At least 217 records · Page 12

Dual-Pulse Pulse Position Modulation (DPPM) for Deep-Space Optical Communications: Performance and Practicality Analysis

Due to its simplicity and robustness against wavefront distortion, pulse position modulation (PPM) with photon counting detector has been seriously considered for long-haul optical wireless systems. This paper evaluates the dual-pulse case and compares it with the conventional single-pulse case. Analytical expressions for symbol error rate and bit error rate are first derived and numerically evaluated, for the strong, negative-exponential turbulent atmosphere; and bandwidth efficiency and throughput are subsequently assessed. It is shown that, under a set of practical constraints including pulse width and pulse repetition frequency (PRF), dual-pulse PPM enables a better channel utilization and hence a higher throughput than it single-pulse counterpart. This result is new and different from the previous idealistic studies that showed multi-pulse PPM provided no essential information-theoretic gains than single-pulse PPM.

Li, Jing↗

Evaluation of a virtual phase charged-coupled device as an imaging X-ray spectrometer

The X-ray response of an 800 x 800 Texas Instruments virtual phase charge-coupled device (CCD) has been measured in the range 1-8 keV. In the single-photon counting mode, excellent energy resolution (approximately 250 eV FWHM is found for single-pixel Fe-55 X-ray events at a spatial resolution of 15 microns. The detector quantum efficiency for all events is 65% at 2.3 keV (S K line) and approximately 34% at 5.9 keV (Mn K line from Fe-55). The CCD response is linear in energy to a few percent over the 1-8 keV energy range. These results demonstrate that virtual phase CCDs are superior imaging X-ray spectrometers with applications for X-ray astronomy and laboratory plasma research.

Stern, R. A.↗

Preliminary design report, Large Space Telescope OTA/SI Phase B study: High speed area photometer

A photometer is examined which combines several features from separate instruments into a single package. The design presented has both point and area photometry capability with provision for inserting filters to provide spectral discrimination. The electronics provide for photon counting mode for the point detectors and both photon counting and analog modes for the area detector. The area detector also serves as a target locating device for the point detectors. Topics discussed include: (1) electronic equipment requirements, (2) optical properties, (3) structural housing for the instrument, (4) motors and other mechanical components, (5) ground support equipment, and (6) environment control for the instrument. Engineering drawings and block diagrams are shown.

Source record↗

Implementation of Complex Signal Processing Algorithms for Position-Sensitive Microcalorimeters

We have recently reported on a theoretical digital signal-processing algorithm for improved energy and position resolution in position-sensitive, transition-edge sensor (POST) X-ray detectors [Smith et al., Nucl, lnstr and Meth. A 556 (2006) 2371. PoST's consists of one or more transition-edge sensors (TES's) on a large continuous or pixellated X-ray absorber and are under development as an alternative to arrays of single pixel TES's. PoST's provide a means to increase the field-of-view for the fewest number of read-out channels. In this contribution we extend the theoretical correlated energy position optimal filter (CEPOF) algorithm (originally developed for 2-TES continuous absorber PoST's) to investigate the practical implementation on multi-pixel single TES PoST's or Hydras. We use numerically simulated data for a nine absorber device, which includes realistic detector noise, to demonstrate an iterative scheme that enables convergence on the correct photon absorption position and energy without any a priori assumptions. The position sensitivity of the CEPOF implemented on simulated data agrees very well with the theoretically predicted resolution. We discuss practical issues such as the impact of random arrival phase of the measured data on the performance of the CEPOF. The CEPOF algorithm demonstrates that full-width-at- half-maximum energy resolution of < 8 eV coupled with position-sensitivity down to a few 100 eV should be achievable for a fully optimized device.

Smith, Stephen J.↗

A method for correcting aspect solution errors in ROSAT HRI observations of compact sources

X-ray point sources observed with the ROSAT High Resolution Imager (HRI) often appear elongated over scales of approximately 5 sec-10 sec from the image core. This elongation has been attributed to errors in the attitude correction as the satellite is wobbled during the observations, and affects sources with both soft and hard X-ray spectra. In this paper, I report the results of an attempt to rid a high signal-to-noise observation of the soft X-ray point source HZ 43 of its characteristic elongation. I divided the observation into 181 separate images, each containing photons from only a small region on the detector through which the source passed during the satellite's wobble. By measuring the positions of the individual image centroids, I found clear evidence for systematic offsets from a common mean by up to approximately +/- 3 sec in both right ascension and declination as a function of phase in the satellite wobble. Shifting the subimages to a common center and then restacking them into a single image measurably improved the symmetry of the point-spread function. HRI observations are wobbled primarily to smooth out variations in the pixel-to-pixel sensitivity of the detector and also to extend the lifetime of the microchannel plates in the detector since these decay at a given location as a function of the number of photons detected. However, the elongations introduced by the aspect errors inhibit the identification of possible extended X-ray emission associated with sources such as pulsars and active galactic nuclei. In light of these results, I suggest that until the aspect errors are understood, observations of compact sources, where this effect may be important, should not be wobbled.

Morse, Jon A.↗

Performance and materials aspects of Ge:Be photoconductors

Ge:Be photoconductors were developed for low photon background applications in the 30 to 50 MM wavelength region. These detectors provide higher responsivity and lower noise equivalent power (NEP) than the Ge:Ga detectors currently operating in this wavelength range. Beryllium doped single crystals were grown by the Czochralski method from a carbon susceptor under a vacuum of approx. one million torr. An optimum detective quantum efficiency of 46% at a background flux of 1.5 x 10 to the 8th power photons/second (7 x 10 to the 13th power W) was reported. Ge:Be detector performance is strongly influenced by the absolute concentrations and the concentration ratio of residual shallow donors and shallow acceptors.

Haegel, N. M.↗

Performance and materials aspects of Ge:Be photoconductors

Ge:Be photoconductors have been developed for low photon background applications in the 30 - 50 micron wavelength region. These detectors provide higher responsivity and lower noise equivalent power (NEP) than the Ge:Ga detectors currently operating in this wavelength range. Beryllium-doped single crystals were grown by the Czochralski method from a carbon susceptor under a vacuum of approximately 10 to the -6th torr. An optimum detective quantum efficiency of 46 percent at a background flux of 1.5 x 10 to the 8th photons/second (7 x 10 to the -13th W is reported. Ge:Be detector performance is strongly influenced by the absolute concentrations and the concentration ratio of residual shallow donors and shallow acceptors.

Haegel, N. M.↗

Simplified Architecture for Precise Aiming of a Deep-Space Communication Laser Transceiver

The simplified architecture is a minimal system for a deep-space optical communications transceiver. For a deepspace optical communications link the simplest form of the transceiver requires (1) an efficient modulated optical source, (2) a point-ahead mechanism (PAM) to compensate for two-way light travel, (3) an aperture to reduce the divergence of the transmit laser communication signal and also to collect the uplink communication signal, and (4) a receive detector to sense the uplink communication signal. Additional components are introduced to mitigate for spacecraft microvibrations and to improve the pointing accuracy. The Canonical Transceiver implements this simplified architecture (see figure). A single photon-counting smart focal plane sensor combines acquisition, tracking, and forward link data detection functionality. This improves optical efficiency by eliminating channel splits. A transmit laser blind sensor (e.g. silicon with 1,550-nm beam) provides transmit beam-pointing feedback via the two-photon absorption (TPA) process. This vastly improves the transmit/receive isolation because only the focused transmit beam is detected. A piezoelectric tiptilt actuator implements the required point-ahead angle. This point-ahead mechanism has been demonstrated to have near zero quiescent power and is flight qualified. This architecture also uses an innovative 100-mHz resonant frequency passive isolation platform to filter spacecraft vibrations with voice coil actuators for active tip-tilt correction below the resonant frequency. The canonical deep-space optical communications transceiver makes synergistic use of innovative technologies to reduce size, weight, power, and cost. This optical transceiver can be used to retire risks associated with deep-space optical communications on a planetary pathfinder mission and is complementary to ongoing lunar and access link developments.

Ortiz, Gerard G.↗

High background photon counting lidar

Photon counting with lidar returns is usually limited to low light levels, while wide dynamic range is achieved by counting for long times. The broad emission spectrum of inexpensive high-power semiconductor lasers makes receiver filters pass too much background light for traditional photon counting in daylight. Very high speed photon counting is possible, however, at more than 500 MHz which allows the construction of eyesafe lidar operating in the presence of bright clouds. Detector improvements are possible to count to 20 GHz producing a single shot dynamic range of ten decades.

Lentz, W. J.↗

Transition radiation effects in superconducting granules

The paper examines the use of a superheated superconducting suspension as a transition radiation detector of relativistic charged particles. The suspensions would also be used for detecting low-energy X-ray photons. The DESY experiment for developing such a superconducting detector has been carried out at a 7 GeV electron synchrotron. The detection is shown to be based on the recordable flipping of the state of a single superconducting grain.

Drukier, A. K.↗

MOD: An Organic Detector for the Future Exploration of Mars

The Mars Organic Detector (MOD) is designed to assess whether organic compounds, possibly associated with life, are present in Martian rock and soil samples. MOD has a detection limit that is at least two orders of magnitude more sensitive than the Viking GCMS. MOD is focused on detecting amino acids, amines and PAH (polycyclic aromatic hydrocarbons). Amino acids play an essential role in biochemistry on Earth and PAH are widespread throughout the universe and can provide an indication of the delivery of meteoritic organic material to Mars. The advantage of MOD is the absence of wet chemistry and its simple and robust design. The sample will be extracted from the mineral matrix (0.1 - 1 g of rock-powder) using sublimation and analyzed with a fluorescence detector. The isolation method is based on the fact that amino acids and PAH are volatile at temperatures greater than 150C. The fluorescence detection scheme is based on UV excitation with LED's, optical filters, PrN diode photon detector and a sample calibration reservoir. Fluorescamine is used as a fluorescing reagent for amino acids and amines, while PAH are naturally fluorescent. There is no sample preparation required and the turnaround time for a single analysis is on the order of minutes.

Kminek, G.↗

In Situ Mineralogical Analysis of Planetary Materials Using X-Ray Diffraction and X-Ray Fluorescence

Remote observations of Mars have led scientists to believe that its early climate was similar to that of the early Earth, having had abundant liquid water and a dense atmosphere. One of the most fascinating questions of recent times is whether simple bacterial life developed on Mars (as it did on the Earth) during this early element period. Analyses of SNC meteorites have broadened considerably our knowledge of the chemistry of certain types of Martian rocks, underscoring the tantalizing possibility of early hydrothermal systems and even of ancient bacterial life. Detailed analyses of SNC meteorites in Terrestrial laboratories utilize the most sophisticated organic, isotopic and microscopic techniques in existence. Indeed; it is unlikely that the key biogenic indicators used in McKay et al (ibid) could be identified by a remote instrument on the surface of Mars. As a result, it is probable that any robotic search for evidence of an ancient Martian biosphere will have as its focus the identification of key minerals in likely host rocks rather than the direct detection of organic or isotopic biomarkers. Even on a sample return mission, mineralogical screening will be utilized to choose the most likely candidate rocks. X-ray diffraction (XRD) is the only technique that can provide a direct determination of the crystal structures of the phases present within a sample. When many different crystalline phases are present, quantitative analysis is better constrained if used in conjunction with a determination of elemental composition, obtainable by X-ray fluorescence (XRF) using the same X-ray source as for XRD. For planetary surface analysis, a remote instrument combining XRD and XRF could be used for mineralogical characterization of both soils and rocks. We are designing a remote XRD/XRF instrument with this objective in mind. The instrument concept pays specific attention to constraints in sample preparation, weight, volume, power, etc. Based on the geometry of a pinhole camera (transmission geometry, flat two-dimensional detector perpendicular to the direct beam), the instrument (which we call CHEMIN, for Chemistry and Mineralogy) uses an X-ray sensitive CCD detector which will allow concurrent positional and energy-dispersive analysis of collected photons. Thus XRF (energy) and XRD (geometry) analysis of transmitted X-rays will be performed at the same time. Tests performed with single minerals and simple mixtures give promising results. Refinements of the prototype promise interpretable results on complex samples.

Sarrazin, P.↗

Record Low NEP in the Hot-Electron Titanium Nanobolometers

We are developing hot-electron superconducting transition-edge sensors (TES) capable of counting THz photons and operating at T = 0.3K. We fabricated superconducting Ti nanosensors with Nb contacts with a volume of approx. 3x10(exp -3) cu microns on planar Si substrate and have measured the thermal conductance due to the weak electron-phonon coupling in the material G = 4x10(exp -14) W/K at 0.3 K. The corresponding phonon-noise NEP = 3x10(exp -19) W/Hz(sup 1/2). Detection of single optical photons (1550nm and 670nm wavelength) has been demonstrated for larger devices and yielded the thermal time constants of 30 microsec at 145 mK and of 25 microsec at 190 mK. This Hot-Electron Direct Detector (HEDD) is expected to have a sufficient energy resolution for detecting individual photons with (nu) > 1 THz where NEP approx. 3x10(exp -20) W/Hz(sup 1/2) is needed for spectroscopy in space.

transition edge sensors↗

Resolving Wave-Particle Duality Could Accelerate the Mass Production of Quantum Computers

Quantum computers, hypothesized in 1980s, use concepts of superposition and entanglement phenomena. Although theoretical propositions and associated search algorithms for accurate measurements are being generated, the development of practical quantum computers themselves are advancing very slowly requiring enormous time and investments. The underlying concepts of a quantum computer are not new to the optical domain. However, the crucial enabling concepts of Entanglement and Superposition Principle are remaining clouded under the unresolved postulates, Wave-Particle Duality (WPD), and Wave Packet Reduction (WPR), implicating incompleteness in the interpretations of the mathematical formalism behind Quantum Mechanics. The WPD debate started during late1600 between Newton and Huygens. Young’s resolution of WPD through his double-slit experiment in 1802 was effectively overturned by Einstein’s interpretation of photoelectric effect as due to “indivisible light quanta”. However, Einstein disowned his “light quanta” postulate shortly before his death in1955, even though it had earned him the Nobel Prize. We resolve WPD by synthesizing Newton’s and Maxwell’s concepts and assume atoms do emit quanta but propagate as time-finite exponential pulses. This assumption also resolves WPR for light-matter interaction with the assumption that Schrodinger’s ψ represents atom’s internal dipolar amplitude stimulations. This over-turns Born’s interpretation that ψ only represents the abstract mathematical probability amplitude, rather than the physical “internal amplitude stimulation” of the quantum entity. However, our concept of atomic pulse emission forces us to re-derive the expression for the N-slit grating-spectrometer response since the classical derivation uses CW light, which does not exist. This pulsespectrometric response function strengthens our postulate since the grating response to the exponential pulse appears to be the convolution of a Lorentzian spectrum with the classical CW response function of the grating. The Fourier Transform of an exponential function is Lorentzian and QM predicts spontaneous emission line width to be Lorentzian. Then, conceptually one can extend the grating-expression (with N=2) to get the double-slit pattern. This approach preserves the classical causality that each of the two slits, like the N-signals out of a grating, are physically real and jointly stimulate the quantum detector array at the far field to generate the “Local” cosine fringes. The detector array executes the square modulus operation on its imposed dipolar amplitude stimulation and absorbs the necessary energy to fill up their quantum cups. Hence the double-slit pattern must also be “Local”, just as the N-slit grating spectrum is generated locally at the exit spectral-plane of the spectrometer. This removes the need to believe that “single photons” mysteriously generate the double slit pattern. Quantum computers, hypothesized in 1980s, use concepts of superposition and entanglement phenomena. Although theoretical propositions and associated search algorithms for accurate measurements are being generated, the development of practical quantum computers themselves are advancing very slowly requiring enormous time and investments. The underlying concepts of a quantum computer are not new to the optical domain. However, the crucial enabling concepts of Entanglement and Superposition Principle are remaining clouded under the unresolved postulates, Wave-Particle Duality (WPD), and Wave Packet Reduction (WPR), implicating incompleteness in the interpretations of the mathematical formalism behind Quantum Mechanics. The WPD debate started during late1600 between Newton and Huygens. Young’s resolution of WPD through his double-slit experiment in 1802 was effectively overturned by Einstein’s interpretation of photoelectric effect as due to “indivisible light quanta”. However, Einstein disowned his “light quanta” postulate shortly before his death in1955, even though it had earned him the Nobel Prize. We resolve WPD by synthesizing Newton’s and Maxwell’s concepts and assume atoms do emit quanta but propagate as time-finite exponential pulses. This assumption also resolves WPR for light-matter interaction with the assumption that Schrodinger’s ψ represents atom’s internal dipolar amplitude stimulations. This over-turns Born’s interpretation that ψ only represents the abstract mathematical probability amplitude, rather than the physical “internal amplitude stimulation” of the quantum entity. However, our concept of atomic pulse emission forces us to re-derive the expression for the N-slit grating-spectrometer response since the classical derivation uses CW light, which does not exist. This pulsespectrometric response function strengthens our postulate since the grating response to the exponential pulse appears to be the convolution of a Lorentzian spectrum with the classical CW response function of the grating. The Fourier Transform of an exponential function is Lorentzian and QM predicts spontaneous emission line width to be Lorentzian. Then, conceptually one can extend the grating-expression (with N=2) to get the double-slit pattern. This approach preserves the classical causality that each of the two slits, like the N-signals out of a grating, are physically real and jointly stimulate the quantum detector array at the far field to generate the “Local” cosine fringes. The detector array executes the square modulus operation on its imposed dipolar amplitude stimulation and absorbs the necessary energy to fill up their quantum cups. Hence the double-slit pattern must also be “Local”, just as the N-slit grating spectrum is generated locally at the exit spectral-plane of the spectrometer. This removes the need to believe that “single photons” mysteriously generate the double slit pattern.

Quantum Computer↗

GaN/AlGaN Avalanche Photodiode Detectors for High Performance Ultraviolet Sensing Applications

The shorter wavelengths of the ultraviolet (UV) band enable detectors to operate with increased spatial resolution, variable pixel sizes, and large format arrays, benefitting a variety of NASA, defense, and commercial applications. AlxGa1-xN semiconductor alloys, which have attracted much interest for detection in the UV spectral region, have been shown to enable high optical gains, high sensitivities with the potential for single photon detection, and low dark current performance in ultraviolet avalanche photodiodes (UV-APDs). We are developing GaN/AlGaN UV-APDs with large pixel sizes that demonstrate consistent and uniform device performance and operation. These UV-APDs are fabricated through high quality metal organic chemical vapor deposition (MOCVD) growth on lattice-matched, low dislocation density GaN substrates with optimized material growth and doping parameters. The use of these low defect density substrates is a critical element to realizing highly sensitive UV-APDs and arrays with suppressed dark current under high electric fields.Optical gains greater than 5X10 (exp 6) with enhanced quantum efficiencies over the 350-400 nm spectral range have been demonstrated, enabled by a strong avalanche multiplication process. Furthermore, we are developing 6X6 arrays of devices to test high gain UV-APD array performance at ~355 nm. These variable-area GaN/AlGaN UV-APD detectors and arrays enable advanced sensing performance over UV bands of interest with high resolution detection for NASA Earth Science applications.

Sood, Ashok K.↗

Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE)

The mid-infrared (MIR) spectral range (3-5 μm) is of particular interest for remotely sensing gaseous molecules such as H2O, CO2, CH4, N2O, CO, NH3, and other compounds. The infrared spectra of planets, moons, comets, and asteroids are rich in information, including gas composition and surface mineralogy. Significant advances in technology have emerged for ground-based telescopes, including the higher spectral resolution permitted by cross-dispersed instruments and heterodyne techniques. New technologies offer the opportunity to break this barrier, by using solid- state photonics. In the past three years, under the NASA ROSES PICASSO program, we have been developing key components for a revolutionary MIR spectrometer: Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE), which is based on integrated photonics technology that offers ultra-small size, weight, and power (SWaP) with non-moving parts and low cost for future planetary missions. In this paper, we will describe our science and technology development progress leading to demonstrating the concept and functionalities of the PICTURE instrument. The photonic integrated circuit spectrometer (PICS) of the PICTURE instrument uses an integrated heterodyne detection scheme to significantly reduce SWaP and improve sensitivity. Our program goals are to advance the building blocks needed for the PICS, which include arrayed waveguide gratings (AWGs), quantum cascade lasers (QCLs) as local oscillators, and quantum cascade detectors (QCDs) as heterodyne detectors. In addition, we are leveraging a NASA SBIR program to develop the toolsets needed to fabricate MIR photonics lanterns (PL). The PL is a critical component that enables PICTURE to bring a signal from the collecting telescope to the PICS, which requires single optical mode inputs. PICTURE focuses on the CO spectral band at 4.6-4.8 μm that is of key importance to cometary science. We also continue to explore future instrument concepts that exploit the broad wavelength potential of the PICS design to perform spectroscopy spanning the full MIR and longwave IR (LWIR) bands. This will have wide applicability in planetary science, for example, to probe the strongest CO2, H2O, and CH4 transitions that are difficult (CH4) or impossible (CO2, H2O) to detect using Earth-based telescopes due to atmospheric opacity. Each integrated-photonics-spectrometer chip will feature a single heterodyne room-temperature laser with a wide wavelength tuning range, or multiple local-oscillator lasers for much broader spectral coverage. The fully developed PICTURE instrument will provide a cost-effective, high-resolution spectrometer for future space applications.

Anthony W Yu↗

Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE)

The mid-infrared (MIR) spectral range (3-5 μm) is of particular interest for remotely sensing gaseous molecules such as H2O, CO2, CH4, N2O, CO, NH3, and other compounds. The infrared spectra of planets, moons, comets, and asteroids are rich in information, including gas composition and surface mineralogy. Significant advances in technology have emerged for ground-based telescopes, including the higher spectral resolution permitted by cross-dispersed instruments and heterodyne techniques. New technologies offer the opportunity to break this barrier, by using solid-state photonics. In the past three years, under the NASA ROSES PICASSO program, we have been developing key components for a revolutionary MIR spectrometer: Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE), which is based on integrated photonics technology that offers ultra-small size, weight, and power (SWaP) with non-moving parts and low cost for future planetary missions. In this paper, we will describe our science and technology development progress leading to demonstrating the concept and functionalities of the PICTURE instrument. The photonic integrated circuit spectrometer (PICS) of the PICTURE instrument uses an integrated heterodyne detection scheme to significantly reduce SWaP and improve sensitivity. Our program goals are to advance the building blocks needed for the PICS, which include arrayed waveguide gratings (AWGs), quantum cascade lasers (QCLs) as local oscillators, and quantum cascade detectors (QCDs) as heterodyne detectors. In addition, we are leveraging a NASA SBIR program to develop the toolsets needed to fabricate MIR photonics lanterns (PL). The PL is a critical component that enables PICTURE to bring a signal from the collecting telescope to the PICS, which requires single optical mode inputs. PICTURE focuses on the CO spectral band at 4.6-4.8 μm that is of key importance to cometary science. We also continue to explore future instrument concepts that exploit the broad wavelength potential of the PICS design to perform spectroscopy spanning the full MIR and longwave IR (LWIR) bands. This will have wide applicability in planetary science, for example, to probe the strongest CO2, H2O, and CH4 transitions that are difficult (CH4) or impossible (CO2, H2O) to detect using Earth-based telescopes due to atmospheric opacity. Each integrated-photonics-spectrometer chip will feature a single heterodyne room-temperature laser with a wide wavelength tuning range, or multiple local-oscillator lasers for much broader spectral coverage. The fully developed PICTURE instrument will provide a cost-effective, high-resolution spectrometer for future space applications.

Anthony W Yu↗