Search NASA⌕ Search

SEARCH · Search NASA

Results for “SO(3) group”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Magnetic properties of γ-Fe 2 O 3 nanoparticles in a porous SiO 2 shell for drug delivery

A method is presented for synthesizing core–shell nanoparticles with a magnetic core and a porous shell suitable for drug delivery and other medical applications. The core contains multiple γ -Fe 2 O 3 nanoparticles (~15 nm) enclosed in a SiO 2 (~100–200 nm) matrix using either methyl (denoted TMOS- γ -Fe 2 O 3 ) or ethyl (TEOS- γ -Fe 2 O 3 ) template groups. Low-temperature Mössbauer spectroscopy showed that the magnetic nanoparticles have the maghemite structure, γ -Fe 2 O 3 , with all the vacancies in the octahedral sites. Saturation magnetization measurements revealed that the density of γ -Fe 2 O 3 was greater in the TMOS- γ -Fe 2 O 3 nanoparticles than TEOS- γ -Fe 2 O 3 nanoparticles, presumably because of the smaller methyl group. Magnetization measurements showed that the blocking temperature is around room temperature for the TMOS- γ -Fe 2 O 3 and around 250 K for the TEOS- γ -Fe 2 O 3 . Three dimensional topography analysis shows clearly that the magnetic nanoparticles are not only at the surface but have penetrated deep in the silica to form the core–shell structure.

Physics↗

Pharmacokinetics and relative bioavailability study of two cefquinome sulfate intramammary infusions in cow milk

In this study, two intramammary infusions of cefquinome sulfate were investigated for pharmacokinetics and bioavailability. Twelve lactating cows for each group were administered an effective dose of 75 mg/gland for cefquinome, with milk samples collected at various time intervals. The concentrations of cefquinome in milk at different times were determined by the UPLC-MS/MS method. Analyses of noncompartmental pharmacokinetics were conducted on the concentration of cefquinome in milk. Mean pharmacokinetic parameters of group A and group B following intramammary administration were as follows: AUC last 300558.57 ± 25052.78 ng/mL and 266551.3 ± 50654.85 ng/mL, C max 51786.35 ± 11948.4 ng/mL and 59763.7 ± 8403.2 ng/mL, T 1/2 5.69 ± 0.62 h and 5.25 ± 1.62 h, MRT 7.43 ± 0.79 h and 4.8 ± 0.78 h, respectively. Pharmacokinetic experiments showed that the relative bioavailability of group B was 88.69% that of group A. From our findings, group B (3 g: 75 mg) shows a quicker drug elimination process than group A (8 g: 75 mg), which suggests that the withdrawal period for the new formulation may be shorter.

Li, Shuang↗

LEO life testing with different charge control

The effect of charge control on the performance of Nickel-Cadmium batteries is very important. The results of three tests performed in the Battery Test Centre of ESTEC are described. Two techniques were employed: (1) the tapering method well known for space applications, and (2) the temperature derivative technique (TDT) developed by ESTEC. In addition, a comparative study has been made between the behavior of a group of 3 batteries charged and discharged in parallel compared to an identical group discharged in parallel, but charged individually. An approach of evolution laws for the main electrical characteristics of cells is presented.

Baron, F.↗

Local Distortions and Metal–Semiconductor–Metal Transition in Quasi-One-Dimensional Nanowire Compounds AV 3 Q 3 O δ (A = K, Rb, Cs and Q = Se, Te)

Metal cluster compounds have garnered renewed interest in the search for novel superconductors and topological semimetals owing to structural instabilities of metal-cluster geometries and broken symmetries. Here we synthesized needle-like crystals of the V-cluster-based quasi-one-dimensional (Q1D) materials AV 3 Q 3 O δ (A = K, Rb, Cs, Q= Se, Te) which can also be viewed as being composed of parallel nanowires. We examine how changes in their average and local structure control their electronic properties. All compounds crystallize in the TIFe 3 Te 3 -type structure (P6 3 /m space group) with infinite (V 3 )Q 3 ) - double-walled columnar chains separated by A + cations. Our single-crystal and synchrotron powder diffraction studies indicate oxygen atoms partially occupy the center site of the V 6 octahedral metal cluster cages in KV 3 Te 3 O 0.33 , RbV 3 Te 3 O 0.32 , and CsV 3 Te 3 O 0.35 , whereas KV 3 Se 3 is structurally oxygen-free. Our synchrotron X-ray pair distribution function (PDF) analyses indicate that the oxygen-free V 6 cluster octahedra in KV 3 Se 3 are highly distorted perpendicular to the chain direction even at room temperature, reducing the symmetry of the average structure from hexagonal P6 3 /m to monoclinic P2 1 /m. Our theoretical calculation supports this P2 1 /m distortion and suggests the structure further distorts to P2 1 or P2 1 /c at lower temperatures. In contrast, the oxygen-centered V-cluster in KV 3 Te 3 O 0.33 exhibits a V-3-triangle-trimerization along the chain direction. This feature is discernible from the local PDF and is consistent with lattice dynamical calculations based on density functional theory. Resistivity measurements indicate that KV 3 Se 3 exhibits metallic behavior, whereas a dramatic metal-semiconductor-metal transition emerges in KV 3 Te 3 O 6.33 , RbV 3 Te 3 O 0.32 , and CsV 3 Te 3 O 0.35 because of oxygen disorder and changes in local structure captured from our electronic structure analyses of the Fermi surface. Our investigation of the AV 3 Q 3 O 6 family demonstrates the importance of understanding local changes in structure driven by electronic instabilities, which can guide the search for new quantum materials in other low-dimensional cluster-compound materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exchange-biased quantum tunnelling of magnetization in a [Mn 3 ] 2 dimer of single-molecule magnets with rare ferromagnetic inter-Mn 3 coupling

A covalently-linked dimer of two single-molecule magnets (SMMs), [Mn 6 O(O 2 CMe) 6 (1,3-ppmd) 3 ](ClO 4 ) 2 , has been synthesized from the reaction of [Mn 3 O(O 2 CMe) 6 (py) 3 ](ClO 4 ) with 1,3-phenylene-bis(pyridin-2-ylmethanone) dioxime (1,3-ppmdH 2 ). It contains two [Mn III 3 O] +7 triangular units linked by three 1,3-ppmd 2 - groups into an [Mn 3 ] 2 dimer with D 3 symmetry. Solid-state dc and ac magnetic susceptibility measurements showed that each Mn 3 subunit retains its properties as an SMM with an S = 6 ground state. Magnetization vs. dc field sweeps on a single crystal reveal hysteresis loops below 1.3 K exhibiting exchange-biased quantum tunnelling of magnetization (QTM) steps with a bias field of +0.06 T. This is the first example of a dimer of SMMs showing a positive exchange bias of the QTM steps in the hysteresis loops, and it has therefore been subjected to a detailed analysis. Simulation of the loops determines that each Mn3 unit is exchange-coupled with its neighbour primarily through the 1,3-ppmd 2 - linkers, confirming a weak ferromagnetic inter-Mn 3 interaction of J 12 ≈ +6.5 mK ($\hat{H}= -2J\hat{S}_i·\hat{S}_j$ convention). High-frequency EPR studies of a microcrystalline powder sample enable accurate determination of the zero-field splitting parameters of the uncoupled Mn3 SMMs, while also confirming the weak exchange interaction between the two SMMs within each [Mn 3 ] 2 dimer. The combined results emphasize the ability of designed covalent linkers to generate inter-SMM coupling of a particular sign and relative magnitude, and thus the ability of such linkers to modulate the quantum physics. As such, this article supports the feasibility of using designed covalent linkers to develop molecular oligomers of SMMs, or other magnetic molecules, as multi-qubit systems and/or other components of new quantum technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rotational and reflectional equivariant convolutional neural network for data-limited applications: Multiphase flow demonstration

This article deals with approximating steady-state particle-resolved fluid flow around a fixed particle of interest under the influence of randomly distributed stationary particles in a dispersed multiphase setup using convolutional neural network (CNN). The considered problem involves rotational symmetry about the mean velocity (streamwise) direction. Thus, this work enforces this symmetry using SE(3)-equivariant, special Euclidean group of dimension 3, CNN architecture, which is translation and three-dimensional rotation equivariant. This study mainly explores the generalization capabilities and benefits of a SE(3)-equivariant network. Accurate synthetic flow fields for Reynolds number and particle volume fraction combinations spanning over a range of [86.22, 172.96] and [0.11, 0.45], respectively, are produced with careful application of symmetry-aware data-driven approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crystal structure and magnetic properties in semiconducting Eu 3-δ Zn x Sn y As 3 with Eu-Eu dimers

Magnetic structure and crystal symmetry, which primarily determine the time-reversal and inversion symmetry, may give rise to numerous exotic quantum phenomena in magnetic semiconductors and semimetals when arranged in different patterns. Here, a new layered magnetic semiconductor, Eu 3-δ Zn x Sn y As 3 , was discovered and high-quality single crystals were grown using the Sn flux. According to structural characterization by x-ray diffraction and atomic-resolution scanning transmission electron microscopy, Eu 3-δ Zn x Sn y As 3 is found to crystallize in a hexagonal symmetry with the space group P6 3 /mmc (No. 194). After examining different specimens, we conclude that their stoichiometry is fixed at ~Eu 2.6 Zn 0.65 Sn 0.85 As 3 , which meets the chemical charge balance. Eu 3-δ Zn x Sn y As 3 is composed of septuple (Eu 1-δ Sn y As 2 )-Eu-(Zn x As)-Eu sequences. The shortest Eu–Eu distance in the system is between two Eu layers separated by Zn x As along the c-axis. Magnetization measurement shows an antiferromagnetic ordering in Eu 3-δ Zn x Sn y As 3 at T N ~ 12 K, where the magnetic easy-axis is along the c-axis, and Mössbauer spectroscopy observes magnetic hyperfine splitting on Eu and Sn at 6 K. Magnetic anisotropy is significantly different from the ones along the ab-plane in other layered Eu-based magnetic semimetals. Heat capacity measurements confirm the magnetic transition around 12 K. Electrical resistivity measurement indicates semiconductor behavior with a band gap of ~0.86 eV. Finally, various Eu-based magnetic semiconductors could provide a tunable platform to study potential topological and magnetic properties.

36 MATERIALS SCIENCE↗

Mn-induced spin glass behavior in metallic Ir 3 Sn 7-x Mn x

Transition metal stannides are usually semiconductors with a narrow band gap. We report experimental investigation on metallic Ir 3 Sn 7– x Mn x ( x = 0 and 0.56). Single crystal x-ray diffraction refinement indicates that Ir 3 Sn 7– x Mn x crystals form a cubic structure (space group Im 3 - m ) with the lattice parameter a = 9.362(4) Å for x = 0 and 9.328(6) Å for x = 0.56. The electrical resistivity shows metallic behavior between 2 K and 300 K with T 2 dependence at T < 30 K for x = 0, reflecting the Fermi-liquid ground state. While Ir 3 Sn 7 exhibits weak diamagnetism, partial substitution of Sn by Mn results in spin glass behavior in Ir 3 Sn 7- x Mn x below T g ~ 13 K for x = 0.56. Remarkably, an upturn in the resistivity is observed in x = 0.56 below ~2 T g , suggesting strong spin fluctuation. This fluctuation is suppressed by the application of magnetic field, which is reflected in the observation of negative magnetoresistance. The unusual properties that emerge due to Mn doping are discussed.

Physics↗

Materials Data on Tl3PO4 by Materials Project

Tl3PO4 crystallizes in the hexagonal P6_3 space group. The structure is three-dimensional. Tl1+ is bonded in a 3-coordinate geometry to three O2- atoms. There are a spread of Tl–O bond distances ranging from 2.56–2.61 Å. P5+ is bonded in a tetrahedral geometry to four O2- atoms. There is three shorter (1.56 Å) and one longer (1.58 Å) P–O bond length. There are two inequivalent O2- sites. In the first O2- site, O2- is bonded in a distorted single-bond geometry to two equivalent Tl1+ and one P5+ atom. In the second O2- site, O2- is bonded in a distorted tetrahedral geometry to three equivalent Tl1+ and one P5+ atom.

36 MATERIALS SCIENCE↗

Materials Data on KPr5(CCl5)2 by Materials Project

KPr5(CCl5)2 crystallizes in the hexagonal P6_3 space group. The structure is three-dimensional. K1+ is bonded in a 3-coordinate geometry to nine Cl1- atoms. There are a spread of K–Cl bond distances ranging from 3.02–3.72 Å. There are three inequivalent Pr3+ sites. In the first Pr3+ site, Pr3+ is bonded in a 7-coordinate geometry to one C3- and six Cl1- atoms. The Pr–C bond length is 2.32 Å. There are three shorter (2.91 Å) and three longer (3.26 Å) Pr–Cl bond lengths. In the second Pr3+ site, Pr3+ is bonded in a 7-coordinate geometry to one C3- and six Cl1- atoms. The Pr–C bond length is 2.33 Å. There are three shorter (2.85 Å) and three longer (3.23 Å) Pr–Cl bond lengths. In the third Pr3+ site, Pr3+ is bonded in a 8-coordinate geometry to two C3- and six Cl1- atoms. There are one shorter (2.49 Å) and one longer (2.50 Å) Pr–C bond lengths. There are a spread of Pr–Cl bond distances ranging from 2.86–3.12 Å. There are two inequivalent C3- sites. In the first C3- site, C3- is bonded in a 5-coordinate geometry to four Pr3+ and one C3- atom. The C–C bond length is 1.44 Å. In the second C3- site, C3- is bonded in a 5-coordinate geometry to four Pr3+ and one C3- atom. There are four inequivalent Cl1- sites. In the first Cl1- site, Cl1- is bonded in a distorted trigonal non-coplanar geometry to three equivalent Pr3+ atoms. In the second Cl1- site, Cl1- is bonded to one K1+ and three Pr3+ atoms to form distorted corner-sharing ClKPr3 tetrahedra. In the third Cl1- site, Cl1- is bonded in a 4-coordinate geometry to one K1+ and three Pr3+ atoms. In the fourth Cl1- site, Cl1- is bonded in a 4-coordinate geometry to one K1+ and three equivalent Pr3+ atoms.

36 MATERIALS SCIENCE↗

Thermally reversible gels in electrophoresis. I - Matrix characterization

Two series of thermally reversible hydrogen-bonded gels have been characterized: (5 pct) PVA-(4 pct) PEG and (5 pct) PVA-(0.04 pct) borate gels. They both have extremely low melting points (16-17 C) and could be of potential interest for recovery of proteins after preparative electrophoresis. The PVA-borate gels can be exploited in the pH range 7-11 by progressively increasing the borate content in the pH interval 8 to 7 and concomitantly decreasing the borate levels in the pH zone 8 to 11. It is hypothesized that the low melting point of these gels is due to the fact that they are sparingly and sparsely hydrogen bonded along the PVA chain: on the average, 1 OH group out of 3 or 4 OH groups in the PVA polymer should be engaged in H-bond formation.

Righetti, Pier Giorgio↗

Computing the Relative Affinity of Chlorophylls a and b to Light-Harvesting Complex II

In plants and algae, the primary antenna protein bound to photosystem II is light-harvesting complex II (LHCII), a pigment–protein complex that binds eight chlorophyll (Chl) a molecules and six Chl b molecules. Chl a and Chl b differ only in that Chl a has a methyl group (–CH 3 ) on one of its pyrrole rings, while Chl b has a formyl group (–CHO) at that position. This blue-shifts the Chl b absorbance relative to Chl a . It is not known how the protein selectively binds the right Chl type at each site. Knowing the selection criteria would allow the design of light-harvesting complexes that bind different Chl types, modifying an organism to utilize the light of different wavelengths. The difference in the binding affinity of Chl a and Chl b in pea and spinach LHCII was calculated using multiconformation continuum electrostatics and free energy perturbation. Both methods have identified some Chl sites where the bound Chl type ( a or b ) has a significantly higher affinity, especially when the protein provides a hydrogen bond for the Chl b formyl group. However, the Chl a sites often have little calculated preference for one Chl type, so they are predicted to bind a mixture of Chl a and b . The electron density of the spinach LHCII was reanalyzed, which, however, confirmed that there is negligible Chl b in the Chl a -binding sites. Finally, it is suggested that the protein chooses the correct Chl type during folding, segregating the preferred Chl to the correct binding site.

chemical calculations↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight on Astronaut Health and Performance

INTRODUCTION Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis missions to the Moon and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices that provide both aerobic and resistive capabilities on one platform without including a treadmill. The European Enhanced Exploration Exercise Device [E4D] is one such apparatus. It is critical to validate the efficacy of using exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the effectiveness of using nominal ISS exercise devices for an entire mission compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS Crewmembers are assigned to one of three groups: 1) Controls (n ≥ 40), who partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), cycling on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS), and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who exercise on the CEVIS and ARED only (n = 8); and 3) Active Group 2, who perform aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both Active groups are not permitted to perform treadmill exercise for the entirety of their flight. Health and performance markers, including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and after spaceflight. RESULTS Fifteen subjects (4 Active [CEVIS + ARED], 11 Control) have been recruited. Data collection is ongoing. CONCLUSIONS This study will assess the efficacy of using exploration exercise modalities, including removing the treadmill exercise capability or exclusively using the E4D, compared to the nominal ISS exercise regimen across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions. Supported by the NASA Human Research Program and NASA Exploration Capabilities

A N Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

INTRODUCTION: Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. RESULTS: Thirteen subjects (3 Active [CEVIS + ARED], 10 Control) have been recruited for this study. Data collection is currently in progress. CONCLUSIONS: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

INTRODUCTION: Current exercise countermeasures on the International Space Station (ISS) include treadmill running, cycle ergometry, and resistive exercise, which are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. METHODS: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. RESULTS: Thirteen subjects (3 Active [CEVIS + ARED], 10 Control) have been recruited for this study. Data collection is currently in progress. CONCLUSIONS: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Muscle Volume Increases Following 16 Weeks of Resistive Exercise Training with the Advanced Resistive Exercise Device (ARED) and Free Weights

Space flight-induced muscle atrophy, particularly in the postural and locomotorymuscles, may impair task performance during long-duration space missions and planetary exploration. High intensity free weight (FW) resistive exercise training has been shown to prevent atrophy during bed rest, a space flight analog. NASA developed the Advanced Resistive Exercise Device (ARED) to simulate the characteristics of FW exercise (i.e. constant mass, inertial force) and to be used as a countermeasure during International Space Station (ISS) missions. PURPOSE: To compare the efficacy of ARED and FW training to induce hypertrophy in specific muscle groups in ambulatory subjects prior to deploying ARED on the ISS. METHODS: Twenty untrained subjects were assigned to either the ARED (8 males, 3 females) or FW (6 males, 3 females) group and participated in a periodizedtraining protocol consisting of squat (SQ), heel raise (HR), and deadlift(DL) exercises 3 d wk-1 for 16 wks. SQ, HR, and DL muscle strength (1RM) was measured before, after 8 wks, and after 16 wks of training to prescribe exercise and measure strength changes. Muscle volume of the vastigroup (V), hamstring group (H), hip adductor group (ADD), medial gastrocnemius(MG), lateral gastrocnemius(LG), and deep posterior muscles including soleus(DP) was measured using MRI pre-and post-training. Consecutive cross-sectional images (8 mm slices with a 2 mm gap) were analyzed and summed. Anatomical references insured that the same muscle sections were analyzed pre-and post-training. Two-way repeated measures ANOVAs (p<0.05) were used to test for differences in muscle strength and volume between training devices. RESULTS: SQ, HR, and DL 1RM increased in both FW (SQ: 49+/-6%, HR: 12+/-2%, DL: 23+/-4%) and ARED (SQ: 31+/-4%, HR: 18+/-2%, DL: 23+/-3%) groups. Both groups increased muscle volume in the V (FW: 13+/-2%, ARED: 10+/-2%), H (FW: 3+/-1%, ARED: 3+/-1 %), ADD (FW: 15=/-2%, ARED: 10+/-1%), LG (FW: 7+/-2%, ARED: 4+/-1%), MG (FW: 7+/-2%, ARED: 5+/-2%), and DP (FW: 2+/-1%; ARED: 2+/-1%) after training. There were no between group differences in muscle strength or volume. CONCLUSIONS: The increase in muscle volume and strength following ARED training is not different than FW training. With the training effects similar to FW and a 600 lb load capacity, ARED likely will protect against muscle atrophy in microgravity.

Nash, R. E.↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

Introduction: Current exercise countermeasures on the International Space Station (ISS), including treadmill running, cycle ergometry, and resistive exercise, are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices that provide both aerobic and resistive training on one platform without including a treadmill, such as the European Enhanced Exploration Exercise Device (E4D). It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. Methods: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40) who will partake in nominal exercise on the ISS, including running on the treadmill with vibration isolation system 2 (T2), ergometry on the cycle ergometer with vibration isolation and stabilization device (CEVIS), and strength training on the advanced resistive exercise device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), and blood and urine biochemical markers of bone metabolism will be assessed before, during, and following spaceflight. Results: Data collection for this study is currently in progress. Conclusions: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗

Effects of Replacing Treadmill Running with Alternative Exercise Countermeasures During Long-Duration Spaceflight

Introduction: Current exercise countermeasures on the International Space Station (ISS), including treadmill running, cycle ergometry, and resistive exercise, are used to protect crewmember health and performance during long-duration spaceflight. However, exploration vehicles for Artemis and beyond will have volume and power restrictions, requiring exercise hardware to have a smaller footprint and use fewer resources. Thus, recent efforts have focused on developing exercise devices (such as the European Enhanced Exploration Exercise Device [E4D]) that provide both aerobic and resistive training on one platform without including a treadmill. It is critical to validate the efficacy of exploration-focused exercise modalities to preserve muscle strength, aerobic fitness, bone density, and sensorimotor performance. Thus, the aim of this study is to determine the physiological effects of spaceflight that occur with nominal ISS exercise prescriptions compared to exploration-forward exercise modalities to determine if a treadmill is required to maintain current levels of protection during long-duration missions. Methods: Crewmembers will be assigned to one of three groups: 1) Control Group (n ≥ 40), who will partake in nominal exercise on the ISS, including running on the Treadmill with Vibration Isolation and Stabilization 2 (T2), ergometry on the Cycle Ergometer with Vibration Isolation and Stabilization (CEVIS) device, and strength training on the Advanced Resistive Exercise Device (ARED); 2) Active Group 1, who will partake in CEVIS and ARED exercise only (n = 8); and 3) Active Group 2, who will partake in aerobic and resistive exercise on the E4D only (n = 8). For Active Group 1, nominal aerobic exercise on T2 will be replaced with corresponding exercise on CEVIS. For Active Group 2, a dedicated exercise prescription will be designed to maximize the capabilities of the E4D to include resistive exercise, cycle ergometry, rowing, and rope pulling. Crewmembers in both active groups will not be permitted to perform treadmill exercise. Health and performance markers including bone mineral density (dual-energy x-ray absorptiometry [DXA]), body composition (DXA), cardiovascular fitness (cycle VO2peak), muscle strength and endurance (isometric/isokinetic testing, power endurance testing), sensorimotor performance (sit-to-stand, obstacle course), postural control (computerized dynamic posturography), Results: Eight subjects (2 Active [CEVIS + ARED], 6 Control) have been recruited for this study. Data collection is currently in progress. Conclusions: This study will assess the efficacy of exploration exercise modalities, including the effects of removing the treadmill exercise capability or of exclusively using the E4D, compared to nominal ISS exercise across an entire mission on bone, muscle, aerobic, and sensorimotor health and performance. Findings from this study will help provide a recommendation on whether these exploration exercise modalities can sufficiently protect against physiological deconditioning during spaceflight or whether a treadmill may be required to maintain current levels of protection during future exploration class spaceflight missions.

A.N. Varanoske↗