Search NASA⌕ Search

SEARCH · Search NASA

Results for “STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

CROCUS Low Cost All-in-One Weather Station AMB-004 Data Argonne National Laboratory Prairie Site

The Ambient Weather WS-2902D (AMB) is a low cost weather station that has become very useful for filling data gaps in harder to deploy locations. These low cost weather stations collect 13 second data, which is averaged to a five minute data output available to users through an Application Programming Interface (API) key. The data files contain measurements for precipitation, temperature, wind chill/heat index, relative humidity, dew point, UV index, solar radiation, wind speed, wind direction, wind gust, and with an external particulate matter 2.5 (PM 2.5) sensor. Having all of these measurements in one condense system allows for fast deploying and dense network capabilities. Three of the AMB weather stations were deployed at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20-acre prairie site at Argonne National Laboratory in Lemont, Illinois. The instruments are denoted by their three digit identifier (CMS-AMB-xxx) format. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (atmos), instrument name (CMS-AMB-004), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or ACT-DOE.

EARTH SCIENCE > ATMOSPHERE > AEROSOLS > PARTICULAT↗

Impact of Electric Vehicle Charging Station Reliability, Resilience, and Location on Electric Vehicle Adoption

While the majority of electric vehicle (EV) charging events in the United States occur at home, issues with public charging stations are consistently found to be a top reason that potential EV buyers do not purchase an EV, demonstrating that both EVSE reliability and availability impacts EV adoption. This report explores multiple parameters that impact EVSE reliability and deployment, which in turn impact EV sales. These include extreme weather, codes and standards, region (urban vs. rural), and grid network type. Grid reliability was not found to impact EV adoption. The relationships between EV station reliability, station resilience, grid resilience, and EV adoption are largely outside the scope of the National Renewable Energy Laboratory's (NREL's) Automotive Deployment Options Projection Tool (ADOPT) and other vehicle adoption models, so the methodology of this report is varied. Section 2 sets the baseline for infrastructure reliability, user satisfaction, and maintenance practices. Section 3 explores the ways that electric vehicle supply equipment (EVSE) reliability impacts the relationship between EVSE and EV adoption. Section 4 shows how geographical categories such as urban, rural, large grid, off-grid, or microgrid can be helpful in EVSE deployment strategies, as well as how the relationship between EVSE and EV adoption differs among these categories. Section 5 investigates the impacts of grid reliability and infrastructure resilience on EV adoption. Finally, Section 6 reverses the perspective to examine the impact that EVs and EVSE have on grid resilience and reliability. As recent funding initiatives result in an expansion of public chargers across the United States, as well as an increase in the uptime of existing chargers, EV adoption will likely grow.

33 ADVANCED PROPULSION SYSTEMS↗

Energy Improvements of Fire Station 71

Since 2018, the City of Shawnee, Kansas has completed two phases of the State of Kansas Facility Conservation Improvement Program (FCIP), an initiative that guarantees operational cost and energy savings through targeted construction improvements on City facilities and infrastructure. The City is currently in the third phase of this FCIP, where one of the projects included an investment in energy improvements for Fire Station 71 (FS 71). The City partnered with Navitas, an Energy Service Company (ESCO), to implement a Photovoltaic Solar Array on FS71. The purpose of this project was to invest in sustainable building improvements with Energy Conservation Measures (ECM) to bring cost savings to the City and to provide sustainable benefits to the residents of Shawnee. In the first task of the project, Navitas collaborated with the City of Shawnee and the Community Development Department to determine the optimal layout and schedule for the installation of the solar array on FS 71. In the second task of the project, Navitas installed the 99.8 kW DC Photovoltaic solar array system. This system installation comprised of racking, inverters, optimizers, load center, and disconnect, which were all installed at a total ECM price of $\$$247,948. The third task focused on start-up and commissioning of the array. Navitas installed a real-time data analytics information management system integrated with utility meters, which evaluates the operations of the utility system and verifies operation of equipment and ensures optimum operation for energy efficiency. In the final task of this project, this analytics system was used for monitoring and verification, which will continue to be used to evaluate the success of the project for the coming years. The primary goal of the project was to install the 99.8 kW DC PV solar array at FS 71 to demonstrate the viability of solar energy systems in essential municipal facilities. Fire stations are energy demanding structures, as they require a constant intake of power and have a high baseline energy usage. The success of solar arrays on a fire station exemplifies their energy efficiency and effectiveness and displays their potential for application on other city facilities. By installing a solar array at such a facility, the City sought not only to offset electricity usage but also to serve as a model for ECMs in other municipal facilities and infrastructure projects. From an economic standpoint, this project demonstrates the feasibility of renewable energy at the municipal level. The total project cost of $\$$247,948 was split evenly between city funds and award funding, minimizing financial risk while ensuring guaranteed long-term savings. Any excess savings that are beyond the guaranteed minimums remain with the city, which enables future investment in sustainable energy initiatives. This project provides many benefits to the public. In addition to reducing the environmental footprint of city operations, it lowers taxpayer-funded utility spending and improves the energy security of a critical facility. The knowledge gained from this implementation motivates the City to focus on similar efforts across other public facilities in future FCIP phases and other City projects.

14 SOLAR ENERGY↗

Analysis of Fast Charging Station Network for Electrified Ride-Hailing Services

Today's electric vehicle (EV) owners charge their vehicles mostly at home and seldom use public direct current fast charger (DCFCs), reducing the need for a large deployment of DCFCs for private EV owners. However, due to the emerging interest among transportation network companies to operate EVs in their fleet, there is great potential for DCFCs to be highly utilized and become economically feasible in the future. This paper describes a heuristic algorithm to emulate operation of EVs within a hypothetical transportation network company fleet using a large global positioning system data set from Columbus, Ohio. DCFC requirements supporting operation of EVs are estimated using the Electric Vehicle Infrastructure Projection tool. Operation and installation costs were estimated using real-world data to assess the economic feasibility of the recommended fast charging stations. Results suggest that the hypothetical transportation network company fleet increases daily vehicle miles traveled per EV with less overall down time, resulting in increased demand for DCFC. Sites with overhead service lines are recommended for hosting DCFC stations to minimize the need for trenching underground service lines. A negative relationship was found between cost per unit of energy and fast charging utilization, underscoring the importance of prioritizing utilization over installation costs when siting DCFC stations. Although this preliminary analysis of the impacts of new mobility paradigms on alternative fueling infrastructure requirements has produced several key results, the complexity of the problem warrants further investigation.

33 ADVANCED PROPULSION SYSTEMS↗

H2USA: Siting Refueling Stations in the Northeast

To achieve cost-effective deployment of both fuel cell electric vehicles (FCEVs) and hydrogen stations, the number of vehicles and public stations must grow together in areas of highest demand. This fact sheet introduces two advanced modeling tools and presents preliminary analysis of the hydrogen refueling station locations needed to support early consumer demand for FCEVs in the Northeast United States. United States.

33 ADVANCED PROPULSION SYSTEMS↗

Embedding Equity into Electric Vehicle Charging Station Design

Once a site location is selected for the installation of an electric vehicle (EV) charging station, the next step is to plan and design the specific station. Local and state governments can require and/ or incentivize accessible and safe design elements, so the station is constructed in an equitable manner.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Techno-Economic Assessments of Second-Life Batteries for Electric Vehicle Charging Stations

When electric vehicle (EV) batteries degrade below a certain capacity, they may no longer be suitable for automotive use but can be repurposed as second-life batteries (SLBs) for other applications, such as EV charging stations. When integrated with photovoltaic (PV) systems, SLB can store surplus solar energy, reducing reliance on the grid and lowering operational costs. This paper presents a novel techno-economic assessment framework for deploying SLBs in combination with PV in grid-connected EV charging stations. The proposed framework integrates the value proposition, charging station operation, optimal dispatch strategies, battery degradation modeling, input data requirements, and detailed procedures for generating key economic performance metrics. Insightful analyses are performed to assess the performance of SLBs in comparison to new batteries across various cost scenarios. The results indicate that SLBs become financially attractive when their cost is 40% or lower than new batteries.

energy storage↗

AmeriFlux US-DUF Denver Urban Field Station

This is the AmeriFlux version of the carbon flux data for the site US-DUF Denver Urban Field Station. Site Description - This site was established on a 25m freestanding former radio tower at the Forest Service's Rocky Mountain Research Station headquarters in Fort Collins, CO. The tower is situated next to a parking lot and several one and two story buildings. To the north and west is the campus of Colorado State University, and to the north and east is low density residential development. To the south and east are a busy intersection and rapid transit bus line, and to the south is green space surrounding the City of Fort Collins' Spring Creek Trail.

Frank, John [US Forest Service, Rocky Mountain Res↗

Precipitation and Air Pollution at Mountain and Plain Stations in Northern China: Insights Gained from Observations and Modeling

We analyzed 40 year data sets of daily average visibility (a proxy for surface aerosol concentration) and hourly precipitation at seven weather stations, including three stations located on the Taihang Mountains, during the summertime in northern China. There was no significant trend in summertime total precipitation at almost all stations. However, light rain decreased, whereas heavy rain increased as visibility decreased over the period studied. The decrease in light rain was seen in both orographic-forced shallow clouds and mesoscale stratiform clouds. The consistent trends in observed changes in visibility, precipitation, and orographic factor appear to be a testimony to the effects of aerosols. The potential impact of large-scale environmental factors, such as precipitable water, convective available potential energy, and vertical wind shear, on precipitation was investigated. No direct links were found. To validate our observational hypothesis about aerosol effects, Weather Research and Forecasting model simulations with spectral-bin microphysics at the cloud-resolving scale were conducted. Model results confirmed the role of aerosol indirect effects in reducing the light rain amount and frequency in the mountainous area for both orographic-forced shallow clouds and mesoscale stratiform clouds and in eliciting a different response in the neighboring plains. The opposite response of light rain to the increase in pollution when there is no terrain included in the model suggests that orography is likely a significant factor contributing to the opposite trends in light rain seen in mountainous and plain areas.

air pollution↗

Influence of lure choice and survey duration on scent stations for carnivore surveys

Abstract Noninvasive, camera‐based, scent station surveys have become a common approach to estimate population parameters for mammalian carnivores. Many carnivores are particularly sensitive to olfactory cues; and, as such, the quality and quantity of odor attractant used during surveys can significantly affect the accuracy and precision of the survey. Additionally, survey length is also an important consideration because many mammalian predators are highly mobile and elusive in nature. Using scent station surveys in autumn 2013 and 2014 on the Savannah River Site, Aiken, South Carolina, USA, we tested the effects of 5 lures: fatty acid, fish oil, synthetic fermented egg, beaver castor, and skunk essence on visitation rates, visitation probability, and latency to visitation of multiple predator species. We also estimated occupancy probability for 2 carnivore species using different survey lengths to determine the effect of survey period on the precision of occupancy estimates. We found that skunk essence had greater visitation probability and visits than other lures evaluated. Species‐specific bait‐preference models revealed that raccoons ( Procyon lotor ) were more likely to visit skunk essence, and coyotes ( Canis latrans ) were less likely to visit fish oil as compared with fatty acid. Latency to visitation ranged from 104.7 to 112.1 hours and did not vary among scents. Longer survey durations resulted in more precise estimates of occupancy and detection probability. Our results suggest a wide range of scents commonly used for carnivore capture may perform as well as, or better than, fatty acid for noninvasive carnivore surveys. Further, study designs should carefully consider the duration of scent‐station surveys depending on the level of precision desired in estimates of occupancy and detection probability. © 2019 The Wildlife Society.

Webster, Sarah C.↗

Methane Exhaust Measurements at Gathering Compressor Stations in the United States

Unburned methane entrained in exhaust from natural gas-fired compressor engines (“combustion slip”) can account for a substantial portion of station-level methane emissions. A novel in-stack, tracer gas method was coupled with Fourier transform infrared (FTIR) species measurements to quantify combustion slip from natural gas compressor engines at 67 gathering and boosting stations owned or managed by nine “study partner” operators in 11 U.S. states. The mean methane emission rate from 63 four-stroke, lean-burn (4SLB) compressor engines was 5.62 kg/h (95% CI = 5.15–6.17 kg/h) and ranged from 0.3 to 12.6 kg/h. The mean methane emission rate from 39 fourstroke, rich-burn (4SRB) compressor engines was 0.40 kg/h (95% CI = 0.37– 0.42 kg/h) and ranged from 0.01 to 4.5 kg/h. Study results for 4SLB engines were lower than both the U.S. EPA compilation of air pollutant emission factors (AP-42) and Inventory of U.S. Greenhouse Gas Emissions and Sinks (GHGI) by 8 and 9%, respectively. Study results for 4SRB engines were 43% of the AP-42 emission factor and 8% of the GHGI emission factor, the latter of which does not distinguish between engine types. Total annual combustion slip from the U.S. natural gas gathering and boosting sector was modeled using measured emission rates and compressor unit counts from the U.S. EPA Greenhouse Gas Reporting Program. Modeled results [328 Gg/y (95% CI = 235–436 Gg/y) of unburned methane] would account for 24% (95% CI = 17–31%) of the 1391 Gg of methane emissions for “Gathering and Boosting Stations”, or 6% of the net emissions for “Natural Gas Systems” (5598 Gg) as reported in the 2020 U.S. EPA GHGI. In conclusion, gathering and boosting combustion slip emissions reported in the 2020 GHGI (374 Gg) fall within the uncertainty of this model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Baltimore Community Weather Station Network: Filling the Urban Measurement Desert

Quantification and understanding of how heat, rainfall, and air quality vary within cities are needed to identify the area with the worst conditions, develop solutions to extreme weather, and assess the impact of proposed policies. However, neighborhood-level variability is not well quantified because there are few environmental measurement stations within cities. In Baltimore City, a community-based network of weather stations to address this issue has been developed through a partnership between universities, state agencies, and Baltimore residents. The weather stations are hosted by community partners, and the data collected are enabling the mapping of urban weather across the city and the testing of models and proposed mitigation strategies. In addition, the network provides direct community involvement, with resulting benefits of increased community engagement, education, and empowerment. Researchers have an opportunity to democratize the scientific process and ensure that local knowledge and lived experiences of city residents inform future decision-making. The approach could be used as a model for other cities that apply similar monitoring instruments for other environmental exposures.

community↗

Conceptual Design of the Moderator Test Station at the Spallation Neutron Source

We describe the Moderator Test Station (MTS), under construction at the Spallation Neutron Source. We will leverage the Beam Test Facility (BTF) at the Spallation Neutron Source to provide a moderator neutronics test stand with which we will verify the anticipated performance gains expected and required from the innovative moderator concepts central to the SNS Second Target Station (STS) and the future of the First Target Station (FTS). These concepts include large-volume para-hydrogen moderators and high-brightness tube moderators. The MTS will add to the existing BTF a proton beam chopper similar to that already used in the SNS at the RFQ exit (the so-called MEBT chopper), various proton beam transport components, a neutron-producing target, a cryogenic moderator test stand, a reflector-shielding assembly, and a performance assessment neutron beamline. The MTS will provide the ability to test a wide variety of moderators in a prototypic configuration, simultaneously measuring the neutronic performance of the moderator concept central to the anticipated STS gains and developing the instrumentation necessary to provide that performance in a production environment. The presentation will describe the MTS, its progress, and the way we optimize the prototypic nature of the moderators we will test.

Iverson, Erik B↗

The shallow water equations as a hybrid flow model for the numerical and experimental analysis of hydro power stations

The numerical analysis of hydro power stations is an important method of the hydraulic design and is used for the development and optimisation of hydro power stations in addition to the experiments with the physical submodel of a full model in the hydraulic laboratory. For the numerical analysis, 2D and 3D models are appropriate and commonly used.The 2D models refer mainly to the shallow water equations (SWE), since for this flow model a large experience on a wide field of applications for the flow analysis of numerous problems in hydraulic engineering already exists. Often, the flow model is verified by in situ measurements. In order to consider 3D flow phenomena close to singularities like weirs, hydro power stations etc. the development of a hybrid fluid model is advantageous to improve the quality and significance of the global model. Here, an extended hybrid flow model based on the principle of the SWE is presented. The hybrid flow model directly links the numerical model with the experimental data, which may originate from physical full models, physical submodels and in-situ measurements. Hence a wide field of application of the hybrid model emerges including the improvement of numerical models and the strong coupling of numerical and experimental analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coincident learning for beam-based rf station fault identification using phase information at the SLAC linac coherent light source

Anomalies in radio-frequency (rf) stations can result in unplanned downtime and performance degradation in linear accelerators such as SLAC’s Linac Coherent Light Source (LCLS). Detecting these anomalies is challenging due to the complexity of accelerator systems, high data volume, and scarcity of labeled fault data. Prior work identified faults using beam-based detection, combining rf amplitude and beam position monitor data. Due to the simplicity of the rf amplitude data, classical methods are sufficient to identify faults, but the recall is constrained by the low-frequency and asynchronous characteristics of the data. In this work, we leverage high-frequency, time-synchronous rf phase data to enhance anomaly detection in the LCLS accelerator. Due to the complexity of phase data, classical methods fail, and we instead train deep neural networks within the Coincident Anomaly Detection (CoAD) framework. We find that applying CoAD to phase data detects nearly 3 times as many anomalies as when applied to amplitude data, while achieving broader coverage across rf stations. Furthermore, the rich structure of phase data enables us to cluster anomalies into distinct physical categories. Through the integration of auxiliary system status bits, we link clusters to specific fault signatures, providing additional granularity for uncovering the root cause of faults. We also investigate interpretability via Shapley values, confirming that the learned models focus on the most informative regions of the data and providing insight for cases where the model makes mistakes. This work demonstrates that phase-based anomaly detection for rf stations improves both diagnostic coverage and root cause analysis in accelerator systems and that deep neural networks are essential for effective analysis.

Accelerator Physics (physics.acc-ph)↗