Improvements to the internal and external antenna H{sup −} ion sources at the Spallation Neutron Source

The Spallation Neutron Source (SNS), a large scale neutron production facility, routinely operates with 30–40 mA peak current in the linac. Recent measurements have shown that our RF-driven internal antenna, Cs-enhanced, multi-cusp ion sources injects ∼55 mA of H{sup −} beam current (∼1 ms, 60 Hz) at 65-kV into a Radio Frequency Quadrupole (RFQ) accelerator through a closely coupled electrostatic Low-Energy Beam Transport system. Over the last several years a decrease in RFQ transmission and issues with internal antennas has stimulated source development at the SNS both for the internal and external antenna ion sources. This report discusses progress in improving internal antenna reliability, H{sup −} yield improvements which resulted from modifications to the outlet aperture assembly (applicable to both internal and external antenna sources) and studies made of the long standing problem of beam persistence with the external antenna source. The current status of the external antenna ion source will also be presented.

43 PARTICLE ACCELERATORS↗

Ion Source Development at the SNS

The Spallation Neutron Source (SNS) now routinely operates near 1 MW of beam power on target with a highly-persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. The {approx}1 ms-long, 60 Hz, {approx}50 mA H{sup -} beam pulses are extracted from a Cs-enhanced, multi-cusp, RF-driven, internal-antenna ion source. An electrostatic LEBT (Low Energy Beam Transport) focuses the 65 kV beam into the RFQ accelerator. The ion source and LEBT have normally a combined availability of {approx}99%. Although much progress has been made over the last years to achieve this level of availability further improvements are desirable. Failures of the internal antenna and occasionally impaired electron dump insulators require several source replacements per year. An attempt to overcome the antenna issues with an AlN external antenna source early in 2009 had to be terminated due to availability issues. This report provides a comprehensive review of the design, experimental history, status, and description of recently updated components and future plans for this ion source. The mechanical design for improved electron dump vacuum feedthroughs is also presented, which is compatible with the baseline and both external antenna ion sources.

07 ISOTOPE AND RADIATION SOURCES↗

Plasma Sputter-type Ion Source with Wire Electrodes for Low-energy Gallium Ion Extraction

Low-energy ions of gallium (Ga) and argon (Ar) were extracted from a plasma sputter-type ion source system that utilized a tungsten (W) wire extractor geometry. The 90% transparent W wire extractor configuration had shown that the system was capable of producing an ion beam with the energy as low as 10 eV in a dc filament discharge and 50 eV in a radio frequency (rf) excited system. In the present investigation, Ar plasma was sustained in an ion source chamber through an inductively coupled 13.56 MHz rf power source. Negatively biased liquid Ga target suspended on a W reservoir was sputtered and postionized prior to extraction. Mass spectral analyses revealed a strong dependence of the Ga{sup +} current on the induced target bias.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The direct injection of intense ion beams from a high field electron cyclotron resonance ion source into a radio frequency quadrupole

The ion current achievable from high intensity ECR sources for highly charged ions is limited by the high space charge. This makes classical extraction systems for the transport and subsequent matching to a radio frequency quadrupole (RFQ) accelerator less efficient. The direct plasma injection (DPI) method developed originally for the laser ion source avoids these problems and uses the combined focusing of the gap between the ion source and the RFQ vanes (or rods) and the focusing of the rf fields from the RFQ penetrating into this gap. For high performance ECR sources that use superconducting solenoids, the stray magnetic field of the source in addition to the DPI scheme provides focusing against the space charge blow-up of the beam. A combined extraction/matching system has been designed for a high performance ECR ion source injecting into an RFQ, allowing a total beam current of 10 mA from the ion source for the production of highly charged {sup 238}U{sup 40+} (1.33 mA) to be injected at an ion source voltage of 60 kV. In this design, the features of IGUN have been used to take into account the rf-focusing of an RFQ channel (without modulation), the electrostatic field between ion source extraction and the RFQ vanes, the magnetic stray field of the ECR superconducting solenoid, and the defocusing space charge of an ion beam. The stray magnetic field is shown to be critical in the case of a matched beam.

43 PARTICLE ACCELERATORS↗

Langmuir probes for SPIDER (source for the production of ions of deuterium extracted from radio frequency plasma) experiment: Tests in BATMAN (Bavarian test machine for negative ions)

A prototype system of the Langmuir probes for SPIDER (Source for the production of Ions of Deuterium Extracted from RF plasma) was manufactured and experimentally qualified. The diagnostic was operated in RF (Radio Frequency) plasmas with cesium evaporation on the BATMAN (BAvarian Test MAchine for Negative ions) test facility, which can provide plasma conditions as expected in the SPIDER source. A RF passive compensation circuit was realised to operate the Langmuir probes in RF plasmas. The sensors’ holder, designed to better simulate the bias plate conditions in SPIDER, was exposed to a severe experimental campaign in BATMAN with cesium evaporation. No detrimental effect on the diagnostic due to cesium evaporation was found during the exposure to the BATMAN plasma and in particular the insulation of the electrodes was preserved. The paper presents the system prototype, the RF compensation circuit, the acquisition system (as foreseen in SPIDER), and the results obtained during the experimental campaigns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cesium Delivery System for Negative Ion Source at IPR

The technique of surface production of negative ions using cesium, Cs, has been efficiently exploited over the years for producing negative ion beams with increased current densities from negative ion sources used on neutral beam lines. Deposition of Cs on the source walls and the plasma grid lowers the work function and therefore enables a higher yield of H{sup -}, when hydrogen particles (H and/or H{sub x}{sup +}) strike these surfaces.A single driver RF based (100 kW, 1 MHz) negative ion source test bed, ROBIN, is being set up at IPR under a technical collaboration between IPR and IPP, Germany. The optimization of the Cs oven design to be used on this facility as well as multidriver sources is underway. The characterization experiments of such a Cs delivery system with a 1 g Cs inventory have been carried out using surface ionization technique. The experiments have been carried by delivering Cs into a vacuum chamber without plasma. The linear motion of the surface ionization detector, SID, attached with a linear motion feedthrough allows measuring the angular distribution of the Cs coming out of the oven. Based on the experimental results, a Cs oven for ROBIN has been proposed. The Cs oven design and experimental results of the prototype Cs oven are reported and discussed in the paper.

43 PARTICLE ACCELERATORS↗

Experimental study of hot electrons in LECR2M plasma

In order to investigate the hot electron component in electron cyclotron resonance (ECR) plasmas, the volume bremsstrahlung spectra in the x-ray photon energy range were measured with a high-purity germanium detector on Lanzhou ECR Ion Source No. 2 Modified (LECR2M). A collimation system similar to Bernhardi's was used to focus at the central part of the plasma. The ion source was operated under various source conditions with argon; sometimes oxygen was added to enhance high charge state ion beam intensities. The spectral temperature of hot electrons T{sub spe} was derived from the measured bremsstrahlung spectra. The evolution of the deduced temperature of hot electrons T{sub spe} with the ion source parameters, such as the rf frequency, power, and the magnetic confinement configuration, was investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent H - ion source research and development at the Oak Ridge National Laboratory

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. Neutrons are produced from spallation of liquid Hg by bombardment of short (~1 μs), intense (~35 A) pulses of protons delivered at 60 Hz by a storage ring which is fed by a high-intensity, ~1 GeV H - LINAC. This facility has operated almost continuously since 2006, with ion source performance increasing over those years, and currently providing 50–60 mA of H - ions with a duty-factor of 6% for maintenance-free runs of several months with near 100% availability. Ion source research and development at ORNL has played a key role in enabling and supporting this success: this report provides an update on some of the ongoing ion source research and development efforts which have been undertaken since the previous Negative Ion Beams and Sources (NIBS) conference in 2020. These include significant improvements to H - beam current by extraction from a larger source outlet aperture and improvements to the electron dumping system which should eliminate the gradual loss of electrode voltage over the course of a run which has occasionally impacted SNS operations. Improvement and simplification of the plasma ignition system for the external antenna ion source, a long-standing problem, was also realized. Lastly, RF coupling efficiency was measured for both the SNS internal and external antenna ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulsed pyroelectric crystal-powered gamma source

A compact pulsed gamma generator is being developed to replace radiological sources used in commercial, industrial and medical applications. Mono-energetic gammas are produced in the 0.4 - 1.0 MeV energy range using nuclear reactions such as {sup 9}Be(d,n{gamma}){sup 10}B. The gamma generator employs an RF-driven inductively coupled plasma ion source to produce deuterium ion current densities up to 2 mA/mm{sup 2} and ampere-level current pulses can be attained by utilizing an array extraction grid. The extracted deuterium ions are accelerated to approximately 300 keV via a compact stacked pyroelectric crystal system and then bombard the beryllium target to generate gammas. The resulting microsecond pulse of gammas is equivalent to a radiological source with curie-level activity.

43 PARTICLE ACCELERATORS↗

Source-to-accelerator quadrupole matching section for a compact linear accelerator

Recently, we presented a new approach for a compact radio-frequency (RF) accelerator structure and demonstrated the functionality of the individual components: acceleration units and focusing elements. In this paper, we combine these units to form a working accelerator structure: a matching section between the ion source extraction grids and the RF-acceleration unit and electrostatic focusing quadrupoles between successive acceleration units. The matching section consists of six electrostatic quadrupoles (ESQs) fabricated using 3D-printing techniques. The matching section enables us to capture more beam current and to match the beam envelope to conditions for stable transport in an acceleration lattice. We present data from an integrated accelerator consisting of the source, matching section, and an ESQ doublet sandwiched between two RF-acceleration units.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Cost High Efficiency Magnetrons for Accelerator Applications

High efficiency, low cost RF sources are required for proton, ion, and muon accelerators. These sources must be compact and provide precise control of the output power and phase. Currently only large, expensive klystrons can provide this performance. Calabazas Creek Research Inc. proposes to develop a phase locked magnetron-based system that has phase and amplitude control via a low power amplifier. The system uses phase modulation to control the RF power. The efficiency can exceed 80% and the cost is expected to be less than $3/Watt, significantly lower than other high power amplifiers. CCR originally proposed to develop a magnetron with a grid for control of phase and amplitude. Detailed simulations showed that this was not a promising approach. The grid was found to be viable only in magnetrons with low duty cycle, and amplitude control was demonstrated; but the grid was found to be not effective for phase locking. Attention was turned to a concept from Fermilab, which is very promising for both amplitude and phase control and does not require a grid. CCR will develop an RF system providing phase and amplitude control of a 100 kW peak, 10 kW average 1.3 GHz magnetron. Procedures and techniques will be applicable to design of systems at other frequencies and power levels. The program will include development of the magnetron and locking electronics. The system will be tested at Fermilab. Commercial Applications and Other Benefits Magnetrons can provide high levels of RF power at very high efficiency at low cost. As oscillators, however, their applications are limited. Magnetrons with more precise control of the output power and control of the phase could find wide application in accelerators and colliders. They would also provide improved performance for high resolution radar.

43 PARTICLE ACCELERATORS↗

Impurity transport in PISCES-RF

Linear plasma devices (LPD) utilizing a helicon plasma source, a high density light ion source, can generate impurities due to progressive erosion of the radio frequency (RF) transmission window caused by rectified sheath voltage. These source-born impurities can entrain and be transported by the plasma toward a target, affecting plasma-material interaction studies. Earlier work on material testing in Prototype-Materials Plasma Exposure eXperiment at ORNL revealed significant source impurity deposition on downstream targets. However, using a similar RF source, no target impurity deposition is observed in Plasma Interaction Surface Component Experimental Station (PISCES)-RF despite evidence of RF window erosion in the source region, thereby motivating the present work. Experimentally, using various magnetic field configurations upstream of the PISCES-RF plasma source and seeding titanium (Ti) impurities at various axial locations, impurity transport and deposition along the machine axis were investigated. It was found that Ti deposition was localized to the side of the plasma source where the Ti impurity was seeded. In contrast, aluminum (Al) deposition, originating from the sputtering of the helicon window, occurred predominantly upstream of the plasma source, suggesting an asymmetry in the axial transport of eroded RF window material. These observations suggest a stagnation of the parallel plasma flow immediately downstream of the plasma source, with impurity ions remaining unmagnetized near the source upstream. Al deposition in magnetic field-free regions in PISCES-RF indicates that sputtered Al impurities likely remained neutral due to their large ionization mean-free path under PISCES-RF conditions. Plasma modeling and simulation supported this, indicating that Al-neutrals transport toward the helicon source upstream for low electron density cases. It was found that the Larmor radius of the Al ions was greater than the plasma radius towards the source upstream and remained weakly magnetized in PISCES-RF, meaning that plasma source-born impurities are not efficiently entrained in the plasma flow. These findings provide critical insights into impurity transport in helicon plasma-based LPDs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A highly miniaturized vacuum package for a trapped ion atomic clock

We report on the development of a highly miniaturized vacuum package for use in an atomic clock utilizing trapped ytterbium-171 ions. The vacuum package is approximately 1 cm{sup 3} in size and contains a linear quadrupole RF Paul ion trap, miniature neutral Yb sources, and a non-evaporable getter pump. We describe the fabrication process for making the Yb sources and assembling the vacuum package. To prepare the vacuum package for ion trapping, it was evacuated, baked at a high temperature, and then back filled with a helium buffer gas. Once appropriate vacuum conditions were achieved in the package, it was sealed with a copper pinch-off and was subsequently pumped only by the non-evaporable getter. We demonstrated ion trapping in this vacuum package and the operation of an atomic clock, stabilizing a local oscillator to the 12.6 GHz hyperfine transition of {sup 171}Y b{sup +}. The fractional frequency stability of the clock was measured to be 2 × 10{sup −11}/τ{sup 1/2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Suppression of unimolecular decay of laser desorbed peptide and protein ions by entrainment in rarefied supersonic gas jets under weak electric fields

Unimolecular decay of sample ions imposes a limit on the usable laser fluence in matrix-assisted laser desorption/ionization (MALDI) ion sources. Traditionally, some modest degree of collisional sample ion cooling has been achieved by connecting MALDI ion sources directly to gas-filled radio frequency (RF) multipoles. It was also discovered in the early 1990s that gas-filled RF multipoles exhibit increased ion transmission efficiency due to collisional ion focusing effects. This unexpected experimental finding was later supported by elementary Monte Carlo simulations. Both experiments and simulations assumed a resting background gas with typical pressures of the order of 1 Pa. However, considerable additional improvements can be achieved if laser desorbed sample ions are introduced immediately after desorption, still within the ion source, in an axisymmetric rarefied supersonic gas jet with peak pressure of the order of 100 Pa and flow velocities >300 m/s, and under weak electric fields. We describe here the design principle and report performance data of an ion source coined “MALDI-2,” which incorporates elements of both rarefied aerodynamics and particle optics. Such a design allows superb suppression of metastable fragmentation due to rapid collisional cooling in <10 μs and nearly perfect injection efficiency into the attached RF ion guide, as numerous experiments have confirmed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding carbon sourcing and transport originating from the helicon antenna surfaces during high-power helicon discharge in DIII-D Tokamak

The high-power helicon wave system in the DIII-D tokamak could potentially introduce new plasma–material interaction (PMI) challenges owing to rectified RF sheath potentials that develop near the antenna and surrounding plasma-facing components. We present the first application of the STRIPE (Simulated Transport of RF Impurity Production and Emission) framework to helicon-induced PMIs, extending previous STRIPE studies of ICRH antennas by incorporating net erosion, local re-deposition, and three-dimensional global impurity transport. The integrated workflow couples SOLPS, COMSOL, RustBCA, GITR, and GITRm to simulate carbon erosion, re-deposition, and impurity transport for two experimentally constrained DIII-D H-mode helicon operating scenarios with different antenna–plasma gaps, coupled RF powers, and edge plasma conditions. COMSOL predicts rectified RF sheath potentials of 1–5 kV localized near the lower portion of the antenna, where the magnetic field intersects the surface at grazing incidence. Carbon self-sputtering dominates the erosion source, whereas RF-accelerated D + ions contribute approximately 1% of the total gross erosion. The smaller-gap operating scenario exhibits substantially stronger gross erosion, enhanced local re-deposition (∼12%), and a larger confined carbon inventory owing to increased plasma accessibility and broader RF sheath coverage. Comparison with available DIII-D measurements shows no distinct change in the global carbon signal that correlates with the helicon RF pulse, consistent with the simulations indicating that the helicon-generated carbon source remains small compared with the existing background carbon inventory under the present graphite-wall operating conditions. These results demonstrate the capability of STRIPE to integrate RF sheath modeling, plasma transport, surface interaction physics, and three-dimensional impurity transport for the interpretation of helicon-induced PMIs. The study further identifies the principal sources of modeling uncertainty, including grazing-angle RF sheath physics, slow-wave resolution, plasma-background extrapolation, and trace-impurity transport assumptions, providing a framework for future validation and model development.

Kumar, Atul [Oak Ridge National Laboratory (ORNL),↗

H{sup -} radio frequency source development at the Spallation Neutron Source

The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. H{sup -} beam pulses ({approx}1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, {approx}60 kW) of a copper antenna that has been encased with a thickness of {approx}0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of {approx}99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of {approx}75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance/installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to {approx}100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence.

43 PARTICLE ACCELERATORS↗

A look ahead: Status of the SNS external antenna ion source and the new RFQ test stand

The U.S. Spallation Neutron Source (SNS) now operates with ∼1 MW of beam power to target with the near-term goal of delivering 1.4 MW. Plans are being considered to incorporate a second target station into the facility which will require ∼2.8 MW of beam power. Presently, H{sup −} beam pulses (∼1 ms, 60 Hz) are produced by an RF-driven, Cs-enhanced, multi-cusp ion source which injects beam into an RFQ (Radio Frequency Quadrupole) accelerator that, in turn, feeds the SNS Linac. Currently the source/RFQ system delivers ∼35 mA of pulsed current to the linac which is mostly sufficient for 1.4 MW operations while ∼50 mA are needed for the second target station upgrade. This paper provides a look forward for the SNS by providing (i) the present and future SNS source/RFQ beam requirements and our plans to achieve these, (ii) a description and status of the external antenna ion source being developed for the replacement of the current internal antenna ion source, and (iii) a description and status of the newly constructed RFQ test facility.

43 PARTICLE ACCELERATORS↗

Design of a versatile multiaperture negative ion source

Negative ion sources are a key component of the neutral beam injector to be installed in the International Thermonuclear Experimental Reactor. At present research and development activities address several important issues related to beam extraction, optics, and optimization. Together with the design of real size devices and the accumulation of atomic cross section databases, a relatively small negative ion source [130 mA of H{sup -} at 60 kV, named Negative Ion Optimization phase 1 (NIO1)] is under construction at Consorzio RFX to contribute to benchmark numerical simulation tools and to test components, such as emittance scanners, beam dumps, and cesium ovens. NIO1 design, magnet configuration, and rf coupling simulations are described.