Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Comparison of graphite, aluminum, and TransHab shielding material characteristics in a high-energy neutron field

Space radiation transport models clearly show that low atomic weight materials provide a better shielding protection for interplanetary human missions than high atomic weight materials. These model studies have concentrated on shielding properties against charged particles. A light-weight, inflatable habitat module called TransHab was built and shown to provide adequate protection against micrometeoroid impacts and good shielding properties against charged particle radiation in the International Space Station orbits. An experiment using a tissue equivalent proportional counter, to study the changes in dose and lineal energy spectra with graphite, aluminum, and a TransHab build-up as shielding, was carried out at the Los Alamos Nuclear Science Center neutron facility. It is a continuation of a previous study using regolith and doped polyethylene materials. This paper describes the results and their comparison with the previous study. Published by Elsevier Science Ltd.

NASA Center JSC↗

Mortality among workers at the Rocky Flats Plant, 1951–2017

The Rocky Flats (RFs) Plant operated from 1951–1989 as part of the U.S. Department of Energy (DOE) nuclear complex. Its primary mission was weapons component fabrication, whereby workers were potentially exposed to radioactive and non-radioactive hazards. RF worker mortality was compared to the general population, and dose-response relationships between mortality and radiation organ doses were examined. RF workers first employed between 1951 and 1979 for ⩾30 d were identified (n = 9397). Vital status was determined using national and state death records up to 2017. Organ doses from external photons and neutrons irritation and internalised plutonium (Pu), americium (Am), and uranium (U) were modelled as cumulative lagged total doses per year. Beryllium exposure was evaluated as an effect modifier using data from the DOE Nationwide Beryllium Medical Program. Statistical analyses included standardised mortality ratios (SMRs), Cox proportional hazard models, and excess relative risk (ERR) models. Approximately 53.2% of workers were deceased by the end of the study. Nearly 90% were monitored for radiation exposure, with a mean weighted absorbed dose of 59.0 mGy for the lungs. Nearly 45% of workers had intakes of alpha-particle emitting radionuclides, and 46.7% were monitored for neutrons. Leading causes of death included ischemic heart disease (n = 999) and lung cancer (n = 361). The highest SMRs were observed for berylliosis (SMR: 176.9; 95% CI: 76.2, 348.7; n < 10) and asbestosis (SMR: 4.65; 95% CI: 2.23, 8.55; n = 10). Dose-response analyses showed no statistical increase in risk from low-dose radiation including lung cancer (ERR per 100 mGy: −0.02; 95% CI: −0.11, 0.08; n = 361) and Parkinson’s disease (ERR per 100 mGy: 0.13; 95% CI: −0.26, 0.31; n = 57). Approximately 45% of workers were monitored for beryllium, with a weak non-significant indication of effect modification for lung cancer risk. The RF cohort showed no evidence of a statistically significant increase in mortality from occupational radiation exposure. However, this study was limited by low statistical power, which inhibits the ability to detect effects. Future pooling of Million Person Study (MPS) cohorts will provide further insights, particularly regarding Pu as a carcinogen.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ash loading and insolation at Hanford, Washington during and after the eruption of Mount St. Helens

The effects of volcanic ash suspended in the atmosphere on the incident solar radiation was monitored at the Hanford Meteorological Station (HMS) subsequent to the major eruption of Mount St. Helens on May 18, 1980. Passage of the ash plume over Hanford resulted in a very dramatic decrease of solar radiation intensity to zero. A reduction in visibility to less than 1 km was observed, as great quantities of ash fell out of the plume onto the ground. Ash loading in the atmosphere remained very high for several days following the eruption, primarily as a result of resuspension from the surface. Visibilities remained low (2 to 8 km) during this period. Estimates of atmospheric turbidity were made from the ratio of diffuse-to-direct solar radiation; these turbidities were used to estimate extinction along a horizontal path, a quantity which can be related to visibility. Comparisons of observed and estimated visibilities were very good, in spite of the rather coarse approximations used in the estimates. Atmospheric clarity and visibility improved to near pre-eruption conditions following a period of rain showers. The diffuse-to-direct ratio of solar radiation provided a useful index for estimating volcanic ash loading of the atmosphere.

Laulainen, N. S.↗

A 400 kilowatt argon arc lamp for solar simulation

A 400 kilowatt argon arc lamp for a solar simulator has been designed, operated, and evaluated. The lamp is designed to produce one solar constant on a test area 4.6 by 9.2 meters when used with a collimator. The divergence angle of the beam is about 1 deg. The lamp is designed to operate completely within a vacuum environment. Over 80 kilowatt of directed radiation was monitored and measured for a 25-hour period during a recent test. In another test, an arc was operated at 400 kilowatt for 110 hours without removal or refurbishing of the electrodes. These tests have proven the cleanliness and integrity of the radiation source.

Decker, A. J.↗

Simultaneous measurement of multiple radiation-induced protein expression profiles using the Luminex(TM) system

Space flight results in the exposure of astronauts to a mixed field of radiation composed of energetic particles of varying energies, and biological indicators of space radiation exposure provides a better understanding of the associated long-term health risks. Current methods of biodosimetry have employed the use of cytogenetic analysis for biodosimetry, and more recently the advent of technological progression has led to advanced research in the use of genomic and proteomic expression profiling to simultaneously assess biomarkers of radiation exposure. We describe here the technical advantages of the Luminex(TM) 100 system relative to traditional methods and its potential as a tool to simultaneously profile multiple proteins induced by ionizing radiation. The development of such a bioassay would provide more relevant post-translational dynamics of stress response and will impart important implications in the advancement of space and other radiation contact monitoring. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

NASA Center JSC↗

Crystal Growth Scale-Up and Stability of RbSr 2 X 5 :Eu Scintillators

The discovery and development of new scintillation materials support national security needs. In these applications, large volumes of scintillator crystals are needed to achieve efficient screening for contraband. Therefore, one important step in the discovery of new scintillator compositions is testing their feasibility for scale-up and their stability. In this work, high-quality Ø22 mm crystals of two new scintillators RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu were grown via the Vertical Bridgman method, and their scintillation properties were characterized. Here, the Ø22 mm RbSr 2 I 5 :Eu crystals could be grown with fast translation rates up to 3.5 mm/h. Both RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu had high scintillation performance, including light yields of 46,000 and 61,000 ph/MeV, respectively, for Ø22 × 35 mm crystals. Additionally, properties related to physical stability were investigated, including the coefficients of thermal expansion via high-temperature X-ray diffraction (HTXRD) as well as moisture sensitivity. HTXRD confirmed the absence of solid–solid phase transitions and showed that RbSr 2 Br 5 had minimal thermal expansion anisotropy compared to RbSr 2 I 5 and some other inorganic metal halide scintillators, which favors the growth of large-sized crystals.

36 MATERIALS SCIENCE↗

Search for effects of Comet S-L 9 fragment impacts on low radio frequency emission from Jupiter

Decametric radio observations of Jupiter were made before, during, and after the impacts of the fragments of the comet S-L 9 with the planet, from the University of Florida Radio Observatory, the Maipu Radio Astronomy Observatory of the University of Chile, and the Owens Valley Radio Observatory of the California Institute of Technology. The decametric radiation was monitored at frequencies from 16.7 to 32 MHz. The minimum detectable flux densities were on the order of 30 kJy, except for that of the large 26.3 MHz array in Florida, which was about 1 kJy. There was no significant enhancement or suppression of the decametric L-burst or S-burst emission with respect to normal activity patterns that might be attributed to the fragment entries. A burst of left-hand elliptically polarized radiation having a considerably longer duration than an L-burst was observed almost simultaneously with the impact of the large fragment Q2, and another with right-hand elliptical polarization was observed simultaneously with Q1. We consider the possibility that these two bursts were emitted just above the local electron cyclotron frequencies from the southern and northern ends, respectively, of magnetic flux tubes that had been excited in some way by the proximity of fragments Q2 and Q1. A search was conducted for possible comet-enhanced Jovian synchrotron radiation at 45 MHz using a large dipole antenna array at the observatory in Chile.

Carr, T. D.↗

Monitoring Temperatures of Tires Using Luminescent Materials

A method of noncontact, optical monitoring of the surface temperature of a tire has been devised to enable the use of local temperature rise as an indication of potential or impending failures. The method involves the use of temperature-sensitive paint (or filler): Temperature-sensitive luminescent dye molecules or other luminescent particles are incorporated into a thin, flexible material coating the tire surface of interest. (Alternatively, in principle, the luminescent material could be incorporated directly into the tire rubber, though this approach has not yet been tested.) The coated surface is illuminated with shorter-wavelength light to excite longer-wavelength luminescence, which is observed by use of a charge-coupled-device camera or a photodetector (see Figure 1). If temporally constant illumination is used, then the temperature can be deduced from the known temperature dependence of the intensity response of the luminescence. If pulsed illumination is used, then the temperature can be deduced from the known temperature dependence of the time or frequency response of the luminescence. If sinusoidally varying illumination is used, then the temperature can be deduced from the known temperature dependence of the phase response of the luminescence. Unlike a prior method of monitoring the temperature at a fixed spot on a tire by use of a thermocouple, this method is not restricted to one spot and can, therefore, yield information on the spatial distribution of temperature: in particular, it enables the discovery of newly forming hot spots where damage may be starting. Also unlike in the thermocouple method, the measurements in this method are not vulnerable to breakage of wires in repeated flexing of the tire. Moreover, unlike in another method in which infrared radiation is monitored as an indication of surface temperature, the luminescence measurements in this method are not significantly affected by changes in infrared emissivity. This method has been demonstrated in application to the outside surface of a tire (see Figure 2), using both constant and pulsed light sources for illumination and cooled, slow-scan, gated CCD cameras for detection. For observing the temperature of the inside surface of a tire (this has not yet been done), it would probably be necessary to use fiber optics and/or windows for coupling excitation light into, and coupling luminescence out of, the interior volume.

Bencic, Timothy J↗

Fast, Large Area, Wide Band GAP UV Photodetector for Cherenkov Light Detection

A solid-state radiation detector includes a pattern of conductive metal on a zinc oxide substrate. The pattern provides an arrangement of interdigitated electrode fingers. The wide band gap substrate is sensitive to UV light, which can cause a conductivity change in the substrate. The electrode fingers are configured to sense a difference in substrate conductivity resulting from UV light. The detector has a fast response time, which enables it to detect Cherenkov light. The compact detector provides savings on size, weight, and required power. Thus, the solid-state detector can be used to replace photomultiplier tubes in Cherenkov detectors. The features of the novel detector allow for an improved system to detect and monitor UV radiation, especially during deep space missions.

Wrbanek, John D.↗

Tensioned metastable fluid detector sensing technology for multifarious-multiscale applications in the nuclear fuel cycle

The nuclear fuel cycle presents formidable 10 30+ multiscale challenges for high-efficiency spectroscopic sensing of alpha-neutron-fission radiation signatures amidst extreme gamma-beta radiation backgrounds at various stages of the cycle; it involves diverse arenas ranging from continuous/pulsed power production, security/safeguards, spent fuel, environmental remediation, and personnel health-dosimetry. This paper discusses the novel tensioned metastable fluid detector (TMFD) sensor technology. It discusses the results of studies demonstrating extreme (10 4 Sv/h) gamma-beta field blind high intrinsic efficiencies (80–100%) for neutron-alpha-fission radiation spectrometric detection. Example studies discussed in this paper include Neutron detection with spectroscopy; H*10 neutron radiation dosimetry upwards from ultra-low10 −2 µSv/h levels; Air and/or liquid-borne trace (10 –3 Bq/mL) quantity, 1 keV energy resolved alpha/fission spectroscopy for Rn/Po/U/Pu/Am environmental isotope assays at 106:1 (β:α) ratios; Directional-position enabled extended standoff tracking of neutron emitting (shielded/unshielded) special nuclear materials while stationary or moving at highway speeds; and, U.S. Department of Energy nuclear complex wide nuclear waste reprocessing, criticality safety, health physics, and environmental applications.

Alpha-fission-neutron spectrometry↗

Final Report on Radiation Measurements Performed Inside of the BEAM Module

Measurements of the radiation environment inside of the Bigelow Expandable Activity Module (BEAM) have been made on a pseudo-continuous basis since June 6, 2016 using both passive and active instrumentation. Passive detectors yield a single cumulative dose value (or average daily dose) over the measurement period from deploy to return to ground. Active Radiation Environment Monitor (REM) sensors yield dose rate, Linear Energy Transfer (LET) spectra, and particle-specific dose, all on a 1-minute cadence. From the initial install in 2016 until early 2018, BEAM was an empty module. In 2018, further testing was approved and stowage began to be moved into BEAM. As a result, it was decided to stop measurements with RAM detectors to avoid potential difficulties with access after stowage was added. The REM sensors remained however in the original deploy locations.

radiation exposure↗

Energy migration and scintillation kinetics in compositionally complex (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce single crystal scintillator

It is well-established that compositional tuning through binary admixture can improve scintillation performance in several materials systems, including Ce-activated garnets. Although recent work on ternary or quaternary cation admixture shows promise, the impact of this increased compositional complexity on thermal stability and carrier-defect dynamics has not been addressed. Here, we investigate a compositionally complex garnet, (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce (GYTLAG), grown by the Czochralski method using temperature-dependent photoluminescence (PL), PL decay, and thermoluminescence (TL). PL and PL decay measurements support a thermally activated Tb 3+ -Ce 3+ energy transfer, where Tb 3+ emission dominates below 60 K, but Ce 3+ emission increases from 20-300 K. Thermal quenching of Ce 3+ emission occurs around T 50 = 508 K, with an activation energy of 0.6 eV. TL and wavelength-resolved TL spectra from 20–500 K show that GYTLAG contains similar trap groups to LuAG but with a broader distribution of glow peaks below room temperature, possibly caused by quaternary cation mixing. A combination of dose dependence, partial cleaning and initial rise, and glow curve fitting to a first order continuous Gaussian distribution model are used to understand the contribution of electronic point defects to scintillation decay and afterglow at room temperature. Furthermore, these results inform how increased compositional complexity influences recombination dynamics in garnet scintillators.

Compositionally complex↗

Czochralski Growth and Characterization of a Compositionally Complex Rare Earth Aluminum Garnet Scintillator: (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce

Compositionally complex oxides have garnered increasing interest for their enhanced phase stability and tunable functional properties, yet their development as bulk single crystal scintillators remains limited. Herein, we report the Czochralski growth and characterization of (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce (GYTLAG), a compositionally complex garnet incorporating four dodecahedrally coordinated principal rare earth elements. The garnet phase was confirmed by powder and single crystal X-ray diffraction, and macroscopic defects are described. X-ray absorption near-edge structure measurements confirm the 3+ oxidation state of all rare earths and support their occupation of the same crystallographic site; white line intensity variations correlate with the anticipated segregation behavior. Elemental segregation is quantified by SEM/EDS and ICP-OES, and a linear trend was established between the segregation coefficient and the difference between each rare earth’s ionic radius (r) and the average ionic radius (AIR) of the dodecahedral site. This trend offers a predictive framework for compositional control in future REAG crystals grown by the Czochralski method. Photoluminescence and radioluminescence measurements reveal both Ce 3+ and Tb 3+ emission. Scintillation pulses exhibit four-component decay with dominant ~230 µs and ~1.2 ms components, and the light yield is estimated to be up to 43,000 ph/MeV under 137Cs γ-ray excitation. GYTLAG also demonstrates a strong radioluminescence efficiency and 50% lower afterglow at 20 ms compared to a LuAG:Ce reference, underscoring its promise for scintillator applications.

Compositionally complex oxide, high entropy oxide,↗

Deep Multitask Learning Models for Radiation Estimation at High Energy Accelerator Facility

Controlling the dose of radiation exposure in potential radioactive facilities is critical for ensuring the safety of staff and the public. Here, in this paper, we developed machine learning models to estimate radiation exposure efficiently at the Thomas Jefferson National Accelerator Facility (JLab), aiming to enhance safety in both accelerator facilities and public areas. Multiple sensors were deployed around the three experimental halls at JLab. Data on single-beam currents, energy levels, and radiation values at the sensor locations were collected during accelerator operation. We proposed a multi-task learning model for radiation estimation, utilizing either one-dimensional convolutional neural networks (1-D CNNs) or long short-term memory networks (LSTMs) as the backbone. The proposed model was trained to simultaneously estimate radiation levels at the sensor locations. Experimental results demonstrated that the proposed model with LSTM backbone achieved the best estimation performance, with an average R 2 score of 0.7557 for estimation within the same year and 0.7157 for estimation across different years. These results significantly surpassed those of competing models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin-Polarized Electron Sources Based on Group II-VI Compounds Grown by Atomic Layer Deposition

This project explored ALD as an alternative growth technique for II–VI photocathodes and assessed CdTe for spin-polarized electron production. Working with BNL (Cultrera group), we established the workflow to measure QE and spin polarization using BNL’s Mott polarimeter, and we prepared both conventional Cs/O NEA activation and a heterostructure NEA route leveraging an ultrathin Cs2Te overlayer. The latter provides a pragmatic activation alternative while maintaining photoexcitation primarily in CdTe.

43 PARTICLE ACCELERATORS↗

Laser energy converted into electric power

Apparatus verifies concepts of converting laser energy directly into electric energy. Mirror, placed in beam and inclined at angle to it, directs small amount of incident radiation to monitor which establishes precise power levels and other beam characteristics. Second mirror and condensing lens direct bulk of laser energy into laser plasmadynamic converter.

Shimada, K.↗