Measurement of HOMs in the RHIC RF Cavities
The Relativistic Heavy Ion Collider (RHIC) consists of two counter rotating beams which collide at two different experiments (PHENIX at IP8 and STAR at IP6). The particles that are accelerated range from protons to gold ions and each accelerator ring has the capability to accelerate a different specie. Table 1 summarizes the main machine parameters. The RF system on both rings has to be able to capture, accelerate and store up to 120 bunches with an average total bunch intensity of 1.0 × 10 9 particles/bunch for gold ions and 2 × 10 11 for protons. In the case of heavy ions the RF system must capture the particles at injection, accelerate them through transition and transfer the bunches from the 28 MHz system to the 197 MHz system. The 28 MHz accelerating cavities operate with 300 kV before transition and 150 kV throughout the rest of the energy ramp for ions and the 197 MHz system operates with 4 MV total gap voltage. In the case of protons, since the particles are injected above transition, only acceleration and storage is needed and the 28 MHz RF cavity is used with a voltage of 300 kV while the 197 MHz system uses a much smaller voltage of 50 kV only to increase the synchrotron frequency spread and improve Landau damping.