Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESPIRATORY SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Comparing Radiation Treatments Using Intensity-Modulated Beams, Multiple Arcs, and Single Arcs

Purpose: A dosimetric comparison of multiple static-field intensity-modulated radiation therapy (IMRT), multiarc intensity-modulated arc therapy (IMAT), and single-arc arc-modulated radiation therapy (AMRT) was performed to evaluate their clinical advantages and shortcomings. Methods and Materials: Twelve cases were selected for this study, including three head-and-neck, three brain, three lung, and three prostate cases. An IMRT, IMAT, and AMRT plan was generated for each of the cases, with clinically relevant planning constraints. For a fair comparison, the same parameters were used for the IMRT, IMAT, and AMRT planning for each patient. Results: Multiarc IMAT provided the best plan quality, while single-arc AMRT achieved dose distributions comparable to those of IMRT, especially in the complicated head-and-neck and brain cases. Both AMRT and IMAT showed effective normal tissue sparing without compromising target coverage and delivered a lower total dose to the surrounding normal tissues in some cases. Conclusions: IMAT provides the most uniform and conformal dose distributions, especially for the cases with large and complex targets, but with a delivery time similar to that of IMRT; whereas AMRT achieves results comparable to IMRT with significantly faster treatment delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concurrent Chemoradiotherapy With Helical Tomotherapy for Oropharyngeal Cancer: A Preliminary Result

Purpose: To review the experience with and evaluate the treatment plan for helical tomotherapy for the treatment of oropharyngeal cancer. Methods and Materials: Between November 1, 2006 and January 31, 2009, 10 histologically confirmed oropharyngeal cancer patients were enrolled. All patients received definitive concurrent chemoradiation with helical tomotherapy. The prescription dose to the gross tumor planning target volume, the high-risk subclinical area, and the low-risk subclinical area was 70Gy, 63Gy, and 56Gy, respectively. During radiotherapy, all patients were treated with cisplatin, 30mg/m{sup 2}, plus 5-fluorouracil (425mg/m{sup 2})/leucovorin (30mg/m{sup 2}) intravenously weekly. Toxicity of treatment was scored according to the Common Terminology Criteria for Adverse Events, version 3.0. Several parameters, including maximal or median dose to critical organs, uniformity index, and conformal index, were evaluated from dose-volume histograms. Results: The mean survival was 18 months (range, 7-22 months). The actuarial overall survival, disease-free survival, locoregional control, and distant metastasis-free rates at 18 months were 67%, 70%, 80%, and 100%, respectively. The average for uniformity index and conformal index was 1.05 and 1.26, respectively. The mean of median dose for right side and left side parotid glands was 23.5 and 23.9Gy, respectively. No Grade 3 toxicity for dermatitis and body weight loss and only one instance of Grade 3 mucositis were noted. Conclusion: Helical tomotherapy achieved encouraging clinical outcomes in patients with oropharyngeal carcinoma. Treatment toxicity was acceptable, even in the setting of concurrent chemotherapy. Long-term follow-up is needed to confirm these preliminary findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dynamic Jaws and Dynamic Couch in Helical Tomotherapy

Purpose: To investigate the next generation of helical tomotherapy delivery with dynamic jaw and dynamic couch movements. Methods and Materials: The new technique of dynamic jaw and dynamic couch movements is described, and a comparative planning study is performed. Ten nasopharyngeal cancer patients with skull base infiltration were chosen for this comparison of longitudinal dose profiles using regular tomotherapy delivery, running-start-stop treatment, and dynamic jaw and dynamic couch delivery. A multifocal simultaneous integrated boost concept was used (70.4Gy to the primary tumor and involved lymph nodes; 57.4Gy to the bilateral cervical lymphatic drainage pathways, 32 fractions). Target coverage, conformity, homogeneity, sparing of organs at risk, integral dose, and radiation delivery time were evaluated. Results: Mean parotid dose for all different deliveries was between 24.8 and 26.1Gy, without significant differences. The mean integral dose was lowered by 6.3% by using the dynamic technique, in comparison with a 2.5-cm-field width for regular delivery and 16.7% with 5-cm-field width for regular delivery. Dynamic jaw and couch movements reduced the calculated radiation time by 66% of the time required with regular 2.5-cm-field width delivery (199 sec vs. 595 sec, p < 0.001). Conclusions: The current delivery mode of helical tomotherapy produces dose distributions with conformal avoidance of parotid glands, brain stem, and spinal cord. The new technology with dynamic jaw and couch movements improves the plan quality by reducing the dose penumbra and thereby reducing the integral dose. In addition, radiation time is reduced by 66% of the regular delivery time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Applications of Volumetric Modulated Arc Therapy

Purpose: To present treatment planning case studies for several treatment sites for which volumetric modulated arc therapy (VMAT) could have a positive impact; and to share an initial clinical experience with VMAT for stereotactic body radiotherapy (SBRT). Methods and Materials: Four case studies are presented to show the potential benefit of VMAT compared with conformal and intensity-modulated radiotherapy (IMRT) techniques in pediatric cancer, bone marrow-sparing whole-abdominopelvic irradiation (WAPI), and SBRT of the lung and spine. Details of clinical implementation of VMAT for SBRT are presented. The VMAT plans are compared with conventional techniques in terms of dosimetric quality and delivery efficiency. Results: Volumetric modulated arc therapy reduced the treatment time of spine SBRT by 37% and improved isodose conformality. Conformal and VMAT techniques for lung SBRT had similar dosimetric quality, but VMAT had improved target coverage and took 59% less time to deliver, although monitor units were increased by 5%. In a complex pediatric pelvic example, VMAT reduced treatment time by 78% and monitor units by 25% compared with IMRT. A double-isocenter VMAT technique for WAPI can spare bone marrow while maintaining good delivery efficiency. Conclusions: Volumetric modulated arc therapy is a new technology that may benefit different patient populations, including pediatric cancer patients and those undergoing concurrent chemotherapy and WAPI. Volumetric modulated arc therapy has been used and shown to be beneficial for significantly improving delivery efficiency of lung and spine SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Radiosurgery for Patients With Brain Metastases From Small Cell Lung Cancer

Background: Patients with small-cell lung cancer have a high likelihood of developing brain metastases. Many of these patients will have prophylactic cranial irradiation (PCI) or eventually undergo whole brain radiation therapy (WBRT). Despite these treatments, a large number of these patients will have progression of their intracranial disease and require additional local therapy. Stereotactic radiosurgery (SRS) is an important treatment option for such patients. Methods: We retrospectively reviewed the charts of 44 patients with brain metastases from small-cell lung cancer treated with gamma knife SRS. Multivariate analysis was used to determine significant prognostic factors influencing survival. Results: The median follow-up from SRS in this patient population was 9 months (1-49 months). The median overall survival (OS) was 9 months after SRS. Karnofsky performance status (KPS) and combined treatment involving WBRT and SRS within 4 weeks were the two factors identified as being significant predictors of increased OS (p = 0.033 and 0.040, respectively). When comparing all patients, patients treated with a combined approach had a median OS of 14 months compared to 6 months if SRS was delivered alone. We also compared the OS times from the first definitive radiation: WBRT, WBRT and SRS if combined therapy was used, and SRS if the patient never received WBRT. The median survival for those groups was 12, 14, and 13 months, respectively, p = 0.19. Seventy percent of patients had follow-up magnetic resonance imaging available for review. Actuarial local control at 6 months and 12 months was 90% and 86%, respectively. Only 1 patient (2.2%) had symptomatic intracranial swelling related to treatment, which responded to a short course of steroids. New brain metastases outside of the treated area developed in 61% of patients at a median time of 7 months; 81% of these patients had received previous WBRT. Conclusions: Stereotactic radiosurgery for small-cell lung carcinoma brain metastases provided safe and effective local tumor control in the majority of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Peripheral Doses from Noncoplanar IMRT for Pediatric Radiation Therapy

The use of noncoplanar intensity-modulated radiation therapy (IMRT) might result in better sparing of some critical organs because of a higher degree of freedom in beam angle optimization. However, this can lead to a potential increase in peripheral dose compared with coplanar IMRT. The peripheral dose from noncoplanar IMRT has not been previously quantified. This study examines the peripheral dose from noncoplanar IMRT compared with coplanar IMRT for pediatric radiation therapy. Five cases with different pediatric malignancies in head and neck were planned with both coplanar and noncoplanar IMRT techniques. The plans were performed such that the tumor coverage, conformality, and dose uniformity were comparable for both techniques. To measure the peripheral doses of the 2 techniques, thermoluminescent dosimeters (TLD) were placed in 10 different organs of a 5-year-old pediatric anthropomorphic phantom. With the use of noncoplanar beams, the peripheral doses to the spinal cord, bone marrow, lung, and breast were found to be 1.8-2.5 times of those using the coplanar technique. This is mainly because of the additional internal scatter dose from the noncoplanar beams. Although the use of noncoplanar technique can result in better sparing of certain organs such as the optic nerves, lens, or inner ears depending on how the beam angles were optimized on each patient, oncologists should be alert of the possibility of significantly increasing the peripheral doses to certain radiation-sensitive organs such as bone marrow and breast. This might increase the secondary cancer risk to patients at young age.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Multicenter Retrospective Analysis of Survival Outcome Following Postoperative Chemoradiotherapy in Non-Small-Cell Lung Cancer Patients With N2 Nodal Disease

Purpose: To retrospectively evaluate the role of postoperative chemoradiotherapy (POCRT) in patients with completely resected non-small-cell lung cancer (NSCLC) with N2 lymph node involvement. Methods and Materials: This study included 183 patients from four centers in southwest China who underwent radical section of Stage III-N2 NSCLC without any preoperative therapy. One hundred and four were treated with POCRT and 79 with postoperative chemotherapy (POCT) alone. The median radiation dose to clinical target volume (CTV) was 50 Gy (varying between 48 and 54 Gy), whereas the cycles of platinum-based chemotherapy ranged from two to six with a median of four. Results: The median duration of follow-up was 72 months. The 5-year overall survival rate (OS) was 30.5% in the POCRT group, and 14.4% in the POCT group (p = 0.007). The 5-year disease-free survival rate (DFS) was 22.2% in POCRT group and 9.3% in POCT group (p = 0.003). In a multivariate analysis, N1 nodal involvement (N1+/N2+) was associated with significantly worse OS (HR = 1.454, 95% CI, 1.012-2.087, p = 0.043) and DFS (HR = 1.685, 95% CI, 1.196-2.372, p = 0.003). Absence of radiotherapy and treatment with fewer than three cycles of chemotherapy both were poor prognostic factors for both OS and DFS. Conclusions: As compared with chemotherapy alone, adjuvant treatment with both radiotherapy and chemotherapy improves survival in patients with completely resected Stage III-N2 nodal disease in NSCLC. Future study of treatment modality with radiotherapy and chemotherapy is warranted, especially focusing on both N1 and N2 nodal status.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Follow-Up of the Percutaneous Treatment of Hydatid Cyst in the Adrenal Gland: A Case Report and Review of the Literature

Although the most involved organs are liver and lung, hydatid cysts occur in adrenal glands, rarely, and constitute only 0.5% of hydatid cysts. Herein, we demonstrate and discuss, for the first time in the literature to the best of our knowledge, the radiological features of adrenal hydatid disease and evaluate the long-term results (57 months of follow-up) of the percutaneous treatment of hydatid cyst in the adrenal gland in a patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cognitive Function Before and After Intensity-Modulated Radiation Therapy in Patients With Nasopharyngeal Carcinoma: A Prospective Study

Purpose: To evaluate the effects of radiation therapy (RT) on neurocognitive function in patients with nasopharyngeal carcinoma (NPC). Methods and Materials: Thirty patients with NPC treated with intensity-modulated RT were included. Dose-volume histograms of the temporal lobes were obtained in every patient. Neurocognitive tests were administered individually to each patient 1 day before initiation of RT and at least 12 months after completion of RT. Cognitive functioning status was evaluated as change in scores over time. Results: Among the total of 30 patients, 23 patients (76.7%) had significantly lower post-RT cognitive functioning scores compared with their pre-RT scores (p = 0.033). The cognitive functioning scores had significantly declined in the domains of short-term memory, language abilities, and list-generating fluency (p = 0.020, 0.023, and 0.001, respectively). Compared with patients with a mean dose to the temporal lobes of 36 Gy or less, patients with a mean dose of greater than 36 Gy had a significantly greater reduction in cognitive functioning scores (p = 0.017). Patients in whom V60 of the temporal lobes (i.e., the percentage of the temporal lobe volume that had received >60 Gy) was greater than 10% also had a greater reduction in cognitive functioning scores than those in whom V60 was 10% or less (p = 0.039). Conclusions: The results of our study indicated that RT could have deleterious effects on cognitive function in patients with NPC. Efforts should be made to reduce the radiation dose and irradiated volume of temporal lobes without compromising the coverage of target volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ipsilateral Irradiation for Oral and Oropharyngeal Carcinoma Treated With Primary Surgery and Postoperative Radiotherapy

Purpose: The purpose was to evaluate the contralateral nodal control (CLNC) in postoperative patients with oral and oropharyngeal cancer treated with ipsilateral irradiation of the neck and primary site. Late radiation-induced morbidity was also evaluated. Methods and Materials: The study included 123 patients with well-lateralized squamous cell carcinomas treated with surgery and unilateral postoperative irradiation. Most patients had tumors of the gingiva (41%) or buccal mucosa (21%). The majority of patients underwent surgery of the ipsilateral neck (n = 102 [83%]). The N classification was N0 in 73 cases (59%), N1 or N2a in 23 (19%), and N2b in 27 cases (22%). Results: Contralateral metastases developed in 7 patients (6%). The 5-year actuarial CLNC was 92%. The number of lymph node metastases was the only significant prognostic factor with regard to CLNC. The 5-year CLNC was 99% in N0 cases, 88% in N1 or N2a cases, and 73% in N2b cases (p = 0.008). Borderline significance (p = 0.06) was found for extranodal spread. Successful salvage could be performed in 71% of patients with contralateral metastases. The prevalence of Grade 2 or higher xerostomia was 2.6% at 5 years. Conclusions: Selected patients with oral or oropharyngeal carcinoma treated with primary surgery and postoperative ipsilateral radiotherapy have a very high CLNC with a high probability of successful salvage in case of contralateral metastases. However, bilateral irradiation should be applied in case of multiple lymph node metastases in the ipsilateral neck, particularly in the presence of extranodal spread. The incidence of radiation-induced morbidity is considerably lower as observed after bilateral irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Stereotactic Body Radiation Therapy for Clinically Challenging Cases of Centrally and Superiorly Located Stage I Non-Small-Cell Lung Cancer

Purpose: To minimize toxicity while maintaining tumor coverage with stereotactic body radiation therapy (SBRT) for centrally or superiorly located stage I non-small-cell lung cancer (NSCLC), we investigated passive-scattering proton therapy (PSPT) and intensity-modulated proton therapy (IMPT). Methods and Materials: Fifteen patients with centrally or superiorly located (within 2 cm of critical structures) stage I NSCLC were treated clinically with three-dimensional photon SBRT (50 Gy in 4 fractions). The photon SBRT plan was compared with the PSPT and IMPT plans. The maximum tolerated dose (MTD) was defined as the dose that exceeded the dose--volume constraints in the critical structures. Results: Only 6 photon plans satisfied the >95% planning target volume (PTV) coverage and MTD constraints, compared to 12 PSPT plans (p = 0.009) and 14 IMPT plans (p = 0.001). Compared with the photon SBRT plans, the PSPT and IMPT plans significantly reduced the mean total lung dose from 5.4 Gy to 3.5 Gy (p < 0.001) and 2.8 Gy (p < 0.001) and reduced the total lung volume receiving 5 Gy, 10 Gy, and 20 Gy (p < 0.001). When the PTV was within 2 cm of the critical structures, the PSPT and IMPT plans significantly reduced the mean maximal dose to the aorta, brachial plexus, heart, pulmonary vessels, and spinal cord. Conclusions: For centrally or superiorly located stage I NSCLC, proton therapy, particularly IMPT, delivered ablative doses to the target volume and significantly reduced doses to the surrounding normal tissues compared with photon SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linear Accelerator-Based Intensity-Modulated Total Marrow Irradiation Technique for Treatment of Hematologic Malignancies: A Dosimetric Feasibility Study

Purpose: To investigate the dosimetric feasibility of linear accelerator-based intensity-modulated total marrow irradiation (IM-TMI) in patients with hematologic malignancies. Methods and Materials: Linear accelerator-based IM-TMI treatment planning was performed for 9 patients using the Eclipse treatment planning system. The planning target volume (PTV) consisted of all the bones in the body from the head to the mid-femur, except for the forearms and hands. Organs at risk (OAR) to be spared included the lungs, heart, liver, kidneys, brain, eyes, oral cavity, and bowel and were contoured by a physician on the axial computed tomography images. The three-isocenter technique previously developed by our group was used for treatment planning. We developed and used a common dose-volume objective method to reduce the planning time and planner subjectivity in the treatment planning process. Results: A 95% PTV coverage with the 99% of the prescribed dose of 12 Gy was achieved for all nine patients. The average dose reduction in OAR ranged from 19% for the lungs to 68% for the lenses. The common dose-volume objective method decreased the planning time by an average of 35% and reduced the inter- and intra- planner subjectivity. Conclusion: The results from the present study suggest that the linear accelerator-based IM-TMI technique is clinically feasible. We have demonstrated that linear accelerator-based IM-TMI plans with good PTV coverage and improved OAR sparing can be obtained within a clinically reasonable time using the common dose-volume objective method proposed in the present study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of engineered nanoparticles on vasomotor responses in rat intrapulmonary artery

Pulmonary circulation could be one of the primary vascular targets of finest particles that can deeply penetrate into the lungs after inhalation. We investigated the effects of engineered nanoparticles on vasomotor responses of small intrapulmonary arteries using isometric tension measurements. Acute in vitro exposure to carbon nanoparticles (CNP) decreased, and in some case abolished, the vasomotor responses induced by several vasoactive agents, whereas acute exposure to titanium dioxide nanoparticles (TiO{sub 2}NP) did not. This could be attributed to a decrease in the activity of those vasoactive agents (including PGF{sub 2{alpha}}, serotonin, endothelin-1 and acetylcholine), as suggested when they were exposed to CNP before being applied to arteries. Also, CNP decreased the contraction induced by 30 mM KCl, without decreasing its activity. After endoplasmic reticulum calcium stores depletion (by caffeine and thapsigargin), CaCl{sub 2} addition induced a contraction, dependent on Store-Operated Calcium Channels that was not modified by acute CNP exposure. Further addition of 30 mM KCl elicited a contraction, originating from activation of Voltage-Operated Calcium Channels that was diminished by CNP. Contractile responses to PGF{sub 2{alpha}} or KCl, and relaxation to acetylcholine were modified neither in pulmonary arteries exposed in vitro for prolonged time to CNP or TiO{sub 2}NP, nor in those removed from rats intratracheally instilled with CNP or TiO{sub 2}NP. In conclusion, prolonged in vitro or in vivo exposure to CNP or TiO{sub 2}NP does not affect vasomotor responses of pulmonary arteries. However, acute exposure to CNP decreases contraction mediated by activation of Voltage-Operated, but not Store-Operated, Calcium Channels. Moreover, interaction of some vasoactive agents with CNP decreases their biological activity that might lead to misinterpretation of experimental data.

60 APPLIED LIFE SCIENCES↗

Organ Preservation With Concurrent Chemoradiation for Advanced Laryngeal Cancer: Are We Succeeding?

Purpose: To determine the rates of organ preservation and function in patients with advanced laryngeal and hypopharyngeal carcinomas treated with concurrent chemoradiotherapy (CRT). Methods and Materials: Between April 1999 and September 2005, 82 patients with advanced laryngeal (67%) and hypopharyngeal carcinomas (33%) underwent conventional radiotherapy and concurrent platinum-based chemotherapy with curative intent. Sixty-two patients were male (75.6%). The median age was 59 years. Eighteen patients (22%) were in Stage III and 64 (78%) were in Stage IV. The median radiation dose was 70 Gy. The median potential follow-up was 3.9 years. Results: Overall survival and disease-free survival were respectively 63% and 73% at 3 years. Complete response rate from CRT was 75%. Nineteen patients (23%) experienced significant long-term toxicity after CRT: 6 (7.3%) required a percutaneous endoscopic gastrostomy, 5 (6%) had persistent Grade 2 or 3 dysphagia, 2 (2.4%) had pharyngoesophageal stenosis requiring multiple dilations, 2 (2.4%) had chronic lung aspiration, and 7 (8.5%) required a permanent tracheostomy. Four patients (4.9%) underwent laryngectomy without pathologic evidence of disease. At last follow-up, 5 (6%) patients were still dependent on a gastrostomy. Overall, 42 patients (52%) were alive, in complete response, with a functional larynx and no other major complications. Conclusions: In our institution, CRT for advanced hypopharyngeal and laryngeal carcinoma has provided good overall survival and locoregional control in the majority of patients, but a significant proportion did not benefit from this approach because of either locoregional failure or late complications. Better organ preservation approaches are necessary to improve locoregional control and to reduce long-term toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intensity-Modulated Radiotherapy in the Treatment of Oropharyngeal Cancer: Clinical Outcomes and Patterns of Failure

Purpose: To report outcomes, failures, and toxicities in patients treated with intensity-modulated radiotherapy (IMRT) for squamous cell carcinoma of the oropharynx. Methods And Materials: Between Aug 2001 and Oct 2007, 107 patients were treated with IMRT with curative intent at Stanford University. Twenty-two patients were treated postoperatively, and 85 were treated definitively. Concurrent platinum-based chemotherapy was administered to 86 patients (80%) and cetuximab to 8 patients (7%). The prescribed dose was 66 Gy at 2.2 Gy/fraction for definitively treated cases and 60 Gy at 2 Gy/fraction for postoperative cases. Median follow-up was 29 months among surviving patients (range, 4-105 months). Results: Eight patients had persistent disease or local-regional failure at a median of 6.5 months (range, 0-9.9 months). Six local failures occurred entirely within the high-risk clinical target volume (CTV) (one with simultaneous distant metastasis). One patient relapsed within the high- and intermediate-risk CTV. One patient had a recurrence at the junction between the IMRT and low-neck fields. Seven patients developed distant metastasis as the first site of failure. The 3-year local-regional control (LRC), freedom from distant metastasis, overall survival, and disease-free survival rates were 92%, 92%, 83%, and 81%, respectively. T stage (T4 vs. T1-T3) was predictive of poorer LRC (p = 0.001), overall survival (p = 0.001), and disease-free survival (p < 0.001) rates. Acute toxicity consisted of 58% grade 3 mucosal and 5% grade 3 skin reactions. Six patients (6%) developed grade >=3 late complications. Conclusions: IMRT provides excellent LRC for oropharyngeal squamous cell carcinoma. Distant metastases are a major failure pattern. No marginal failures were observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simple Carotid-Sparing Intensity-Modulated Radiotherapy Technique and Preliminary Experience for T1-2 Glottic Cancer

Purpose: To investigate the dosimetry and feasibility of carotid-sparing intensity-modulated radiotherapy (IMRT) for early glottic cancer and to report preliminary clinical experience. Methods and Materials: Digital Imaging and Communications in Medicine radiotherapy (DICOM-RT) datasets from 6 T1-2 conventionally treated glottic cancer patients were used to create both conventional IMRT plans. We developed a simplified IMRT planning algorithm with three fields and limited segments. Conventional and IMRT plans were compared using generalized equivalent uniform dose and dose-volume parameters for in-field carotid arteries, target volumes, and organs at risk. We have treated 11 patients with this simplified IMRT technique. Results: Intensity-modulated radiotherapy consistently reduced radiation dose to the carotid arteries (p < 0.05) while maintaining the clinical target volume coverage. With conventional planning, median carotid V35, V50, and V63 were 100%, 100%, and 69.0%, respectively. With IMRT planning these decreased to 2%, 0%, and 0%, respectively (p < 0.01). Radiation planning and treatment times were similar for conventional radiotherapy and IMRT. Treatment results have been excellent thus far. Conclusions: Intensity-modulated radiotherapy significantly reduced unnecessary radiation dose to the carotid arteries compared with conventional lateral fields while maintaining clinical target volume coverage. Further experience and longer follow-up will be required to demonstrate outcomes for cancer control and carotid artery effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Development and Clinical Use of a Beam ON-LINE PET System Mounted on a Rotating Gantry Port in Proton Therapy

Purpose: To verify the usefulness of our developed beam ON-LINE positron emission tomography (PET) system mounted on a rotating gantry port (BOLPs-RGp) for dose-volume delivery-guided proton therapy (DGPT). Methods and Materials: In the proton treatment room at our facility, a BOLPs-RGp was constructed so that a planar PET apparatus could be mounted with its field of view covering the iso-center of the beam irradiation system. Activity measurements were performed in 48 patients with tumors of the head and neck, liver, lungs, prostate, and brain. The position and intensity of the activity were measured using the BOLPs-RGp during the 200 s immediately after the proton irradiation. Results: The daily measured activity images acquired by the BOLPs-RGp showed the proton irradiation volume in each patient. Changes in the proton-irradiated volume were indicated by differences between a reference activity image (taken at the first treatment) and the daily activity-images. In the case of head-and-neck treatment, the activity distribution changed in the areas where partial tumor reduction was observed. In the case of liver treatment, it was observed that the washout effect in necrotic tumor cells was slower than in non-necrotic tumor cells. Conclusions: The BOLPs-RGp was developed for the DGPT. The accuracy of proton treatment was evaluated by measuring changes of daily measured activity. Information about the positron-emitting nuclei generated during proton irradiation can be used as a basis for ensuring the high accuracy of irradiation in proton treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Study of the Necessity of Replanning Before the 25th Fraction During the Course of Intensity-Modulated Radiotherapy for Patients With Nasopharyngeal Carcinoma

Purpose: To quantify the target and normal structures on dose distributing variations during intensity-modulated radiotherapy (IMRT) and to assess the value of replanning for nasopharyngeal carcinoma (NPC) patients. Methods and Materials: Twenty-eight NPC patients treated with IMRT were recruited. The IMRT was delivered in 33 fractions, to 70 to 76Gy, to the gross tumor volume (GTV). Before the 25th fraction of IMRT, a new simulation computed tomography (CT) scan was acquired for all patients. According to the dose constraint criterion in the Radiation Therapy Oncology Group (RTOG) 0225 protocol, the replanning was generated on the new simulation CT. With the Quality Assessment Center of a CORVUS 6.3 treatment planning system, a phantom plan was generated for each patient by applying the beam configurations of the initial plan to the anatomy of the new simulation CT. The dose-volume histograms of the phantom plan were compared with the replanning. Results: The percentage of prescription dose delivered to the clinical target volume (CTV1) was significantly increased by 4.91% +- 10.89%, whereas the maximum dose to the spinal cord, mean dose to the left parotid, and V30 to the right parotid were significantly decreased by 5.00 +- 9.23Gy, 4.23 +- 10.03Gy, and 11.47% +- 18.89% respectively in the replanning, compared with the phantom plan (p < 0.05). Based on the dose constraint criterion in the RTOG0225 protocol, 50% of phantom plans (14/28) were out of limit for the dose to the normal critical structures, whereas no plan was out of limit in replanning (p < 0.001). Conclusion: Replanning for patients with NPC before the 25th fraction during IMRT helps to ensure adequate dose to the target volumes and safe doses to critical normal structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗