Search NASA⌕ Search

SEARCH · Search NASA

Results for “Recording systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Use of TV in space science activities - Some considerations

Advantages in the use of TV on board satellites as the primary data-recording system in a manned space laboratory when certain types of experiments are flown are indicated. Real-time or near-real-time validation, elimination of film weight, improved depth of field and low-light sensitivity, and better adaptability to computer and electronic processing of data are spelled out as advantages of TV over photographic techniques, say, in fluid dynamics experiments, and weightlessness studies.

Bannister, T. C.↗

Two measures of performance in a peg-in-hole manipulation task with force feedback

The results are described from two manipulators on a peg-in-hole task, which is part of a continued effort to develop models for human performance with remote manipulators. Task difficulty is varied by changing the diameter of the peg to be inserted in a 50 mm diameter hole. An automatic measuring system records the distance between the tool being held by the manipulator and the receptacle into which it is to be inserted. The data from repeated insertions are processed by computer to determine task times, accumulated distances, and trajectories. Experiments with both the MA-11 cable-connected master-slave manipulator common to hot cell work and the MA-23 servo-controlled manipulator (with and without force feedback) are described. Comparison of these results with previous results of the Ames Manipulator shows that force feedback provides a consistent advantage.

Hill, J. W.↗

Data reduction and performance determination

Definitions, algorithms, and procedures for the reduction of monopropellant thruster measurements to performance parameters are provided. A brief discussion of acquisition and recording systems is also included. Emphasis is placed upon monopropellant hydrazine engines, and some parameters relate specifically to the catalytic decomposition of hydrazine (e.g., percent ammonia dissociation). Performance of other types of monopropellant thrusters may, however, be determined by using procedures similar to those discussed. Two appendixes are included: (1) theoretical performance of monopropellant hydrazine; and (2) calculation of rotational performance.

Source record↗

A flight investigation of blade section aerodynamics for a helicopter main rotor having NLR-1T airfoil sections

A flight investigation was conducted using a teetering-rotor AH-1G helicopter to obtain data on the aerodynamic behavior of main-rotor blades with the NLR-1T blade section. The data system recorded blade-section aerodynamic pressures at 90 percent rotor radius as well as vehicle flight state, performance, and loads. The test envelope included hover, forward flight, and collective-fixed maneuvers. Data were obtained on apparent blade-vortex interactions, negative lift on the advancing blade in high-speed flight and wake interactions in hover. In many cases, good agreement was achieved between chordwise pressure distributions predicted by airfoil theory and flight data with no apparent indications of blade-vortex interactions.

Morris, C. E. K., Jr.↗

Use of a digital tone extractor for real-time phase analysis

A digital tone extractor which monitors the phase integrity of a VLBI recording system in real time was developed. The digital tone extractor monitors phase calibrator tones injected at the antenna and tracks their phase as a function of time. It is capable of maintaining 0.001 cycle phase accuracy over the course of a VLBI experiment in accordance with the accuracy requirements of centimeter VLBI work. This real time VLBI system monitor is a safeguard against most instrumental breakdowns and operator errors.

Sigman, E.↗

Digital recording acquisition subsystem for radio interferometry applications implementation plan

The digital recording acquisition subsystem (DRAS) is a wideband digital recording system that can accommodate data sample rates from 0.125 to 8 MHz in binary increments. The implementation of the DRAS for radio interferometry applications in support of the Crustal Dynamics Project is described. The functional and performance characteristics of the equipment and the key aspects of the implementation plan are discussed.

Kapoor, V. B.↗

Flight evaluation of a simplified gross thrust calculation technique using an F100 turbofan engine in an F-15 airplane

A simplified gross thrust calculation technique was evaluated in flight tests on an F-15 aircraft using prototype F100-PW-100 engines. The technique relies on afterburner duct pressure measurements and empirical corrections to an ideal one-dimensional analysis to determine thrust. In-flight gross thrust calculated by the simplified method is compared to gross thrust calculated by the engine manufacturer's gas generator model. The evaluation was conducted at Mach numbers from 0.6 to 1.5 and at altitudes from 6000 meters to 13,700 meters. The flight evaluation shows that the simplified gross thrust method and the gas generator method agreed within plus or minus 3 percent. The discrepancies between the data generally fell within an uncertainty band derived from instrumentation errors and recording system resolution.

Kurtenbach, F. J.↗

Images of single X-ray photons from X-ray phosphor screens

Photographs show the efficiency and resolution characteristics of single X-ray photons converted to optical photons in a variety of commercial X-ray phosphor screens. The recording system uses a cooled, two-stage image intensifier system with fiber optics coupling to the phosphor screen. High efficiencies in the energy range 20-100 keV with position resolution of the order 200 microns are readily achievable, although the sensitive area is presently limited. Potential applications include X-ray astronomy, high-speed X-ray diffractometry, and extremely low dose radiography.

Fishman, G. J.↗

Evaluation of ERIM optically processed SEASAT SAR data

The results of three studies on the radiometric and geometric properties of optically processed SEASAT SAR imagery are summarized. The accuracy with which the image scale can be predicted based upon a knowledge of the SAR platform and recording system parameters and the processor characteristics was evaluated. The considerations involved in making radiometric measurements from image films, the use of point targets for calibrating the effects of Doppler spectrum shifts on the radiometric calibration of the SAR image data over extended swath lengths was evaluated

Shuchman, R. A.↗

Gravito-inertial sensitivity of the spider - Araneus sericatus

The gravito-inertial transfer function of the orb-weaving spider was evaluated by changes in the cardiac reflex. A non-intrusive method, using a laser system recorded the cardiac pulse. Between 1.001 and 1.5 Gz the data are 'best-fit' by a log function (r-squared 0.92). The response of the neurogenic heart is seen to be a good dependent variable for invetebrate research. The arachnid lyriform organ has those qualities which complement the obtained gravity function. It is hypothesized that the cardiac pump maintains the spiders equilibrium in the gravito-inertial field.

Finck, A.↗

Holographic data storage crystals for LDEF (A0044)

Electro-optic holographic recording systems were developed. The spaceworthiness of electro-optic crystals for use in ultrahigh capacity space data storage and retrieval systems are examined. The crystals for this experiment are included with the various electro-optical components of LDEF experiment. The effects of long-duration exposure on active optical system components is investigated. The concept of data storage in an optical-phase holographic memory is illustrated.

Callen, W. R.↗

Operational radio interferometry observation network (ORION) mobile VLBI station

The design and current status of the ORION mobile VLBI station is described. The station consists of a five-meter antenna, a receiving and recording system installed in a mobile antenna transporter, and an electronics transporter. The station is designed for field operation by a two-person crew at the rate of two sites per week. The various subsystems are described in detail, including the antenna, housing facilities for electronics and crew, microwave equipment, receiver, data acquisition subsystem, frequency and timing subsystem, phase calibration, monitoring and control, water vapor radiometer, and communications.

Renzetti, N. A.↗

Radio stars - A possible link between the Hipparcos optical reference frame and an extra-galactic very long baseline interferometry reference frame

The concept of typing the Hipparcos optical and the JPL VLBI frames of reference by means of VLBI measurements of the positions and proper motions of the radio components of some bright stars is considered. The properties of the thermal and non-thermal radio-stars are discussed and 22 candidate stars are selected to achieve this tie. A description is given of the first VLBI attempt to detect these stars on the intercontinental baselines of the Deep Space Network with the Mark II recording system.

Lestrade, J.-F.↗

Merits of supplemental ground-based measurements of lightning electric fields in the interpretation of airborne measurements

Calculations are presented which indicate that airborne recordings of the electric fields from lightning will be difficult to interpret without correlated continuous broadband electric field measurements at a ground-based station. Furthermore, through application of the results in Master et al. (1981), field measurements made at altitudes above ground may be calibrated by comparison with ground-based measurements of the same discharge. The requirements of the electric-field recording systems sufficient for identification, characterization, and calibration of airborne field measurements are discussed.

Beasley, W. H.↗

Mass analysis of neutral particles and ions released during electrical breakdowns on spacecraft surfaces

Charged-particle fluxes from breakdown events were studied. Methods to measure mass spectra and total emitted flux of neutral particles were developed. The design and construction of the specialized mass spectrometer was completed. Electrical breakdowns were initiated by a movable blunt contact touching the insulating surface. The contact discharge apparatus was used for final development of two different high-speed recording systems and for measurements of the composition of the materials given off by the discharge. It was shown that intense instantaneous fluxes of neutral particles were released from the sites of electrical breakdown events. A laser micropulse mass analyzer showed that visible discoloration at breakdown sites were correllated with the presence of iron on the polymer side of the film, presumably caused by punch-through to the Inconel backing. Kapton samples irradiated by an oxygen ion beam were tested. The irradiated samples were free of surface hydrocarbon contamination but otherwise behaved in the same way as the Kapton samples tested earlier. Only the two samples exposed to oxygen ion bombardment were relatively clean. This indicates an additional variable that should be considered when testing spacecraft materials in the laboratory.

Kendall, B. R. F.↗

Observation of hard X-rays from the Crab pulsar and A0535+26

The Crab pulsar PSR0531+21 was observed in a balloon flight from the Xianghe Balloon Station (China). Data were obtained in the range 20 to 200 keV with a poswish hard X-ray telescope which comprised a 150 sq cm primary crystal of 5 mm thick CsI(T1) which actively shielded the lower 2 pi steradians by a 5 cm thick NaI(T1) crystal. The scintillation pulses originating in CsI and NaI crystals are distinguished by pulse shape discrimination. The telescope has a field of view of approximately 4 deg H psi H pi determined by graded shield and collimator. The effective geometric area of the detector is 116 sq cm. It is noted that when folding a data flow on a long period interference from the data acquisition, transmission and recording system considerably affect the result.

Wu, M.↗

Fracture morphology of 2-D carbon-carbon composition

Out-of-plane tensile tests of a woven fabric carbon-carbon composite were performed in a scanning electron microscope equipped with a tensile stage and a videotape recording system. The composite was prepared from T-300 8-harness satin graphite fabric and a phenolic resin. The (0/90/0/90/0 sub 1/2) sub 2 laminate, with a Theta describing the orientation of the warp fibers of the fabric, was cured at 160 C and pyrolized at 871 C. This was followed by four cycles of resin impregnation, curing, and pyrolysis. A micrograph of the cross section of the composite is presented. Inspection of the specimen fracture surface revealed that the filaments had no residual matrix bonded to them. Further inspection revealed that the fracture was interlaminar in nature. Failure occurred where filaments of adjacent plies had the same orientation. Thus it is postulated that improvement in transverse tensile strength of 2-D carbon-carbon depends on the improvement of the filament-matrix bond strength.

Avery, W. B.↗

Application of laser-velocimetry to the study of the flow around a two-dimensional airfoil

The experimental techniques employed by NASA researchers to obtain a high volume throughput of data in a study of high-lift multielement airfoils using a laser velocimeter (LV) are detailed. The two-dimensional LV system recorded mean velocity, turbulence intensities, Re shear stresses, skewness and kurtosis of the flow. A computer-controlled positioning mount for the LV allowed automated surveys of the flows with a 0.001 in. positioning accuracy. The flow was seeded with oil droplets and additional refinement of the wind tunnel controls permitted rapid speedup at selected areas of the flowfield over specific regions of the airfoil. Surface pressure taps furnished data for selecting regions for more detailed investigation. The data processing capabilities processed 30-40 samples every 10 min in an automated mode. Profiles of the data were computed automatically to furnish graphical displays on demand. Numerous samples of the data displays generated are provided.

Braden, J. A.↗