Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Damage Calculation Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

SU-E-T-47: Application of the Repair-Misrepair-Fixation RBE Model to Describe the Results of High Resolution Proton Irradiation Cell Survival Experiments

Purpose: To develop a system to rapidly and accurately calculate RBE with the repair-misrepair-fixation (RMF) model for proton therapy data sets and to evaluate its effectiveness in modeling RBE for cell survival experiments performed with the H460 cell line for a range of proton LET. Methods: A system for using the Monte Carlo Damage Simulation (MCDS) software with high performance computing was developed. Input for the MCDS software for a range of proton energies in increments of 0.1 MeV was generated and simulated. The output data were then used to determine doseaveraged quantities for the RMF model based on equivalently binned proton energy spectra. The method was applied to calculate RBE at 50% survival for experimental cell survival data. Experimental data were obtained using a system which allowed for the accumulation of cell survival data at known values of dose-averaged proton LETs at a range of doses. RBE was calculated based directly on a Cs-137 reference experiment and, additionally, according to fitted values of the θ and κ terms of the RMF model. Results: Dose-averaged RMF model quantities were calculated using the HPC system. Compared to experimental RBE determined using a Cs-137 irradiation as a reference, the RBE from the model differed by at most 49%. RBE based on the fitted values of θ and κ differed by at most 18% for the highest LET. Conclusion: A system for rapidly generating data necessary to calculate RBE with the RMF model has been developed. For the H460 cell line, the RMF model could not reproduce the experimentally determined RBE based solely on the photon reference data. Fitting of the θ and κ terms of the RMF model indicates that their values increase for proton LET exceeding approximately 10 keV/µm. NIH Program Project Grant P01CA021239.

60 APPLIED LIFE SCIENCES↗

A modified hypoxia-based TCP model to investigate the clinical outcome of stereotactic hypofractionated regimes for early stage non-small-cell lung cancer (NSCLC)

Purpose: Stereotactic body radiotherapy (SBRT) has been applied to lung tumors at different stages and sizes with good local tumor control (LC) rates. The linear quadratic model (LQM), in its basic formulation, does not seem to be appropriate to describe the response to radiotherapy for clinical trials, based on a few fractions. Thus, the main aim of this work was to develop a model, which takes into account the hypoxic cells and their reoxygenation. Methods: A parameter named B has been introduced in a modified tumor control probability (TCP) from LQM and linear-quadratic-linear model (LQLM), and represents the fraction of hypoxic cells that survive and become oxygenated after each irradiation. Based on published trials evaluating LC at 3 yr (LC3), values of B were obtained by maximum likelihood minimization between predicted TCP and clinical LC3. Two oxygen enhancement ratio (OER) parameter sets (1 and 2) from literature have been adopted to calculate the B-factors. Initial hypoxic cell fractions ({eta}{sub h}) from 0.05 to 0.50 were assumed. Log-likelihood (L) and Akaike information criterion (AIC) were determined in an independent clinical validation dataset. Results: The B-values of modified TCPs spanned the whole interval from 0 to 1, depending on the fractionation scheme (number of fractions and dose/fraction), showing a maximum (close to 1) at doses/fraction of 8-12 Gy. The B-values calculated using the OER parameter set 1 exhibited a smoother falloff than set 2. An analytical expression was derived to describe the B-value's dependence on the fractionation scheme. The R{sup 2}-adjusted values varied from 0.63 to 0.67 for LQ models and OER set 1 and from 0.75 to 0.78 for LQ model and OER set 2. Lower values of R{sup 2}-adjusted were found for LQLM and both OER sets. L and AIC, calculated using a fraction of {eta}{sub h} = 0.15 and the B-value from the authors analytical expression were higher than for other {eta}{sub h}-values, irrespective of model or OER set. Conclusions: The authors model allows to predict the clinical outcome associated with SBRT treatment, taking into account both direct killing and indirect vasculature or stromal damage.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radioactive Waste Water Treatment for Fukushima Daiichi Nuclear Power Plant - 16081

The Great East Japan Earthquake of 11 March 2011 caused serious damage to the Fukushima Daiichi Nuclear Power Station (NPS) of the Tokyo Electric Power Company, Inc.. Toshiba and Shaw/AVANTech installed a Simplified Active Water Retrieve and Recovery System (SARRY{sup TM}) to remove radioactive cesium (Cs) from the contaminated water. Toshiba, in partnership with EnergySolutions, also developed and installed the Multi Radionuclide Removal System (MRRSTM), which can remove radioactive nuclides being treated, except tritium, to a level less than the concentration limit in water. As contaminated water treatment has progressed, the composition of the contaminated water has changed. Both salinity and radioactive Cs concentration in the contaminated water have been decreasing. Thus, a new adsorbent that is suitable for the present water chemistry conditions is required. In order to provide an appropriate contaminated-water treatment system, Toshiba has been examining the removal of not only radioactive Cs but also radioactive strontium (Sr) by SARRY{sup TM}. SARRY{sup TM} has been operated for removing Cs by using a Cs adsorbent. Instead of a Cs adsorbent, a new media that has high selectivity for both Cs and Sr should be installed. This paper describes the results obtained when using the newly developed adsorbent for removing Cs and Sr at once. As the Cs and Sr adsorbent, we have selected crystalline silico-titanate (CST). The distribution coefficient (K{sub d}) of CST was determined by the batch method. The lifetime of the adsorbent was evaluated by a column examination. The selected CST had a K{sub d} value of over 10{sup 4} ml/g for both Cs and Sr. The highest-selectivity CST had a lifetime (defined as the period for the outlet concentration to decrease to one tenth of the inlet level) of more than 125000 BV (bed volume) for Cs and more than 18000 BV for Sr, when the test was conducted at 10 BV/h. Calculation code was also developed for estimating the relation between the BV and the decontamination factor (DF) using an adsorption rate model for diffusion and adsorption. The calculation results of the Cs and Sr adsorption behavior agreed well with the experimental results. To evaluate the replacement cycle of adsorption tower in actual equipment, the radiation exposure during the replacement operation and the required Cs and Sr removal performance were used as limiting conditions for the estimation. The results of the evaluation showed that the selected CST has sufficient performance for practical usage. Based on this finding, Toshiba proposed loading the CST in SARRY{sup TM}, and SARRY{sup TM} loaded with this CST started removing Cs and Sr in December 2014 resulting in decreased contaminated water. It has been continuously working since then. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GCR Transport in the Brain: Assessment of Self-Shielding, Columnar Damage, and Nuclear Reactions on Cell Inactivation Rates

Radiation shield design is driven by the need to limit radiation risks while optimizing risk reduction with launch mass/expense penalties. Both limitation and optimization objectives require the development of accurate and complete means for evaluating the effectiveness of various shield materials and body-self shielding. For galactic cosmic rays (GCR), biophysical response models indicate that track structure effects lead to substantially different assessments of shielding effectiveness relative to assessments based on LET-dependent quality factors. Methods for assessing risk to the central nervous system (CNS) from heavy ions are poorly understood at this time. High-energy and charge (HZE) ion can produce tissue events resulting in damage to clusters of cells in a columnar fashion, especially for stopping heavy ions. Grahn (1973) and Todd (1986) have discussed a microlesion concept or model of stochastic tissue events in analyzing damage from HZE's. Some tissues, including the CNS, maybe sensitive to microlesion's or stochastic tissue events in a manner not illuminated by either conventional dosimetry or fluence-based risk factors. HZE ions may also produce important lateral damage to adjacent cells. Fluences of high-energy proton and alpha particles in the GCR are many times higher than HZE ions. Behind spacecraft and body self-shielding the ratio of protons, alpha particles, and neutrons to HZE ions increases several-fold from free-space values. Models of GCR damage behind shielding have placed large concern on the role of target fragments produced from tissue atoms. The self-shielding of the brain reduces the number of heavy ions reaching the interior regions by a large amount and the remaining light particle environment (protons, neutrons, deuterons. and alpha particles) may be the greatest concern. Tracks of high-energy proton produce nuclear reactions in tissue, which can deposit doses of more than 1 Gv within 5 - 10 cell layers. Information on rates of cell killing from GCR, including patterns of cell killing from single particle tracks. can provide useful information on expected differences between proton and HZE tracks and clinical experiences with photon irradiation. To model effects on cells in the brain, it is important that transport models accurately describe changes in the GCR due to interactions in the cranium and proximate tissues. We describe calculations of the attenuated GCR particle fluxes at three dose-points in the brain and associated patterns of cell killing using biophysical models. The effects of the brain self-shielding and bone-tissue interface of the skull in modulating the GCR environment are considered. For each brain dose-point, the mass distribution in the surrounding 4(pi) solid angle is characterized using the CAM model to trace 512 rays. The CAM model describes the self-shielding by converting the tissue distribution to mass-equivalent aluminum, and nominal values of spacecraft shielding is considered. Particle transport is performed with the proton, neutron, and heavy-ion transport code HZETRN with the nuclear fragmentation model QMSFRG. The distribution of cells killed along the path of individual GCR ions is modeled using in vitro cell inactivation data for cells with varying sensitivity. Monte Carlo simulations of arrays of inactivated cells are considered for protons and heavy ions and used to describe the absolute number of cell killing events of various magnitude in the brain from the GCR. Included are simulations of positions of inactivated cells from stopping heavy ions and nuclear stars produced by high-energy ions most importantly, protons and neutrons.

Shavers, M. R.↗

Green synthesis and characterization of nontoxic L-methionine capped silver and gold nanoparticles

The simple green method for synthesis of stable L-Methionine (L-Met) capped silver (Ag@LM NPs) and gold (Au@LM NPs) nanoparticles (NPs) without adding any additional reduction agent or stabilizer was developed. Colloidal dispersions were characterized by UV–Vis spectrophotometry. The size and spherical shape of NPs were evaluated by transmission electron microscopy. Their surface covering was confirmed by atomic force microscopy, Fourier transform infrared spectroscopy, dynamic light scattering, and zeta potential measurements. Density functional theory calculations pointed that the preferential adsorption mode of L-Met on both Ag and Au surfaces was a vertical binding geometry via –NH2 group, while horizontal binding mode via [sbnd]S[sbnd] and –NH2 groups is also possible. The genotoxicity (evaluated by the micronucleus assay) of NPs, as well as their effects on some oxidative stress parameters (catalase activity, malondialdehyde level), were assessed in vitro using human peripheral blood cells as a model system. The influence of NPs on the morphology of lymphocyte cells studied using atomic force microscopy revealed that the membrane of cells remained unaffected after the treatment with NPs. When considering the effects of NPs on catalase activity and malondialdehyde level, neither particle type promoted oxidative stress. However, the treatment of lymphocytes with Ag@LM NPs induced a concentration-dependent enhancement of the micronuclei incidence and suppression of the cell proliferation while Au@LM NPs promoted cell proliferation, with no significant effects on micronuclei formation. The Ag@LM NPs were more prone to induce DNA damage than Au@LM NPs, which makes the latter type more suitable for further studies in nano-medicine. © 2019.

60 APPLIED LIFE SCIENCES↗

Correlation between energy deposition and molecular damage from Auger electrons: A case study of ultra-low energy (5–18 eV) electron interactions with DNA

Purpose: The present study introduces a new method to establish a direct correlation between biologically related physical parameters (i.e., stopping and damaging cross sections, respectively) for an Auger-electron emitting radionuclide decaying within a target molecule (e.g., DNA), so as to evaluate the efficacy of the radionuclide at the molecular level. These parameters can be applied to the dosimetry of Auger electrons and the quantification of their biological effects, which are the main criteria to assess the therapeutic efficacy of Auger-electron emitting radionuclides. Methods: Absorbed dose and stopping cross section for the Auger electrons of 5–18 eV emitted by{sup 125}I within DNA were determined by developing a nanodosimetric model. The molecular damages induced by these Auger electrons were investigated by measuring damaging cross section, including that for the formation of DNA single- and double-strand breaks. Nanoscale films of pure plasmid DNA were prepared via the freeze-drying technique and subsequently irradiated with low-energy electrons at various fluences. The damaging cross sections were determined by employing a molecular survival model to the measured exposure–response curves for induction of DNA strand breaks. Results: For a single decay of{sup 125}I within DNA, the Auger electrons of 5–18 eV deposit the energies of 12.1 and 9.1 eV within a 4.2-nm{sup 3} volume of a hydrated or dry DNA, which results in the absorbed doses of 270 and 210 kGy, respectively. DNA bases have a major contribution to the deposited energies. Ten-electronvolt and high linear energy transfer 100-eV electrons have a similar cross section for the formation of DNA double-strand break, while 100-eV electrons are twice as efficient as 10 eV in the induction of single-strand break. Conclusions: Ultra-low-energy electrons (<18 eV) substantially contribute to the absorbed dose and to the molecular damage from Auger-electron emitting radionuclides; hence, they should be considered in the dosimetry calculation of such radionuclides. Moreover, absorbed dose is not an appropriate physical parameter for nanodosimetry. Instead, stopping cross section, which describes the probability of energy deposition in a target molecule can be an appropriate nanodosimetric parameter. The stopping cross section is correlated with a damaging cross section (e.g., cross section for the double-strand break formation) to quantify the number of each specific lesion in a target molecule for each nuclear decay of a single Auger-electron emitting radionuclide.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Measurement of the Stopping Power of Water for Carbon Ions Using Inverted Doppler Shift Attenuation

Carbon ion therapy has gained importance in cancer treatment due to its locally well confined dose distribution, but there is a significant lack of experimental data which is needed for dose calculations and estimation of biological damage. Since tissue is mainly comprised of water, the energy-dependent stopping power of water is the critical measure. Importantly, previous data gathered from experiments with light ions has been limited to water vapour and ice and neglected water in its liquid phase. Additionally, theoretical models regarding the stopping power cannot yet describe the complex charge transfer interactions of the projectile at velocities in the range of the mean velocity of the valence electrons of the traversed medium. There are also discrepancies in the amount of phase effects concerning water and water vapour cross sections. Despite its importance there exists no experimental data for the stopping power of water for carbon ions in the energy region between 1 MeV and 5 MeV. This may be due to the short track length of carbon ions which makes traditional transmission experiments unfeasible. Therefore a project was launched to measure the stopping power of liquid water for carbon ions in the vicinity of the Bragg peak which corresponds to the energy regime of the maximum stopping power. For this measurement the inverted Doppler shift attenuation method was used. This uses the gamma quanta emitted from excited carbon nuclei which are produced by means of the {sup 12}C(α,α'){sup 12}C* reaction. The recorded γ-spectra contain the information of the projectiles velocity at the time they decay to their ground state and an internal clock provided by the exponential decay law. The deceleration of the projectile is directly connected to the stopping power which can be determined with this method as a function of the projectiles kinetic energy. Further measurements have been carried out to improve the experimental method. The setup and the preliminary results of this study will be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Field Dependence of Magnetotransport Properties of MgB{sub 2}/CrO{sub 2} Bilayer Thin Films

In this work, we comparatively investigated two MgB{sub 2} films: one (F1) was typically fabricated using the PLD method, while the other (F2) was fabricated using the same method but on top of a 100-nm-thick CrO{sub 2} layer. Both films had a thickness of 300 nm and were annealed ex situ at 700 °C for 30 min before being investigated under an external magnetic field of up to ± 7 T. The activation energy (U{sub o}), upper critical field (H{sub C2}), irreversibility field (H{sub irr}), magnetoresistance (MR), and I-V characteristics for the two films were studied in detail, and the results were compared with theoretical models. XRD analysis showed that both films are c-axis-oriented, while the RRR values for the films were found to be 1.6 and 1.89, respectively. Experimental data showed a broadening of the R-T transitions for an increasing magnetic field, with such broadening observed to be wider for F2 due to surface superconductivity. The activation energy under magnetic fields ranging from 0 to 7 T was calculated using our data and compared with a theoretical model. In both films, U{sub o} followed a parabolic curve but was higher for F2 up to 6 T before sharply decreasing, while it continued to follow the same trend for F1 up to 7 T. The theoretical model was in good agreement with F1 for the full span of magnetic fields used. H{sub C2} and H{sub irr} were estimated and fitted using Ginzburg–Landau theory, but although the fitting was very good for F1, some modification in fitting parameters was required to obtain the same fitting for F2. Magnetoresistance and I-V characteristics confirm that the CrO{sub 2} layer in F2 leads to faster damage to the superconductivity property for high magnetic fields and temperatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microchemical and Structural Evidence for Space Weathering in Soils from Asteroid Itokawa

The chemistry, microstructure and optical properties of grains on the surfaces of airless bodies are continu-ously modified due to their interactions predominantly with solar energetic ions and micrometeorite impacts. Collectively known as space weathering, this phenomenon results in a discrepancy between remotely sensed spectra from asteroids and those ac-quired directly from meteorites. The return of pristine samples from the asteroid Itokawa provides insight into surface processes on airless bodies and will help in correlating remote sensing data with laboratory analysis of meteorites. Samples and Methods: We examined Itokawa samples RA-QD02-0042-01 and RA-QD-02-0042-02, ultramicrotomed sec-tions of a singular grain prepared by the Hayabusa sample cura-tion team. We analyzed these slices using a 200 keV JEOL 2010F transmission electron microscope (TEM) at Arizona State Uni-versity and a 200 keV JEOL 2500SE TEM at NASA JSC. Both field emission TEMs are equipped with energy-dispersive X-ray spectrometers (EDS) and scanning TEM (STEM) detectors. Results and Discussion: TEM observations reveal that the sectioned grain predominantly consists of a single crystal of low-Ca orthopyroxene, with subsidiary smaller regions of olivine, Fe-Ni sulfide, and Fe-Ni metal. EDS-spectrum imaging and high-resolution TEM (HRTEM) show local, nanocrystalline regions of the outermost 2 to 5 nm of the pyroxene are composed of an Fe-Mg-S-rich and Si- and O-depleted layer that is underlain by a 2- to 5-nm thick amorphous zone enriched in Si. These layers occur in multiple microtome slices and have uniform thicknesses. We also observe localized 'islands' of material on the surface of the pyroxene which HRTEM imaging indicates are amorphous and EDS measurements show are compositionally heterogeneous. A 10- to 60-nm thick partially amorphous zone occurs below the compositionally distinct rim. While this this zone is associated with the compositionally heterogeneous outer layer, it also occurs as a local stand-alone feature on the exterior rim of the grain. Ar-eas of the pyroxene grain rim also exhibit a vesicular texture. The TEM data indicate a complex history of space weather-ing for samples RA-QD02-0042-01 and -02. The outermost layer of nanocrystalline material with varied composition is consistent with previously suggested [3-4] chemical and structural pro-cessing by solar wind ions, with a possible additional role for im-pact vapor deposition [3-4]. The amorphous and compositionally distinct islands on the surface of this grain, similar to lunar glasses, suggest formation through vapor deposition via micrometeor-ite impact events. In comparison, the amorphization and vesicula-tion textures are likely a product of radiation damage from the solar wind. The depth and degree of amorphization, in conjunction with model calculations, will help provide an upper limit on exposure time for these particles.

Thompson, M. S.↗

Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma

Purpose: The aim of this study was to obtain equivalent doses in radiosensitive organs (aside from the bladder and rectum) when applying high-dose-rate (HDR) brachytherapy to a localized prostate carcinoma using {sup 60}Co or {sup 192}Ir sources. These data are compared with results in a water phantom and with expected values in an infinite water medium. A comparison with reported values from proton therapy and intensity-modulated radiation therapy (IMRT) is also provided. Methods: Monte Carlo simulations in Geant4 were performed using a voxelized phantom described in International Commission on Radiological Protection (ICRP) Publication 110, which reproduces masses and shapes from an adult reference man defined in ICRP Publication 89. Point sources of {sup 60}Co or {sup 192}Ir with photon energy spectra corresponding to those exiting their capsules were placed in the center of the prostate, and equivalent doses per clinical absorbed dose in this target organ were obtained in several radiosensitive organs. Values were corrected to account for clinical circumstances with the source located at various positions with differing dwell times throughout the prostate. This was repeated for a homogeneous water phantom. Results: For the nearest organs considered (bladder, rectum, testes, small intestine, and colon), equivalent doses given by {sup 60}Co source were smaller (8%-19%) than from {sup 192}Ir. However, as the distance increases, the more penetrating gamma rays produced by {sup 60}Co deliver higher organ equivalent doses. The overall result is that effective dose per clinical absorbed dose from a {sup 60}Co source (11.1 mSv/Gy) is lower than from a {sup 192}Ir source (13.2 mSv/Gy). On the other hand, equivalent doses were the same in the tissue and the homogeneous water phantom for those soft tissues closer to the prostate than about 30 cm. As the distance increased, the differences of photoelectric effect in water and soft tissue, and appearance of other materials such as air, bone, or lungs, produced variations between both phantoms which were at most 35% in the considered organ equivalent doses. Finally, effective doses per clinical absorbed dose from IMRT and proton therapy were comparable to those from both brachytherapy sources, with brachytherapy being advantageous over external beam radiation therapy for the furthest organs. Conclusions: A database of organ equivalent doses when applying HDR brachytherapy to the prostate with either {sup 60}Co or {sup 192}Ir is provided. According to physical considerations, {sup 192}Ir is dosimetrically advantageous over {sup 60}Co sources at large distances, but not in the closest organs. Damage to distant healthy organs per clinical absorbed dose is lower with brachytherapy than with IMRT or protons, although the overall effective dose per Gy given to the prostate seems very similar. Given that there are several possible fractionation schemes, which result in different total amounts of therapeutic absorbed dose, advantage of a radiation treatment (according to equivalent dose to healthy organs) is treatment and facility dependent.

60 APPLIED LIFE SCIENCES↗

Limit Load and Buckling Analysis for Assessing Hanford Single-Shell Tank Dome Structural Integrity - 12278

The U.S. Department of Energy, Office of River Protection has commissioned a structural analysis of record for the Hanford single shell tanks to assess their structural integrity. The analysis used finite element techniques to predict the tank response to the historical thermal and operating loads. The analysis also addressed the potential tank response to a postulated design basis earthquake. The combined response to static and seismic loads was then evaluated against the design requirements of American Concrete Institute standard, ACI-349-06, for nuclear safety-related concrete structures. Further analysis was conducted to estimate the plastic limit load and the elastic-plastic buckling capacity of the tanks. The limit load and buckling analyses estimate the margin between the applied loads and the limiting load capacities of the tank structure. The potential for additional dome loads from waste retrieval equipment and the addition of large dome penetrations to accommodate retrieval equipment has generated additional interest in the limit load and buckling analyses. This paper summarizes the structural analysis methods that were used to evaluate the limit load and buckling of the single shell tanks. This paper summarizes the structural analysis methods that were used to evaluate the limit load and buckling limit states of the underground single shell tanks at the Hanford site. The limit loads were calculated using nonlinear finite element models that capture the progressive deformation and damage to the concrete as it approaches the limit load. Both uniform and concentrated loads over the tank dome were considered, and the analysis shows how adding a penetration in the center of the tank would affect the limit loads. For uniform surface loads, the penetration does not affect the limit load because concrete crushing and rebar yielding initiates first at the top of the wall, away from the penetration. For concentrated loads, crushing initiates at the center of the dome, so the penetration does reduce the concentrated limit load somewhat. However, the safety factors comparing the limit loads to the maximum allowable applied loads remain well above the required value of 3.0. The buckling analysis method accounts for the geometric imperfections, concrete creep, cracking and reinforcements, and concrete plasticity in determining the allowable buckling load limits. The method was demonstrated in this paper for the evaluation of a tank before and after a penetration is added in the dome center. Finite element buckling models were used to accurately calculate the linear critical buckling loads. The models showed that adding the penetration reduces the linear critical buckling load by only 2.5%. Bounding cases also showed that the possible range of soil support on the walls does not significantly affect the dome buckling loads. Buckling models of the full 360 deg. dome also showed that the dome is more resistant to buckling when the load is offset than when it is positioned over the center. These limit load and buckling analysis methods are being used at the Hanford site to assess the tank loads that can be safely applied during future waste retrieval activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal neutron filter design for the neutron radiography facility at the LVR-15 reactor

In 2011 a decision was made to build a neutron radiography facility at one of the unused horizontal channels of the LVR-15 research reactor in Rez, Czech Republic. One of the key conditions for operating an effective radiography facility is the delivery of a high intensity, homogeneous and collimated thermal neutron beam at the sample location. Additionally the intensity of fast neutrons has to be kept as low as possible as the fast neutrons may damage the detectors used for neutron imaging. As the spectrum in the empty horizontal channel roughly copies the spectrum in the reactor core, which has a high ratio of fast neutrons, neutron filter components have to be installed inside the channel in order to achieve desired beam parameters. As the channel design does not allow the instalment of complex filters and collimators, an optimal solution represent neutron filters made of large single-crystal ingots of proper material composition. Single-crystal silicon was chosen as a favorable filter material for its wide availability in sufficient dimensions. Besides its ability to reasonably lower the ratio of fast neutrons while still keeping high intensities of thermal neutrons, due to its large dimensions, it suits as a shielding against gamma radiation from the reactor core. For designing the necessary filter dimensions the Monte-Carlo MCNP transport code was used. As the code does not provide neutron cross-section libraries for thermal neutron transport through single-crystalline silicon, these had to be created by approximating the theory of thermal neutron scattering and modifying the original cross-section data which are provided with the code. Carrying out a series of calculations the filter thickness of 1 m proved good for gaining a beam with desired parameters and a low gamma background. After mounting the filter inside the channel several measurements of the neutron field were realized at the beam exit. The results have justified the expected calculated values. After the successful filter installing and a series of measurements, first test neutron radiography attempts with test samples could been carried out. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hybrid x-ray/optical luminescence imaging: Characterization of experimental conditions

Purpose: The feasibility of x-ray luminescence imaging is investigated using a dual-modality imaging system that merges x-ray and optical imaging. This modality utilizes x-ray activated nanophosphors that luminesce when excited by ionizing photons. By doping phosphors with lanthanides, which emit light in the visible and near infrared range, the luminescence is suitable for biological applications. This study examines practical aspects of this new modality including phosphor concentration, light emission linearity, detector damage, and spectral emission characteristics. Finally, the contrast produced by these phosphors is compared to that of x-ray fluoroscopy. Methods: Gadolinium and lanthanum oxysulfide phosphors doped with terbium (green emission) or europium (red emission) were studied. The light emission was imaged in a clinical x-ray scanner with a cooled CCD camera and a spectrophotometer; dose measurements were determined with a calibrated dosimeter. Using these properties, in addition to luminescence efficiency values found in the literature for a similar phosphor, minimum concentration calculations are performed. Finally, a 2.5 cm agar phantom with a 1 cm diameter cylindrical phosphor-filled inclusion (diluted at 10 mg/ml) is imaged to compare x-ray luminescence contrast with x-ray fluoroscopic contrast at a superficial location. Results: Dose to the CCD camera in the chosen imaging geometry was measured at less than 0.02 cGy/s. Emitted light was found to be linear with dose (R{sup 2}=1) and concentration (R{sup 2}=1). Emission peaks for clinical x-ray energies are less than 3 nm full width at half maximum, as expected from lanthanide dopants. The minimum practical concentration necessary to detect luminescent phosphors is dependent on dose; it is estimated that subpicomolar concentrations are detectable at the surface of the tissue with typical mammographic doses, with the minimum detectable concentration increasing with depth and decreasing with dose. In a reflection geometry, x-ray luminescence had nearly a 430-fold greater contrast to background than x-ray fluoroscopy. Conclusions: X-ray luminescence has the potential to be a promising new modality for enabling molecular imaging within x-ray scanners. Although much work needs to be done to ensure biocompatibility of x-ray exciting phosphors, the benefits of this modality, highlighted in this work, encourage further study.

60 APPLIED LIFE SCIENCES↗

Resolution enhancement of lung 4D-CT data using multiscale interphase iterative nonlocal means

Purpose: Four-dimensional computer tomography (4D-CT) has been widely used in lung cancer radiotherapy due to its capability in providing important tumor motion information. However, the prolonged scanning duration required by 4D-CT causes considerable increase in radiation dose. To minimize the radiation-related health risk, radiation dose is often reduced at the expense of interslice spatial resolution. However, inadequate resolution in 4D-CT causes artifacts and increases uncertainty in tumor localization, which eventually results in extra damages of healthy tissues during radiotherapy. In this paper, the authors propose a novel postprocessing algorithm to enhance the resolution of lung 4D-CT data. Methods: The authors' premise is that anatomical information missing in one phase can be recovered from the complementary information embedded in other phases. The authors employ a patch-based mechanism to propagate information across phases for the reconstruction of intermediate slices in the longitudinal direction, where resolution is normally the lowest. Specifically, the structurally matching and spatially nearby patches are combined for reconstruction of each patch. For greater sensitivity to anatomical details, the authors employ a quad-tree technique to adaptively partition the image for more fine-grained refinement. The authors further devise an iterative strategy for significant enhancement of anatomical details. Results: The authors evaluated their algorithm using a publicly available lung data that consist of 10 4D-CT cases. The authors' algorithm gives very promising results with significantly enhanced image structures and much less artifacts. Quantitative analysis shows that the authors' algorithm increases peak signal-to-noise ratio by 3-4 dB and the structural similarity index by 3%-5% when compared with the standard interpolation-based algorithms. Conclusions: The authors have developed a new algorithm to improve the resolution of 4D-CT. It outperforms the conventional interpolation-based approaches by producing images with the markedly improved structural clarity and greatly reduced artifacts.

60 APPLIED LIFE SCIENCES↗

Proceedings for the Workshop on Applied Nuclear Data Activities 2024

The Workshop for Applied Nuclear Data Activities (WANDA) is designed to increase communication among nuclear data (ND) users in multidisciplinary federal programs, ND producers, ND funders, and other ND experts. It also presents an opportunity to cross-pollinate ideas as well as introduce ND gaps identified by federal programs to ND experts and ND capabilities to the various federal ND users. WANDA 2024 included five technical sessions, three of which focused on Fusion Energy Sciences (FES)—FES Fusion Neutronics, FES Tritium Production, and FES Material Damage—and two stand-alone sessions—Isotopes and Targetry for Nuclear Data and Uncertainty Quantification. The FES sessions successfully brought new voices to the WANDA discussions, expanding the application space in which nuclear data are critical. FES programs need accurate nuclear data with realistic uncertainty quantification to properly estimate, for example, shielding, activation, tritium production, helium production, structural material integrity, and superconducting magnet operation. This includes a variety of projectile (neutrons, photons, charged particles) and target atoms. One of the action items common to all the FES sessions was a need to perform sensitivity studies to identify the prioritization of nuclear data needs. The Isotopes and Targetry session highlighted the many capabilities available to produce high-quality targets for nuclear data measurements, including 3D printing with spherical powders, combustion synthesis coupled with spin coating & electrospraying, inkjet printing, and isotopic doping. These new methods open doors for more accurate measurement, but it was also stressed that sample characterization following any method of fabrication is of the highest importance to accurately interpret nuclear data measurement results that used that sample. The Uncertainty Quantification (UQ) session was broken into two categories: nuclear data uncertainty quantification and the use of that uncertainty quantification. Thematic to the UQ session was the loss of information when going from nuclear data measurement, to evaluation, to evaluated file, and finally to neutron transport calculations. Current evaluated ND libraries typically only contain covariances, which assume that the probability distributions are Gaussian. Beyond being a simplified assumption for many evaluations, this can lead to negative values on many observables when attempting to sample the covariance. The covariance format, however, is very efficient in that a simple set of linear equations can transform uncertainty from parameters or cross sections to the application of interest. Focused collaboration is needed between nuclear data evaluators and nuclear data users to ensure that needs are being met.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of high-dose gamma-ray irradiation on electrical characteristics of N-polar and Ga-polar GaN p–n diodes

We investigate the impact of high-dose gamma-ray irradiation on the electrical performance of Ga-polar and N-polar GaN-based p-n diodes grown by metalorganic chemical vapor deposition. We compare the current density-voltage (J-V), capacitance-voltage (C-V), and circular transfer length method (CTLM) characteristics of the p-n diodes fabricated on Ga-polar and N-polar orientations before and after irradiation. The relative turn-on voltage increases for the Ga-polar diodes with increasing irradiation dose, while it increases initially and then starts to decrease for the N-polar diodes. The p-contact total resistance increases for Ga-polar and decreases for N-polar samples, which we attribute to the formation of point defects and additional Mg activation after irradiation. The J-V characteristics of most of the tested diodes recovered over time, suggesting the changes in the J-V characteristics are temporary and potentially due to metastable occupancy of traps after irradiation. X-ray photoelectron spectroscopy (XPS) and photoluminescence (PL) measurements reveal the existence of different types of initial defects and surface electronic states on Ga-polar and N-polar samples. Gallium vacancies (V Ga ) are dominant defects in Ga-polar samples, while nitrogen vacancies (V N ) are dominant in N-polar samples. The presence of a higher concentration of surface states on Ga-polar surfaces compared to N-polar was confirmed by calculating the band bending and the corresponding screening effect due to opposite polarization bound charge and ionized acceptors at the surface. The difference in surface stoichiometry in these two orientations is responsible for the different behavior in electrical characteristics after gamma-ray interactions.

36 MATERIALS SCIENCE↗

The Fusion Driven Rocket: Nuclear Propulsion through Direct Conversion of Fusion Energy

The future of manned space exploration and development of space depends critically on the creation of a dramatically more efficient propulsion architecture for in-space transportation. A very persuasive reason for investigating the applicability of nuclear power in rockets is the vast energy density gain of nuclear fuel when compared to chemical combustion energy. The Fusion Driven rocket (FDR) represents a revolutionary approach to fusion propulsion where the power source releases its energy directly into the propellant, not requiring conversion to electricity. It employs a solid lithium propellant that requires no significant tankage mass. The propellant is rapidly heated and accelerated to high exhaust velocity (> 30 km/s), while having no substantial physical interaction with the spacecraft thereby avoiding damage to the rocket and limiting both the thermal heat load and radiator mass. The key to achieving this stems from research at MSNW and the UW on the magnetically driven implosion of metal foils onto a magnetized plasma target to obtain fusion conditions. A logical extension of this work leads to a method that utilizes these metal shells (or liners) to not only achieve fusion conditions, but to serve as the propellant as well. Several low-mass, magnetically driven metal liners are inductively driven to converge radially and axially and form a thick blanket surrounding the target plasmoid and compress the plasmoid to fusion conditions. Virtually all of the radiant, neutron and particle energy from the plasma is absorbed by the encapsulating, thick metal blanket thereby isolating the spacecraft from the fusion. This energy, in addition to the intense Ohmic heating at peak magnetic field compression, is adequate to vaporize and ionize the metal blanket. The expansion of this hot, ionized metal propellant through a magnetically insulated nozzle produces high thrust at the optimal Isp. The energy from the fusion process, along with the waste heat, is thus utilized at very high efficiency. The basic scheme for FDR is illustrated and described in the report (see Fig. 2) The two most critical issues in meeting challenges introduced employing magneto-inertial fusion as the power source is driver efficiency and “stand-off” – the ability to isolate and protect fusion and thruster from the resultant fusion energy. By employing metal shells for compression, it is possible to produce the desired convergent motion inductively by inserting the metal sheets along the inner surface of cylindrical or conically tapered coils. Both stand-off and energy efficiency issues are solved by this arrangement. 3 This two year effort focused on achieving three key criteria for the Fusion Driven Rocket to move forward for technological development: (1) the physics of the FDR must be fully understood and validated, (2) the design and technology development for the FDR required for its implementation in space must be fully characterized, and (3) an in-depth analysis of the rocket design and spacecraft integration as well as mission architectures enabled by the FDR need to be performed. A subscale, laboratory liner compression test facility was assembled at the University of Washington Plasma Dynamics Laboratory with sufficient liner kinetic energy (~ 0.5 MJ) to reach conditions required for fusion breakeven conditions. Detailed experimental studies of the dynamic behavior of the driven liners as well as liner convergence and magnetic compression were performed. The development of both the 1D liner dynamics code and the full 3D ANSYS® liner calculations was achieved. The characterization of both the FDR and spacecraft as well as a design architecture analysis was conducted that included an examination of a wide range of mission architectures and destinations for which this fusion propulsion system would be enabling or critical. In particular a rapid, single launch manned Mars mission was developed.

Energy↗