Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiator Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Dosimetric and biological impact of activity extravasation of radiopharmaceuticals in PET imaging

The increasing use of nuclear medicine and PET imaging has intensified scrutiny of radiotracer extravasation. To our knowledge, this topic is understudied but holds great potential for enhancing our understanding of extravasation in clinical PET imaging. This work aims to (1) quantify the absorbed doses from radiotracer extravasation in PET imaging, both locally at the site of extravasation and with the extravasation location as a source of exposure to bodily organs and (2) assess the biological ramifications within the injection site at the cellular level. A radiation dosimetry simulation was performed using a whole-body 4D Extended Cardiac-Torso (XCAT) phantom embedded in the GATE Monte Carlo platform. A 10-mCi dose of 18 F-FDG was chosen to simulate a typical clinical PET scan scenario, with 10% of the activity extravasated in the antecubital fossa of the right arm of the phantom. The extravasation volume was modeled as a 5.5 mL rectangle in the hypodermal layer of skin. Absorbed dose contributions were calculated for the first two half-lives, assuming biological clearance thereafter. Dose calculations were performed as absorbed doses at the organ and skin levels. Energy deposition was simulated both at the local extravasation site and in multiple organs of interest and converted to absorbed doses based on their respective masses. Each simulation was repeated ten times to estimate Monte Carlo uncertainties. Biological impacts on cells within the extravasated volume were evaluated by randomizing cells and exposing them to a uniform radiation source of 18 F and 68 Ga. Particle types, their energies, and direction cosines were recorded in phase space files using a separate Geant4 simulation to characterize their entry into the nucleus of the cellular volume. Subsequently, the phase space files were imported into the TOPAS-nBio simulation to assess the extent of DNA damage, including double-strand breaks (DSBs) and single-strand breaks (SSBs). Organ-level dosimetric estimations are presented for 18 F and 68 Ga radionuclides in various organs of interest. With 10% extravasation, the hypodermal layer of the skin received the highest absorbed dose of 1.32 ± 0.01 Gy for 18 F and 0.99 ± 0.01 Gy for 68 Ga. The epidermal and dermal layers received absorbed doses of 0.07 ± 0.01 Gy and 0.13 ± 0.01 Gy for 18 F, and 0.14 ± 0.01 Gy and 0.29 ± 0.01 Gy for 68 Ga, respectively. In the extravasated volume, 18 F caused an average absorbed dose per nucleus of 0.17 ± 0.01 Gy, estimated to result in 10.58 ± 0.50 DSBs and 268.11 ± 12.43 SSBs per nucleus. For 68 Ga, the absorbed dose per nucleus was 0.11 ± 0.01 Gy, leading to an estimated 6.49 ± 0.34 DSBs and 161.24 ± 8.12 SSBs per nucleus. Absorbed doses in other organs were on the order of micro-gray (µGy). The likelihood of epidermal erythema resulting from extravasation during PET imaging is low, as the simulated absorbed doses to the epidermis remain below the thresholds that trigger such effects. Moreover, the organ-level absorbed doses were found to be clinically insignificant across various simulated organs. The minimal DNA damage at the extravasation site suggests that long-term harm, such as radiation-induced carcinogenesis, is highly unlikely.

DNA strand breaks↗

Fiber-Optic Bolometer and Calorimeter Arrays for Magnetically Confined Plasmas

Bolometers measure the plasma radiation and provide essential diagnostic information both for safe, sustainable operation of magnetic-confinement fusion (MCF) devices and for study of the relevant physics. The fusion community has been replying on resistive bolometers for plasma radiation measurement. However, their performance is greatly compromised by the strong electromagnetic interference present in MCF devices. Previously, we have demonstrated a fiber-optic bolometer that has the promise to overcome the challenges related to the strong EMI in the MCF environment. In this project, we study the performance of the fiber-optic bolometer in a simulated MCF environment and improved the sensitivity through a novel sensor design. Part of the work reported here was performed between 09/01-12/31/2017 when the PI was with University of Nebraska-Lincoln under the same project but with a different award number (DE-SC0018273).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

Radiation Effects in Used Next Generation Nuclear Fuel Reprocessing Strategies

Given global commitments to significantly increase nuclear energy capacity, it is now more important than ever to develop efficient used nuclear fuel (UNF) management strategies to encourage widespread adoption of closed fuel cycles. To achieve this ambitious goal, a comprehensive understanding of radiation effects is essential for these next generation technologies, as radiolysis often limits longevity and performance. Here, we present new findings on: (i) the radiation robustness and performance of advanced sulfur chloride-based chlorination processes in the presence of nuclear materials (Fig. 1A); and (ii) the impacts of voloxidized uranium and rhenium complexation on monoamide-based UNF direct dissolution strategies (Fig 1B). These studies employed a combination of time-resolved electron pulse and dose accumulation gamma and electron beam irradiation techniques.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

A Cryogenic Muon Tagging System Integrated with a Superconducting Qubit Device for Radiation-Induced Error Mitigation

Superconducting qubits are highly sensitive to ionizing radiation, which can induce correlated errors and limit scalable fault-tolerant quantum computing. In particular, cosmic-ray muons can deposit energy in the substrate, generating phonon bursts that break Cooper pairs and produce quasiparticles, leading to correlated decoherence events across multiple qubits. We present the development of a cryogenic muon tagging system based on Kinetic Inductance Detectors (KIDs) and its integration with superconducting quantum hardware. Originally developed within the ACE-SuperQ project and validated as a standalone detector, the system demonstrated a muon tagging efficiency of approximately 90% and excellent agreement with Monte Carlo simulations. Building on this validation, the tagging system has been integrated with a multi-qubit superconducting chip operated in a dilution refrigerator. The detector configuration consists of a multi-layer KID stack arranged above and below the quantum device, enabling time-coincident identification of muon-induced events within the same cryogenic environment. The integrated setup has been successfully commissioned, enabling simultaneous operation of the qubit chip and the muon tagging system. A first measurement campaign has been carried out, and preliminary data show time-correlated events between the muon tagging detectors and the qubit readout. A quantitative analysis of radiation-induced effects on qubit performance is currently ongoing. This work represents a step toward the implementation of event-level radiation tagging as a tool for characterizing and potentially mitigating correlated errors in superconducting quantum processors, while establishing a modular platform for future studies at the interface between particle physics and quantum information science.

Roy, Tanay [Fermilab] (ORCID:000000019442862X)↗

X-ray heating and electron temperature of laboratory photoionized plasmas

We discuss experimental and modeling results for the x-ray heating and temperature of laboratory photoionized plasmas. A method is used to extract electron temperature based on the analysis of transmission spectroscopy data that is independent of atomic kinetics modeling. Boltzmann kinetic and radiation-hydrodynamics simulations emphasized the critical interplay between atomic physics and heating in photoionized plasmas. They also demonstrated the dramatic impact of photoexcitation on excited state populations, line emissivity, and radiation cooling. Temperature calculations performed with astrophysical codes significantly overestimated the measurement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nuclear Science User Facilities FY 2020 Program Performance Summary

The Nuclear Science User Facilities (NSUF) first gathered and reported metric data for Fiscal Year (FY) 2014. The goal of the FY 2014 NSUF Metric Report was to establish metric measures and to provide baseline data to evaluate future performance of the NSUF. Each metric goal and objective was established through NSUF discussions with Department of Energy (DOE) Idaho Operations Office and Office of Nuclear Energy staff. This report provides the data, analysis, and conclusions for the FY 2020 metrics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimizing Treatment in Intermediate-Risk Prostate Cancer: Secondary Analysis of a Randomized Phase 3 Trial

To identify patients with intermediate-risk prostate cancer (IRPC) benefiting from de-escalation of androgen deprivation therapy (ADT) and/or dose escalated radiation therapy (DERT), we performed a secondary analysis of a phase 3 trial by measuring biochemical failure (BF), distant metastases, prostate cancer–specific mortality, overall survival (OS), and distant metastases-free survival (DMFS) rates according to prognostic intermediate risk factors (IRF).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

All-sky aerosol direct radiative effects at the ARM SGP site

All-sky aerosol direct radiative effect (DRE) was estimated for the first time at the Atmospheric Radiation Measurement Southern Great Plains site using multi-year ground-based observations. The NASA Langley Fu-Liou radiation model was employed. Observed inputs for the radiation model include aerosol and cloud vertical extinction profile from Raman lidar; spectral aerosol optical depth, single-scattering albedo, and asymmetry factor from Aerosol Robotic Network; cloud water content profiles from radars; temperature and water vapor profiles from radiosondes; and surface shortwave spectral albedo from radiometers. A cloudy-sky radiative closure experiment was performed. The relative mean differences between modeled and observed surface downwelling shortwave total fluxes were 6% (7%) for transparent (opaque) cloudy-skies. The estimated annual mean all-sky aerosol DRE is -2.13±0.54W m -2 at the top of atmosphere (TOA) and -5.95±0.87 W m -2 at the surface, compared to -3.00±0.58 W m -2 AND -6.85±1.00 W m -2 , respectively, under clear-sky conditions. The seasonal cycle of all-sky aerosol DRE is similar to that of the clear-sky, except with secondary influences of the clouds: The cloud radiative effect is strongest (most negative) in the spring, which reduces the all-sky aerosol DRE. The relative uncertainties in all-sky aerosol DRE due to measurement errors are generally comparable to those in clear-sky conditions except for the aerosol single-scattering albedo. Finally, the TOA all-sky aerosol DRE relative uncertainty due to aerosol single-scattering albedo uncertainty is larger than that in clear-sky, leading to a larger total relative uncertainty. The measurement errors in cloud properties have small effects on the all-sky aerosol DRE.

54 ENVIRONMENTAL SCIENCES↗

Cadmium Magnesium Telluride for Next Generation X-Ray Free Electron Laser, Synchrotron and Many Other Applications

We developed a picosecond photodetector based on our Bridgman grown and specially engineered Cadmium Magnesium Telluride (Cd 1-x Mg x Te) single crystal that is sensitive to both optical and x-ray pulses for coarse timing in Free Electron Laser applications. Cd 1-x Mg x Te is a wide bandgap semiconductor material with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma ray radiation, thermal neutrons, and medical imaging. However, for femtosecond optical and x-ray cross correlation, the material has to have very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have very low bulk leakage current, in the 0.10 pA range. Hence the ability to tailor or engineer the material is very crucial. In this paper, picosecond response and the crystal growth of this specially engineered cadmium magnesium telluride material will be presented. Other material characterization and transient measurements will also be discussed along with room temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications

We developed a picosecond photodetector based on our Bridgman-grown and specially engineered cadmium magnesium telluride (Cd 1–x MgxTe) single crystal that is sensitive to both optical and X-ray pulses for coarse timing in free-electron laser applications. Cd 1–x MgxTe is a widebandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and X-ray crosscorrelation, the material must have a very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have a very low bulk leakage current, in the 10–90 nA range for voltages to even 1000 V. Hence, the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1–x MgxTe material are presented. Furthermore, other characterization and transient measurements are discussed along with room-temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

First-principles-integrated Study of Blazar Synchrotron Radiation and Polarization Signatures from Magnetic Turbulence

Blazar emission is dominated by nonthermal radiation processes that are highly variable across the entire electromagnetic spectrum. Turbulence, which can be a major source of nonthermal particle acceleration, can widely exist in the blazar emission region. The Turbulent Extreme Multi-Zone (TEMZ) model has been used to describe turbulent radiation signatures. Recent particle-in-cell (PIC) simulations have also revealed the stochastic nature of the turbulent emission region and particle acceleration therein. However, radiation signatures have not been systematically studied via first-principles-integrated simulations. In this paper, we perform combined PIC and polarized radiative transfer simulations to study synchrotron emission from magnetic turbulence in the blazar emission region. We find that the multiwavelength flux and polarization are generally characterized by stochastic patterns. Specifically, the variability timescale and average polarization degree (PD) are governed by the correlation length of the turbulence. Interestingly, magnetic turbulence can result in polarization angle swings with arbitrary amplitudes and duration, in either direction, that are not associated with changes in flux or PD. Surprisingly, these swings, which are stochastic in nature, can appear either bumpy or smooth, although large-amplitude swings (>180°) are very rare, as expected. Our radiation and polarization signatures from first-principles-integrated simulations are consistent with the TEMZ model, except that in the latter, there is a weak correlation, with zero lag, between flux and degree of polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

Feasibility and performance of the staged Z-pinch: A one-dimensional study with FLASH and MACH2

Z-pinch platforms constitute a promising pathway to fusion energy research. Here, we present a one-dimensional numerical study of the staged Z-pinch (SZP) concept using the FLASH and MACH2 codes. We discuss the verification of the codes using two analytical benchmarks that include Z-pinch-relevant physics, building confidence on the codes' ability to model such experiments. Then, FLASH is used to simulate two different SZP configurations: a xenon gas-puff liner (SZP1*) and a silver solid liner (SZP2). The SZP2 results are compared against previously published MACH2 results, and a new code-to-code comparison on SZP1* is presented. Using an ideal equation of state and analytical transport coefficients, FLASH yields a fuel convergence ratio (CR) of approximately 39 and a mass-averaged fuel ion temperature slightly below 1 keV for the SZP2 scheme, significantly lower than the full-physics MACH2 prediction. For the new SZP1* configuration, full-physics FLASH simulations furnish large and inherently unstable CRs (>300) but achieve fuel ion temperatures of many kilo-electron volts. While MACH2 also predicts high temperatures, the fuel stagnates at a smaller CR. The integrated code-to-code comparison reveals how magnetic insulation, heat conduction, and radiation transport affect platform performance and the feasibility of the SZP concept.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-LTE modelling of cyanoacetylene: evidence for isomer-specific excitation

ABSTRACT Cyanoacetylene molecules are widespread in the interstellar medium (ISM) and several of its isomers have been detected in cold molecular clouds and circumstellar gas. Accurate estimates of the abundance ratio of cyanoacetylene isomers may provide deep insight into their environment. Such knowledge requires rigorous modelling of the emission spectra based on non-local thermodynamic equilibrium (LTE) radiative transfer calculations. To this end, we computed excitation cross-sections of HC2NC and HNC3 induced by collision with para- and ortho-H2, using a quantum mechanical close-coupling method. Then, by thermally averaging these data, we derived rate coefficients for the first 31 low-lying rotational levels of each isomer for temperatures up to 80 K. For the para-H2 collider, the propensity rules are in favour of rotational transitions involving Δj1 = 2 for both isomers, while for the ortho-H2 collider, Δj1 = 2 and Δj1 = 1 rotational transitions are favoured for HC2NC and HNC3, respectively. A comparison of rate coefficients for the HC3N isomers shows differences up to an order of magnitude, especially at low temperatures. Finally, we performed non-LTE radiative transfer calculations to assess the impact of such variations in the analysis of observations. Our simulation suggests that the lack of collisional data specific to each isomer could lead to errors up to a factor of 2–3 in the excitation temperatures. We expect that these data could help in better understanding the cyanoacetylene chemistry and constraining the nitrogen chemistry in the ISM.

79 ASTRONOMY AND ASTROPHYSICS↗

First measurement of the 10B(α,n)13N reaction in an inertial confinement fusion implosion at the National Ignition Facility: Initial steps toward the development of a radiochemistry mix diagnostic

We report the first measurement of the 10B(α,n)13N reaction in a polar-direct-drive exploding pusher (PDXP) at the National Ignition Facility (NIF). This work is motivated by the need to develop alternative mix diagnostics, radiochemistry being the focus here. The target is composed of a 65/35 at. % deuterium–tritium (DT) fill surrounded by a roughly 30 μm thick beryllium ablator. The inner portion of the beryllium ablator is doped with 10 at. % of 10B. Radiation-hydrodynamics calculations were performed in 1D to optimize both the remaining boron rho-R and the DT neutron yield. A charged-particle transport post-processor has been developed to study α-induced reactions on the ablator material. Results indicate a large 13N production from α-induced reactions on 10B, measurable by the radiochemical analysis of a gaseous samples system at the NIF. The PDXP target N201115-001 was successfully fielded on the NIF, and nitrogen from the 10B(α,n)13N reaction was measured. The 13N production yield, as well as the DT neutron yield, was, however, lower than expected. Some of the reduced yields can be explained by the oblate shape, but the ratios of the various radiochemical signals are not commensurate with expectations based on a simple reduction of the 1D results. Preliminary 2D radiation-hydrodynamics computations are consistent with the experimental measurements, and work is ongoing to extend the radiochemistry analysis into higher dimensions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation Transport Simulation of the Sulfur Counting System in the Radiation Metrology Laboratory (RML)

At the request of staff members from the Radiation Metrology Laboratory (RML), a series of Monte Carlo radiation transport calculations were performed using two different models of the detector geometry of the RMLs sulfur counting system. The fraction of electrons from each β-decay of 32 P in the sulfur pellet that enter the window of the sulfur counting system was calculated with both MCNP and ITS. In addition, the differential energy distributions of the electrons entering the counting system window were computed. There was significant agreement between the integral and differential quantities calculated by the two transport codes. Summary tables are for the integral efficiency values are found in the body of the report.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A custom high-stability pulse generator for the test of a novel in-situ magnetic sensor developed to detect radiation damage in undulators

High-performance analog-to-digital converters (ADC) have been widely applied in many areas of science. For instance, magnetic field measurements based on the Faraday’s induction law require high-precision voltmeters to measure induced voltages. In this study in the context of free-electron lasers technology, the Magnetic Measurements Team at SLAC National Accelerator Laboratory proposed a novel in-situ radiation damage detection system (RDDS) for detecting small field variations in undulators. The system measures the flux change in a flexible printed-circuit coil attached to the magnet array during the undulator gap movement. The gap movement changes the magnetic field, which induces a voltage signal in the coil that is measured and integrated with an ADC. Although the system is capable of detecting relative flux changes better than 100 ppm, drift in the ADC’s gain or offset can cause apparent changes in the relative flux. This paper describes the first attempt to developed a high-precision verification circuit to perform ADC testing in the framework of the novel RDDS. The circuit generates a reference voltage pulse with a voltage–time integral relative precision better than 50 ppm for a few hundreds of mVs — the typical order of magnitude measured with the RDDS. The circuit’s design combines a fast and precise switch with a low-noise voltage reference. Long-term measurements allowed statistical analysis and showed that averaging the voltage–time integral of ten pulses gives the required 50 ppm stability. Moreover, reproducibility tests confirmed that the circuit’s output is invariable under small power supply instabilities and equipment shutdown. Instruments and applications designed to quantify the magnetic field by integrating voltage signals may use the pulse generator proposed in this paper for verification purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗