only very high resolution but also very low line-width roughness without sacrificing sensitivity. Here we describe a modular metal-containing resist platform (molecular mass <500 Da) where a molecular resist consists of just two components: a metal and a radical initiator bonded to it. This simple system not only is amenable to high-resolution electron beam lithography (EBL) and extreme ultraviolet lithography (EUVL) but also unites them mechanistically, giving a consolidated perspective of molecular and chemical processes happening during exposure. Irradiation of the resist leads to the production of secondary electrons that generate radicals in the initiator bonded to metal. This brings about an intramolecular rearrangement and causes solubility switch in the exposed resist. We demonstrate record 1.9–2.0 nm isolated patterns and 7 nm half-pitch dense line-space features over a large area using EBL. With EUVL, 12 nm half-pitch line-space features are shown at a dose of 68 mJ/cm 2 . In both of these patterning techniques, the line-width roughness was found to be ≤2 nm, a record low value for any resist platform, also leading to a low-performance trade-off metric, Z factor, of 0.6 × 10 –8 mJ·nm 3 . With the ultimate resolution limited by instrumental factors, potential patterning at the level of a unit cell can be envisaged, making low-molecular-mass resists best poised for angstrom-scale lithography.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Holographic wavefront sensors

A brief historical review of the first designs of holographic wavefront sensors (WFS’s) and the concepts lying in their basis is presented. The main directions in the development of these sensors are highlighted and considered. One of these directions implies a two-stage transition from the use of several separate measuring channels with holograms filtering only one Zernike mode: first to the use of one channel with a multiplexed hologram filtering several first Zernike modes, and then to filtering the entire set of Zernike modes with the aid of one combined multiplexed hologram. Another line of research in this field (related to the first one) is the optimisation of the filter hologram structure in order to reduce cross-modulation interferences, increase multiplexing level, etc. One more line of research implements principles of dynamic holography by introducing spatial light modulators into the WFS composition. Hence, the advantages of time multiplexing of holograms can be used. The approach developed by G. Andersen’s team, aimed at adapting the holographic WFS design for operation as an element of adaptive optical system with a zonal corrector, as well as an approach implying development of hybrid holographic sensors, are considered separately. The results of the authors’ studies of holographic WFS’s with application of the methods of Fourier holography (i.e., holography of focused beams, in particular, using diffuse scatterers in a hologram recording channel) are also reported. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of liquid petroleum using a laser-induced breakdown spectroscopy instrument

Here, a prototype analyzer for the direct LIBS analysis of nebulized liquid samples was developed and tested, particularly for the analysis of petroleum, organic solvents and aqueous solutions. The LIBS analyzer requires about 750 µl of liquid sample, 1 liter of N 2 gas, and 10 s of the analysis time to record 100 spectra. The limits of detection in oil and solvent are as low as 0.01–0.04 ppm for Li, Mg, and Cu. They increase for the difficult elements, such as Pb and Hg (7-10 ppm), Cl (250 ppm), and S (~0.7%). The relative standard deviation of measuring 100 ppm vanadium in oil and solvent was 1.5%. The LIBS detection limits and repeatability are better than required by the standard method ASTM D5185 for the analysis of lubricating oils in ICP-OES. Several petroleum samples were analyzed by LIBS and the quantitative results for V, Ni, and Fe compared to the ICP-OES data. Light crude oils can be nebulized and analyzed directly. Medium crude oils require minimal dilution at least 1:1, otherwise errors of determination become large. Presumably, utilization of the internal standard and chemometrics can be useful to correct for the matrix effects. In addition to the trace element analysis, the LIBS prototype demonstrated ability to measure the hydrogen-to-carbon ratio in organic liquid samples. Several unidentified features were observed in the carbon spectrum. Their possible origin is discussed.

02 PETROLEUM↗

Nondestructive measurements of residual 235 U mass of Israeli Research Reactor-1 fuel using the Advanced Experimental Fuel Counter

In 2018, a measurement campaign took place with participants from Los Alamos National Laboratory (LANL), the Nuclear Research Centre-Negev (NRCN) and Soreq Nuclear Research Center (SNRC) at the Israeli Research Reactor-1 (IRR-1) in which 14 of the reactor’s used fuel assemblies (FAs) with varied amount of depletion were measured with the nondestructive assay instrument Advanced Experimental Fuel Counter (AEFC). Designed for safeguards purposes, the AEFC measures both neutrons emitted from the FA (passive neutrons) and fission neutrons induced by an external neutron source (in this experiment, 252 Cf). Signals recorded with the AEFC include total neutron count rates (Singles), time-correlated neutron count rates (Doubles), and total gamma-ray count rates. The 235 U content of the FAs was previously assessed by two independent methods: (1) measurement of the transparency of the FA to low-energy gamma rays from an activated rhenium source (rhenium gamma transmission, or the RGT method) and (2) calculation of the 30-year burnup history of the core using detailed three-dimensional Monte-Carlo core depletion calculations. The results from the FAs that had been measured via the RGT method were used to construct the calibration curves, which translate the AEFC count rates to 235 U mass. Then, the calibration was evaluated using AEFC measurements of six additional FAs that were not measured via the RGT method. From the results, it was determined the Doubles calibration curve was more reliable than that of the Singles and follows a simple second-order polynomial fit for the whole range of residual 235 U mass content, albeit with larger statistical uncertainty. Detailed uncertainties quantification was conducted for both the AEFC Singles and Doubles. This includes the analysis of statistical uncertainties, calibration uncertainty, and random uncertainties due to the sensitivity of the AEFC to several sources of uncertainty, namely the FA position, FA orientation, interrogation source position, and ambient pool temperature. Finally, an overall total uncertainty of 6 g of 235 U is estimated for the Singles and Doubles, which is mainly due to calibration uncertainty (for the Singles) and statistical uncertainty (for the Doubles), and which constitutes 3%–6% of the 235 U total mass in the FAs, depending on their level of depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Explainable AI (XAI)-driven vibration sensing scheme for surface quality monitoring in a smart surface grinding process

Local Interpretable and Model-agnostic Explanation (LIME), an explainable artificial intelligence (XAI) approach is adapted to identify the globally important time-frequency bands for predicting average surface roughness (Ra) in a smart grinding process. The smart grinding setup consisted of a Supertech CNC precision surface grinding machine, instrumented with a Dytran piezoelectric accelerometer attached to the tailstock quill along the tangential direction (Y-axis). For every grinding pass, vibration signatures were captured, and the ground truth surface roughness values were recorded using a Mahr Marsurf M300C portable surface roughness profilometer. The roughness values ranged from 0.06 to 0.14 microns over the complete set of experiments. Time-frequency domain spectrogram frames were extracted for each of the vibration signals collected during the grinding process. Convolutional Neural Networks (CNNs) were modeled to predict the surface roughness based on these spectrogram frames and their image augmentations. The best CNN model was able to predict the roughness values with an overall R2-score of 0.95, training R2-score of 0.99, and testing R2-score of 0.81 with only 80 sets of vibration signals corresponding to 4 experiments with 20 trials each. Although the data size is not large enough to guarantee such performance metrics in real-world scenarios, one can extract statistically consistent explanations underlying the relationships these complex deep learning models capture. Further, the LIME methodology was implemented on the developed surface roughness CNN model to identify the important time-frequency bands (i.e., the superpixels of a spectrogram) influencing the predictions. Based on the identified important regions on the spectrogram frames, the corresponding frequency characteristics were determined that influence the surface roughness predictions. The important frequency range based on LIME results was approximately 11.7 to 19.1 kHz. The power of XAI was demonstrated by cutting down the sampling rate from 160 kHz to 30, 20, 10, and 5 kHz based on the important frequency range and considering Nyquist criteria. Separate CNN models were developed for these ranges by only extracting time-frequency contents below their corresponding Nyquist cut-offs. A proper data acquisition strategy is proposed by comparing the model performances to argue the selection of a sufficient sampling rate to capture the grinding process successfully and robustly.

42 ENGINEERING↗

Solar Radiation Research Laboratory (SRRL) Final Report: Fiscal Years 2019-2021

The Solar Radiation Research Laboratory (SRRL) at the National Renewable Energy Laboratory (NREL) is a world-leading solar calibration and measurement facility and maintains and disseminates the World Radiation Reference (essentially the W/m 2 ) for the United States, which is essential for traceable and accurate measurements of solar radiation at all solar generation facilities. SRRL operates two International Organization for Standardization (ISO)/International Electrotechincal Commission (IEC) 17025 calibration facilities that provide unique, high-quality calibrations to NREL and other U.S. Department of Energy laboratories. The Baseline Measurement System at SRRL provides a high-quality record of solar irradiance and surface meteorological conditions. SRRL capabilities are used to develop: improved methods for the calibration of solar radiometers; new standards through the ISO, the IEC, and ASTM International; models; advanced instrumentation and methods for operating solar measurement stations. The SRRL data sets are also critical for the validation of new models and data sets, such as the National Solar Radiation Database (NSRDB).

14 SOLAR ENERGY↗

Multispectral and Thermal Imager Onboard Aerial Platforms Instrument Handbook

The MicaSense Altum imager is an off-the-shelf, synchronized multispectral and thermal camera, combined with a Global Positioning System (GPS) unit and downwelling light sensor (DLS). The Altum takes images of the land surface within its field of view (FOV) across five visible bands and one longwave infrared thermal band. The sensor records the radiance and converts it to digital numbers. Imagery is radiometrically corrected, taking into account the sensor calibration, lens distortions, vignette effects, sun angle, and atmospheric effects (scattering and absorption). The photogrammetry software Agisoft PhotoScan v 1.4 is used to align and stitch the images into a larger composite image using the technique of structure from motion image capture to construct a dense cloud and 3D model of the surface, which is used to produce a digital elevation model of the terrain surveyed and orthomosaic imagery. Land surface leaf area index, albedo, and surface skin temperature are provided for the user. The user can perform raster calculations on the imagery to produce various other vegetative indices, which are used to indicate plant health and land surface characteristics, including Normalized Difference Vegetation Index (NDVI), Green Normalized Difference Vegetation Index (GNDVI), Normalized Difference Water Index (NDWI), surface temperature, and Enhanced_vegetation_index (EVI). This code is provided with the readme file for each data set. The images have a resolution of 20-60 cm/pixel, which are subsampled to 100 cm/pixel.

47 OTHER INSTRUMENTATION↗

AE33 Aethalometer Records at RMBL [AMF2] from April 2022 to October 2023

The dataset presents atmospheric mass loadings of black carbon (BC) and brown carbon (BrC), during the Surface Atmosphere Integrated Field Laboratory (SAIL) campaign that took place from 2021 – 2023 in Gothic, CO. A Magee Scientific aethalometer (model AE33) was deployed at the Rocky Mountain Biological Laboratory, 200 m north of AMF2 to monitor mass loadings of optically absorbing aerosols. The instrument inlet was equipped with a BGI SCC 1.829 ambient cyclone with a particle cutoff of 2.5 μm and placed 5 m above ground level. The dataset reports hour-resolved BC mass loadings at 370, 470, 520, 590, 660, 880, and 950 (BC370, BC470, BC 520, BC590, BC660, BC880, BC950 in ng/m3) reported by the instrument built-in algorithm, which calculates mass loadings from the rate of change of the attenuation of light transmitted through the aerosol-laden filter. BC880 is the operationally defined reference of the BC concentration. Hour-resolved absorbance at each wavelength were calculated from their respective mass absorption cross-section in inverse megameters (Mm-1). The absorption Angstrom exponent (AAE) for BrC and BC were calculated for each hour. BrC AAE (AAE_BrC) was calculated from the slope of Log(wavelength) versus Log(absorbance) based on the measurements at 370, 470, and 520 nm. BC AAE (AAE_BrC) was calculated from the slope of Log(wavelength) versus Log(absorbance) based on the measurements at 590, 660, 880, and 950 nm. The aethalometer record spans time periods of 4/5/2022 – 10/3/2022 and 12/8/2022 – 10/9/2023. The ambient CO2 concentration recorded by a Vaisala CARBOCAP carbon dioxide probe GMP343 is also reported in ppm.

54 ENVIRONMENTAL SCIENCES↗

Measurement of Thomson-scattering spectra with continuous angular resolution (invited)

Here, a novel Thomson-scattering diagnostic with continuous angular resolution over a span of 120° was developed for the characterization of plasmas produced at the Omega Laser Facility. Spectrally resolving light scattered from electron plasma wave features as a function of emission angle provides a means to efficiently probe a large range of plasma frequencies and k vectors. Together, these spectra contain critical constraints on the plasma-physics models used to interpret the data and enable experimental measurements of the electron-velocity distribution function over several orders of magnitude without assumptions about its mathematical form. Major components of the instrument include (1) a reflective collection objective that gathers light over a range of 120° × 12°; (2) a spatial-filter image relay for measurement localization; (3) cylindrical optics for producing a line image of the collection aperture; (4) a transmission grating spectrometer; and (5) a time-gated, image-intensified camera. Thomson-scattered light collected from an ~(50 – μM) 3 volume of plasma is recorded with 0.8-nm spectral and 1° angular resolution. Initial experiments examined the properties of the electron-velocity distribution in gas-jet-produced plasmas in the presence of heating via inverse bremsstrahlung absorption.

47 OTHER INSTRUMENTATION↗

Performance testing of the iX Cameras iSpeed 727 high-speed camera

This work evaluated the iX Cameras iSpeed 727, a commercial CMOS-based continuous- recording high-speed camera. Various parameters of importance in the scheme of accurate time-resolved measurements and photonic quantification have been measured under controlled conditions on the bench, using state-of-the-art instrumentation. We will detail the procedures and results of the tests laid out to measure sensor sensitivity, linearity, signal-to-noise ratio and image lag. We also looked into the electronic shutter performance and accuracy, as exposure time is of particular interest to high-speed imaging. The results of the tests show that this camera matches or exceeds the performance of competing units in most aspects, but that, as is the case for other high-speed camera systems, corrections are necessary to make full use of the image data from a quantitative perspective.

42 ENGINEERING↗

Booster Neutrino Beam operations and neutrino flux prediction

The Booster Neutrino Beam (BNB) Line is used to produce neutrino beams for the 8 GeV Neutrino Program at Fermilab. This talk will provide a summary of the BNB operations and an estimate of the neutrino flux that is produced by the beamline. The talk will also summarize the work to upgrade the system which records the longitudinal structure of the primary proton beam that is delivered to BNB production target.

43 PARTICLE ACCELERATORS↗

Windsonde Atmospheric Profile during CoURAGE 2024-2025 at Kent Island.

This is the atmospheric sounding data using Sparv Windsond S1 lower-atmosphere profiling instruments ( https://sparv.io/products/windsond-s1) . These data are taken weekly (twice weekly and twice daily during the two CoURAGE IOPs in February and July 2025). Lower-atmosphere conditions, generally between the surface and 5km altitude, are recorded. The variables include pressure, height, temperature, dew-point temperature, wind speed, and wind direction.

air_temperature↗

Windsonde Atmospheric Profile during CoURAGE 2024-2025 at Baltimore.

This is the atmospheric sounding data using Sparv Windsond S1 lower-atmosphere profiling instruments ( https://sparv.io/products/windsond-s1) . These data are taken weekly (twice weekly and twice daily during the two CoURAGE IOPs in February and July 2025). Lower-atmosphere conditions, generally between the surface and 5km altitude, are recorded. The variables include pressure, height, temperature, dew-point temperature, wind speed, and wind direction.

air_temperature↗

Background Measurements and Simulations of the ComPair Balloon Flight

ComPair, a prototype of the All-sky Medium Energy Gamma-ray Observatory (AMEGO), completed a short-duration high-altitude balloon campaign on 27 August 2023 from Fort Sumner, New Mexico, USA. The goal of the balloon flight was to demonstrate ComPair as both a Compton and Pair telescope in flight, reject the charged particle background, and measure the background γ-ray spectrum. This analysis compares measurements from the balloon flight with Monte Carlo simulations to benchmark the instrument. The comparison finds good agreement between the measurements and simulations and supports the conclusion that ComPair accomplished its goals for the balloon campaign. Additionally, two charged particle background rejection schemes are discussed: a soft ACD veto that records a higher charged particle event rate but with less risk of event loss, and a hard ACD veto that limits the charged particle event rate on board. There was little difference in the measured spectra from the soft and hard ACD veto schemes, indicating that the hard ACD veto could be used for future flights. The successes of ComPair’s engineering flight will inform the development of the next generation of ComPair with upgraded detector technology and larger active area.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-spatio-temporal scales PIV in a turbulent buoyant jet discharging in a linearly stratified environment

Time-resolved particle image velocimetry is implemented with a camera array and several laser sheets; this results in a multi-spatio-temporal scale system that is modular and flexible. The setup is optimized to capture global flow features, while locally resolving in space and time near the Kolmogorov scale. The apparatus relies extensively on machine vision CMOS cameras; they are inexpensive and stream to computer hard drive with virtually continuous time-resolved records (up to one hour for the current system). This leads to statistically converged data and also helps in minimizing down time between experimental runs. Details of the implementation and design of experiment are reported. The system instruments a vertical buoyant jet discharging in a linearly stratified environment. Refractive index matched aqueous solutions enable precise optical deployment. The density difference is 3% and the fluids have similar dynamic viscosity. The jet Reynolds number is 2.00 x 10 4 and is above the mixing transition. Such flows are typically challenging to instrument and few velocity field data are available to date. The velocity statistics are reported as well as first insights gained from the campaign.

42 ENGINEERING↗

Intermolecular correlations of liquid and glassy CS 2 studied by synchrotron radiation x-ray diffraction

How is the orientation of molecular liquids ordered on cooling? What are the basic structures of molecular glasses, e.g., close to the crystalline structure or some special structures such as icosahedral cluster? These are long-standing questions in liquid and glass physics. Here, we have constructed a novel cryostat to prepare simple molecular glasses by vapor deposition and performed in situ synchrotron radiation x-ray diffraction experiments. The glassy state of a simple molecule CS 2 , which cannot be vitrified by normal liquid quenching, was successfully prepared with this instrument, and its diffraction data were collected in a wide Q-range of 0.16–25.7 Å -1 with a high-energy diffractometer at BL04B2, SPring-8. The diffraction data of liquid CS 2 were also recorded in a wide temperature range of 160–300 K. These diffraction data were analyzed with molecular dynamics simulations and reverse Monte Carlo modelings to investigate orientational correlation. From the obtained 3D structure models, the orientational correlation between neighboring CS 2 molecules was investigated quantitatively as a function of temperature. At room temperature, the parallel and T-shaped arrangements are preferred for the nearest neighbor correlation. On cooling, these arrangements are developed gradually, and its rate became prominent below the melting temperature (162 K). In the glassy state, the slipped-parallel arrangement is dominant as well as the T-shaped arrangement. Both arrangements appear in the CS 2 crystal, indicating that the structure of glassy CS 2 is close to that of crystalline CS 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study and improvement of the trigger system in ICARUS

In recent years, intriguing experimental neutrino anomalies have emerged. If confirmed, they could hint at the presence of additional sterile neutrino states playing in neutrino mixing. The Short-Baseline Neutrino project at Fermilab aims to delve into these anomalies, utilizing three Liquid Argon Time Projection Chamber detectors along the Booster Neutrino Beam. The SBND detector serves as nearby instruments, while MicroBooNE and ICARUS function as far detectors and also explore the NuMI beam off-axis. A relevant aspect in the functioning of all SBN detectors is the trigger system, that determines which interactions are recorded. In particular, in ICARUS, it relies on the synchronization of prompt signals from scintillation light within the LAr-TPC, detected by a system of Photo-Multiplier Tubes, with the proton beam’s spill extraction. The existing majority-based logic of the trigger system could potentially be enhanced through adder boards that sum analog signals from PMTs in groups of 15. This sum-based triggering might aid in identifying events near TPC walls, where light is abundant but captured by only a few PMTs, potentially bypassing the majority condition. Comprehensive tests have been performed to characterize these adder boards.

43 PARTICLE ACCELERATORS↗

Doping engineering: Next step toward room temperature performance of terahertz quantum cascade lasers

We hereby offer a comprehensive analysis of various factors that could potentially enable terahertz quantum cascade lasers (THz QCLs) to achieve room temperature performance. We thoroughly examine and integrate the latest findings from recent studies in the field. Our work goes beyond a mere analysis; it represents a nuanced and comprehensive exploration of the intricate factors influencing the performance of THz QCLs. Through a comprehensive and holistic approach, we propose novel insights that significantly contribute to advancing strategies for improving the temperature performance of THz QCLs. This all-encompassing perspective allows us not only to present a synthesis of existing knowledge but also to offer a fresh and nuanced strategy to improve the temperature performance of THz QCLs. We draw new conclusions from prior works, demonstrating that the key to enhancing THz QCL temperature performance involves not only optimizing interface quality but also strategically managing doping density, its spatial distribution, and profile. This is based on our results from different structures, such as two experimentally demonstrated devices: the spit-well resonant-phonon and the two-well injector direct-phonon schemes for THz QCLs, which allow efficient isolation of the laser levels from excited and continuum states. In these schemes, the doping profile has a setback that lessens the overlap of the doped region with the active laser states. Our work stands as a valuable resource for researchers seeking to gain a deeper understanding of the evolving landscape of THz technology. Furthermore, we present a novel strategy for future endeavors, providing an enhanced framework for continued exploration in this dynamic field. This strategy should pave the way to potentially reach higher temperatures than the latest records reached for T max of THz QCLs.

47 OTHER INSTRUMENTATION↗