Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A Method for Characterizing PMR-15 Resin

Quantitative analysis technique based on reverse-phase, highperformance liquid chromatography (HPLC) and paired-ion chromatography (PIC) developed for PMR-15 resins. In reverse-phase HPLC experiment, polar solvent containing material to be analyzed passed through column packed with nonpolar substrate. Composition of PMR-15 Resin of 50 weight percent changes as resin ages at room temperature. Verification of proper resin formulation and analysis of changes in resin composition during storage important to manufacturers of PMR-15 polymer matrix composite parts. Technique especially suitable for commercial use by manufacturers of high-performance composite components.

Roberts, G. D.↗

Characterization of Polyimide Matrix Resins and Prepregs

Graphite/polyimide composite materials are attractive candidates for a wide range of aerospace applications. They have many of the virtues of graphite/epoxies, i.e., high specific strengths and stiffness, and also outstanding thermal/oxidative stability. Yet they are not widely used in the aerospace industry due to problems of procesability. By their nature, modern addition polyimide (PI) resins and prepregs are more complex than epoxies; the key to processing lies in characterizing and understanding the materials. Chemical and rheological characterizations are carried out on several addition polyimide resins and graphite reinforced prepregs, including those based on PMR-15, LARC 160 (AP 22), LARC 160 (Curithane 103) and V378A. The use of a high range torque transducer with a Rheometrics mechanical spectrometer allows rheological data to be generated on prepreg materials as well as neat resins. The use of prepreg samples instead of neat resins eliminates the need for preimidization of the samples and the data correlates well with processing behavior found in the shop. Rheological characterization of the resins and prepregs finds significant differences not readily detected by conventional chemical characterization techniques.

Maximovich, M. G.↗

Dielectric cure monitoring of the 55A filament wound case resin

Studies were conducted to correlate data from dielectric cure monitoring of 55A filament would case resins using the Micromet System II with differential scanning calorimetry and resin strength tests. Strength tests for resin bonding at various time intervals and DSC are standard accepted techniques for monitoriong resin cure cycles. They are time consuming, destructive, and non-continuous. The Micromet System II will yield reliable information on degree of cure and other parameters, which should allow better quality control on filament wound case resin cure.

Mcnutt, R. C.↗

Stability Of A Carbon-Dioxide-Removing Resin

Report describes experiments determing long-term chemical stability of IRA-45, commerical ion-exchange resin candidate for use in removing CO2 from atmosphere of Space Station. In proposed system, cabin air passes through resin, and acidic CO2 absorbed by weakly-basic hydrated diethylenetriamine bonded to porous resin substrate. When resin absorbs all CO2, disconnects from airstream and heated with steam to desorb CO2. Resin reuseable. Removed by post-treating process air with phosphoric acid on charcoal. Other chemicals removed by trace-contaminant-control subsystem of Space Station.

Wydeven, Theodore↗

An infiltration/cure model for manufacture of fabric composites by the resin infusion process

A 1-D infiltration/cure model was developed to simulate fabrication of advanced textile composites by the resin film infusion process. The simulation model relates the applied temperature and pressure processing cycles, along with the experimentally measured compaction and permeability characteristics of the fabric preforms, to the temperature distribution, the resin degree of cure and viscosity, and the infiltration flow front position as a function of time. The model also predicts the final panel thickness, fiber volume fraction, and resin mass for full saturation as a function of compaction pressure. Composite panels were fabricated using the RTM (Resin Transfer Molding) film infusion technique from knitted, knitted/stitched, and 2-D woven carbon preforms and Hercules 3501-6 resin. Fabric composites were fabricated at different compaction pressures and temperature cycles to determine the effects of the processing on the properties. The composites were C-scanned and micrographed to determine the quality of each panel. Advanced cure cycles, developed from the RTM simulation model, were used to reduce the total cure cycle times by a factor of 3 and the total infiltration times by a factor of 2.

Weideman, Mark H.↗

Physical Properties of Synthetic Resin Materials

A study was made to determine the physical properties of synthetic resins having paper, canvas, and linen reinforcements, and of laminated wood impregnated with a resin varnish. The results show that commercial resins have moduli of elasticity that are too low for structural considerations. Nevertheless, there do exist plastics that have favorable mechanical properties and, with further development, it should be possible to produce resin products that compare favorably with the light-metal alloys. The results obtained from tests on Compound 1840, resin-impregnated wood, show that this material can stand on its own merit by virtue of a compressive strength four times that of the natural wood. This increase in compressive strength was accomplished with an increase of density to a value slightly below three times the normal value and corrected one of the most serious defects of the natural product.

Fishbein, Meyer↗

Verification of a two-dimensional infiltration model for the resin transfer molding process

A two-dimensional finite element model for the infiltration of a dry textile preform by an injected resin was verified. The model, which is based on the finite element/control volume technique, determines the total infiltration time and the pressure increase at the mold inlet associated with the RTM process. Important input data for the model are the compaction and permeability behavior of the preform along with the kinetic and rheological behavior of the resin. The compaction behavior for several textile preforms was determined by experimental methods. A power law regression model was used to relate fiber volume fraction to the applied compaction pressure. Results showed a large increase in fiber volume fraction with the initial application of pressure. However, as the maximum fiber volume fraction was approached, the amount of compaction pressure required to decrease the porosity of the preform rapidly increased. Similarly, a power law regression model was used to relate permeability to the fiber volume fraction of the preform. Two methods were used to measure the permeability of the textile preform. The first, known as the steady state method, measures the permeability of a saturated preform under constant flow rate conditions. The second, denoted the advancing front method, determines the permeability of a dry preform to an infiltrating fluid. Water, corn oil, and an epoxy resin, Epon 815, were used to determine the effect of fluid type and viscosity on the steady state permeability behavior of the preform. Permeability values measured with the different fluids showed that fluid viscosity had no influence on the permeability behavior of 162 E-glass and TTI IM7/8HS preforms. Permeabilities measured from steady state and advancing front experiments for the warp direction of 162 E-glass fabric were similar. This behavior was noticed for tests conducted with corn oil and Epon 815. Comparable behavior was observed for the warp direction of the TTI IM7/8HS preform and corn oil. Mold filling and flow visualization experiments were performed to verify the analytical computer model. Frequency dependent electromagnetic sensors were used to monitor the resin flow front as a function of time. For the flow visualization tests, a video camera and high resolution tape recorder were used to record the experimental flow fronts. Comparisons between experimental and model predicted flow fronts agreed well for all tests. For the mold filling tests conducted at constant flow rate injection, the model was able to accurately predict the pressure increase at the mold inlet during the infiltration process. A kinetics model developed to predict the degree of cure as a function of time for the injected resin accurately calculated the increase in the degree of cure during the subsequent cure cycle.

Hammond, Vincent H.↗

Fabrication and Evaluation of Graphite Fiber-Reinforced Polyimide Composite Tube Forms Using Modified Resin Transfer Molding

The techniques necessary for the fabrication of a complex three-dimensional tubular form using a PMR-type resin have been developed to allow for the construction of several tubes with good physical and mechanical properties. Employing established resin transfer molding practices, the relatively non-hazardous AMB-21 in acetone formulation was used to successfully impregnate four layers of AS4 braided graphite fiber preform previously loaded around an aluminum cylindrical core in an enclosed mold cavity. Using heat and vacuum, the solvent was evaporated to form a prepreg followed by a partial imidization and removal of condensation products. The aluminum core was replaced by a silicone rubber bladder and the cure cycle continued to the final stage of 550 F with a bladder internal pressure of 200 lbs/sq in while simultaneously applying a strong vacuum to the prepreg for removal of any additional imidization products. A combination of several modifications to the standard resin transfer molding methodology enabled the mold to 'breathe', allowing the imidization products a pathway for escape. AMB-21 resin was chosen because of the carcinogenic nature of the primary commercial polyimide PMR-15. The AMB-21 resin was formulated using commercially available monomers or monomer precursors and dissolved in a mixture of methyl alcohol and acetone. The viscosity of the resulting monomer solution was checked by use of a Brookfield rheometer and adjusted by adding acetone to an easily pumpable viscosity of about 600 cP. In addition, several types of chromatographic and thermal analyses were of the braids, and excess handling of the preforms broke some of the microscopic fibers, needlessly decreasing the strength of the finished part. In addition, three dimensional braided preforms with fibers along the length of the tube will be significantly stronger in tension than the braided preforms used in this study.

Exum, Daniel B.↗

Flow and Compaction During the Vacuum Assisted Resin Transfer Molding Process

The flow of an epoxy resin and compaction behavior of carbon fiber preform during vacuum- assisted resin transfer molding (VARTM) infiltration was measured using an instrumented tool. Composite panels were fabricated by the VARTM process using SAERTEX(R)2 multi-axial non- crimp carbon fiber fabric and the A.T.A.R.D. SI-ZG-5A epoxy resin. Resin pressure and preform thickness variation was measured during infiltration. The effects of the resin on the compaction behavior of the preform were measured. The local preform compaction during the infiltration is a combination of wetting and spring-back deformations. Flow front position computed by the 3DINFIL model was compared with the experimental data.

Grimsley, Brian W.↗

PETI-298 Prepared by Microwave Synthesis: Neat Resin and Composite Properties

PETI-298 is a high temperature/high performance matrix resin that is processable into composites by resin transfer molding (RTM), resin infusion and vacuum assisted RTM techniques. It is typically synthesized in a polar aprotic solvent from the reaction of an aromatic anhydride and a combination of diamines and endcapped with phenylethynylphthalic anhydride. Microwave synthesis of PETI-298 was investigated as a means to eliminate solvent and decrease reaction time. The monomers were manually mixed and placed in a microwave oven for various times to determine optimum reaction conditions. The synthetic process was subsequently scaled-up to 330g. Three batches were synthesized and combined to give 1 kg of material that was characterized for thermal and rheological properties and compared to PETI-298 prepared by the classic solution based synthetic method. The microwave synthesized PETI-298 was subsequently used to fabricate flat laminates on T650 carbon fabric by RTM. The composite panels were analyzed and mechanical properties determined and compared with those fabricated from PETI-298 prepared by the classic solution method. The microwave synthesis process and characterization of neat resin and carbon fiber reinforced composites fabricated by RTM will be presented. KEY WORDS: Resin Transfer Molding, High Temperature Polymers, Phenylethynyl Terminated Imides, Microwave Synthesis

Smith, Joseph G.↗

Resin film infusion mold tooling and molding method

A mold apparatus and method for resin film infusion molding including an outer mold tool having a facing sheet adapted to support a resin film and preform assembly. The facing sheet includes attachment features extending therefrom. An inner mold tool is positioned on the facing sheet to enclose the resin film and preform assembly for resin film infusion molding. The inner mold tool includes a plurality of mandrels positioned for engagement with the resin film and preform assembly. Each mandrel includes a slot formed therein. A plurality of locating bars cooperate with the slots and with the attachment features for locating the mandrels longitudinally on the outer mold tool.

Burgess, Roger↗

Nontoxic Resins Advance Aerospace Manufacturing

The 2008 NASA Commercial Invention of the Year, PETI-330, is a polyimide matrix resin that performs well at high temperatures and is easily processed into composites in a simple, short curing cycle. Invented by scientists at Langley Research Center, PETI-330 is now licensed to Ube Industries, based in Japan with its American headquarters in New York. In addition to being durable and lightweight, the resin is also nontoxic, which makes it safe for workers to handle. PETI-330 was created specifically for heat-resistant composites formed with resin transfer molding and resin infusion, which formerly could only be used with low temperature resin systems.

Source record↗

One-Dimensional Model for the Ultrasonic Response of Resin-Filled Gaps in Automated Tape Layup Composites

Automated tow placement has become a widely used fabrication technique, especially for large aerospace structures. Robotic heads lay down strips (tows) of preimpregnated fiber along programmed paths. The intention is to lay adjacent tows abutted to one another, but sometimes a gap is left between a tow and the previously-placed tow. If a tow gap exists, it fills with resin during cure, forming a fiber-free volume. In immersion ultrasonic pulse-echo measurements of a cured laminate, the gap can be observed to produce a noticeable echo, without significantly attenuating the back-wall reflection of the laminate. To understand this behavior, we considered a one dimensional model of the composite laminate, with a thin layer having the ultrasonic sound speed and density of neat resin, sandwiched between two layers of material having the sound speed and density of fiber-reinforced composite and surrounded on both sides by water. Neglecting attenuation, we considered the transmission and reflection coefficients of each interface, as well as that of the thin resin layer. Using the initial water/composite reflection as a reference, we computed the relative magnitude of the back surface/water reflection in the presence and in the absence of a resin-only layer, as well as the relative magnitude of the reflection arising from a thin resin layer in composite. While the one-dimensional model did not fully match the measurements, it did qualitatively explain the observed behavior.

Johnston, Patrick H.↗

Modified Epoxy Matrix Resins for Reduced Dependence on Redundant Fasteners in Secondary-Bonded Composite Structures

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making it susceptible to minute quantities of contamination that can lead to weak bonds. No methods currently exist to measure the strength of an adhesive bond nondestructively. For these reasons, regulating organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded, primary-structures to achieve certification for civil transport aircraft. To meet this requirement, manufacturers commonly install redundant fasteners (~105 fasteners in a twin-aisle airframe with composite fuselage and wings), which add tremendous complexity, time and cost, and significantly reduce performance of the airframe. Under NASA’s Convergent Aeronautics Solutions (CAS) Program, the Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy matrix resins to enable reflow and diffusion of the resin at the interface during a secondary bonding/cure process. The mixing process eliminates the material discontinuity at the interface, thereby removing the dependence of bond performance on adhesion across a nearly two-dimensional boundary. The AERoBOND interface is similar to the interlaminar region formed during a co-cure process, so joint performance depends on the cohesive properties of the matrix resin, which can be measured, inspected non-destructively, and certified for flight with fewer redundant fasteners. This presentation describes the ongoing development of stoichiometrically-offset epoxy resins to control the degree of cure in composite joints and enable interfacial mixing during secondary bonding/curing. Details on the resin formulation, laminate fabrication, and mechanical testing will also be presented. The precracked mode-II fracture toughness measured from preliminary AERoBOND joints was similar for joints fabricated with conventional epoxy matrix materials.

thermoset, hardener, prepreg, assembly↗

Molecular Dynamics Investigation of the Structural and Mechanical Properties of Off-Stoichiometric Epoxy Resins

Molecular dynamic (MD) simulations were performed to compute the mechanical properties of off-stoichiometric epoxy resins as a function of hardener/epoxy mixture ratio (r). Properties were characterized in relation to their microscopic structures. Such resins have been used recently for adhesive-free bonding of large-scale composite structures using the co-curing-ply method. In this process, two partially precured composite panels with hardener-poor (HP) off-stoichiometric resins are coupled with ply(ies) of complementary hardener-rich (HR) formulations and then cured simultaneously. This bonding process has the potential to produce reliable and certifiable composite joints without the need for additional fasteners, which are often required for many conventional bonding methods because even small amounts of contamination can cause a weak bond. The reflow and mixing of the HP/HR resin in this bonding process result in a joint with no discernable interface that should not be susceptible to surface contamination. However, incomplete mixing of the two offset resins may result in chemical heterogeneity of the cured polymeric joint. Thus, different r values may be obtained across the joint. Classical MD simulations were performed to compute the Young’s modulus of polymers with different r values and correlate their properties to network structures. High stiffness was associated with molecular packing due to chemical crosslinking, leading to a single network structure. Moreover, the networks became denser as the ratio approached the stoichiometric value r = 1. Thus, the r = 1 systems were single clusters, with high stiffness, high molecular weight, and a high degree of crosslinking. Structural properties such as radius of gyration and mean square displacement were determined to investigate the variation in the stiffness with respect to r. This MD simulation study was validated with experimental measurements.

Chang Woon Jang↗

Resin transfer molding systems and control logic for manufacturing fiber-reinforced composite parts

Presented are manufacturing control systems for fabricating composite-material structures, methods for making/operating such systems, and resin transfer molding techniques for ameliorating race-tracking effects in fiber-reinforced polymer panels. A method for forming a composite-material construction includes confirming, via a system electronic control unit (ECU), that a fiber-based preform is placed in a mold cavity and that opposing mold segments of the molding apparatus are sealed together. A filler, such as a compressible bladder, a cluster of spring-biased pins, or a spray-chopped fiber bed, is introduced into a void between the fiber-based preform and a tool face of one mold segment to thereby eliminate an unwanted resin race track. The system ECU commands a resin pump to inject resin through a primary gate of the molding apparatus and into the mold cavity to thereby impregnate the fiber-based preform with the resin. One or more vents operate to evacuate air from the mold.

Rodgers, William R.↗

Evaluation of two extraction chromatography resins for scandium and titanium separation for medical isotope production

Scandium-47 ( 47 Sc) can be used in nuclear medicine as a therapeutic-diagnostic, or "theragnostic," radioactive medical isotope for cancer detection and treatment. The 47 Sc isotope can be produced through the photonuclear reaction 48 Ti(γ,p) 47 Sc by irradiating enriched 48 Ti target material. The enriched target material necessary for production is costly; 48 TiO 2 costs ~ $\$$1550/g, and targets can be > 50 g ($\$$77,500) to produce medically relevant amounts of 47 Sc. In order to keep costs low, a highly efficient separation of scandium from bulk titanium is desired, along with efficient methods for recycling the target material. Here this research is focused on evaluating efficient methods for the separation of scandium from bulk quantities of titanium using commercially available diglycolamide-based and hydroxamate-based extraction chromatography resins (DGA resin and ZR resin, respectively). The sorption of 47 Sc and Ti on these resins were investigated at varying concentrations of HNO 3 , HCl, H 2 SO 4 , and HF to explore how they might be used in a large-scale production/processing setting.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY

Non-metallic structural materials that act as an electrical insulation are needed for cryogenic power applications. One of the extensively utilized materials is glass fiber reinforced resins (GFRR) and may also be known as GFRP and FRP. They are created from glass fiber cloth that are impregnated with an epoxy resin under pressure and heat. Although the materials based on GFRR have been employed extensively, reports about their dielectric properties at cryogenic temperatures and larger thicknesses are generally lacking in the literature. Therefore to guide electrical apparatus designers for cryogenic applications, GFRR samples with different thicknesses are tested in a liquid nitrogen bath. Scaling relation between the dielectric breakdown strength and the GFFR thickness is established. Their loss tangents are also reported at various frequencies.

36 MATERIALS SCIENCE↗