Search NASA⌕ Search

SEARCH · Search NASA

Results for “Return Period”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

50,000 Laps Around Mars: Navigating the Mars Reconnaissance Orbiter Through the Extended Missions (January 2009 - March 2017)

Orbiting Mars since March 2006, the Mars Reconnaissance Orbiter (MRO) spacecraft continues to perform valuable science observations, provide telecommunication relay for surface assets, and characterize landing sites for future missions. Previous papers reported on the navigation of MRO from interplanetary cruise through the end of the Primary Science Phase (PSP) in December 2008 and on maneuvers performed through November 2016. This paper highlights the navigation of MRO from January 2009 through its 50,000th orbit around Mars on March 27, 2017, an eight-year period covering the Extended Science Phase, the first three extended missions, and a portion of the fourth extended mission which began on October 1, 2016. Since the beginning of the PSP in November 2006, MRO’s navigation performance has continued to exceed expectations. Over that period of time, the mission has returned over 300 terabytes of data.

Schulze, William↗

Managing wetlands to solve the water crisis in the Katuma River ecosystem, Tanzania

The formerly perennial Katuma River in western Tanzania starts in a protected forest, it then flows through irrigated rice farms before reaching Lake Katavi, a floodplain wetland whose outflow regulates the river flow through the Katavi National Park (KNP) down to its outlet at Lake Rukwa, which has no outlet. In recent years, due to overexploitation of water for irrigation, the Katuma River dried out for up to four months per year and this greatly degraded the KNP ecosystem, the siltation of river lead to flooding of the adjacent areas during heavy rains, and the water level of Lake Rukwa has decreased by 4 m since 1992 while its fishery yield and water quality also deteriorated. In 2016, a total of 46 illegal weirs were removed from the Katuma River upstream of KNP. Following that, the river zero-flow periods were reduced by two months and Lake Rukwa water level rose by 1 m. We suggest that the construction of a low V-notch weir at the outlet of the Lake Katavi wetlands would further reduce the Katuma River zero-flow periods by an additional month, thus returning the river nearly to its former perennial status. The enforcement of regulations governing the construction of irrigation weirs is essential. These ecohydrology solutions do not eliminate the threats, but they amplify the opportunities for sustainable development at the basin scale. This example of active governance of water resources at the basin scale can be applied throughout Tanzania and in semi-arid East Africa in general.

Satellite altimetry↗

A study of metabolic balance in crewmembers of Skylab IV

A metabolic balance study was conducted on the three crewmembers of the 84-day Skylab IV earth orbital mission. Dietary intake was controlled, monitored, and kept very nearly constant for a period commencing 21 days prior to flight, throughout flight, and for a period of 18 days postflight. Within the first 30 days of flight urine calcium rose to a level approx. 100% above preflight levels and remained elevated for the remainder of the flight. Fecal calcium excretion increased more slowly but continued to accelerate throughout the flight and did not return to baseline levels during the postflight period. Urinary nitrogen increased to 25-30% above preflight levels within one month following launch and thereafter gradually subsided toward control values. The overall losses of calcium averaged approx. 200 mg per day throughout the mission while nitrogen losses averaged 590 mg. Various other indices of musculoskeletal deterioration are discussed and correlated. The parallelism between the effects of weightlessness and bed rest is reviewed. It is noted, that no evidence is yet available as to the identity of the initial biological response to the absence of gravity.

Rambaut, P. C.↗

Simulated Microgravity Increases Cutaneous Blood Flow in the Head and Leg of Humans

The cutaneous micro-circulation vasodilates during acute 6 deg. head-down tilt (HDT, simulated microgravity) relative to upright conditions, more in the lower body than in the upper body. We expected that relative magnitudes of and differences between upper and lower body cutaneous blood flow elevation would be sustained during initial acclimation to simulated microgravity. We measured cutaneous micro-vascular blood flow with laser-Doppler flowmetry at the leg (over the distal tibia) and cheek (over the zygomatic arch) of eight healthy men before, during, and after 24 h of HDT. Results were calculated as a percentage of baseline value (100% measured during pre-tilt upright sitting). Cutaneous blood flow in the cheek increased significantly to 165 +/- 37% (mean + SE, p less than 0.05) at 9-12 h HDT, then returned to near baseline values by 24 h HDT (114 +/- 29%, NSD), despite increased local arterial pressure. Microvascular flow in the leg remained significantly elevated above baseline throughout 24 h HDT (427 +/- 85% at 3 h HDT and 215 +/- 142% at 24 h HDT, p less than 0.05). During the 6-h upright sitting recovery period, cheek and leg blood flow levels returned to near pre-tilt baseline values. Because hydrostatic effects of HDT increase local arterial pressure at the carotid sinus, baroreflex-mediated withdrawal of sympathetic tone probably contributed to increased microvascular flows at the head and leg during HDT. In the leg, baroreflex effects combined with minimal stimulation of local veno-arteriolar and myogenic autoregulatory vasoconstriction to elicit relatively larger and more sustained increases in cutaneous flow during HDT. In the cheek, delayed myogenic vasoconstriction and/or humoral effects apparently compensated for flow elevation by 24 h of HDT. Therefore, localized vascular adaptations to gravity probably explain differences in acclimation of lower and upper body blood flow to HDT and actual microgravity.

Stout, M. Shannon↗

Simulated Microgravity Increases Cutaneous Blood Flow in the Head and Leg of Humans

The cutaneous microcirculation vasodilates during acute 6 degree head-down tilt (HDT, simulated microgravity) relative to upright conditions, more in the lower body than in the upper body. Cutaneous microvascular blood flow was measured with laser-Doppler flowmetry at the leg (over the distal tibia) and cheek (over the zygomatic arch) of eight healthy men before, during, and after 24 h of HDT. Results were calculated as a percentage of baseline value (100% measured during pre-tilt upright sitting). Cutaneous blood flow in the cheek increased significantly to 165 +/- 37% (mean +/- SE, p less than 0.05) at 9-12 h HDT, then returned to near baseline values by 24 h HDT (114 +/- 29%, NSD), despite increased local arterial pressure. Microvascular flow in the leg remained significantly elevated above baseline througout 24 h HDT (427 +/- 85% at 3 h HDT and 215 +/- 142% at 24 h HDT, p less than 0.05). During the 6-h upright sitting recovery period, cheek and leg blood flow levels returned to near pre-tilt baseline values. Because hydrostatic effects of HDT increase local arterial pressure at the carotid sinus, baroreflex-mediated withdrawal of sympathetic tone probably contributed to increased microvascular flows at the head and leg during HDT. In the leg baroreflex effects combined with minimal stimulation of local veno-arteriolar and myogenic autoregulatory vasoconstriction to elicit relatively larger and more sustained increases in cutaneous flow during HDT. In the cheek, delayed myogenic vasoconstriction and/or hurmonal effects apparently compensated for flow elevation by 24 h of HDT. Therefore, localized vascular adaptations to gravity probably explain differences in acclimation of lower and upper body blood flow to HDT and actual microgravity.

Stout, M. Shannon↗

Assessment of Extremes in Global Precipitation Products: How Reliable Are They?

Global gridded precipitation products have proven essential for many applications ranging from hydrological modeling and climate model validation to natural hazard risk assessment. They provide a global picture of how precipitation varies across time and space, specifically in regions where ground-based observations are scarce. While the application of global precipitation products has become widespread, there is limited knowledge on how well these products represent the magnitude and frequency of extreme precipitation—the key features in triggering flood hazards. Here, five global precipitation datasets (MSWEP, CFSR, CPC, PERSIANN-CDR, and WFDEI) are compared to each other and to surface observations. The spatial variability of relatively high precipitation events (tail heaviness) and the resulting discrepancy among datasets in the predicted precipitation return levels were evaluated for the time period 1979–2017. The analysis shows that 1) these products do not provide a consistent representation of the behavior of extremes as quantified by the tail heaviness, 2) there is strong spatial variability in the tail index, 3) the spatial patterns of the tail heaviness generally match the Köppen–Geiger climate classification, and 4) the predicted return levels for 100 and 1000 years differ significantly among the gridded products. More generally, our findings reveal shortcomings of global precipitation products in representing extremes and highlight that there is no single global product that performs best for all regions and climates.

Risk assessment↗

Combined, time-resolved, in situ neutron reflectometry and X-ray diffraction analysis of dynamic SEI formation during electrochemical N 2 reduction

One means of improving performance for electrochemical ammonia production through the Li-mediated N 2 reduction reaction (Li-NRR) is by cycling the current driving the reaction between open-circuit conditions and periods of applied current density. Herein, we have investigated the dynamics of the electrode–electrolyte interface under Li-NRR conditions during current cycling using in situ time-resolved neutron reflectometry and grazing-incidence synchrotron X-ray diffraction. During cycling, measured neutron reflectivity curves indicated bilayer formation in which Li-containing species such as LiOH, Li 2 O, and small quantities of Li 3 N and metallic Li primarily appeared in a thin layer at the cathode surface, above which formed a much larger, porous, ‘solid–electrolyte interface’ (SEI) layer. Upon return to open-circuit conditions, Li-containing species quickly moved out of the thin layer, leaving a compact, stable layer of decomposition products underneath the SEI layer. This SEI layer concomitantly filled with electrolyte or dissolved, becoming indistinguishable from the electrolyte via contrast in scattering-length density (SLD). During the second current cycle, Li-containing species again preferentially deposited directly atop the cathode, with the thick SEI-like layer again appearing within a minute. This SEI layer exhibited a lower SLD more quickly than in the first cycle, which might suggest that Li-containing species become distributed within the porous SEI layer. Furthermore, these time-resolved observations of SEI and plated layers during current cycling suggest that benefits associated with return to open-circuit conditions between periods of applied current density may be related to the concomitant loss of Li-containing species from a thin layer at the cathode surface into a porous SEI layer that becomes filled with electrolyte or dissolves.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The OSIRIS-Rex Asteroid Sample Return: Mission Operations Design

The OSIRIS-REx mission employs a methodical, phased approach to ensure success in meeting the missions science requirements. OSIRIS-REx launches in September 2016, with a backup launch period occurring one year later. Sampling occurs in 2019. The departure burn from Bennu occurs in March 2021. On September 24, 2023, the SRC lands at the Utah Test and Training Range (UTTR). Stardust heritage procedures are followed to transport the SRC to Johnson Space Center, where the samples are removed and delivered to the OSIRIS-REx curation facility. After a six-month preliminary examination period the mission will produce a catalog of the returned sample, allowing the worldwide community to request samples for detailed analysis.Traveling and returning a sample from an Asteroid that has not been explored before requires unique operations consideration. The Design Reference Mission (DRM) ties together space craft, instrument and operations scenarios. The project implemented lessons learned from other small body missions: APLNEAR, JPLDAWN and ESARosetta. The key lesson learned was expected the unexpected and implement planning tools early in the lifecycle. In preparation to PDR, the project changed the asteroid arrival date, to arrive one year earlier and provided additional time margin. STK is used for Mission Design and STKScheduler for instrument coverage analysis.

Pilot Field Test: Use of a Compression Garment During a Stand Test After Long-Duration Space Flight

Orthostatic intolerance (OI) is a concern for astronauts returning from long-duration space flight. One countermeasure that has been used to protect against OI after short-duration bed rest and space flight is the use of lower body and abdominal compression garments. However, since the end of the Space Shuttle era we have not been able to test crewmembers during the first 24 hours after landing on Earth. NASA's Pilot Field Test provided us the opportunity to test cardiovascular responses of crewmembers wearing the Russian Kentavr compression garment during a stand test at multiple time points throughout the first 24 hours after landing. HYPOTHESIS We hypothesized that the Kentavr compression garment would prevent an increase in heart rate (HR) >15 bpm during a 3.5-min stand test. METHODS: The Pilot Field Test was conducted up to 3 times during the first 24 hours after crewmembers returned to Earth: (1) either in a tent adjacent to the Soyuz landing site in Kazakhstan (approx.1 hr) or after transportation to the Karaganda airport (approx. 4 hr); (2) during a refueling stop in Scotland (approx.12 hr); and (3) upon return to NASA Johnson Space Center (JSC) (approx.24 hr). We measured HR and arterial pressure (finger photoplethysmography) for 2 min while the crewmember was prone and throughout 3.5 min of quiet standing. Eleven crewmembers consented to participate; however, 2 felt too ill to start the test and 1 stopped 30 sec into the stand portion of the test. Of the remaining 8 crewmembers, 2 did not wear the Russian Kentavr compression garment. Because of inclement weather at the landing site, 5 crewmembers were flown by helicopter to the Karaganda airport before initial testing and received intravenous saline before completing the stand test. One of these crewmembers wore only the portion of the Russian Kentavr compression garment that covered the lower leg and thus lacked thigh and abdominal compression. All crewmembers continued wearing the Russian Kentavr compression garment during the second testing session in Scotland, but none wore it during testing at JSC. RESULTS: The mean Delta HR from the supine to standing position in the 8 crewmembers measured pre-flight or 60 days after return from long-duration space flight was 9.8 bpm. During the first few hours after landing from long-duration space flight, the mean Delta HR of the 6 crewmembers who wore the Russian Kentavr compression garment in Kazakhstan or Karaganda was +14 bpm and the change in mean arterial pressure (Delta MAP) was +0.8 mmHg, while the 2 crewmembers who did not wear the Russian Kentavr compression garment had a Delta HR of +38 bpm and a Delta MAP of +1.1 mmHg. In Scotland, 4 crewmembers wore the Russian Kentavr compression garment and had a Delta HR of +7.4 bpm while the 3 crewmembers who did not wear it had a Delta HR of +25.0 bpm. Seven crewmembers were tested upon return to JSC approx. 24 hr after landing, but none wore the Russian Kentavr compression garment and their Delta HR was 16.0 bpm. CONCLUSIONS: These are the first stand-test data to be collected from long-duration crewmembers during the first 24 hr of re-adaptation to gravity on Earth. The Delta HR measured in crewmembers who completed the stand-test while wearing Kentavr within the first approx.4 hours after returning to Earth was only slightly elevated from pre-flight Delta HR, while the few subjects who did not wear the Russian Kentavr compression garment had a much larger increase in HR in order to maintain arterial pressure throughout 3.5-min of standing. These data demonstrate the effectiveness of a compression garment in preventing large increases in HR during a 3.5 min stand test after long-duration space flight. However, the fact that three crewmembers were too ill to complete the test or was not able to complete 3.5 min of standing despite wearing the Russian Kentavr compression garment indicates that wearing a compression garment does not resolve all problems crewmembers face during the period of re-adaptation immediately after return to Earth's gravity.

Laurie, S. S.↗

The Effect of Temperature on the Preservation of Volatile-Rich Lunar Samples

Introduction. The Moon’s south pole is a high-priority target for human exploration and scientific study. This interest is, in part, due to the presence of Permanently Shadowed Regions (PSRs), which could contain high concentrations of unique volatiles at cryogenic temperatures [1]. Returned samples from PSRs may include a unique combination of rocks, regolith, and volatile species, providing unprecedented insights into the history of the Solar System and the potential for resource utilization on the Moon. However, because PSR samples are cryogenic up-on collection, lunar polar sample return will eventually require cold stowage for the journey from the Moon to Earth. Without cold stowage, PSR sample return will likely result in phase changes and chemical reactions within the volatile component of the sample, which would negatively impact the resulting scientific studies of those samples. This abstract summarizes the initial results from an ongoing characterization of analog PSR samples at a range of temperatures, with the goal of defining the temperatures needed for a flight cold stowage freezer. Background. Based on remote sensing observations of the Moon [2], south polar PSRs range in temperature from ~120K for small and/or shallow PSRs to ~20K at the most extreme locations in large, deep PSRs. A range of volatiles have been hypothesized to exist at the surface or subsurface of the lunar poles [3-5 and others]. This hypothesis was verified when the LCROSS mission impacted the <50-K PSR in the crater Cabeus, detecting a range of volatiles from water to low condensation temperature species such as H2S and methane [6]. Species such as H2S and ammonia (also detected by LCROSS) are also highly reactive, and increase the likelihood of chemical reactions at elevated (non-cryogenic) temperatures. At the Johnson Space Center’s Planetary Exploration and Astromaterials Research Laboratory (JSC-PEARL), we have developed a volatile-bearing lunar simulant that incorporates several of the species detected by LCROSS [Table 1] mixed cryogenically with the USGS Lunar Highlands Type (LHT) regolith simulant. The new volatile-regolith simulant will be used to assess the degree of sample alteration at room temperature, -20°C, -80°C, and -196°C (liquid nitro-gen), over a two-week period. Room temperature samples represent those likely to be returned during initial missions without cold stowage, -20°C provides an analog to Apollo cold curated samples, -80°C is the temperature of multiple flight payload freezers (e.g., MELFI), and -196°C is analogous to lunar PSRs. Two weeks is an approximation of the time between sample collection and Earth return for initial Artemis missions. Over this period of time, sample head-space gases will be analyzed using a Universal Gas Analyzer (UGA, a type of mass spectrometer) coupled with a Baratron pressure sensor. After testing, the regolith component of the simulant will be purged of volatiles and preserved for future electron beam and/or FTIR analysis. Experimental Procedure. Volatile-regolith simulants will be produced as an initial homogenous batch; this batch will then be distributed into aliquots (gas chromatography/GC vials or cryo vials), ensuring that each sample has the same starting composition and conditions [Fig. 1]. In addition to the “full” simulant shown in Table 1, less complex simulant compositions will be used as baseline and control samples [Table 2]. Aliquots will be produced in triplicate for each simulant composition, storage temperature, and date of sampling. Headspace gases in all Day 0 samples will be analyzed by the UGA immediately. Cold storage samples for future analytical days will be placed in freezers appropriate to their target temperatures (-20°C, -80°C, -196°C). For ambient-temperature samples, regolith and regolith-water samples will be stored in a fume hood, while the full simulant will be stored in a sealed Parr vessel for safety; no other simulants (RWCM/ RWCM+) will be stored at ambient temperature for this test. Samples will be analyzed by UGA in this manner on each Analysis Day outlined in Table 2. Analytical Data. The UGA measures the partial pressures in a single sample aliquot over a set mass range of 0-105 atomic mass units (AMU) [Figure 2]; this set range was selected to slightly exceed the mass of the highest-mass expected reaction product (H2SO4). The Baratron complements the UGA by measuring the total pressure in the headspace of a sample vial. Coupled together, the quantitative abundances of gases will be monitored throughout the test. UGA analyses of the triplicate samples for each storage temperature, day, and simulant composition will be averaged, and standard deviations for each will be calculated. The compositions of starting species (shown in Table 1) will be characterized as a function of time, and the presence of any new compounds (reaction products) will be monitored as well. Total pressures will be recorded for each sample analysis, and any samples that show signs of leakage (e.g., a significant reduction in pressure or simulant volatiles) will be discarded. Anticipated Results. Testing is planned to begin in January 2022. The resulting data will allow compositional and phase changes in the volatile component of the simulants to be determined. Both the reduction in initial compounds and the addition of reaction products are expected to be observed. In addition, the relative efficacy of the different temperatures at pre-serving the initial composition of the simulants will be quantified. Finally, the regolith component of each sample will be argon-purged and stored in a controlled environment for future laboratory analysis. Compositional and morphological changes in the regolith are expected for samples above 0°C. This test will be repeated three times over the course of 2022. Understanding the effect of temperature on both the volatile and regolith components of analog lunar materials will allow requirements for a cold stowage freezer to be developed. The implementation of cold stowage for lunar polar missions will maximize the preservation of returned samples, enabling ground-breaking lunar and Solar System volatiles science for decades to come.

J L Mitchell↗

Interim Report of the Astronomy Spacelab Payloads Study: Ultraviolet and Optical Astronomy - Volume 2

The Space Shuttle will comprise NASA's primary transportation system into near-earth orbit during the 1980s. The Shuttle will provide the astronomical community with a major new capability to send a wide variety of instrumentation into orbit, to utilize it there under manned or automatic control for periods from seven to thirty days, and to return it to the ground. To this end the European Space Research Organization (ESRO) is developing Spacelab, an array of interchangeable components -pressurized manned modules, unpressurized pallets and related support systems - to be mounted in the Shuttle payload bay. Spacelab will offer important opportunities to carry out astronomical research with instruments optimized for specific objectives. With a high flight frequency and with the ability to modify or interchange telescopes and instruments between flights, one will not need to make rigid long-term commitments to specific and compromised telescope/instrument/ detector combinations as is the case for automated satellites. Observational techniques demanding the physical return of data and equipment - in particular the use of photographic film, instruments requiring tight calibration controls, cryogens, high-risk detectors and degradeable optical coatings -will open research areas not readily addressed by automated satellites. Although Shuttle flight duration will be limited to periods from seven to thirty days, substantial data can be obtained with a single instrument on short missions, if targets are carefully selected and prioritized, and a large number of instruments can be accommodated on a single flight. Important astronomical data are regularly obtained on sounding rocket flights of five minutes duration. Spacelab will provide far longer observing periods for large and small telescopes, with resources greatly exceeding those of sounding rockets, while retaining much of the sounding rocket philosophy in terms of instrument flexibility, simplicity, reliability assurance and development costs. The Ultraviolet and Optical Astronomy Program on Spacelab is being planned to provide optical astronomers with relatively simple and regular access to the extended wavelength coverage, the superior image quality and the darkness of the night sky available above the earth's atmosphere. In a rapidly evolving science one cannot predict what problems will be timely in the 1980s. Extrapolating from the current epoch, however, one can envision a continuing interest in such areas as the structure, composition and phenomenology of planetary surfaces and atmospheres; the composition and physical nature of the interstellar medium; the composition, structure and life history of stars, especially those in advanced stages of evolution; the stellar population of other galaxies; such enigmatic phenomena as X-ray binary black holes, pulsars, active galactic nuclei and quasars; large scale interactions between galaxies and the nature of the intergalactic medium; precise calibration of the Hubble law for the expansion of the universe; the average density of the universe; and the existence of extraterrestrial life.

Source record↗

The Search for Extant Life on Mars: A Human Exploration Objective

A search for evidence of extant life on Mars should be conducted prior to and as part of human exploration missions. Potentially habitable environments for modern life occur on Mars. Despite a vigorous campaign of exploration of the surface over the last 3 decades, no mission has attempted to search for signatures of extant life since the Viking landers in 1976. Finding an example of extant life beyond Earth would be one of the greatest scientific discoveries of all time. This is especially important because (once discovered) the biochemistry and metabolism of the life form can be studied. Earth and Mars exchange materials over geologic time because impacts eject rock and crustal materials into space that are eventually deposited on other planets and moons [1]. Therefore, Earth and Mars could share life with a common origin and similar biochemistry; if this is the case, life on Mars likely experienced billions of years of evolution in isolation from Earth. Alternatively, Mars may host a distinct genesis of life which could be evident from its different biochemistry. Either discovery would change our understanding of life in the solar system and beyond. The Mars 2020/Perseverance sample collection mission is not optimized for finding extant life because the site for sample collection, Jezero Crater, was chosen for its ancient habitability and likelihood to host fossil evidence of life. Furthermore, the samples collected will not be returned for at least a decade. Within that period, technology development for human exploration will likely be underway and it is possible that humans will land on Mars without an updated knowledge of extant life on Mars, which may pose a risk both to those mission crews and to Earth when they return. Thus, it is important to perform a search for extant life on Mars prior to humans landing at a site where life may persist. Salts and shallow ground ice are particularly important environments to evaluate for extant life prior to human missions because they may be encountered and interacted with by human crews.

C.R. Stoker↗

Techno-economic analysis and life cycle assessment for electrochemical ammonia production using proton conducting membrane

Green ammonia production is facing increasing interest on a global scale as a hydrogen carrier for power generation as well as fertilizer for food production. The conventional Haber-Bosch method for ammonia synthesis is energy demanding, requires high purity hydrogen, and is based on fossil fuels. A preliminary techno-economic model for electrochemical ammonia synthesis at near ambient pressure using feed rates of 32 metric ton/day for hydrogen and 135 metric ton/day for nitrogen is presented in this study. Various pathways using different methods for nitrogen generation and hydrogen production were investigated to gain insight into added energy savings per metric ton of ammonia. Electrochemical synthesis using electrolysis for hydrogen and cryogenic nitrogen was found to be a potentially viable pathway for green ammonia. The profitability metrics including discounted cash flow rate of return, net present value and discounted payback period were estimated to be 8%, $40 MM, and 4–6 years respectively for this pathway. The cost of electricity, conversion rate, and conversion efficiency dominate the tonnage cost of ammonia and were used to assess the feasibility of the model. A life cycle assessment was also conducted to assess the environmental impact of a well to product ammonia process.

08 HYDROGEN↗

Consequences of neglecting the interannual variability of the solar resource: A case study of photovoltaic power among the Hawaiian Islands

The interannual variability of the solar irradiance and meteorological conditions are often ignored in favor of single-year data sets for modeling power generation and evaluating the economic value of photovoltaic (PV) power systems. Yet interannual variability significantly impacts the generation from one year to another of renewable power systems such as wind and PV. Consequently, the interannual variability of power generation corresponds to the interannual variability of capital returns on investment. The penetration of PV systems within the Hawaiian Electric Companies' portfolio has rapidly accelerated in recent years and is expected to continue to increase given the state's energy objectives laid out by the Hawaii Clean Energy Initiative. We use the National Solar Radiation Database (1998-2015) to characterize the interannual variability of the solar irradiance and meteorological conditions across the State of Hawaii. These data sets are passed to the National Renewable Energy Laboratory's System Advisory Model (SAM) to calculate an 18-year PV power generation data set to characterize the variability of PV power generation. We calculate the interannual coefficient of variability (COV) for annual average global horizontal irradiance (GHI) on the order of 2% and COV for annual capacity factor on the order of 3% across the Hawaiian archipelago. Regarding the interannual variability of seasonal trends, we calculate the COV for monthly average GHI values on the order of 5% and COV for monthly capacity factor on the order of 10%. We model residential-scale and utility-scale PV systems and calculate the economic returns of each system via the payback period and the net present value. We demonstrate that studies based on single-year data sets for economic evaluations reach conclusions that deviate from the true values realized by accounting for interannual variability.

14 SOLAR ENERGY↗

The earth resources experiment package on Skylab and proposed resource investigations.

In late 1973, NASA plans to launch a three-man experimental space station, the Skylab Workshop. Technical specifications regarding the instrumental facilities of the space station are presented, giving attention to the multispectral photographic facility, the IR spectrometer, the multispectral scanner, the L-band radiometer, and the S-193 sensor. The S-193 sensor will provide data applicable to studying varying ocean surfaces, wave conditions, sea and lake ice, ocean clouds, weather prediction, and soil types. All data from the sensors will be recorded on film and analog magnetic tape for return at the end of each manned period of Skylab.

Park, A. B.↗

Increased rate of response of the pituitary-adrenal system in rats adapted to chronic stress

The response and adaptation of the pituitary-adrenal system to chronic stresses was investigated. These included individual caging, confinement, and exposure to cold for varying periods of time. Studies were carried out demonstrating that during the period of adaptation when plasma corticosterone concentrations returned toward their prestress level despite continued exposure to the stressor, the animals responded to additional stimuli of ether for 1 min, a saline injection, or release from confinement with a faster increase (within 2.5 min) in plasma corticosterone than controls (10 min). It is concluded that during adaptation to a chronic stress the pituitary-adrenal system is not inhibited by the circulating steroid level but is actually hypersensitive to additional stimuli.

Sakellaris, P. C.↗

Earth reencounter probabilities for aborted space disposal of hazardous nuclear waste

A quantitative assessment is made of the long-term risk of earth reencounter and reentry associated with aborted disposal of hazardous material in the space environment. Numerical results are presented for 10 candidate disposal options covering a broad spectrum of disposal destinations and deployment propulsion systems. Based on representative models of system failure, the probability that a single payload will return and collide with earth within a period of 250,000 years is found to lie in the range .0002-.006. Proportionately smaller risk attaches to shorter time intervals. Risk-critical factors related to trajectory geometry and system reliability are identified as possible mechanisms of hazard reduction.

Friedlander, A. L.↗

Mars sample return mission options (1996-2005)

Missions to the surface of Mars, carrying a Rover and having a sample return capability, constitute another logical step in the exploration of that planet in the late 1990's. Results of a recent study are described. A comparison of viable mission options, involving: retropropulsion vs. aerobraking/aeromaneuvering, direct return vs. Mars orbit rendezous, as well as the future potential of 'in-situ propellant production', is presented. An overview of a variety of scenarios of unmanned expeditions to Mars and their subsequent return to earth, within the addressed time period, is provided.

Sergeyevsky, A. B.↗