Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL CONDITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Self-powered Wireless Dual-mode Langasite Sensor for Pressure/Temperature Monitoring of Nuclear Reactors

Safety issues in nuclear power plants are of extreme importance. Numerous sensors are used within nuclear power plants for sensing and monitoring of its critical operation parameters. As currently implemented, during massive losses of power across the plant in accidents, the backup batteries for the monitoring sensors will ultimately be drained and can cease to operate. The overall objective of this NEUP project is to develop a novel self-powered wireless hybrid sensor which can accurately monitor both pressure and temperature using a single device, even in the extreme harsh environments of severe nuclear accidents, without the requirement of external electricity. At Virginia Tech side, a heat pipe assisted thermoelectric generator (TEG) energy harvester and associated power management and data transmission circuits were developed. The energy harvester can produce electrical power continuously, even in loss of plant and external power situations, providing power for important data transmission for accident diagnosis. The self-powered sensing system could be integrated directly onto key nuclear components including pipes, pump housings, heat exchangers, reactor vessels, and shielding structures inside and outside of the reactor core. Two TEG based energy harvesters which can work in relatively low (50-250 ºC) and high temperature ranges (250-350 ºC) were established and tested. In the prototypes, heat pipes were introduced to reduce the heat resistances of the device at the hot and cold ends. The power output of the heat pipe assisted TEG module is 2.22 W, which is 6 times more than one using an aluminum rod. In-lab tests showed that these devices canmeet the requirement to power the sensors and circuit during normal and off-normal conditions.Amodel was then built to analyze the thermal network in the energy harvester, and was used to optimize its performance and reduce its geometry size. The design and testing of the vibrational energy harvester were completed. The harvester, has shown to effectively increase the vibrational potential of the main coolant pump, though it has been shown that thermal energy has a much higher potential for the powering of sensors. In this project, a self-start charger circuit for the energy harvester was designed to regulate and manage the power. An energy storage element was incorporated into the energy harvesting module for sensors and wireless transceivers in an off-normal situation. The signal conditioning and wireless communication electronic circuits were developed and tested in the lab. An important consideration for an energy harvester within a nuclear power plant is the level of radiation it will encounter during operation. The two main sources of radiation in a nuclear power plant are gamma and neutron radiation. Aradiation experiment was conducted in the Westinghouse Electric Company during which the prototypes were placed in a 106 rad radiation environment to test their ability to operate in the extreme environment. The results showed that this level of radiation had little effect on the performance of the TEGmaterial and heat pipe heat exchanging system. Its influence on the circuit was still under research, however the need for more development on radiation hardened electronics is needed. Pressure measurement based on piezoelectric crystal resonators has advantages over the commercially available methods like capacitive, electromagnetic, optical, potentiometric, and piezo resistive strain gauges. Since the output of piezoelectric based sensors are digital in format, it has a very high resolution, high accuracy, and long-term stability. Quartz is one of the commonly used piezoelectric material in digital pressure sensors design. This material is elastic in nature, providing high stability, high repeatability, high elasticity, repeatable mechanical behavior for many cycles of operation, and is free of hysteresis. The quartz resonator has a high Q, which means that very high vibration can be driven with the very low electric power. Langasite (LGS) is a new promising piezoelectric material that combines the advantageous properties of quartz with a better performance at high temperatures. LGS will not undergo any phase transitions up to its melting temperature of 1473 C, and hence, the application of Langasite in measuring pressure at high temperatures is promising. In this project, the design and fabrication of the piezo oscillator crystal for temperature and pressure measurement has been completed. The entire sensor has been fabricated and tested to see its sensitivity to temperature and pressure changes. The design and optimization of the radiation shielding systems that can effective protect the duel-mode Langasite sensor inside reactor core were demonstrated. To maximize the radiation shielding effectiveness, different types of materials are investigated based upon recent developments of radiation shielding systems including aluminum + Boron carbide and bismuth borosilicate glass B2O3 in addition to tungsten/B4C. New materials based upon metatheses is included as potential shielding to mitigate neutron fluencies. The radiation shielding effectiveness of selected composites are evaluated within a broader neutron spectrum from thermal, epithermal, fast (1 MeV) and 15 MeV neutrons. Performance analysis was also conducted to evaluate the effects of selected composite systems.Aconceptual design was also proposed for the packaging and integration of the radiation shielding system with the sensor, and its applicability within the reactor core was discussed. At end of the project, all components necessary for a complete sensing and monitoring system, including a langasite sensor, electrodes, the TEG harvester, an energy storage device, and power management and transmission electronics were integrated to demonstrate feasibility in powering the sensor. Finally, integration of each component into a full package, and a full demonstration were done.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Benchmark Gamma Spectroscopy Measurements of Uranium Hexafluoride in Aluminmum Pipe with a Sodium Iodide Detector

The expected increased demand in fuel for nuclear power plants, combined with the fact that a significant portion of the current supply from the blend down of weapons-source material will soon be coming to an end, has led to the need for new sources of enriched uranium for nuclear fuel. As a result, a number of countries have announced plans, or are currently building, gaseous centrifuge enrichment plants (GCEPs) to supply this material. GCEPs have the potential to produce uranium at enrichments above the level necessary for nuclear fuel purposes-enrichments that make the uranium potentially usable for nuclear weapons. As a result, there is a critical need to monitor these facilities to ensure that nuclear material is not inappropriately enriched or diverted for unintended use. Significant advances have been made in instrument capability since the current International Atomic Energy Agency (IAEA) monitoring methods were developed. In numerous cases, advances have been made in other fields that have the potential, with modest development, to be applied in safeguards applications at enrichment facilities. A particular example of one of these advances is the flow and enrichment monitor (FEMO). (See Gunning, J. E. et al., 'FEMO: A Flow and Enrichment Monitor for Verifying Compliance with International Safeguards Requirements at a Gas Centrifuge Enrichment Facility,' Proceedings of the 8th International Conference on Facility Operations - Safeguards Interface. Portland, Oregon, March 30-April 4th, 2008.) The FEMO is a conceptual instrument capable of continuously measuring, unattended, the enrichment and mass flow of {sup 235}U in pipes at a GCEP, and consequently increase the probability that the potential production of HEU and/or diversion of fissile material will be detected. The FEMO requires no piping penetrations and can be installed on pipes containing the flow of uranium hexafluoride (UF{sub 6}) at a GCEP. This FEMO consists of separate parts, a flow monitor (FM) and an enrichment monitor (EM). Development of the FM is primarily the responsibility of Oak Ridge National Laboratory, and development of the EM is primarily the responsibility of Los Alamos National Laboratory. The FM will measure {sup 235}U mass flow rate by combining information from measuring the UF{sub 6} volumetric flow rate and the {sup 235}U density. The UF{sub 6} flow rate will be measured using characteristics of the process pumps used in product and tail UF{sub 6} header process lines of many GCEPs, and the {sup 235}U density will be measured using commercially available sodium iodide (NaI) gamma ray scintillation detectors. This report describes the calibration of the portion of the FM that measures the {sup 235}U density. Research has been performed to define a methodology and collect data necessary to perform this calibration without the need for plant declarations. The {sup 235}U density detector is a commercially available system (GammaRad made by Amptek, www.amptek.com) that contains the NaI crystal, photomultiplier tube, signal conditioning electronics, and a multichannel analyzer (MCA). Measurements were made with the detector system installed near four {sup 235}U sources. Two of the sources were made of solid uranium, and the other two were in the form of UF{sub 6} gas in aluminum piping. One of the UF{sub 6} gas sources was located at ORNL and the other at LANL. The ORNL source consisted of two pipe sections (schedule 40 aluminum pipe of 4-inch and 8-inch outside diameter) with 5.36% {sup 235}U enrichment, and the LANL source was a 4-inch schedule 40 aluminum pipe with 3.3% {sup 235}U enrichment. The configurations of the detector on these test sources, as well as on long straight pipe configurations expected to exist at GCEPs, were modeled using the computer code MCNP. The results of the MCNP calculations were used to define geometric correction factors between the test source and the GCEP application. Using these geometric correction factors, the experimental 186 keV counts in the test geometry were extrapolated to the expected GCEP geometry, and calibration curves were developed. A unique method to analyze the measurement was also developed that separated the detector spectrum into the five detectable decay gamma rays emitted by {sup 235}U in the 120 to 200 keV energy range. This analysis facilitated the assignment of a consistent value for the detector counts originating from {sup 235}U decays at 186 keV. This value is also more accurate because it includes the counts from gamma energies other than 186 keV, which results in increased counting statistics for the same measurement time. The 186 keV counts expected as a function of pressure and enrichment are presented in the body of this report. The main result of this research is a calibration factor for 4-inch and 8-inch schedule 40 aluminum pipes. For 4-inch pipes, the {sup 235}U density is 0.62 {sup 235}U g/m{sup 3} per each measured 186 keV count.

March-Leuba, Jose A↗

Video synchronization processor overcomes poor signal-to-noise ratio

Video synchronization processor overcomes poor signal-to-noise ratio which occurs during adverse signal conditions caused by flame attenuation, antenna pattern nulls, and near-horizon tracking. The system maintains sync lock far below the point where excessive noise would normally render the video useless.

Webb, D. L.↗

On-the-shaft data systems for rotating engine components

Two rotating data systems for engine component testing which demonstrate the techniques of on-the-shaft microelectronic signal conditioning and rotary transformer power- and data-transfer are described. (1) A digital data system provides 69 channels of 1100 C maximum thermocouple data with less than 0.5 percent error from a turbine test rig rotating at speeds up to 9000 rpm. (2) An analog data system amplifies and transfers 72 channels of dynamic strain data with less than 5 percent error from a compressor rig at speeds above 14,000 rpm.

Lesco, D. J.↗

Modularized instrument system for turbojet engine test facilities

A modular instrument system is being developed to handle the many data channels encountered in turbojet engine testing. Each module contains a group of transducers and all the signal conditioning multiplexing, and digitizing electronics necessary for direct interface with a digital computer. The digital interface within each module is the same for all modules; in addition, each module provides a controlled environment for its contents. A minicomputer in the control room gathers the data, performs on-line calculation and display, and interfaces with a shared recording and computing system. The advantages of this system are: (1) reduced manpower for system installation, setup, and checkout; (2) standardized equipment interfaces; (3) increased reliability through automatic system testing and minimization of manual adjustments; and (4) reduced cost through minimization of wiring and simplification of control room display.

Nieberding, W. C.↗

Signal conditioner for potentiometer type transducers

Low cost method is described for signal conditioning of pot-type transducers utilizing printed circuitry. Conditioner fits into standard rack, accommodates 56 channels, and can be operated by one attendant.

Armentrout, E. C.↗

The programming language HAL: A specification

HAL accomplishes three significant objectives: (1) increased readability, through the use of a natural two-dimensional mathematical format; (2) increased reliability, by providing for selective recognition of common data and subroutines, and by incorporating specific data-protect features; (3) real-time control facility, by including a comprehensive set of real-time control commands and signal conditions. Although HAL is designed primarily for programming on-board computers, it is general enough to meet nearly all the needs in the production, verification and support of aerospace, and other real-time applications.

Source record↗

A multichannel electromagnetic flowmeter telemetry system.

An eight-channel biomedical telemetry system provides four channels of blood flow measurements in addition to blood-pressure and EKG data. Emphasis is placed on the amplifiers and signal conditioning circuitry required for interfacing of the electromagnetic flow transducers with the transmission and modulation subsystems. The large number of data channels permits measurement of flow distribution as well as total cardiac output. The batteries and electronics for four channels (blood flow) weigh about 500 g and have a volume of 250 cu cm.

Fryer, T. B.↗

Development of a long wavelength spectrometer for the 24-channel multispectral scanner: Instructions for installation, start-up, and adjustment

The basic information is presented, which is required for start-up and operation of two long-wavelength focal-plane and cooler assemblies, including the amplifiers and temperature control systems. The focal plane systems, referred to as the long wavelength spectrometer (LWS) were developed for direct replacement of Arrays 3 and 4 into the multispectral scanner presently being operated by the NASA Manned Spacecraft Center Facility, and Laboratory Support Branch. The equipment is comprised of two major sub-assemblies: Array 3 with three indium antimonide detector channels and Array 4 with seven mercury doped Germanium detector channels. Each array is mounted on a cryogenic cooler and includes the vacuum housings, mounting hardware (x, y, z translation and rotation stages) and detector signal conditioning, temperature control and monitoring electronics. The two arrays were designed to operate independently and do not share common equipment (viz power supplies, housings, mounts, etc.).

Source record↗

On-the-shaft data systems for rotating engine components

Two rotating data systems for engine component testing, which demonstrate the techniques of on-the-shaft microelectronic signal conditioning and rotary transformer power- and data-transfer, are described. These systems are a digital data system which provides 69 channels of 1100 C maximum thermocouple data with less than 0.5% error from a turbine test rig rotating at speeds up to 9000 rpm and an analog data system which amplifies and transfers 72 channels of dynamic strain data with less than 5% error from a compressor rig at speeds above 14,000 rpm.

Lesco, D. J.↗

Modularized instrument system for turbojet engine test facilities

A new modular instrument system is being developed to handle the many channels of data commonly encountered in turbojet engine testing. Each module contains a group of transducers and all the signal conditioning, multiplexing, and digitizing electronics necessary for direct interface with a digital computer. The digital interface within each module is the same for all modules. Each module provides a controlled environment for its contents. A minicomputer in the control room gathers the data, performs some on-line calculation and display, and interfaces with a shared recording and computing system. The advantages of this system are (1) reduced manpower for system installation, setup, and checkout; (2) standardized equipment interfaces; (3) increased reliability through automatic system testing and through minimization of manual adjustments; and (4) reduced cost through minimization of wiring and simplification of control room display.

Nieberding, W. C.↗

High-temperature capacitive strain measurement system

Capacitive strain gage and signal conditioning system measures stress-induced strain and cancels thermal expansion strain at temperatures to 1,500 F (815 C). Gage does not significantly restrain or reinforce specimen.

Wilson, E. J.↗

Voltage monitoring system

System serves as central station which can monitor voltage variations through transmission lines connnected to equipment scattered in different locations. Voltage-controlled oscillator is optional. It is used in some systems to condition signal to make it compatible with certain types of oscillographs.

Canicatti, C. L.↗

A computer-controlled, on-board data acquisition system for wind-tunnel testing

A computer-controlled data acquisition system has been developed for the 40x80-foot wind tunnel at Ames Research Center. The system, consisting of several small onboard units installed in the model and a data-managing, data-displaying ground station, is capable of sampling up to 256 channels of raw data at a total sample rate of 128,000 samples/sec. Complete signal conditioning is contained within the on-board units. The sampling sequence and channel gain selection is completely random and under total control of the ground station. Outputs include a bar-graph display, digital-to-analog converters, and digital interface to the tunnel's central computer, an SEL 840MP. The system can be run stand-alone or under the control of the SEL 840MP.

Finger, H. J.↗

An integrated PCM data system for full scale aeronautics testing

An integrated PCM data system is being developed at Ames Research Center to gather test data on advanced STOL propulsive lift, VTOL, rotary wing, and V/STOL control systems concepts as they pass through wind-tunnel, test-stand, flight-simulator and flight-test phases. Identical airborne signal conditioning and PCM encoding is used on test aircraft and wind tunnel models. An 80,000 word/second PCM installation will be the first all PCM-instrumented rotary wing development project. The system uses both dedicated and time-shared computers for fast data analysis with maximum use of resources. This system development shows one way to bring separate data user groups together over a common data base, while sharing computing resources for minimum cost.-

Reynolds, D. R.↗

Power processing system for a 200 watt communication satellite transmitter

A power processing system (PPS) for a communication satellite, high power (200W RF) multi-stage depressed collector, 12 GHz, traveling wave tube, is described. The PPS converts spacecraft bus power at a nominal voltage of 76 Vdc to the levels necessary for operating a ten-collector coupled cavity TWT requiring approximately 500 watts of input power. Regulated voltages of up to -11.3K Vdc are provided along with command, protection and telemetry signal conditioning circuits. Power processor interface requirements are set forth and a block diagram illustrating the basic approach utilized is presented. Overall performance, design characteristics and unique features are discussed. Thermal and mechanical interface requirements impacting on PPS design are described as well as the thermal control technique utilized for the overall PPS/TWT assembly.

Farber, B. F.↗