Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reproducibility of Results”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Glucose determination in human aqueous humor with Raman spectroscopy

It has been suggested that spectroscopic analysis of the aqueous humor of the eye could be used to indirectly predict blood glucose levels in diabetics noninvasively. We have been investigating this potential using Raman spectroscopy in combination with partial least squares (PLS) analysis. We have determined that glucose at clinically relevant concentrations can be accurately predicted in human aqueous humor in vitro using a PLS model based on artificial aqueous humor. We have further determined that with proper instrument design, the light energy necessary to achieve clinically acceptable prediction of glucose does not damage the retinas of rabbits and can be delivered at powers below internationally acceptable safety limits. Herein we summarize our current results and address our strategies to improve instrument design. 2005 Society of Photo-Optical Instrumentation Engineers.

Spectrum Analysis, Raman/methods↗

Embracing Open Source for NASA's Earth Science Data Systems

The overarching purpose of NASAs Earth Science program is to develop a scientific understanding of Earth as a system. Scientific knowledge is most robust and actionable when resulting from transparent, traceable, and reproducible methods. Reproducibility includes open access to the data as well as the software used to arrive at results. Additionally, software that is custom-developed for NASA should be open to the greatest degree possible, to enable re-use across Federal agencies, reduce overall costs to the government, remove barriers to innovation, and promote consistency through the use of uniform standards. Finally, Open Source Software (OSS) practices facilitate collaboration between agencies and the private sector. To best meet these ends, NASAs Earth Science Division promotes the full and open sharing of not only all data, metadata, products, information, documentation, models, images, and research results but also the source code used to generate, manipulate and analyze them. This talk focuses on the challenges to open sourcing NASA developed software within ESD and the growing pains associated with establishing policies running the gamut of tracking issues, properly documenting build processes, engaging the open source community, maintaining internal compliance, and accepting contributions from external sources. This talk also covers the adoption of existing open source technologies and standards to enhance our custom solutions and our contributions back to the community. Finally, we will be introducing the most recent OSS contributions from NASA Earth Science program and promoting these projects for wider community review and adoption.

Earth Science↗

Magnetorotational iron core collapse

During its final evolutionary stages, a massive star, as considered in current astrophysical theory, undergoes rapid collapse, thereby triggering a sequence of a catastrophic event which results in a Type II supernova explosion. A remnant neutron star or a black hole is left after the explosion. Stellar collapse occurs, when thermonuclear fusion has consumed the lighter elements present. At this stage, the core consists of iron. Difficulties arise regarding an appropriate model with respect to the core collapse. The present investigation is concerned with the evolution of a Type II supernova core including the effects of rotation and magnetic fields. A simple neutrino model is developed which reproduced the spherically symmetric results of Bowers and Wilson (1982). Several two-dimensional computational models of stellar collapse are studied, taking into account a case in which a 15 solar masses iron core was artificially given rotational and magnetic energy.

Symbalisty, E. M. D.↗

Effects of chair restraint on the strength of the tibia in rhesus monkeys

To determine the effects of the relative inactivity and unloading on the strength of the tibias of monkeys, Macaca mulatta, we used a non-invasive test to measure bending stiffness, or EI (Nm2), a mechanical property. The technique was validated by comparisons of in vivo measurements with standard measures of EI in the same bones post-mortem (r2 = 0.95, P < 0.0001). Inter-test precision was 4.28+/-1.4%. Normative data in 24 monkeys, 3.0+/-0.7 years and 3.6+/-0.6 kg, revealed EI to be 16% higher in the right than left tibia (4.4+/-1.6 vs. 3.7+/-1.6 Nm2, P < 0.05). Five monkeys, restrained in chairs for 14 days, showed decreases in EI. There were no changes in EI in two chaired monkeys that lost weight during a 2-week space flight. The factors that account for both the decreases in bone mechanical properties after chair restraint at 1 g and lack of change after microgravity remain to be identified. Metabolic factors associated with body weight changes are suggested by our results.

NASA Discipline Musculoskeletal↗

Equally parsimonious pathways through an RNA sequence space are not equally likely

An experimental system for determining the potential ability of sequences resembling 5S ribosomal RNA (rRNA) to perform as functional 5S rRNAs in vivo in the Escherichia coli cellular environment was devised previously. Presumably, the only 5S rRNA sequences that would have been fixed by ancestral populations are ones that were functionally valid, and hence the actual historical paths taken through RNA sequence space during 5S rRNA evolution would have most likely utilized valid sequences. Herein, we examine the potential validity of all sequence intermediates along alternative equally parsimonious trajectories through RNA sequence space which connect two pairs of sequences that had previously been shown to behave as valid 5S rRNAs in E. coli. The first trajectory requires a total of four changes. The 14 sequence intermediates provide 24 apparently equally parsimonious paths by which the transition could occur. The second trajectory involves three changes, six intermediate sequences, and six potentially equally parsimonious paths. In total, only eight of the 20 sequence intermediates were found to be clearly invalid. As a consequence of the position of these invalid intermediates in the sequence space, seven of the 30 possible paths consisted of exclusively valid sequences. In several cases, the apparent validity/invalidity of the intermediate sequences could not be anticipated on the basis of current knowledge of the 5S rRNA structure. This suggests that the interdependencies in RNA sequence space may be more complex than currently appreciated. If ancestral sequences predicted by parsimony are to be regarded as actual historical sequences, then the present results would suggest that they should also satisfy a validity requirement and that, in at least limited cases, this conjecture can be tested experimentally.

NASA Discipline Exobiology↗

Enabling computer decisions based on EEG input

Multilayer neural networks were successfully trained to classify segments of 12-channel electroencephalogram (EEG) data into one of five classes corresponding to five cognitive tasks performed by a subject. Independent component analysis (ICA) was used to segregate obvious artifact EEG components from other sources, and a frequency-band representation was used to represent the sources computed by ICA. Examples of results include an 85% accuracy rate on differentiation between two tasks, using a segment of EEG only 0.05 s long and a 95% accuracy rate using a 0.5-s-long segment.

Validation Studies↗

Self-motion perception: assessment by computer-generated animations

The goal of this research is more precise description of adaptation to sensory rearrangements, including microgravity, by development of improved procedures for assessing spatial orientation perception. Thirty-six subjects reported perceived self-motion following exposure to complex inertial-visual motion. Twelve subjects were assigned to each of 3 perceptual reporting procedures: (a) animation movie selection, (b) written report selection and (c) verbal report generation. The question addressed was: do reports produced by these procedures differ with respect to complexity and reliability? Following repeated (within-day and across-day) exposures to 4 different "motion profiles," subjects either (a) selected movies presented on a laptop computer, or (b) selected written descriptions from a booklet, or (c) generated self-motion verbal descriptions that corresponded most closely with their motion experience. One "complexity" and 2 reliability "scores" were calculated. Contrary to expectations, reliability and complexity scores were essentially equivalent for the animation movie selection and written report selection procedures. Verbal report generation subjects exhibited less complexity than did subjects in the other conditions and their reports were often ambiguous. The results suggest that, when selecting from carefully written descriptions and following appropriate training, people may be better able to describe their self-motion experience with words than is usually believed.

Non-NASA Center↗

Bridging the Gap: Enhancing Prominence and Provenance of NASA Datasets in Research Publications

Attribution of datasets that were used to generate research results described in peer-reviewed publications to the original source of these datasets (which are often archived at NASA Earth Science data centers) has been very challenging. Even though the data citation standard of citing datasets as research artifacts and citing them with Digital Object Identifiers (DOIs) was introduced over a decade ago, most authors do not properly reference the data used in their studies and merely mention them in the text. The lack of proper citations of datasets makes the peer-reviewed publication less transparent, imperils reproducibility, and impedes open science. We offer an open-source publication management methodology and a tool that can help to enhance usage-based data discovery, prominence, and provenance of the data; reproducibility of the research results; and potentially increase the return on investment on NASA-funded research.

open-source↗

Brain segmentation and the generation of cortical surfaces

This paper describes methods for white matter segmentation in brain images and the generation of cortical surfaces from the segmentations. We have developed a system that allows a user to start with a brain volume, obtained by modalities such as MRI or cryosection, and constructs a complete digital representation of the cortical surface. The methodology consists of three basic components: local parametric modeling and Bayesian segmentation; surface generation and local quadratic coordinate fitting; and surface editing. Segmentations are computed by parametrically fitting known density functions to the histogram of the image using the expectation maximization algorithm [DLR77]. The parametric fits are obtained locally rather than globally over the whole volume to overcome local variations in gray levels. To represent the boundary of the gray and white matter we use triangulated meshes generated using isosurface generation algorithms [GH95]. A complete system of local parametric quadratic charts [JWM+95] is superimposed on the triangulated graph to facilitate smoothing and geodesic curve tracking. Algorithms for surface editing include extraction of the largest closed surface. Results for several macaque brains are presented comparing automated and hand surface generation. Copyright 1999 Academic Press.

NASA Discipline Neuroscience↗

Developing a Vision for Maturing the Heliophysics Infrastructure towards Open Science: The DIARieS Analysis Ecosystem

In the dawn of open science and the upcoming requirements, we speak about the existing state of Heliophysics infrastructure and detail the evolution required to address capability or interconnection shortcomings. Such a daunting barrier calls for an analysis ecosystem with multi-faceted capability. We propose such an ecosystem, called DIARieS, to be built upon five conceptual pillars: Discovery, Implementation, Analysis, Reproducibility, and Sharing of results. The combination of these concepts in a single platform will enable users to more intuitively combine recent advances in technology to create ‘DIARieS’ of their workflows, which can be easily made open to others in the community. The DIARieS ecosystem will also increase our efficiency by streamlining our various workflow processes, including automatic incorporation of the impending requirements of open science. The various components of the ecosystem will simplify software installation and data implementation, including automatically generated citation lists based on the components included. Automatic containerization and version control of the ecosystem will make the custom workflows easily reproducible. Employing widget technology will ease the difficulty of producing publication and commercial quality visualizations and applying common analyses techniques. Incorporating multiple technologies will streamline the various sharing methods common in our work environments today. Overall, the totality of capabilities to be offered by this analysis ecosystem will drastically simplify the application of open science principles to our work in addition to improving our efficiency and ease of collaboration. This talk summarizes a vision of the proposed ecosystem, which is described in more detail in Ringuette et al. (2022: https://doi.org/10.1016/j.asr.2022.05.012).

infrastructure↗

Developing a Vision for Maturing the Heliophysics Infrastructure towards Open Science

In the dawn of open science and the upcoming requirements, we speak about the existing state of Heliophysics infrastructure and detail the evolution required to address capability or interconnection shortcomings. Such a daunting barrier calls for an analysis ecosystem with multi-faceted capability. We propose such an ecosystem, called DIARieS, to be built upon five conceptual pillars: Discovery, Implementation, Analysis, Reproducibility, and Sharing of results. The combination of these concepts in a single platform will enable users to more intuitively combine recent advances in technology to create ‘DIARieS’ of their workflows, which can be easily made open to others in the community. The DIARieS ecosystem will also increase our efficiency by streamlining our various workflow processes, including automatic incorporation of the impending requirements of open science. The various components of the ecosystem will simplify software installation and data implementation, including automatically generated citation lists based on the components included. Automatic containerization and version control of the ecosystem will make the custom workflows easily reproducible. Employing widget technology will ease the difficulty of producing publication and commercial quality visualizations and applying common analyses techniques. Incorporating multiple technologies will streamline the various sharing methods common in our work environments today. Overall, the totality of capabilities to be offered by this analysis ecosystem will drastically simplify the application of open science principles to our work in addition to improving our efficiency and ease of collaboration.

Infrastructure↗

Sympathetic restraint of respiratory sinus arrhythmia: implications for vagal-cardiac tone assessment in humans

Clinicians and experimentalists routinely estimate vagal-cardiac nerve traffic from respiratory sinus arrhythmia. However, evidence suggests that sympathetic mechanisms may also modulate respiratory sinus arrhythmia. Our study examined modulation of respiratory sinus arrhythmia by sympathetic outflow. We measured R-R interval spectral power in 10 volunteers that breathed sequentially at 13 frequencies, from 15 to 3 breaths/min, before and after beta-adrenergic blockade. We fitted changes of respiratory frequency R-R interval spectral power with a damped oscillator model: frequency-dependent oscillations with a resonant frequency, generated by driving forces and modified by damping influences. beta-Adrenergic blockade enhanced respiratory sinus arrhythmia at all frequencies (at some, fourfold). The damped oscillator model fit experimental data well (39 of 40 ramps; r = 0.86 +/- 0.02). beta-Adrenergic blockade increased respiratory sinus arrhythmia by amplifying respiration-related driving forces (P < 0.05), without altering resonant frequency or damping influences. Both spectral power data and the damped oscillator model indicate that cardiac sympathetic outflow markedly reduces heart period oscillations at all frequencies. This challenges the notion that respiratory sinus arrhythmia is mediated simply by vagal-cardiac nerve activity. These results have important implications for clinical and experimental estimation of human vagal cardiac tone.

NASA Discipline Cardiopulmonary↗

An information maximization model of eye movements

We propose a sequential information maximization model as a general strategy for programming eye movements. The model reconstructs high-resolution visual information from a sequence of fixations, taking into account the fall-off in resolution from the fovea to the periphery. From this framework we get a simple rule for predicting fixation sequences: after each fixation, fixate next at the location that minimizes uncertainty (maximizes information) about the stimulus. By comparing our model performance to human eye movement data and to predictions from a saliency and random model, we demonstrate that our model is best at predicting fixation locations. Modeling additional biological constraints will improve the prediction of fixation sequences. Our results suggest that information maximization is a useful principle for programming eye movements.

NASA Discipline Neuroscience↗

Method for printing functional protein microarrays

Piezoelectric dispensing of proteins from borosilicate glass capillaries is a popular method of protein biochip fabrication that offers the advantages of sample recovery and noncontact with the printing substrate. However, little regard has been given to the quantitative aspects of dispensing minute volumes (1 nL or less) at the low protein concentrations (20 micrograms/mL or less) typically used in microprinting. Specifically, loss of protein sample due to nonspecific adsorption to the glass surface of the dispensing capillaries can limit the amount of protein delivered to the substrate. We demonstrate the benefits of a low ionic strength buffer containing the carrier protein BSA that effectively minimizes the ionic strength-dependent phenomenon of nonspecific protein adsorption to borosilicate glass. Over the concentration range of 20-2.5 micrograms/mL, the dispensing of a reference IgG in 10 mM PBS including 0.1% BSA resulted in the deposition of 3.6- to 44-fold more IgG compared to the deposition of IgG in standard 150 mM PBS in the absence of BSA. Furthermore, when the IgG was dispensed with carrier protein, the resulting spots exhibited a more uniform morphology. In a direct immunoassay for cholera toxin, capture antibody spots dispensed in 10 mM PBS containing 0.1% BSA produced fluorescent signals that were 2.8- to 4.3-fold more intense than antibody spots that were dispensed in 150 mM PBS without BSA. Interestingly, no differences were observed in the specific activities of the capture antibodies as a result of printing in the different buffers. The implications of these results on the future development of protein biochips are discussed.

Evaluation Studies↗

Effect of optical digitizer selection on the application accuracy of a surgical localization system-a quantitative comparison between the OPTOTRAK and flashpoint tracking systems

Application accuracy is a crucial factor for stereotactic surgical localization systems, in which space digitization camera systems are one of the most critical components. In this study we compared the effect of the OPTOTRAK 3020 space digitization system and the FlashPoint Model 3000 and 5000 3D digitizer systems on the application accuracy for interactive localization of intracranial lesions. A phantom was mounted with several implantable frameless markers which were randomly distributed on its surface. The target point was digitized and the coordinates were recorded and compared with reference points. The differences from the reference points represented the deviation from the "true point." The root mean square (RMS) was calculated to show the differences, and a paired t-test was used to analyze the results. The results with the phantom showed that, for 1-mm sections of CT scans, the RMS was 0.76 +/- 0. 54 mm for the OPTOTRAK system, 1.23 +/- 0.53 mm for the FlashPoint Model 3000 3D digitizer system, and 1.00 +/- 0.42 mm for the FlashPoint Model 5000 system. These preliminary results showed that there is no significant difference between the three tracking systems, and, from the quality point of view, they can all be used for image-guided surgery procedures. Copyright 1999 Wiley-Liss, Inc.

Non-NASA Center↗

Stimulated single fiber electromyography in the mouse: techniques and normative data

As the number of new transgenic mouse models of human neuromuscular disease continues to increase, the development of sophisticated electrophysiologic techniques for assessing the peripheral nervous system in these models has become important. Neuromuscular junction (NMJ) dysfunction, in particular, is often not detectable by morphologic or other techniques. To enable sensitive testing of murine NMJ function, we developed and tested a method for stimulated single fiber electromyography (S-SFEMG) in the gastrocnemius muscles of anesthetized mice. Jitter was assessed by measuring the mean consecutive latency difference (MCD) of single fiber responses to sciatic nerve stimulation at 2 HZ. Mean MCD values in normothermic mice were in the range of 6-8 micros for different strains, with no MCD values exceeding 25 micros. Reduced core temperature (to 29 degrees--30 degrees C) resulted in increased jitter, whereas intubation and mechanical ventilation of mice did not alter these values. Intraperitoneal and intravenous injection of vecuronium, however, resulted in progressively increased jitter followed by blocking in continuously monitored fibers. These observations validate the utility of S-SFEMG in mice as an index of NMJ function under a variety of physiologic conditions, and suggest that a high safety factor for neuromuscular transmission exists at mouse NMJs. Copyright 2001 John Wiley & Sons, Inc.

Non-NASA Center↗

Validity of a heart rate monitor during work in the laboratory and on the Space Shuttle

Accurate heart rate measurement during work is required for many industrial hygiene and ergonomics situations. The purpose of this investigation was to determine the validity of heart rate measurements obtained by a simple, lightweight, commercially available wrist-worn heart rate monitor (HRM) during work (cycle exercise) sessions conducted in the laboratory and also during the particularly challenging work environment of space flight. Three different comparisons were made. The first compared HRM data to simultaneous electrocardiogram (ECG) recordings of varying heart rates that were generated by an ECG simulator. The second compared HRM data to ECG recordings collected during work sessions of 14 subjects in the laboratory. Finally, ECG downlink and HRM data were compared in four astronauts who performed cycle exercise during space flight. The data were analyzed using regression techniques. The results were that the HRM recorded virtually identical heart rates compared with ECG recordings for the data set generated by an ECG simulator. The regression equation for the relationship between ECG versus HRM heart rate data during work in the laboratory was: ECG HR = 0.99 x (HRM) + 0.82 (r2 = 0.99). Finally, the agreement between ECG downlink data and HRM data during space flight was also very high, with the regression equation being: Downlink ECG HR = 1.05 x (HRM) -5.71 (r2 = 0.99). The results of this study indicate that the HRM provides accurate data and may be used to reliably obtain valid data regarding heart rate responses during work.

STS Shuttle Project↗

Localization of needle tip with color doppler during pericardiocentesis: In vitro validation and initial clinical application

This study evaluates a new device that uses color Doppler ultrasonography to enable real-time image guidance of the aspirating needle, which has not been possible until now. The ColorMark device (EchoCath Inc, Princeton, NJ) induces high-frequency, low-amplitude vibrations in the needle to enable localization with color Doppler. We studied this technique in 25 consecutive patients undergoing pericardiocentesis, and in vitro, in a urethane phantom with which the accuracy of color Doppler localization of the needle tip was compared with that obtained by direct measurement. Tip localization was excellent in vitro; errors axial to the ultrasound beam (velocity Doppler -0.13 +/- 0.90 mm, power Doppler -0.05 +/- 1.7 mm) were less than lateral errors (velocity -0.36 +/- 1.8 mm, power -0.02 +/- 2.8 mm). In 18 of 25 patients, the needle was identified and guided into the pericardial space with the ColorMark technique, and it allowed successful, uncomplicated drainage of fluid. Initial failures were the result of incorrect settings on the echocardiographic machine and inappropriate combinations of the needle puncture site and imaging window. This study demonstrates a novel color Doppler technique that is highly accurate at localizing a needle tip. The technique is feasible for guiding pericardiocentesis. Further clinical validation of this technique is required.

NASA Discipline Cardiopulmonary↗