Evaluation of clad scintillating light pipes

Arrays of fibers made of scintillating material were used as position-sensitive detectors or hodoscopes for beam-finding at ion accelerators. Experiments were made with alpha's from an Am241 source incident upon one end of the fiber, the other end being viewed with a photomultiplier tube. The scintillation light was not detected in any of the fibers tested beyond about 5 cm. The effective useful lengths for detection of relativistic heavy ions were given.

Source record↗

A mathematical analysis of the theory of interplanetary scintillation in the weak scattering approximation

A simplified analytical technique is presented for modeling the interplanetary scintillation of radio sources of finite angular size with a power-law electron-density-fluctuation power spectrum. The simplification results from the representation of the scintillation spectrum in confluent hypergeometric functions. The approximations presented allow fast numerical evaluation of a spectrum for a weakly scattering but extended medium with less than 10% error over the entire spectrum. Parameters describing anisotropic electron irregularities as well as anisotropic source structure are included, and the dependence of the spectrum normalization on the scales of the medium is derived explicitly. The parametric description of the domains of convergence of the approximate expansions also provides a simple conceptualization of the relative contributions of the scattered radiation along the line of sight to the observed spectrum. This is particularly useful for sources of finite angular size. This technique is applied to previously published observations.

Mitchell, D. G.↗

Amplitude scintillation at 2 and 30 GHz on earth space paths

Extensive amplitude scintillation measurements were made simultaneously at 2.075 and 30 GHz on earth-space propagation paths. These measurements were performed as the Applications Technology Satellite (ATS-6) was moved slowly from a synchronous position over India to a new synchronous position over the United States. The variance, path loss, covariance, and spectra are discussed as functions of the path elevation angle. These results are also compared with earlier simultaneous scintillation measurements at 20 and 30 GHz during the movement of ATS-6 to its position over India.

Hodge, D. B.↗

Gamma ray spectroscopy in astrophysics: Future role of scintillation detectors

The future role of conventional scintillation detector telescopes for line gamma-ray astronomy is discussed. Although the energy resolution of the germanium detectors now being used by several groups is clearly desirable, the larger effective areas and higher efficiencies available with scintillation detectors is advantageous for many observations. This is particularly true for those observations of astrophysical phenomena where significant line broadening is expected.

Kurfess, J. D.↗

Aperture averaging effects in stellar scintillation

Stellar scintillation has been measured for apertures as low as 0.012 m by using photoncounting techniques. The scintillation measurements have been made for various aperture sizes in quick succession in order to determine experimentally the effects of aperture averaging. The results of the experiment are compared with the predictions of a model proposed earlier in the literature to quantify the phenomenon.

Iyer, R. S.↗

Amplitude scintillation at 2 and 30 GHz on earth space paths

Extensive amplitude scintillation measurements have been made simultaneously at 2.075 and 30 GHz on earth-space propagation paths. These measurements were performed as the Applications Technology Satellite (ATS-6) was moved slowly from a synchronous position over India to a new synchronous position over the United States. The variance, path loss, covariance, and spectra are discussed as functions of the path elevation angle. These results are also compared with earlier simultaneous scintillation measurements at 20 and 30 GHz during the movement of ATS-6 to its position over India.

Hodge, D. B.↗

Measurements of the magnetic field orientation in the Jovian ionosphere deduced from Pioneer 10 and 11 scintillation observations

In this paper the S band scintillations observed during the Pioneer 10 and 11 occultation measurements of Jupiter are analyzed. It is found that while the electron density irregularities are isotropic in the collision-dominated lower ionosphere, they are anisotropic in the upper ionosphere because of alignment along the magnetic field. By using Rytov's approximation the frequency spectrum of the log-amplitude scintillations is derived for a wave propagating in an anisotropic turbulent medium. It is shown that the spectrum depends to a large extent on the direction of anisotropy and is therefore useful for measuring the orientation of the magnetic field in regions that have not yet been probed by direct measurements. This new technique is applied to the Pioneer 10 and 11 observations, and is used to deduce the first measurements of magnetic field orientation in the ionosphere of Jupiter.

Woo, R.↗

Properties of an imaging gas scintillation proportional counter

An instrument which combines the improved energy resolution offered by the gas scintillation proportional counter (GSPC) with the submillimeter imaging capabilities of the multiwire proportional counter (MWPC) is described. The imaging gas scintillation proportional counter detects the centroid of the UV light excited by X-ray photons interacting in the noble gas of the GSPC with a UV sensitive gas in the MWPC. The prototype counter yields a measured performance of 9% (FWHM) energy resolution and 0.9 mm (FWHM) spatial resolution at 6 keV. Further design refinements should achieve 18% (FWHM) energy resolution and 0.6 mm (FWHM) spatial resolution at 1 keV.

Ku, W. H.-M.↗

An imaging gas scintillation proportional counter for the detection of subkiloelectron-volt X-rays

A large area imaging gas scintillation proportional counter (IGSPC) was constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counted (GSPC) with a micron polyprotylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. Over a sensitive area of 21 cu cm the instrument has a measured energy resolution of 17.5% (FWHM) and 1.9 mm (FWHM) spatial resolution at 1.5 keV.

Hailey, C. J.↗

Solar wind motion within 30 R solar masses - Spacecraft radio scintillation observations

New remote-sensing observations are reported of the solar wind motion within about 30 earth radii. Use is made of the interplanetary scintillation (IPS) spaced receiver technique with the radio source being a spacecraft signal (rather than a natural radio source as in previous spaced receiver studies). The spacecraft used are Helios A and B and the Viking orbiters. The purposes of the study are (1) to augment the scarce estimates of solar wind bulk flow speed near the sun and in the ecliptic with measurements made using spacecraft signals, and (2) to estimate random velocity components and identify the region where the random velocity is a significant fraction of the mean velocity. In addition, the radial evolution of speed and random velocity is compared with that of the plasma density fluctuation spectrum. Also reported are the first accurately normalized IPS scintillation index measurements using a monochromatic point source.

Armstrong, J. W.↗

The role of in-situ measurements in scintillation modelling

It is shown that the conflicting equatorial scintillation observations obtained from greatly separated ground stations can be organized in the framework of a longitudinal variation of irregularity occurrence, given satellite-borne, in situ measurements of irregularity amplitude of the global F-region irregularity morphology's general features. High-inclination satellite data are used to delineate the morphological features of the polar cap by means of such a method. The lack of diurnal and magnetic control of the irregularity morphology within the low solar flux, northern winter polar cap distinguishes this region from the auroral oval regime. A polar-orbiting communication system sensitive to phase perturbations may observe large differences in the phase-to-amplitude scintillation ratio, as it traverses the auroral oval and proceeds into the polar cap, with its sun-aligned arc system.

Basu, S.↗

Position measurements for heavy ion beams using a sodium iodide scintillator

A 50 cm diameter, 1.7 cm thick disc of NaI scintillator has been mounted to permit edge viewing by four photomultipliers. Energetic heavy ions passing through the scintillator at different positions cause a variation in the division of light among the photomultipliers. A performance close to the expected limit for 670 MeV/n neon has been achieved. Calculations of expected response using an optical model agree well with the measurements.

Buffington, A.↗

Gamma ray detection with long NaI/Tl/ scintillator bars

Test measurements with a prototype NaI(Tl) scintillator for energy, position, and timing measurements in gamma ray astronomy are reported. The scintillator bar is 100 x 5 x 5 cu cm in size, and allows detection of the arrival times and pulse heights of signals from two photomultiplier tubes, one at each end of the bar. Data is gathered on the energy loss, linear position, and time-of-flight of gamma ray interactions within the bar over an energy range of 0.5-20 MeV. A mean attenuation coefficient of 0.015/cm has been determined, as have a FWHM resolution of 5 cm, 9.4%, and 10 nsec at an energy of 0.662 MeV. At 1.25 MeV the timing resolution was 6 nsec, and at 6.13 MeV the spatial resolution was 2.2 cm. The instrument is a prototype of a Compton scatter telescope being constructed for two balloon flights, one each in the Northern and Southern Hemispheres, in 1984.

Zych, A. D.↗

Fast scintillation counter system and performance

An experimental study of the fast scintillation counter (FS) system to observe a shower disk structure at Mt. Norikura is described, especially the system performance and a pulse wave-form by a single charge particles. The photomultiplier tube (PT) pulse appears at the leading edge of the main pulse. To remove this PT-pulse from the main pulse, the frame of the scintillator vessel was changed. The fast triggering system was made to decrease the dead time which came from the use of the function of the self triggering of the storage oscilloscope (OSC). To provide a new field on the multi-parameter study of the cosmic ray showers, the system response of the FS system also improved as a result of many considerations.

Sasaki, H.↗

Microprocessor-based single particle calibration of scintillation counter

A microprocessor-base set-up is fabricated and tested for the single particle calibration of the plastic scintillator. The single particle response of the scintillator is digitized by an A/D converter, and a 8085 A based microprocessor stores the pulse heights. The digitized information is printed. Facilities for CRT display and cassette storing and recalling are also made available.

Mazumdar, G. K. D.↗

On method of muon spectrum measurements by the scintillation detectors of a large thickness T4t sub o

Various methods for the study of muon spectrum are presented. The direct ones include the muon energy measurements by magnetic spectrometers. The indirect ones deal with the reconstruction of the muon spectrum from the spectrum of secondary particles obtained by burst or calorimeter technique. The burst technique is based on the measurement of the number of cascade particles, mainly in the cascade maximum, by the detectors of small thickness T sub 0. The calorimeter method consist in determination of the cascade energy with help of the cascade curve shape. The multilayer detectors are used for this purpose. They are usually comprised of proportional counters, X-ray emulsion chambers or scintillation counters with the target material placed between them. The scintillation detectors of a large thickness measures the total cascade energy directly and the detector works as a true calorimeter. When the total energy is detected, the cascade spectrum differs from the muon one.