Search NASA⌕ Search

SEARCH · Search NASA

Results for “ROTATING CYLINDER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The Effect of Rotating a Faraday Disc Perpendicular to an Applied Magnetic Field Theory and Experiment

A magnetohydrodynamic model that examines the effect of rotating an electrically conducting cylinder with a uniform external magnetic field applied orthogonal to its axis is presented. Noting a simple geometry, it can be classified as a fundamental dynamo problem. For the case of an infinitely long cylinder, an analytical solution is obtained and analyzed in detail. A semi-analytical model was developed that considers a finite cylinder. Experimental data from a spinning brass wheel in the presence of Earth's magnetic field were compared to the proposed theory and found to fit well.

Mazuruk, Konstantin↗

Rotating Reverse-Osmosis for Water Purification

A new design for a water-filtering device combines rotating filtration with reverse osmosis to create a rotating reverse- osmosis system. Rotating filtration has been used for separating plasma from whole blood, while reverse osmosis has been used in purification of water and in some chemical processes. Reverse- osmosis membranes are vulnerable to concentration polarization a type of fouling in which the chemicals meant not to pass through the reverse-osmosis membranes accumulate very near the surfaces of the membranes. The combination of rotating filtration and reverse osmosis is intended to prevent concentration polarization and thereby increase the desired flux of filtered water while decreasing the likelihood of passage of undesired chemical species through the filter. Devices based on this concept could be useful in a variety of commercial applications, including purification and desalination of drinking water, purification of pharmaceutical process water, treatment of household and industrial wastewater, and treatment of industrial process water. A rotating filter consists of a cylindrical porous microfilter rotating within a stationary concentric cylindrical outer shell (see figure). The aqueous suspension enters one end of the annulus between the inner and outer cylinders. Filtrate passes through the rotating cylindrical microfilter and is removed via a hollow shaft. The concentrated suspension is removed at the end of the annulus opposite the end where the suspension entered.

Lueptow, RIchard M.↗

Rotary plant growth accelerating apparatus

Rotary plant growth accelerating apparatus for increasing plant yields by effectively removing the growing plants from the constraints of gravity and increasing the plant yield per unit of space is described. The apparatus is comprised of cylindrical plant beds supported radially removed from a primary axis of rotation, with each plant bed being driven about its own secondary axis of rotation and simultaneously moved in a planetary path about the primary axis of rotation. Each plant bed is formed by an apertured outer cylinder, a perforated inner cylinder positioned coaxially, and rooting media disposed in the space between. A rotatable manifold distributes liquid nutrients and water to the rooting media through the perforations in the inner cylinders as the plant beds are continuously rotated by suitable drive means.

Dedolph, R. D.↗

Viscous effects in rapidly rotating stars with application to white-dwarf models. I, II.

A general approximate numerical technique is proposed for constructing evolutionary sequences of rapidly rotating axisymmetric barytropic equilibrium configurations, with allowance for angular momentum transfer by a nonconstant isotropic viscosity. The principal physical assumption involved is the constancy of the angular momentum per unit mass on cylinders about the axis of rotation. Rapidly rotating nonmagnetic white-dwarf models with a zero-temperature degenerate-electron equation of state are considered as a particular application. The viscosity used in the analysis is that of the degenerate electrons.

Durisen, R. H.↗

The fluid dynamic and shear environment in the NASA/JSC rotating-wall perfused-vessel bioreactor

The rotating-wall perfused-vessel (RWPV) bioreactor, used for both microgravity and Earth-based cell science experiments, is characterized in terms of the fluid dynamic and fluid shear stress environment. A numerical model of the flow field is developed and verified with laser Doppler velocimeter measurements. The effects of changes in operating conditions, including rotation rates and fluid perfusion rates, are investigated with the numerical model. The operating conditions typically used for ground-based experiments (equal rotation of the inner and outer cylinders) leads to flow patterns with relatively poor mass distribution characteristics. Approximately 50% of the inlet-perfused fluid bypasses the bulk of the fluid volume and flows to the perfusion exit. For operating conditions typical in microgravity, small differential rotation rates between the inner and outer cylinders lead to greatly improved flow distribution patterns and very low fluid shear stress levels over a large percentage of the fluid volume. Differences in flow patterns for the different operating conditions are explored. Large differences in the hydrodynamic environments for operating conditions typical of true microgravity and ground-based "microgravity simulations" are demonstrated.

Bioreactors↗

A multipurpose satellite ejection system

A design is presented for a pneumatic ejection system capable of ejecting a spin stabilized satellite from the cargo bay of space vehicles. This system was orginally designed for use on the Spacelab 6 shuttle mission, but is now being considered for use with expendable rockets for launching satellites. The ejection system was designed to launch a 150 lb satellite at an initial ejection velocity of 32 ft/sec with a spin rate of 30 rev/min. The ejection system consists of a pneumatic cylinder, satellite retaining mechanism, and bearing assembly to allow the satellite to rotate during the spin up phase. As the cylinder is pressurized rapidly causing movement of the actuation piston, the mechanism automatically releases the spinning satellite by retracting a pneumatic locking pin and three spring loaded holddown pins. When the piston reaches the end of its stroke, it encounters a crushable aluminum honeycomb shock absorber which decelerates the piston and retaining mechanism. The assembly is designed for multiple uses except for the crushable shock absorber and pyrotechnic valves. The advantage of the design is discussed and patent no. and date given.

Moore, Michael B.↗

Taylor–Couette flow for astrophysical purposes

A concise review is given of astrophysically motivated experimental and theoretical research on Taylor–Couette flow. The flows of interest rotate differentially with the inner cylinder faster than the outer, but are linearly stable against Rayleigh’s inviscid centrifugal instability. At shear Reynolds numbers as large as 10 6 , hydrodynamic flows of this type (quasi-Keplerian) appear to be nonlinearly stable: no turbulence is seen that cannot be attributed to interaction with the axial boundaries, rather than the radial shear itself. Direct numerical simulations agree, although they cannot yet reach such high Reynolds numbers. This result indicates that accretion-disc turbulence is not purely hydrodynamic in origin, at least insofar as it is driven by radial shear. Theory, however, predicts linear magnetohydrodynamic (MHD) instabilities in astrophysical discs: in particular, the standard magnetorotational instability (SMRI). MHD Taylor–Couette experiments aimed at SMRI are challenged by the low magnetic Prandtl numbers of liquid metals. High fluid Reynolds numbers and careful control of the axial boundaries are required. The quest for laboratory SMRI has been rewarded with the discovery of some interesting inductionless cousins of SMRI, and with the recently reported success in demonstrating SMRI itself using conducting axial boundaries. Some outstanding questions and near-future prospects are discussed, especially in connection with astrophysics.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamic-reservoir lubricating device

Dynamic-reservoir lubricating device supplies controlled amounts of lubricating oil to ball bearings during operation of the bearings. The dynamic reservoir lubricating device includes a rotating reservoir nut, a hollow cylinder filled with lubricating oil, flow restrictors and a ball bearing retainer.

Ficken, W. H.↗

Free Body Dynamics of a Spinning Cylinder with Planar Restraint-(a.k.a. Barrel of Fun)

The dynamic motion of a cylinder is analyzed based on rotation about its center of mass and is restrained by a plane normal to the axis passing through its center of mass at an angle. The first part of this work presented an analysis of the stability of the motion. In the current report, the governing equations are numerically integrated in time and the steady state is obtained as a limit of the transient numerical solution. The calculated data are compared with observed behaviors.

Moraru, Laurentiu↗

Steady simple shear flow past a circular cylinder at moderate Reynolds numbers - A numerical solution

The two-dimensional steady flow of an incompressible viscous fluid past a circular cylinder, placed symmetrically in a simple shear field, has been studied for both the stationary and the freely rotating case by solving numerically the Navier-Stokes equations for values of the Reynolds number R in the range from 0.047 to 70. At R = 0.047, the results obtained are in substantial agreement with the analytic small-R perturbation solution given by Robertson and Acrivos (1970). Inertia effects were found, however, to play a significant role even at R = 1, and hence the calculated flow pattern for R greater than or equal to 1 differs significantly from that of the creeping-flow solution. Specifically, for the freely rotating case, the region of closed streamlines decreases rapidly in extent with increasing R, two symmetrically placed wakes are formed on either side of the cylinder, and the dimensionless rotational speed of the freely suspended cylinder decreases as the reciprocal of the square root of R.

Kossack, C. A.↗

Linear stability of compressible Taylor-Couette flow

A temporal stability analysis of compressible Taylor-Couette flow is presented. The viscous flow studied in this paper is contained between two concentric cylinders of infinite length, which are rotating with different angular velocities and are kept at different surface temperatures. The effects of differential rotation and temperature difference on the stability of Taylor-Couette flow are contrasted for a range of Mach numbers ranging from incompressible to Mach 3.0. The relative motion of the cylinders dramatically affects the characteristics of the Couette flow at the onset of instability. The flow is stabilized or destabilized depending upon the temperature ratio and speeds of the two cylinders. Independent of Mach number and temperature ratio, increasing Reynolds number generally promotes a destabilizing effect, indicating the inviscid nature of the Taylor-Couette flow.

Kao, Kai-Hsiung↗

Time-Varying Entry Heating Profile Replication with a Rotating Arc Jet Test Article

A new approach to arc jet testing that replicates the time-varying conditions of atmospheric entry heating was demonstrated. The concept relies on the spatial variation of heat flux and pressure around a cylindrical test article. The spatial variation is transformed to a temporal variation at one location by rotating the test article during exposure to the arc jet stream. The test article rotation mechanism is based on a programmable stepper motor. An entry heat flux profile was mapped to the cylinders heat flux distribution to determine the rotation angle vs. time executed by the mechanism. A series of arc jet tests with instrumented cylindrical TPS test articles was conducted to prove the concept.

Aerothermodynamics↗

Dual mode actuator

Compact mechanism functions under automatic control, manual control, or both. Output shaft rotation is controlled automatically by two hydraulic cylinders or manually by movement of input lever. Automatic control movement is isolated from manual-control movement by adjustment of force on piston spring. Actuator can be modified to control straight line position rather than rotation, or to open valves that regulate fluid flow in actuator, thus creating special movements other than simple rotation.

Rick, S. C.↗

Finite-difference multiple fluid solution for source-driven rotation in highly magnetized linear plasma device

The rotation profile of a magnetized plasma cylinder composed of multiple fluids is investigated analytically, expanding on previous results. The analytic steady-state solution is used as a benchmark for a time-dependent multiple-fluid finite-difference code, MITNS: Multiple-Ion Transport Numerical Solver. Magnetic field evolution is taken into account, both analytically and numerically. Its details are shown to be of importance when particles are allowed out of the domain. MITNS reproduces the asymptotic expansion results for a small parameter $δ<<<1$. For $\sqrt{m_elm_i} ~ δ << 1$ , a slightly different regime, dominated by viscosity-induced transport of ions, is found numerically and analytically. Finally, this verification supports the use of this code for more complex time-dependent calculations in the future. Additionally, we derive the angular velocity profile of each species due to radial particle and charge fluxes of various strengths.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Torus geometry eigenfunctions of an interacting multi-Landau-level Hamiltonian

A short-ranged, rotationally symmetric multi-Landau-level model Hamiltonian for strongly interacting electrons in a magnetic field was proposed [A. Anand et al., Phys. Rev. Lett. 126, 136601 (2021)] with the key feature that it allows exact many-body eigenfunctions on the disk not just for quasiholes but for all charged and neutral excitations of the entire Jain sequence filling fractions. We extend this to geometries without full rotational symmetry, namely, the torus and cylinder geometries, and present their spectra. Exact diagonalization of the interaction on the torus produces the low-energy spectra at filling fraction v = n/(2⁢pn + 1) that is identical, up to a topological (2⁢pn + 1)-fold multiplicity, to that of the integer quantum Hall spectra at v = n, for the incompressible state as well as all excitations. While the ansatz eigenfunctions in the disk geometry cannot be generalized to closed geometries such as torus or sphere, we show how to extend them to cylinder geometry. Meanwhile, we show eigenfunctions for charged excitations at filling fractions between 1/3 and 2/5 can be written on the torus and the spherical geometries.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Aerodynamic effects of nearly uniform slipstreams on thin wings in the transonic regime

A simplified model is used to describe the interaction between a propeller slipstream and a wing in the transonic regime. The undisturbed slipstream boundary is assumed to coincide with an infinite circular cylinder. The undisturbed slipstream velocity is rotational and is a function of the radius only. In general, the velocity perturbation caused by introducing a wing into the slipstream is also rotational. By making small disturbance assumptions, however, the perturbation velocity becomes nearly potential, and an approximation for the flow is obtained by solving a potential equation.

Rizk, M. H.↗

Ignition of metals and alloys in gaseous oxygen by frictional heating

The ignition of metals and alloys have been investigated by rotating the end of a hollow cylinder against an identical stationary cylinder on a common axis (frictional heating) in gaseous oxygen. A ranking criterion that measures the resistance of metals and alloys to ignition is discussed. It consists of the power per unit area required for ignition conveniently expressed as the product of contact pressure P and average linear velocity ALV. Data are presented that demonstrate that materials that are high in nickel and copper require greater P-ALV products for ignition (more resistant to ignition) than materials that are high in iron. Aluminum and titanium alloys are shown to require the lowest P-ALV products for ignition. The effects of varying surface velocity, contact pressure, coefficient of friction, and oxygen pressure on P-ALV products required for ignition are discussed. The results indicate that P-ALV product required for ignition increases as surface velocity increases, as contact pressure decreases, and as the coefficient of friction decreases. Increasing oxygen pressure will cause the P-ALV product required for ignition to decrease at low pressures and increase at high pressures. In some cases, the relative ranking of materials based on P-ALV products will also change as conditions are varied. The data presented in this paper are from a development program to determine the merits of using such a dynamic test method for ranking materials for oxygen service. The results to date have indicated that more testing is required before this method can be made into a standard test. The data presented do show some of the major parameters affecting the ignition of materials when exposed to frictional heating. The repeatability of the data at any set of conditions have not been thoroughly investigated.

Benz, F. J.↗

Measuring Pressure Has a New Standard

The Force-Balanced Piston Gauge (FPG) tests and calibrates instrumentation operating in the low pressure range. The system provides a traceable, primary calibration standard for measuring pressures in the range of near 0 to 15 kPa (2.2 psi) in both gauge and absolute measurement modes. The hardware combines a large area piston-cylinder with a load cell measuring the force resulting from pressures across the piston. The mass of the piston can be tared out, allowing measurement to start from zero. A pressure higher than the measured pressure, which keeps the piston centered, lubricates an innovative conical gap located between the piston and the cylinder, eliminating the need for piston rotation. A pressure controller based on the control of low gas flow automates the pressure control. DHI markets the FPG as an automated primary standard for very low-gauge and absolute pressures. DHI is selling the FPG to high-end metrology laboratories on a case by case basis, with a full commercial release to follow.

Source record↗