Search NASA⌕ Search

SEARCH · Search NASA

Results for “Recording systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Images of single X-ray photons from X-ray phosphor screens

Photographs show the efficiency and resolution characteristics of single X-ray photons converted to optical photons in a variety of commercial X-ray phosphor screens. The recording system uses a cooled, two-stage image intensifier system with fiber optics coupling to the phosphor screen. High efficiencies in the energy range 20-100 keV with position resolution of the order 200 microns are readily achievable, although the sensitive area is presently limited. Potential applications include X-ray astronomy, high-speed X-ray diffractometry, and extremely low dose radiography.

Fishman, G. J.↗

Evaluation of ERIM optically processed SEASAT SAR data

The results of three studies on the radiometric and geometric properties of optically processed SEASAT SAR imagery are summarized. The accuracy with which the image scale can be predicted based upon a knowledge of the SAR platform and recording system parameters and the processor characteristics was evaluated. The considerations involved in making radiometric measurements from image films, the use of point targets for calibrating the effects of Doppler spectrum shifts on the radiometric calibration of the SAR image data over extended swath lengths was evaluated

Shuchman, R. A.↗

Gravito-inertial sensitivity of the spider - Araneus sericatus

The gravito-inertial transfer function of the orb-weaving spider was evaluated by changes in the cardiac reflex. A non-intrusive method, using a laser system recorded the cardiac pulse. Between 1.001 and 1.5 Gz the data are 'best-fit' by a log function (r-squared 0.92). The response of the neurogenic heart is seen to be a good dependent variable for invetebrate research. The arachnid lyriform organ has those qualities which complement the obtained gravity function. It is hypothesized that the cardiac pump maintains the spiders equilibrium in the gravito-inertial field.

Finck, A.↗

Holographic data storage crystals for LDEF (A0044)

Electro-optic holographic recording systems were developed. The spaceworthiness of electro-optic crystals for use in ultrahigh capacity space data storage and retrieval systems are examined. The crystals for this experiment are included with the various electro-optical components of LDEF experiment. The effects of long-duration exposure on active optical system components is investigated. The concept of data storage in an optical-phase holographic memory is illustrated.

Callen, W. R.↗

Operational radio interferometry observation network (ORION) mobile VLBI station

The design and current status of the ORION mobile VLBI station is described. The station consists of a five-meter antenna, a receiving and recording system installed in a mobile antenna transporter, and an electronics transporter. The station is designed for field operation by a two-person crew at the rate of two sites per week. The various subsystems are described in detail, including the antenna, housing facilities for electronics and crew, microwave equipment, receiver, data acquisition subsystem, frequency and timing subsystem, phase calibration, monitoring and control, water vapor radiometer, and communications.

Renzetti, N. A.↗

Radio stars - A possible link between the Hipparcos optical reference frame and an extra-galactic very long baseline interferometry reference frame

The concept of typing the Hipparcos optical and the JPL VLBI frames of reference by means of VLBI measurements of the positions and proper motions of the radio components of some bright stars is considered. The properties of the thermal and non-thermal radio-stars are discussed and 22 candidate stars are selected to achieve this tie. A description is given of the first VLBI attempt to detect these stars on the intercontinental baselines of the Deep Space Network with the Mark II recording system.

Lestrade, J.-F.↗

Merits of supplemental ground-based measurements of lightning electric fields in the interpretation of airborne measurements

Calculations are presented which indicate that airborne recordings of the electric fields from lightning will be difficult to interpret without correlated continuous broadband electric field measurements at a ground-based station. Furthermore, through application of the results in Master et al. (1981), field measurements made at altitudes above ground may be calibrated by comparison with ground-based measurements of the same discharge. The requirements of the electric-field recording systems sufficient for identification, characterization, and calibration of airborne field measurements are discussed.

Beasley, W. H.↗

Mass analysis of neutral particles and ions released during electrical breakdowns on spacecraft surfaces

Charged-particle fluxes from breakdown events were studied. Methods to measure mass spectra and total emitted flux of neutral particles were developed. The design and construction of the specialized mass spectrometer was completed. Electrical breakdowns were initiated by a movable blunt contact touching the insulating surface. The contact discharge apparatus was used for final development of two different high-speed recording systems and for measurements of the composition of the materials given off by the discharge. It was shown that intense instantaneous fluxes of neutral particles were released from the sites of electrical breakdown events. A laser micropulse mass analyzer showed that visible discoloration at breakdown sites were correllated with the presence of iron on the polymer side of the film, presumably caused by punch-through to the Inconel backing. Kapton samples irradiated by an oxygen ion beam were tested. The irradiated samples were free of surface hydrocarbon contamination but otherwise behaved in the same way as the Kapton samples tested earlier. Only the two samples exposed to oxygen ion bombardment were relatively clean. This indicates an additional variable that should be considered when testing spacecraft materials in the laboratory.

Kendall, B. R. F.↗

Observation of hard X-rays from the Crab pulsar and A0535+26

The Crab pulsar PSR0531+21 was observed in a balloon flight from the Xianghe Balloon Station (China). Data were obtained in the range 20 to 200 keV with a poswish hard X-ray telescope which comprised a 150 sq cm primary crystal of 5 mm thick CsI(T1) which actively shielded the lower 2 pi steradians by a 5 cm thick NaI(T1) crystal. The scintillation pulses originating in CsI and NaI crystals are distinguished by pulse shape discrimination. The telescope has a field of view of approximately 4 deg H psi H pi determined by graded shield and collimator. The effective geometric area of the detector is 116 sq cm. It is noted that when folding a data flow on a long period interference from the data acquisition, transmission and recording system considerably affect the result.

Wu, M.↗

Fracture morphology of 2-D carbon-carbon composition

Out-of-plane tensile tests of a woven fabric carbon-carbon composite were performed in a scanning electron microscope equipped with a tensile stage and a videotape recording system. The composite was prepared from T-300 8-harness satin graphite fabric and a phenolic resin. The (0/90/0/90/0 sub 1/2) sub 2 laminate, with a Theta describing the orientation of the warp fibers of the fabric, was cured at 160 C and pyrolized at 871 C. This was followed by four cycles of resin impregnation, curing, and pyrolysis. A micrograph of the cross section of the composite is presented. Inspection of the specimen fracture surface revealed that the filaments had no residual matrix bonded to them. Further inspection revealed that the fracture was interlaminar in nature. Failure occurred where filaments of adjacent plies had the same orientation. Thus it is postulated that improvement in transverse tensile strength of 2-D carbon-carbon depends on the improvement of the filament-matrix bond strength.

Avery, W. B.↗

Application of laser-velocimetry to the study of the flow around a two-dimensional airfoil

The experimental techniques employed by NASA researchers to obtain a high volume throughput of data in a study of high-lift multielement airfoils using a laser velocimeter (LV) are detailed. The two-dimensional LV system recorded mean velocity, turbulence intensities, Re shear stresses, skewness and kurtosis of the flow. A computer-controlled positioning mount for the LV allowed automated surveys of the flows with a 0.001 in. positioning accuracy. The flow was seeded with oil droplets and additional refinement of the wind tunnel controls permitted rapid speedup at selected areas of the flowfield over specific regions of the airfoil. Surface pressure taps furnished data for selecting regions for more detailed investigation. The data processing capabilities processed 30-40 samples every 10 min in an automated mode. Profiles of the data were computed automatically to furnish graphical displays on demand. Numerous samples of the data displays generated are provided.

Braden, J. A.↗

High speed photography, videography, and photonics III; Proceedings of the Meeting, San Diego, CA, August 22, 23, 1985

Papers are presented on the picosecond electronic framing camera, photogrammetric techniques using high-speed cineradiography, picosecond semiconductor lasers for characterizing high-speed image shutters, the measurement of dynamic strain by high-speed moire photography, the fast framing camera with independent frame adjustments, design considerations for a data recording system, and nanosecond optical shutters. Consideration is given to boundary-layer transition detectors, holographic imaging, laser holographic interferometry in wind tunnels, heterodyne holographic interferometry, a multispectral video imaging and analysis system, a gated intensified camera, a charge-injection-device profile camera, a gated silicon-intensified-target streak tube and nanosecond-gated photoemissive shutter tubes. Topics discussed include high time-space resolved photography of lasers, time-resolved X-ray spectrographic instrumentation for laser studies, a time-resolving X-ray spectrometer, a femtosecond streak camera, streak tubes and cameras, and a short pulse X-ray diagnostic development facility.

Ponseggi, B. G.↗

The amplitude spectra of lightning radiation fields in the interval from 1 to 20 MHz

Amplitude spectra of the fast-rising initial portion of the EM fields produced by return strokes, leader steps, and cloud pulse are presented. These data have been derived from ground-based measurements of dE/dt signatures that were recorded in the time domain on a triggered oscilloscope. The spectral amplitudes of first return strokes match previously published data at 1 MHz and decrease with increasing frequency, as 1/f between 1 and about 6 MHz and as 1/f squared between 6 and 20 MHz. The spectral amplitudes of leader steps just before return strokes and the fast portion of cloud pulses that triggered the recording system tend to lie 5 to 10 dB below the amplitudes of first return strokes over the entire frequency interval.

Weidman, C. D.↗

A ten-element array of individually addressable channeled-substrate-planar AlGaAs diode lasers

The fabrication of arrays of channeled-substrate-planar (CSP) AlGaAs diode lasers which emit up to 150 mW CW in a single spatial mode and are applicable to mulitchannel optical recording systems is described. The CSP diode lasers are incorporated in ten-array geometry, and each array is 1.95 nm in width and 100 microns in thickness and is cleaved to have a cavity length of 200 microns and coated to produce 90-percent reflectivity on the back facet and 10-percent reflectivity on the front facet. The array is attached to a thermoelectrically cooled submount. The optical output power versus input current characteristics for the array are evaluated, and the lateral far-field intensity profiles for each of the lasers (at 30 mW CW) and CW spectra of the lasers are analyzed.

Carlin, D. B.↗

Observation of an ionospheric disturbance caused by a gamma-ray burst

A first observation of an ionospheric disturbance from a gamma-ray burst is reported. The burst, GB30801, occurred at 22:14:18 UT on August 1, 1983, and was one of the strongest ever observed. The total fluence was 0.002 erg/sq cm, most of which occurred in the first 4 s of the burst. Simultaneously, a change was observed in the amplitude of a VLF radio signal from a transmitter in Rugby, England indicative of an ionospheric disturbance. Weaker disturbances were also recorded at the same receiving site on signals from VLF stations in Annapolis, Maryland and Lualualei, Hawaii. The times of the burst and the disturbances are coincident within the 10-s resolution of the VLF recording system. No similar disturbances were observed within 60 hr around the time of the burst. In the future, a network of VLF burst monitors may provide measurements of the total ionizing energy fluence from a burst, as well as some limited directional information.

Fishman, G. J.↗

History at NASA

The efforts of the National Aeronautics and Space Administration to capture and record the events of the past are described, particularly the research accomplishments of NASA's agency-wide history program. A concise guide to the historical research resources available at NASA Headquarters in Washington, D.C., at NASA facilities around the country, and through the federal records systems is given.

Source record↗

Simplified Correction Of Errors In Reed-Solomon Codes

New decoder realized by simplified pipeline architecture. Simplified procedure for correction of errors and erasures in Reed-Solomon codes expected to result in simpler decoding equipment. Development widens commercial applicability of Reed-Solomon codes, used to correct bursts of errors in digital communication and recording systems. Improved decoder less complex. Made more regular, simple, and suitable for implementation in both VLSI and software.

Truong, T. K.↗