Search NASA⌕ Search

SEARCH · Search NASA

Results for “RF Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Microscopic examination of rf-cavity-quality niobium films through local nonlinear microwave response

The performance of superconducting radio-frequency (SRF) cavities is sometimes limited by local defects. To investigate the rf properties of these local defects, especially those that nucleate rf magnetic vortices, a near-field magnetic microwave microscope is employed. Local third-harmonic response ( P 3 f ) and its temperature dependence and rf power dependence are measured for one Nb / Cu film grown by direct current magnetron sputtering (DCMS) and six Nb / Cu films grown by high-power impulse magnetron sputtering (HiPIMS) with systematic variation of deposition conditions. Five out of the six HiPIMS Nb / Cu films show a strong third-harmonic response that is likely coming from rf vortex nucleation due to a low- T c surface defect with a transition temperature between 6.3 and 6.8 K, suggesting that this defect is a generic feature of air-exposed HiPIMS Nb / Cu films. A phenomenological model of surface-defect grain boundaries hosting a low- T c impurity phase is introduced and studied with time-dependent Ginzburg-Landau (TDGL) simulations of probe-sample interaction to better understand the measured third-harmonic response. The simulation results show that the third-harmonic response of rf vortex nucleation caused by surface defects exhibits the same general features as the data, including peaks in third-harmonic response with temperature, and their shift and broadening with higher microwave amplitude. We find that the parameters of the phenomenological model (the density of surface defects that nucleate rf vortices and the depth an rf vortex travels through these surface defects) vary systematically with film deposition conditions. From the point of view of these two properties, the Nb / Cu film that is most effective at reducing the nucleation of rf vortices associated with surface defects can be identified. Published by the American Physical Society 2024

Wang, Chung-Yang (ORCID:0000000184299633)↗

RF radiation from lightning

Radiation from lightning in the RF band from 3-300 MHz were monitored. Radiation in this frequency range is of interest as a potential vehicle for monitoring severe storms and for studying the lightning itself. Simultaneous measurements were made of RF radiation and fast and slow field changes. Continuous analogue recordings with a system having 300 kHz of bandwidth were made together with digital records of selected events (principally return strokes) at greater temporal resolution. The data reveal patterns in the RF radiation for the entire flash which are characteristic of flash type and independent of the frequency of observation. Individual events within the flash also have characteristic RF patterns. Strong radiation occurs during the first return strokes, but delayed about 20 micron sec with respect to the begining of the return stroke; whereas, RF radiation from subsequent return strokes tends to be associated with cloud processes preceding the flash with comparatively little radiation occurring during the return stroke itself.

Levine, D. M.↗

Validation of Radio Frequency Telemetry Concept in the Presence of Biological Tissue-Like Stratified Media

In this paper we discuss a novel radio frequency (RF) telemetry concept for biomedical applications. The concept consists of a miniaturized spiral inductor/antenna for bio-MEMS sensors and an external pick-up antenna integrated into a handheld device. The measured relative signal strength in the presence of biological phantoms ranged from 5.9 to 7.5 dB for antenna separations of 5 and 10 cm. These relative signal strengths are easily measurable, therefore validating the RF telemetry concept for biomedical applications.

Miranda, Felix A.↗

Electron density measurements during the NLC-91 campaign

A Super Arcas rocket, MISTI B, containing DC and RF probes, was launched as a part of the PMSE (Polar Mesosphere Summer Echoes) Salvo during the NLC-91 (Noctilucent Cloud) campaign to measure electron density irregularities with high spatial resolution. Measurements of large and small scale structures in the electron density were made on rocket ascent and descent at the altitudes of 86.5 and 88.5 +/- 0.5 km corresponding to the two altitudes of strongest backscatter recorded by the nearby CUPRI (Cornell University Portable Radar Interferometer) radar. Power spectra of the fluctuations shows two different structuring and scattering mechanisms exist at altitudes only 1 km apart. Since the rocket apogee was 89 km, the rocket was in the height range 88.5 +/- 0.5 km for 30 seconds giving an unusual measurement of horizontal structure over a distance of 5.5 km. Using the simultaneous DC and RF probe measurements of electron depletions and sharp gradient in the lower layer, the role of aerosols in creating these depletions and gradients is speculated upon.

Ulwick, J. C.↗

Diagnostics of seeded RF plasmas: An experimental study related to the gaseous core reactor

Measurements of the temperature profiles in an RF argon plasma were made over magnetic field intensities ranging from 20 amp turns/cm to 80 amp turns/cm. The results were compared with a one-dimensional numerical treatment of the governing equations and with an approximate closed form analytical solution that neglected radiation losses. The average measured temperatures in the plasma compared well with the numerical treatment, though the experimental profile showed less of an off center temperature peak than predicted by theory. This may be a result of the complex turbulent flow pattern present in the experimental torch and not modeled in the numerical treatment. The radiation term cannot be neglected for argon at the power levels investigated. The closed form analytical approximation that neglected radiation led to temperature predictions on the order of 1000 K to 2000 K higher than measured or predicted by the numerical treatment which considered radiation losses.

Thompson, S. D.↗

Measurements of uranium mass confined in high density plasmas

An X-ray absorption method for measuring the amount of uranium confined in high density, rf-heated uranium plasmas is described. A comparison of measured absorption of 8 keV X-rays with absorption calculated using Beer Law indicated that the method could be used to measure uranium densities from 3 times 10 to the 16th power atoms/cu cm to 5 times 10 to the 18th power atoms/cu cm. Tests were conducted to measure the density of uranium in an rf-heated argon plasma with UF6 infection and with the power to maintain the discharge supplied by a 1.2 MW rf induction heater facility. The uranium density was measured as the flow rate through the test chamber was varied. A maximum uranium density of 3.85 times 10 to the 17th power atoms/cu cm was measured.

Stoeffler, R. C.↗

Langmuir Probe Distortions and Probe Compensation in an Inductively Coupled Plasma

In many RF discharges, Langmuir probe measurements are usually made against a background of sinusoidal (and not so sinusoidal) fluctuations in the plasma parameters such as the plasma potential (Vp), the electron number density (ne), and the electron temperature (Te). The compensation of sinusoidal fluctuations in Vp has been extensively studied and is relatively well understood. Less attention has been paid to the possible distortions introduced by small fluctuations in plasma density and/or plasma temperature, which may arise in the sheath and pre-sheath regions of RF discharges. Here, we present the results of a model simulation of probe characteristics subject to fluctuations in both Vp and ne. The modeling of probe distortion due to possible fluctuations in Te is less straightforward. A comparison is presented of calculations with experimental measurements using a compensated and uncompensated Langmuir probe in an inductively coupled GEC reference cell plasma, operating on Ar and Ar/CF4 mixtures. The plasma parameters determined from the compensated probe characteristics are compared to previous measurements of others made in similar discharges, and to our own measurements of the average electron density derived from electrical impedance measurements.

Ji, J. S.↗

A ten-stage electrostatic depressed collector for improving klystron efficiency.

A ten-stage electrostatic depressed collector, designed with the aid of an analog computer, was tested on a 1-kW CW 750-MHz klystron. Excellent correlation was achieved between computed and measured performance under varying conditions of RF drive. At full RF power output approximately 60 per cent of the spent beam energy was recovered by use of the depressed collector. The net power conversion efficiency of the tube was raised from its undepressed value of 54.3 per cent to approximately 70.9 per cent. At one-half full power output, a collector efficiency of 70 per cent was measured. At zero RF power output collector efficiency was 80 per cent. To achieve these results it was necessary to install a small focusing coil between the final drift tube and the collector. No spurious oscillations or instabilities were detected when collector depression was employed, nor was electron backstreaming increased significantly. Intentional short circuiting of adjacent collector electrode pairs was shown to cause only minor degradation in collector performance.

Neugebauer, W.↗

Ammonia generation in Ns pulse and Ns pulse/RF discharges over a catalytic surface

Plasma-catalytic ammonia synthesis in a ns pulse discharge and a 'hybrid' ns pulse/RF discharge in plane-to-plane geometry is studied by Fourier Transform infrared absorption spectroscopy. The data are taken in a preheated H 2 –N 2 mixture, with and without Ni/γ-Al 2 O 3 or Co/γ-Al 2 O 3 catalyst placed in the discharge section. The measurement results are taken using two different approaches. The first is a 'single-stage' process, where a ns pulse discharge in the H 2 –N 2 mixture is sustained continuously. In this case, the ammonia yield increases slowly, over a period of tens of minutes. The second is a 'two-stage' process, where the catalyst is first activated by the ns pulse discharge sustained in pure nitrogen, and then the activated catalyst is exposed to the H 2 –N 2 flow, with or without the discharge. In this case, a strong overshoot of the NH 3 number density at the reactor exit is detected, by over a factor of two compared to the single-stage process. After the initial overshoot, the ammonia yield gradually decreases to the 'single stage' value (with the discharge on), or to near zero (with the discharge off). The results demonstrate that the ammonia yield in the plasma-catalytic reactor is controlled by the N atom accumulation on the catalyst surface, which reacts with H atoms thermally dissociated on the catalyst or generated in the plasma. The results also show that the plasma-catalytic ammonia yield is significantly higher compared to that in the ns pulse discharge without the catalyst. The accumulation of H atoms on the catalyst, with their subsequent reactions with N atoms generated in the plasma, is of relatively minor importance at the present conditions. An additional series of measurements was made with a sub-breakdown RF waveform overlapped with the ns pulse discharge train, to enhance the vibrational excitation of nitrogen. The ammonia yield measured with the RF waveform added is approximately 20% higher compared to that at the baseline ns pulse discharge conditions, both with and without the catalyst. This effect is weaker compared to that of the catalyst activation by N atoms. Additional data are necessary to isolate the possible effect of the vibrationally excited N 2 molecules on the ammonia synthesis in the plasma catalytic reactions.

surface reactions↗

Temporal evolution of collisionless sheaths

Experimental measurements have been performed to determine the temporal evolution of Langmuir sheaths near an electrode to which a negative step bias is applied in a collisionless argon plasma. The plasma was produced by a hot-filament discharge in a multidipole device. Plasma potential data were obtained using emissive probes with two different techniques: time-resolved sampling and time-averaged techniques. The sheath is found to initially form close to the electrode, to extend to a maximum separation, and to contract to a steady-state value. The time scale required to reach a steady state is close to the time scale of the presheath relaxation. Characteristics of sheaths in RF plasmas are also measured using a parallel-plate plasma capacitor. It is observed that the plasma potential profile has significant variation with frequency, even for frequencies as low as 1 kHz which are far below the ion plasma frequency (about 1 MHz).

Cho, M. H.↗

A Method for In-Situ Q₀ Measurements of High-Quality SRF Resonators

Accelerator projects such as LCLS-II naturally require low-loss superconducting (SRF) cavities. Due to strong demand for improving intrinsic quality factor (Q₀), importance of accurate cavity characterization increases. We propose a method to measure Q₀ in situ for an SRF resonator installed in its cryogenic module and connected with a RF feed source via a fixed RF coupler. The method exploits measurements of a response for an SRF resonator fed by an amplitude-modulated signal. Such a signal can be synthesized as a beat-wave composed of two frequencies that are close to the resonant frequency. Analyzing the envelope of the reflected signal, one can find the difference in reflection for the chosen frequencies and use them to compute the intrinsic Q. We also develop the methodology to carry out measurements of Q₀ at the nominal cavity operating voltage. We verified our method in experiments with a room temperature copper resonator and with two SRF resonators including Fermilab’s 650 MHz cavity and JLab’s 1500 MHz cavity.

43 PARTICLE ACCELERATORS↗

High-Temperature RF Transmission Loss Characteristics of Platinum–Inconel 600 and Platinum–304 Steel Interconnects

Radio frequency (RF) transmission losses that occur at electronic interconnects is currently an important limitation of wireless sensors and other electronic device packages that must operate in high-temperature environments. Herein, in-situ RF transmission losses were measured for two types of interconnects: platinum (Pt) wire bonded to an Inconel 600 coaxial cable; and Pt-wire bonded to a block of 304 steel. Heating the Pt wire/Inconel interconnects at 800 °C for up to 200 hours were found to be very stable with no measurable transmission losses. In contrast, Pt wire/304 steel block interconnects examined over similar test periods at 800 °C exhibited gradual increases in transmission losses leveling off at 10, 38 and 85 mdB at 400 MHz, 700 MHz, and 1 GHz, respectively. Increasing the test temperature to 900 °C caused further elevated transmission losses of 30, 70 and 108 mdB at the same reported frequencies. By comparison, temperature cycling of the Pt wire/304 steel interconnects between room temperature and 900 °C was found to cause more significant degradation. In particular, four thermal cycles from room temperature to 900 °C resulted in losses of 75, 271, and 482 mdB at the same reported frequencies. Parabolic oxidation relative to the RF skin depth in the 304 steel block at the tested frequencies are discussed as possible reasons for the transmission losses during the isothermal soaks, whereas interconnect degradation due to differences in thermal expansion between Pt and 304 steel are primarily responsible for transmission losses caused by high temperature cycling.

304 steel↗

Historical total ozone radiative forcing derived from CMIP6 simulations

Radiative forcing (RF) time series for total ozone from 1850 up to the present day are calculated based on historical simulations of ozone from 10 climate models contributing to the Coupled Model Intercomparison Project Phase 6 (CMIP6). In addition, RF is calculated for ozone fields prepared as an input for CMIP6 models without chemistry schemes and from a chemical transport model simulation. A radiative kernel for ozone is constructed and used to derive the RF. The ozone RF in 2010 (2005–2014) relative to 1850 is 0.35 W m -2 [0.08–0.61] (5–95% uncertainty range) based on models with both tropospheric and stratospheric chemistry. One of these models has a negative present-day total ozone RF. Excluding this model, the present-day ozone RF increases to 0.39 W m -2 [0.27–0.51] (5–95% uncertainty range). The rest of the models have RF close to or stronger than the RF time series assessed by the Intergovernmental Panel on Climate Change in the fifth assessment report with the primary driver likely being the new precursor emissions used in CMIP6. The rapid adjustments beyond stratospheric temperature are estimated to be weak and thus the RF is a good measure of effective radiative forcing.

54 ENVIRONMENTAL SCIENCES↗

Proximity enhanced magnetism at NiFe 2 O 4 /Graphene interface

Here, we explore the change in effective magnetic anisotropy of the ferrimagnetic (FM) insulator nickel ferrite (NFO) thin film due to the inclusion of monolayer graphene (MLG) grown on top of the NFO layer. This was done by performing radio frequency (RF) transverse susceptibility (TS) measurements on bare NFO and NFO/MLG bilayer samples for both in-plane (IP) and out-of-plane (OOP) configurations utilizing a tunnel diode oscillator technique. Our magnetometry measurements indicated an enhancement in the overall saturation magnetization of the NFO/MLG bilayer with respect to the bare NFO film. The TS measurements reveal that the inclusion of MLG reduces the effective magnetic anisotropy for both IP and OOP configurations drastically, by up to a factor of 2 over the temperature range 40 K ≤ T ≤ 280 K. Since NFO is a magnetic substrate, it is possible that NFO could induce magnetic ordering in MLG at the NFO/MLG interface via the magnetic proximity effect. Furthermore, since NFO is insulating and MLG is a semimetal, there likely exists a large conductivity difference at the interface, making charge transfer plausible. These two effects could modify the interfacial magnetism leading to a change in the effective magnetic anisotropy. These results highlight the importance of understanding the interfacial magnetism of FM/MLG heterostructures.

36 MATERIALS SCIENCE↗

Electric field determination in transient plasmas: in situ & non-invasive methods

Abstract One of the primary basic plasma parameters within transient nonequilibrium plasmas is the reduced electric field strength, roughly understood as the ratio of the electrical energy given to the charged species between two collisions. While physical probes have historically been used for electric field measurements, recent advances in high intensity lasers and sensitive detection methods have allowed for non-invasive optical electric field determination in nearly any discharge configuration with time-resolution up to the sub-nanosecond range and sub-millimeter spatial resolution. This topical review serves to highlight several non-invasive methods for in situ electric field strength determination in transient plasmas ranging from high vacuum environments to atmospheric pressure and above. We will discuss the advantages and proper implementation of (i) laser induced fluorescence dip spectroscopy for measurements in low pressure RF discharges, (ii) optical emission spectroscopy based methods for nitrogen, helium or hydrogen containing discharges, (iii) electric field induced coherent Raman scattering, and (iv) electric field induced second harmonic generation. The physical mechanism for each method will be described as well as basic implementation and highlighting recent results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent H - ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced from spallation of liquid Hg by bombardment of short (~1 μs), intense (~35 A) pulses of protons delivered at 60 Hz by a storage ring which is fed by a high-intensity, ~1 GeV H - LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50–60 mA of H - ions with a duty-factor of 6% for maintenance-free runs of several months with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting this success: this report provides an update on some of the ongoing ion source research and development efforts which have been undertaken since the previous Negative Ion Beams and Sources (NIBS) conference in 2020. These include significant improvements to H - beam current by extraction from a larger source outlet aperture and improvements to the electron dumping system which should eliminate the gradual loss of electrode voltage over the course of a run which has occasionally impacted SNS operations. Improvement and simplification of the plasma ignition system for the external antenna ion source, a long-standing problem, was also realized. Lastly, RF coupling efficiency was measured for both the SNS internal and external antenna ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oxygen vacancies in niobium pentoxide as a source of two-level system losses in superconducting niobium

Two-level systems (TLS) have long been a catch-all explanation for RF loss and quantum decoherence in superconducting devices. In our study, the first to directly link TLS losses to a specific physical mechanism, we demonstrate that oxygen vacancies in the naturally formed Nb₂O₅ on oxidized niobium are a major driver of such dissipation. We performed sequential in situ vacuum-baking treatments on niobium superconducting radio-frequency (SRF) cavities and used time-of-flight secondary ion mass spectrometry (TOF-SIMS) to reveal a nonmonotonic evolution in cavity quality factor (Q₀). This behavior correlates with the interplay of Nb₂O₅ vacancy generation and oxide-thickness dissolution. We localize this effect to the oxide itself and present the insignificant role of diffused interstitial oxygen in the underlying Nb by regrowing the oxide via wet oxidation, revealing a mitigation of aggravated TLS losses. We hypothesize that such vacancies in the pentoxide serve as magnetic impurities and are a source of TLS-driven rf loss. Although our measurements center on 3-D SRF cavities, the insights gained here have significant implications for mitigating decoherence in 2-D superconducting qubits.

Bafia, Daniel P. [Fermilab]↗