Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiological Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Single Iridium Atom Doped Ni 2 P Catalyst for Optimal Oxygen Evolution

Single-atom catalysts (SACs) with 100% active sites have excellent prospects for application in the oxygen evolution reaction (OER). However, further enhancement of the catalytic activity for OER is quite challenging, particularly for the development of stable SACs with overpotentials <180 mV. Here, we report an iridium single atom on Ni 2 P catalyst (Ir SA -Ni 2 P) with a record low overpotential of 149 mV at a current density of 10 mA·cm –2 in 1.0 M KOH. The Ir SA -Ni 2 P catalyst delivers a current density up to ∼28-fold higher than that of the widely used IrO 2 at 1.53 V vs RHE. Both the experimental results and computational simulations indicate that Ir single atoms preferentially occupy Ni sites on the top surface. The reconstructed Ir–O–P/Ni–O–P bonding environment plays a vital role for optimal adsorption and desorption of the OER intermediate species, which leads to marked enhancement of the OER activity. Additionally, the dynamic “top-down” evolution of the specific structure of the Ni@Ir particles is responsible for the robust single-atom structure and, thus, the stability property. In conclusion, this Ir SA -Ni 2 P catalyst offers novel prospects for simplifying decoration strategies and further enhancing OER performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Content Clonogenic Survival Screen to Identify Chemoradiation Sensitizers

The combination of cytotoxic chemotherapy with radiation therapy (CRT) has resulted in significant improvements in clinical outcomes for patients with many locally advanced unresectable cancers. Only a small proportion of patients achieve pathologic complete responses to CRT; combination of CRT with targeted agents offers the promise of further improving treatment responses. However, numerous clinical trials have failed to show an improvement in clinical outcomes with the addition of targeted agents. To increase the accessibility of our screening method and accelerate the pace at which novel combinations with CRT are identified and incorporated into standard practices for treatments, we report details on screening method optimization, data generation, and downstream data analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications

We developed a picosecond photodetector based on our Bridgman-grown and specially engineered cadmium magnesium telluride (Cd 1–x MgxTe) single crystal that is sensitive to both optical and X-ray pulses for coarse timing in free-electron laser applications. Cd 1–x MgxTe is a widebandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and X-ray crosscorrelation, the material must have a very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have a very low bulk leakage current, in the 10–90 nA range for voltages to even 1000 V. Hence, the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1–x MgxTe material are presented. Furthermore, other characterization and transient measurements are discussed along with room-temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Normal Tissue Response of Combined Temporal and Spatial Fractionation in Proton Minibeam Radiation Therapy

Proton minibeam radiation therapy, a spatial fractionation concept, widens the therapeutic window. By reducing normal tissue toxicities, it allows a temporally fractionated regime with high daily doses. However, an array shift between daily fractions can affect the tissue-sparing effect by decreasing the total peak-to-valley dose ratio. Therefore, combining temporal fractions with spatial fractionation raises questions about the impact of daily applied dose modulations, reirradiation accuracies, and total dose modulations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Summary of Factory Fueling and Testing Risks to Support the Transformation of Regulatory Requirements for Microreactors

Microreactors have the potential to open new markets and applications for nuclear energy. New manufacturing and operational regimes, such as factory fueling and testing prior to site installation, are being proposed to meet these new markets. The radiological hazards associated with traditional commercial power reactors are not the same as the hazards of a reactor being constructed in a factory. Currently, a reactor operating license specified under 10 CFR Part 50, Part 52, or (in the near future) Part 53 is required prior to loading fuel in the reactor. This is logical for plants that are immediately to begin full-power operations soon after fuel loading. However, for microreactors, this may not be the case. Some deployment concepts may stage reactors as “ready to go” in a factory prior to site installation and startup. This approach is being considered in the case of diesel generator replacements, mobile or roaming mining operations, and emergency response situations, such as after a major disaster event. Therefore, it is necessary to evaluate hazards assuming low power operation for a short irradiation time. This report investigates the primary hazards unique to microreactors associated with low power reactor and physics tests necessary to confirm core safety assumptions, neutronic and core design performance parameters, and other assumptions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Potential for Midtreatment Albumin-Bilirubin (ALBI) Score to Individualize Liver Stereotactic Body Radiation Therapy

Our individualized functional response adaptive approach to liver stereotactic body radiation therapy (SBRT) with assessment of indocyanine green (ICG) retention at baseline and midtreatment to detect subclinical changes in liver function, permitting dose adjustment, has decreased toxicity while preserving efficacy. We hypothesized that assessment of the albumin-bilirubin (ALBI) score at baseline and midtreatment would allow for more practical identification of patients at risk for treatment-related toxicity (TRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Consequence analyses of sabotage-induced radiological releases in sodium-cooled fast microreactors

Analysis of three sodium-cooled fast microreactors (SFMs) with thermal powers of 10, 30, and 50 MWt showed that smaller reactors result in lower radiological consequences during a postulated sabotage-induced event because of their reduced core inventory. All SFMs used U-10Zr metal fuel enriched to 15 wt% high-assay low-enriched uranium and operated until their respective effective multiplication factor (k eff ) reduced to less than 1 or until the end of their operational lifespan. Sabotage scenarios were simulated at this point, when the fuel inventory within the core contains the highest-level of radioactivity. Radionuclide core inventories were calculated using the SCALE code at shutdown and 3 days post-shutdown. Dose consequence analyses were performed for three sabotage scenarios using the RASCAL tool. As microreactor developers plan for minimal on-site or complete off-site emergency response, it remains essential to evaluate their physical protection needs and potential hazards, including assessing postulated sabotage-induced events that could become more relevant. SFM licensees should identify a credible worst-case, major accident, estimate release source terms, and perform dose consequence analyses to evaluate site-specific physical protection measures. In conclusion, this recommendation supports a risk-informed, performance-based approach, aligning with applicable regulatory requirements, i.e., 10 CFR Parts 100 and 53 rulemaking in the United States.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Physical Sciences Vistas Issue 3 2021

In this issue, highlights of our contributions to mission operations include descriptions of the following. • How exact and scrupulous planning in concert with sophisticated science enabled a first-ever direct measurement of a radionuclide with a half-life as short as six days. The work, which included operations at the Los Alamos Neutron Science Centers (LANSCE) Weapons Neutron Research Facility and the Isotope Production Facility’s hot cell facility, is a boon for both astrophysics and weapons science. • An introduction to Christie Davis and her role in ensuring the Lab’s execution of simultaneous excellence. • A look at progress by AOT’s Target and Experimental Support Team in reclaiming long-dormant space in a radiological controlled area for new work improving target systems for the Lujan Center. • A story showcasing a cross-organizational effort to minimize the directorate’s legacy and environmental footprint. Staff from across the Lab joined together to ensure the safe and efficient disposal of Rocky Flats legacy waste stored in a transportainer at the Target Fabrication Facility. • How the Lab’s Utilities and Infrastructure experts collaborated with stakeholders in our directorate to safety execute preventive maintenance on the LANSCE mesa’s large electrical substation. The Safe Conduct of Research principles provided a common framework for the planning and process. • A description of the resources called upon and the procedures undertaken by MPA to inventory the division’s time-sensitive chemicals, including the careful and conscientious response of an alert team member when something seemed amiss.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Parotid Gland Stem Cell Sparing Radiation Therapy for Patients With Head and Neck Cancer: A Double-Blind Randomized Controlled Trial

Radiation therapy for head and neck cancer frequently leads to salivary gland damage and subsequent xerostomia. The radiation response of the parotid glands of rats, mice, and patients critically depends on dose to parotid gland stem cells, mainly located in the gland's main ducts (stem cell rich [SCR] region). Therefore, this double-blind randomized controlled trial aimed to test the hypothesis that parotid gland stem cell sparing radiation therapy preserves parotid gland function better than currently used whole parotid gland sparing radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Multi-Site Radiation Therapy for Systemic Disease Control

Metastatic cancer is a heterogeneous entity, some of which could benefit from local consolidative radiation therapy (RT). Although randomized evidence is growing in support of using RT for oligometastatic disease, a highly active area of investigation relates to whether RT could benefit patients with polymetastatic disease. This article highlights the preclinical and clinical rationale for using RT for polymetastatic disease, proposes an exploratory framework for selecting patients best suited for these types of treatments, and briefly reviews potential challenges. The goal of this hypothesis-generating review is to address personalized multimodality systemic treatment for patients with metastatic cancer. The rationale for using high-dose RT is primarily for local control and immune activation in either oligometastatic or polymetastatic disease. However, the primary application of low-dose RT is to activate distinct antitumor immune pathways and modulate the tumor stroma in efforts to better facilitate T cell infiltration. We explore clinical cases involving high- and low-dose RT to demonstrate the potential efficacy of such treatment. We then group patients by extent of disease burden to implement high- and/or low-dose RT. Patients with low-volume disease may receive high-dose RT to all sites as part of an oligometastatic paradigm. Subjects with high-volume disease (for whom standard of care remains palliative RT only) could be treated with a combination of high-dose RT to a few sites for immune activation, while receiving low-dose RT to several remaining lesions to enhance systemic responses from high-dose RT and immunotherapy. We further discuss how emerging but speculative concepts such as immune function may be integrated into this approach and examine therapies currently under investigation that may help address immune deficiencies. The review concludes by addressing challenges in using RT for polymetastatic disease, such as concerns about treatment planning workflows, treatment times, dose constraints for multiple-isocenter treatments, and economic considerations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

2025 Review and Revision of Federal Guidance Report 15

Federal Guidance Report No. 15 (FGR 15), External Exposure to Radionuclides in Air, Water and Soil, published in 2019 and referred to below as FGR 2019, provides age-specific effective dose rate coefficients for reference persons externally exposed to each of 1252 radionuclides homogenously distributed in environmental media. Soon after completion of FGR 2019, the International Commission on Radiological Protection (ICRP) published a similar report (ICRP Publication 144, 2020) addressing the same radionuclides and many of the external exposure scenarios addressed in FGR 2019. In 2023 Argonne National Laboratory (ANL) published a review of dose coefficients in FGR 2019, concluding that “The external effective dose from beta radiation is not appropriately accounted for in FGR 15 for both low- and high-energy beta emitters in air, in soil, and on soil surfaces.” That conclusion was based largely on comparisons of dose coefficients in FGR 2019 with values in ICRP Publication 144 but also on consideration of some unexpected patterns of equivalent dose rate coefficients across tissues and of effective dose rate coefficients across different soil depths, for a selected set of low-energy beta emitters. In response to the ANL report, the Center for Radiation Protection Knowledge (CRPK) at Oak Ridge National Laboratory (ORNL) performed an extensive reexamination of the methods and published values of FGR 2019. CRPK found that coding errors had resulted in inaccurate estimates, primarily overestimates, in many of the dose coefficients tabulated in FGR 2019 but that many of the differences between results in FGR 2019 and ICRP Publication 144 could be traced to differences in methodology. CRPK has corrected all errors in FGR 2019 associated with the coding errors and has taken the opportunity to improve a major portion of the remaining dose coefficients in FGR 2019, primarily through additional Monte Carlo calculations resulting in improved statistics for tissue equivalent dose rate coefficients for exposure to monoenergetic sources. This has eliminated the need for extrapolation of results from high and medium energies to low energies, as was done in FGR 2019. In addition, inconsistencies in the methodology identified in the review, such as computational representation of the adult female, were eliminated. The revised effective dose rate coefficients are consistent with values in ICRP Publication 144 except for differences in values clearly arising from differences in methodology; and differences in values for a relatively small set of very low-energy radionuclides with highly uncertain dose coefficients regardless of methodology.

54 ENVIRONMENTAL SCIENCES↗

Radiosensitizing the Vasculature of Primary Brainstem Gliomas Fails to Improve Tumor Response to Radiation Therapy

Diffuse intrinsic pontine gliomas (DIPGs) arise in the pons and are the leading cause of death from brain tumors in children. DIPGs are routinely treated with radiation therapy, which temporarily improves neurological symptoms but generally fails to achieve local control. Because numerous clinical trials have not improved survival from DIPG over standard radiation therapy alone, there is a pressing need to evaluate new therapeutic strategies for this devastating disease. Vascular damage caused by radiation therapy can increase the permeability of tumor blood vessels and promote tumor cell death.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Radiation Dose Rate Monitoring During Prolonged Armed Conflict

The 2022 Russian full-scale invasion of Ukraine has introduced unprecedented challenges for the nuclear power generation and radiological safety communities, including occupation and disturbance of highly-contaminated areas, occupation of a nuclear power plant, and strikes near and within boundaries of nuclear sites. The war has necessitated the implementation of a supplementary dose rate sensor network to provide resilient measurement data for public protection and leadership awareness. This paper discusses the implementation of such a system, the factors determining what equipment is best suited for the purpose, and practical factors regarding deployment of the system and data management. The crucial factors for operating a supplementary dose rate sensing network are backup power and communications options for dose rate sensors to make the network resilient to the effects of military operations. The most important implementation factor is to plan for extended operations beyond those typically considered for emergency response given the unpredictable nature of warfare.

resilience↗

Multicellular Spheroids as In Vitro Models of Oxygen Depletion During FLASH Irradiation

The differential response of normal and tumor tissues to ultrahigh-dose-rate radiation (FLASH) has raised new hope for treating solid tumors but, to date, the mechanism remains elusive. One leading hypothesis is that FLASH radiochemically depletes oxygen from irradiated tissues faster than it is replenished through diffusion. The purpose of this study was to investigate these effects within hypoxic multicellular tumor spheroids through simulations and experiments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Undercooling minimization in ultrasound coupled DTA measurements of molten salts

Molten salts are ionic liquids that are used for the electrolytic pyroprocessing of metals and as heat transfer fluids in very high temperature processes. Recently, halide-based molten salt reactors (MSR) have gained momentum for high density and environmentally responsible electricity generation. The function of these reactors and their fuel cycle depend on a knowledge of the halide salt’s thermodynamic properties [1]. Therefore, high accuracy phase equilibria of MSR relevant base halide and actinide containing salts are needed. Modern thermal analysis of the phase transitions of halide salts is usually done during heating at relatively high scan rates with commercial devices. Normally such measurements are adequate for pure or pseudo-binary salts. However, as the number of components in the mixture increases, accurately resolving the liquidus becomes increasingly difficult. Reversing the scanning mode greatly increases the sensitivity of phase transition measurements but can decrease accuracy due to undercooling [2] — a common occurrence in molten halide systems [3]. This work presents the development of a differential thermal analysis (DTA) cell intended for use in radiological gloveboxes. Non-contact ultrasonic agitation of the halide salt is implemented to limit kinetic limitations on crystallization during cooling to minimize undercooling [4]. Measurements on halide salts are also presented to elucidate the effect of non-contact mixing on undercooling. Reference [1] S. Boyd and C. Taylor, “3 - Chemical fundamentals and applications of molten salts,” in Molten Salt Reactors and Thorium Energy, T. J. Dolan, Ed., Woodhead Publishing, 2017, pp. 29–91. doi: 10.1016/B978-0-08-101126-3.00003-8. [2] K. Nitsch, A. Cihlár, and M. Rodová, “Molten state and supercooling of lead halides,” J. Cryst. Growth, vol. 264, no. 1, pp. 492–498, Mar. 2004, doi: 10.1016/j.jcrysgro.2004.01.011. [3] L. Rycerz, “Practical remarks concerning phase diagrams determination on the basis of differential scanning calorimetry measurements,” J. Therm. Anal. Calorim., vol. 113, no. 1, pp. 231–238, Jul. 2013, doi: 10.1007/s10973-013-3097-0. [4] Md. H. Zahir, S. A. Mohamed, R. Saidur, and F. A. Al-Sulaiman, “Supercooling of phase-change materials and the techniques used to mitigate the phenomenon,” Appl. Energy, vol. 240, pp. 793–817, Apr. 2019, doi: 10.1016/j.apenergy.2019.02.045.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Activator-doped Hg 2 Br 2 as next generation high performance scintillator for high energy physics research and other scientific and imaging applications

Existing COTS inorganic scintillators all have the characteristic of being very good at certain desirable properties, but not sufficient at other desirable properties for HEP. The demand for suitable scintillators (with regards to both scintillation detector properties and suitable pricing), to be used for modern intensities frontier (Mu2e-II), energy frontier (High luminosity large hadron collider) and future e+e- collider projects (aimed as Higgs bosons factory, such as the International Linear Collider (ILC) and the Future Circular Collider (FCC) are putting even higher challenges on crystal scintillators.In this work, we report the development of a novel high-performance scintillators that can address the issues associated with existing scintillators, the activator doped Hg2Br2. Initial results are very encouraging on the detection of gamma and alpha particles using a solid-state photomultiplier (SSPM). The responses have been stable and repeatable. Hg2Br2 also has many advantages over existing COTS scintillators such as: high density, bright, fast, good energy resolution, no intrinsic radiation, radiation hard and cost-effectiveness. Here, we present here why Hg2Br2 is the next generation scintillator for high energy physics experiments as well as other scientific and imaging applications such as planetary science and medical imaging.

36 MATERIALS SCIENCE↗

Prospective Clinical Investigation of the Efficacy of Combination Radiation Therapy With Immune Checkpoint Inhibition

Immune checkpoint inhibitors (ICIs) lead to durable responses in a subset of patients with cancer, but most patients do not respond to ICI, prompting interest in combining immunotherapy with other therapeutic regimens. Preclinical evidence supports the potential for therapeutic synergy between immunotherapy and radiation therapy through modulation of the tumor microenvironment and antitumor immune responses. Local therapy also has the potential to overcome localized sites of relative immune suppression and resistance. Prospective clinical trials have been initiated to test these hypotheses in the clinic as well as to investigate the toxicities and adverse events associated with combination immunotherapy and radiation therapy. In this review, we discuss the emerging results from prospective clinical trials of combination immunotherapy and radiation therapy, the safety and efficacy of their combination, concordance with preclinical and retrospective data, and some of the remaining open questions to be addressed by future clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Pneumonitis and Outcomes After Mediastinal Proton Therapy for Relapsed/Refractory Lymphoma: A PTCOG and PCG Collaboration

Despite high response rates, there has been reluctance to use radiation therapy for patients with relapsed/refractory (r/r) Hodgkin (HL) or aggressive non-Hodgkin lymphoma (NHL) given concerns for subacute and late toxicities. Symptomatic pneumonitis, a subacute toxicity, has an incidence of 17% to 24% (≥grade 2) even with intensity modulated radiation therapy. Proton therapy (PT), which has no exit radiation dose, is associated with a lower dose to lung compared with other radiation techniques. As risk of radiation pneumonitis is associated with lung dose, we evaluated whether pneumonitis rates are lower with PT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗