Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION COUNTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Data acquisition system with pulse height capability for the TOFED time-of-flight neutron spectrometer

A new time-of-flight neutron spectrometer TOFED has been constructed for installation at Experimental Advanced Superconducting Tokamak. A data acquisition system combining measurements of flight time and energy from the interaction of neutrons with the TOFED scintillators has been developed. The data acquisition system can provide a digitizing resolution better than 1.5% (to be compared with the >10% resolution of the recoil particle energy in the plastic scintillators) and a time resolution <1 ns. At the same time, it is compatible with high count rate event recording, which is an essential feature to investigate phenomena occurring on time scales faster than the slowing down time (≈100 ms) of the beam ions in the plasma. Implications of these results on the TOFED capability to resolve fast ion signatures in the neutron spectrum from EAST plasmas are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High repetition rate neutron flux array using digital-signal processing and scintillators for study of high performance plasma at JT-60U

Aiming at increasing the count rate capability of the radial neutron collimator system in JT-60U, a digital-signal processing system has been extended to seven channels for data acquisition of stilbene crystal detector using analog-to-digital converters equipped with a fast flash memory. In this method, the detected pulses were postprocessed concerning pulse shape and pulse height. Using this system, the radial neutron collimator system can provide the information on the temporal evolution of emission rate of d-T neutrons and gamma rays as well as d-D neutrons. On the course of the development, the fast and stable handling of the large data around 7 GB is undertaken for a discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of Isotopes in Urban Source Search Low-Count Gamma Spectra Using Hopfield Neural Networks

Source search campaigns involve measurements of background gamma-ray spectra with a mobile detector-spectrometer traveling along arbitrarily chosen trajectories over a wide screening area. Radiation counts are typically measured with a tellurium-doped sodium iodide [NaI(Tl)] scintillator detector-spectrometer in short acquisition intervals, usually 1 s. The objective is to detect orphan isotopes with half-lives shorter than those of the isotopes in the natural background. In principle, radioisotopes can be identified by their unique gamma emission spectrum. However, detecting orphan isotopes in search data is challenging because low counts measured in short acquisition intervals result in incomplete spectral lines. In this study, we investigate the performance of a Hopfield neural network (HNN) that implements an auto-associative memory for the detection of isotopes of interest in an urban search campaign. The HNN is trained on one example of gamma spectra with well-resolved spectral lines of each isotope of interest. During testing, the auto-associative memory implementation of the HNN processes low-count gamma spectra with partially complete isotopic lines by matching incoming measurements to the closest one of its memory-stored patterns. The testing database consisted of almost 10 000 1-s gamma spectra, including measurements of orphan isotopes 137 Cs, 241 Am, and 131 I, obtained during two urban search surveys with a NaI(Tl) detector. The performance of the HNN detection algorithm was evaluated using precision, recall, and F1 scores, and benchmarked with a multiple linear regression (MLR) identification algorithm. In conclusion, the test results demonstrate that HNN outperforms MLR in the detection of all the isotopes of interest.

Auto associative memory↗

Elimination of ghosting artifacts from wavelength-shifting fiber neutron detectors

Misassignment of neutron position (ghosting) produces artifacts, which have been observed in wavelength-shifting (WLS) fiber detectors developed for time-of-flight (TOF) neutron powder diffraction. In position-sensitive detectors (PSDs) with WLS fiber encoding, thermal and cold neutrons interact with a monolithic 6LiF/ZnS:Ag scintillator screen, and scintillation photons are generated and transported through the crossed fibers to photomultipliers (PMTs). The neutron position is determined by photon counts in PMTs within a preset time window. Ghosting occurs when neutrons hit the group boundaries of two neighboring PMTs for x-position multiplexing, which is modeled as resulting from a long travel length (about 3-5 mm) of a small number of scintillation photons. This model is supported by the change observed in aperture images when the threshold number for photon-pulses was adjusted for a neutron event determination. When the threshold number of photon-pulses was set above 10 for each PMT, the ghost peaks in the aperture images and TOF spectra of powder diffraction were strongly suppressed or completely eliminated, and the intrinsic background levels of the WLS detectors were significantly reduced. Our result indicates that WLS fiber detector is a promising alternative for 3He PSDs for neutron scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Issues on a tritium measurement system's qualification on a dismantling site

In order to choose the suitable outlet, final disposal of radioactive package requires good knowledge of radiological characteristics of the waste. As part of a nuclear facility's dismantling within tritium proceeds, {sup 3}H contamination is evaluated by using wipe tests which are measured by liquid scintillation. The industrialist's choice is a triple coincidence to double coincidence ratio (TDCR) method with a dry counting protocol. The initial protocol had been defined to reduce the quantity of radioactive liquid waste and to perform an automatic quenching correction. A based on TDCR method liquid scintillation analyser was installed on the decommissioning site. It had had to be used by operator non specialized in metrology, This poster presents the laboratory's feedback on the use of the TDCR method on a site: - problems encountered about protocol on a decommissioning site - protocol adjustments and their consequences. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A novel method for modeling the neutron time of flight (nTOF) detector response in current mode to inertial confinement fusion experiments.

There are several machines in this country that produce short bursts of neutrons for various applications. A few examples are the Z machine, operated by Sandia National Laboratories in Albuquerque, NM ; the OMEGA Laser Facility at the University of Rochester in Rochester, NY ; and the National Ignition Facility (NIF) operated by the Department of Energy at Lawrence Livermore National Laboratory in Livermore, California . They all incorporate neutron time of flight (nTOF) detectors which measure neutron yield, and the shapes of the waveforms from these detectors contain germane information about the plasma conditions that produce the neutrons. However, the signals can also be %E2%80%9Cclouded%E2%80%9D by a certain fraction of neutrons that scatter off structural components and also arrive at the detectors, thereby making analysis of the plasma conditions more difficult. These detectors operate in current mode - i.e., they have no discrimination, and all the photomultiplier anode charges are integrated rather than counted individually as they are in single event counting. Up to now, there has not been a method for modeling an nTOF detector operating in current mode. MCNP PoliMi was developed in 2002 to simulate neutron and gamma ray detection in a plastic scintillator, which produces a collision data output table about each neutron and photon interaction occurring within the scintillator; however, the post processing code which accompanies MCNP PoliMi assumes a detector operating in single event counting mode and not current mode. Therefore, the idea for this work had been born: could a new post processing code be written to simulate an nTOF detector operating in current mode? And if so, could this process be used to address such issues as the impact of neutron scattering on the primary signal? Also, could it possibly even identify sources of scattering (i.e., structural materials) that could be removed or modified to produce %E2%80%9Ccleaner%E2%80%9D neutron signals? This process was first developed and then applied to the axial neutron time of flight detectors at the Z Facility mentioned above. First, MCNP PoliMi was used to model relevant portions of the facility between the source and the detector locations. To obtain useful statistics, variance reduction was utilized. Then, the resulting collision output table produced by MCNP PoliMi was further analyzed by a MATLAB postprocessing code. This converted the energy deposited by neutron and photon interactions in the plastic scintillator (i.e., nTOF detector) into light output, in units of MeVee%D1%84 (electron equivalent) vs time. The time response of the detector was then folded into the signal via another MATLAB code. The simulated response was then compared with experimental data and shown to be in good agreement. To address the issue of neutron scattering, an %E2%80%9CIdeal Case,%E2%80%9D (i.e., a plastic scintillator was placed at the same distance from the source for each detector location) with no structural components in the problem. This was done to produce as %E2%80%9Cpure%E2%80%9D a neutron signal as possible. The simulated waveform from this %E2%80%9CIdeal Case%E2%80%9D was then compared with the simulated data from the %E2%80%9CFull Scale%E2%80%9D geometry (i.e., the detector at the same location, but with all the structural materials now included). The %E2%80%9CIdeal Case%E2%80%9D was subtracted from the %E2%80%9CFull Scale%E2%80%9D geometry case, and this was determined to be the contribution due to scattering. The time response was deconvolved out of the empirical data, and the contribution due to scattering was then subtracted out of it. A transformation was then made from dN/dt to dN/dE to obtain neutron spectra at two different detector locations.

Nelson, Alan J.↗

Application of a digital pileup resolving method to high count rate neutron measurements

The possibility of working in high count rate conditions is an important issue for neutron measurements applied to fusion experiments in order to extend the measurement dynamic range and time resolution. One of the main issues of high count rate operation is the overlapping of closely spaced events (pileup) that produces a distortion in their amplitude and therefore in the pulse height spectra. The usual way to deal with such pileup events using standard analog electronics is to reject them in the energy analysis process. Thanks to digital acquisition techniques, the waveforms of pileup events can be recorded and elaborated in order to reconstruct the contributing original single events. This work presents the results of the application of a pileup resolving method for the reconstruction and analysis of overlapping events to pulses acquired digitally from a NE213 liquid scintillator detector. The measurements have been carried out at the PTB accelerator facility with 14 MeV neutrons at total count rates over 400 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Field Test Report Neutron Scintillator Array Dry Storage Cask Scanner FY2024

During two weeks of Field Testing at the Idaho National Laboratory INTEC Cask Farm in July and August 2024, the LLNL Dry Storage Cask Scanner Array was lifted on top of an MC-10 dry storage fuel cask and operated to acquire neutron and gamma-ray data from the 24 fuel bundle positions. Neutron and gamma-ray data acquisition scans across the top of the cask of varying dwell times were performed July 15-18, 2024 and August 19-22, 2024 to evaluate the ability of the scanner data to reveal asymmetries in the fuel positions that reflect asymmetries in the MC-10 cask fuel bundle loading. The MC-10 cask 24 position fuel bundle loading at the INTEC Cask Farm is well documented, including the locations of six empty fuel bundle positions. This loading presents an opportunity to test the ability of the scanner system to detect diversion of spent fuel bundles as well as to validate the MC-10 cask MCNP modeling. The cask scanner array consists of six Stilbene crystal scintillator detectors and a linear actuator frame that moves the six detectors across the MC-10 dry storage cask to obtain data above each of the 24 fuel bundle positions. The detectors are connected to a pulse-shape discrimination data acquisition system capable of generating separate neutron and gamma-ray spectra for each detector and for each scan position. From the prior single detector Field Test in 2021 and iteration with MCNP modeling, the neutron and gamma-ray data were analyzed in multiple energy regions to identify an analysis method that would provide the strongest and most consistent signature of the asymmetric MC-10 cask fuel loading1 . From both the 2021 Field Test and the current Field Test results, the neutron capture gamma-ray count rate around 2.2 MeV provides the strongest signature of the asymmetric MC-10 cask fuel loading and has qualitative agreement with MCNP calculations. Counting all gamma-rays produces a similar signature. Neutrons emerging from the cask top are moderated and captured by the hydrogen in the polyethylene moderator and scintillator detector, producing a 2.2 MeV gamma ray which is seen in the scintillator gamma-ray spectrum. The count rate in the 2.2 MeV gamma-ray region is ~50 c/s, which is ~1000x higher than the ~0.05 n/s rate in the > 4MeV neutron region, and ~50x greater than the ~1 n/s rate in the neutrons > 500 keV region. Analysis of the 2.2 MeV neutron-capture Compton-scattered gamma-rays produces a statistically significant signature of the INTEC Cask Farm MC-10 asymmetric fuel loading. MCNP simulations indicate that the average neutron energy spectrum offers the potential to detect a large asymmetry from several missing bundles as well as individual missing fuel bundles. Testing this feature will require measurements on a cask with single missing elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Role of the doubly stochastic Neyman type-A and Thomas counting distributions in photon detection

The sums of Meyman type-A and Thomas random variables are shown to retain their form under the constant multiplication parameter constraint. The conditions under which the two random variables converge in distribution to the fixed multiplicative Poisson, and to the Gaussian, are presented. It is shown that the latter result is important, in that it provides a solution to likelihood-ratio detection, estimation and discrimination problems in the presence of many kinds of signal and noise. Among the explicit applications presented are: (1) the photon-counter scintillation detection of nuclear particles when particle flux is low, (2) the photon-counting detection of weak optical signals in the presence of ionizing radiation, and (3) the design of a star-scanner spacecraft guidance system adequate for hostile space environments.

Teich, M. C.↗

Development of the Fast Scintillation Detector with Programmable High Voltage Adjustment Suitable for Moessbauer Spectroscopy

This work is focused on a development of a compact fast scintillation detector suitable for Moessbauer spectroscopy (low energy X-ray/{gamma}-ray detection) where high counting rates are inevitable. Optimization of this part was necessary for a reliable function, better time resolution and to avoid a detector pulses pile-up effect. The pile-up effect decreases the measurement performance, significantly depends on the source activity and also on the pulse duration. Our new detection unit includes a fast scintillation crystal YAP:Ce, an R6095 photomultiplier tube, a high voltage power supply socket C9028-01 assembly, an AD5252 digital potentiometer with an I2C interface and an AD8000 ultra fast operation preamplifier. The main advantages of this solution lie in a short pulse duration (less than 200 ns), stable operation for high activities, programmable gain of the high voltage supply and compact design in the aluminum housing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PLATEAUING COSMIC RAY DETECTORS TO ACHIEVE OPTIMUM OPERATING VOLTAGE

Through QuarkNet, students across the country have access to cosmic ray detectors in their high school classrooms. These detectors operate using a scintillator material and a photomultiplier tube (PMT). A data acquisition (DAQ) board counts cosmic ray hits from the counters. Through an online e-Lab, students can analyze and share their data. In order to collect viable data, the PMTs should operate at their plateau voltages. In these plateau ranges, the number of counts per minute remains relatively constant with small changes in PMT voltage. We sought to plateau the counters in the test array and to clarify the plateauing procedure itself. In order to most effectively plateau the counters, the counters should be stacked and programmed to record the number of coincident hits as well as their singles rates. We also changed the threshold value that a signal must exceed in order to record a hit and replateaued the counters. For counter 1, counter 2, and counter 3, we found plateau voltages around 1V. The singles rate plateau was very small, while the coincidence plateau was very long. The plateau voltages corresponded to a singles rate of 700–850 counts per minute. We found very little effect of changing the threshold voltages. Our chosen plateau voltages produced good performance studies on the e-Lab. Keeping in mind the nature of the experiments conducted by the high school students, we recommend a streamlined plateauing process. Because changing the threshold did not drastically affect the plateau voltage or the performance study, students should choose a threshold value, construct plateau graphs, and analyze their data using a performance study. Even if the counters operate slightly off their plateau voltage, they should deliver good performance studies and return reliable results.

Knoff, E N↗

A Robot for Nondestructive Assay of Holdup Deposits in Gaseous Diffusion Piping - 19504

Miles of contaminated pipe must be characterized as part of the decommissioning effort at deactivated gaseous diffusion enrichment facilities. The current method requires cutting away asbestos- lined thermal enclosures and performing repeated, elevated operations to manually perform nondestructive assay (NDA) on pipe from the outside. The RadPiper robot, part of the Pipe Crawling Activity Measurement System (PCAMS) developed by Carnegie Mellon University and commissioned for use at the DOE Portsmouth Gaseous Diffusion Enrichment Facility, automatically measures U-235 in pipes from the inside. This improves certainty, increases safety, and greatly reduces measurement time. The heart of the RadPiper robot is a sodium iodide scintillation detector in an innovative disc-collimated assembly. By measuring from inside pipes, the robot significantly increases its count rate relative to external through-pipe measurements. The robot also provides imagery, models interior pipe geometry, and precisely measures distance in order to localize radiation measurements. Data collected by this system provides insight into pipe interiors that is simply not possible from exterior measurements, all while keeping operators safer. This paper describes the technical details of the PCAMS RadPiper robot. Key features for this robot include precision distance measurement, in-pipe obstacle detection, ability to transform for two pipe sizes, and robustness in autonomous operation. Test results demonstrating the robot's functionality are presented, including deployment tolerance tests, safeguarding tests, and localization tests. Integrated robot tests are also shown. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance of A Real-Time Photon Counting Optical Receiver in the Presence of Emulated Channel Fading

Free-space optical communication links with terrestrial ground stations experience fading due to atmospheric scintillation and beam pointing. Fiber-coupled receiver systems experience additional fading at the interface between the fiber and free-space optics of the telescope. The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has characterized a real-time photon-counting optical ground receiver system with an atmospheric fade emulation system. The receiver system is comprised of a fiber interconnect, an array of superconducting nanowire single photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Two fiber interconnect/detector architectures have been studied. One architecture uses a 70-mode photonic lantern coupled to seven single pixel SNSPDs. The other architecture uses a 10-mode few-mode fiber (FMF) coupled to a 15-pixel SNSPD array. The receiver system complies with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency Coding and Synchronization Standard, which uses serially concatenated convolutionally coded pulse-position modulation (SCPPM). The CCSDS standard is designed for use in low photon flux missions, including the Orion Artemis-II Optical (O2O) communications demonstration. The standard utilizes a convolutional symbol interleaver which can be resized to mitigate different fades. The fade emulation system employed in this work emulates scintillation-induced, pointing-induced, and coupling-induced fading. This paper gives an overview of the real-time optical receiver system and the fade emulation system. It presents tests results which show the impact of fading on the performance on the receiver. The test results show that in the presence of channel fading, the 70-mode photonic lantern outperforms the 10-mode FMF under higher (D/r_0=9) turbulence conditions due to high fiber-coupling-induced fading and fiber coupling loss on the 10-mode FMF. When operating in lower turbulence (D/r_0=4), the 10-mode FMF outperforms the 70-mode photonic lantern. The paper also shows a larger convolutional interleaver improves the system performance as long as the receiver does not lose acquisition.

optical communications↗

Performance of a real-time photon counting optical receiver in the presence of emulated channel fading

Free-space optical communication links with terrestrial ground stations experience fading due to atmospheric scintillation and beam pointing. Fiber-coupled receiver systems experience additional fading at the interface between the fiber and free-space optics of the telescope. The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has characterized a real-time photon-counting optical ground receiver system with an atmospheric fade emulation system. The receiver system is comprised of a fiber interconnect, an array of superconducting nanowire single photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Two fiber interconnect/detector architectures have been studied. One architecture uses a 70-mode photonic lantern coupled to seven single pixel SNSPDs. The other architecture uses a 10-mode few-mode fiber (FMF) coupled to a 15-pixel SNSPD array. The receiver system complies with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications High Photon Efficiency Coding and Synchronization Standard, which uses serially concatenated convolutionally coded pulse-position modulation (SCPPM). The CCSDS standard is designed for use in low photon flux missions, including the Orion Artemis-II Optical (O2O) communications demonstration. The standard utilizes a convolutional symbol interleaver which can be resized to mitigate different fades. The fade emulation system employed in this work emulates scintillation-induced, pointing-induced, and coupling-induced fading. This paper gives an overview of the real-time optical receiver system and the fade emulation system. It presents tests results which show the impact of fading on the performance on the receiver. The test results show that in the presence of channel fading, the 70-mode photonic lantern outperforms the 10-mode FMF under higher (D/r_0=9) turbulence conditions due to high fiber-coupling-induced fading and fiber coupling loss on the 10-mode FMF. When operating in lower turbulence (D/r_0=4), the 10-mode FMF outperforms the 70-mode photonic lantern. The paper also shows a larger convolutional interleaver improves the system performance as long as the receiver does not lose acquisition.

optical communications↗

Non-Uniform Contrast and Noise Correction for Coded Source Neutron Imaging

Since the first application of neutron radiography in the 1930s, the field of neutron radiography has matured enough to develop several applications. However, advances in the technology are far from concluded. In general, the resolution of scintillator-based detection systems is limited to the $10\mu m$ range, and the relatively low neutron count rate of neutron sources compared to other illumination sources restricts time resolved measurement. One path toward improved resolution is the use of magnification; however, to date neutron optics are inefficient, expensive, and difficult to develop. There is a clear demand for cost-effective scintillator-based neutron imaging systems that achieve resolutions of $1 \mu m$ or less. Such imaging system would dramatically extend the application of neutron imaging. For such purposes a coded source imaging system is under development. The current challenge is to reduce artifacts in the reconstructed coded source images. Artifacts are generated by non-uniform illumination of the source, gamma rays, dark current at the imaging sensor, and system noise from the reconstruction kernel. In this paper, we describe how to pre-process the coded signal to reduce noise and non-uniform illumination, and how to reconstruct the coded signal with three reconstruction methods correlation, maximum likelihood estimation, and algebraic reconstruction technique. We illustrates our results with experimental examples.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental approaches for the development of gamma spectroscopy well logging system

This article discusses experimental approaches for the development of gamma spectroscopy well logging system. Considering the size of borehole sonde, we customize 2 x 2 inches inorganic scintillators and the system including high voltage, preamplifier, amplifier and multichannel analyzer (MCA). The calibration chart is made by test using standard radioactive sources so that the measured count rates are expressed by energy spectrum. Optimum high-voltage supplies and the measurement parameters of each detector are set up by experimental investigation. Also, the responses of scintillation detectors have been examined by analysis according to the distance between source and detector. Because gamma spectroscopy well logging needs broad spectrum, high sensitivity and resolution, the energy resolution and sensitivity as a function of gamma ray energy are investigated by analyzing the gamma ray activities of the radioactive sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new measurement method of tritiated water with no radioactive waste- for monitoring post - 15050

A new measurement method has been developed by using a conventional liquid scintillation counter (LSC) with plastic scintillator pellets (PS-pellets) which is used as an alternative material of liquid scintillator. The measurement efficiency (%=cpm/dpm x 100) of PS-pellets with a conventional LSC is as high as using a liquid scintillator. Measurement efficiency of tritiated water was more than 50% by using PS-pellets for LSC without liquid scintillator. Qualitative and quantitative analysis were possible by using PS-pellets for LSC, because the PS-pellets method showed good linearity between the activity and count rate. Also, an end point of a spectrum showed a maximum energy of a radionuclide when one channel estimated 0.5 keV. The PS-pellets were reusable by dipping them in 5% soapsuds of hot water for more than overnight except for a case of measuring for a long elapsed time. So, no radioactive waste of liquid scintillator and PS-pellets is produced with this method.We designed a new field monitor and a monitoring post. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Guide for SDEC Set up

The instrument has four collection vials that must be filled with ethylene glycol before operation. Each of the four vials should be labeled 1 through 4 and the empty weights recorded. Fill each vial with 80 mL of ethylene glycol and record the weight again. In order for the instrument to operate properly, the collection vials should always have less than 160 mL of total liquid in them. After completing a sample run, remove the collection vials, use a transfer pipette to remove any liquid that might still be on the air paddler, wipe off any condensation from the exterior of the collection vial and record weight. From the instrument, record the ending volume and the time of operation. The solution mixed in the scintillation vial will be 2 ml of a 95% to 50% ethylene glycol to water mixture. To determine the efficiency of counting at all of these concentrations, a series of vials should be set up that consist of 18 ml of Ultima Gold LLT cocktail mixed with standard, regular deionized water and ethylene glycol. The efficiency curve should be counted in the 'Low Level' count mode with the Luminescence Correction ON and the Color Quench Correction ON. Once the tSIE values are determined, chart the cpm against the tSIE numbers and find the best fit for the data. The resulting equation is to be used to converting tSIE values from the collection vials to efficiency. To determine the background cpm value of the ethylene glycol, count a 2 ml sample of ethylene glycol with 18 ml of Ultima Gold for 100 minutes. To determine the total activity of the sample, take two 2 ml aliquots of sample from the first vial and place in separate scintillation vials. Record the weight of each aliquot. Determine the percentage of total sample each aliquot represents by dividing the aliquot weight by the total solution weight from the vial. Also, determine the percentage of ethylene glycol in the sample by dividing the initial solution weight by the final solution weight and multiplying by 100. Add 18 ml of Ultima Gold to each vial and proceed to count for 100 minutes in a 'Low Level' count mode. Before performing a calculation on the dpm value of each aliquot, a subtraction should be made for the background count rate of the ethylene glycol. Based on the background cpm, multiply the background cpm value by the percentage of ethylene glycol in the collection vial. Once the background value is subtracted, calculate the dpm value of the sample based on the tSIE conversion to efficiency. This will produce a dpm value. To convert this to a total activity of the sample, divide the aliquot dpm value by the decimal percentage of total sample the aliquot represents. This gives the total activity of the sample solution. Take the average of both aliquots as a final result. To convert the total activity from the solution in vial one to activity in air, an empirical formula is used to convert activity/gram from vial one to total activity introduced into the system. After calculation the final result for the vial, divide the total by the mass of the sample in vial one. This gives dpm/g (labeled C{sub m}). To convert this to total dpm measured, C = (128.59 * Cm + 10.837)/V Where: C = Tritium concentration in air (dpm/m{sup 3}) C{sub m} = measured tritium concentration from vial 1 (dpm/g) V = Volume of air sampled through instrument (m{sup 3}). C is the final value of tritium concentration in air.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗