Search NASA⌕ Search

SEARCH · Search NASA

Results for “STORAGE TANK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Solar Space and Water Heating for Hospital --Charlottesville, Virginia

Solar heating system described in an 86-page report consists of 88 single-glazed selectively-coated baseplate collector modules, hot-water coils in air ducts, domestic-hot-water preheat tank, 3,000 Gallon (11,350-1) concrete urethane-insulated storage tank and other components.

Source record↗

Computational modeling of the pressurization process in a NASP vehicle propellant tank experimental simulation

A multidimensional computational model of the pressurization process in a slush hydrogen propellant storage tank was developed and its accuracy evaluated by comparison to experimental data measured for a 5 ft diameter spherical tank. The fluid mechanic, thermodynamic, and heat transfer processes within the ullage are represented by a finite-volume model. The model was shown to be in reasonable agreement with the experiment data. A parameter study was undertaken to examine the dependence of the pressurization process on initial ullage temperature distribution and pressurant mass flow rate. It is shown that for a given heat flux rate at the ullage boundary, the pressurization process is nearly independent of initial temperature distribution. Significant differences were identified between the ullage temperature and velocity fields predicted for pressurization of slush and those predicted for pressurization of liquid hydrogen. A simplified model of the pressurization process was constructed in search of a dimensionless characterization of the pressurization process. It is shown that the relationship derived from this simplified model collapses all of the pressure history data generated during this study into a single curve.

Sasmal, G. P.↗

Comparing the results of an analytical model of the no-vent fill process with no-vent fill test results for a 4.96 cu m (175 cu ft) tank

NASA-Lewis has been investigating a no-vent fill method for refilling cryogenic storage tanks in low gravity. Analytical modeling based on analyzing the heat transfer of a droplet has successfully represented the process in 0.034 and 0.142 sq m commercial dewars using liquid nitrogen and hydrogen. Recently a large tank (4.96 sq m) was tested with hydrogen. This lightweight tank is representative of spacecraft construction. This paper presents efforts to model the large tank test data. The droplet heat transfer model is found to overpredict the tank pressure level when compared to the large tank data. A new model based on equilibrium thermodynamics has been formulated. This new model is compared to the published large scale tank's test results as well as some additional test runs with the same equipment. The results are shown to match the test results within the measurement uncertainty of the test data except for the initial transient wall cooldown where it is conservative (i.e., overpredicts the initial pressure spike found in this time frame).

Taylor, William J.↗

Development of a Robust Reference Electrode in Aggressive Chemical and Radiation Environments in the Hanford Waste Tanks

The Hanford site stores more than 200 million liters of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground carbon-steel storage tanks, separated between 149 single shell tanks (SSTs) and 28 double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The tanks will need to remain in-service far beyond the initial 40-year design life, and effective corrosion control practices must remain in force to extend the tanks’ lifespans. This effort includes direct measurements of corrosion rate (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements and open circuit potential measurements). The Hanford site began monitoring the corrosion potential in select DSTs in 2008. Of the 45 reference electrodes that have been installed, 29 have failed and 6 others provided unreliable results. DOE-EM is supporting a 3-year program to develop a chemical and radiation resistant reference electrode for application in the Hanford tanks. The first year of the program focused on understanding the failure mechanism for the reference electrodes and identification of candidate construction materials that would mitigate degradation of the electrodes in the waste environment. During the second year of the program, the objectives were to: 1) test candidate materials under simulated waste conditions, 2) design components that will extend the service life of the electrode, 3) fabricate materials for prototype reference electrodes, and 4) assemble prototype reference electrodes for accelerated testing. The reference electrode is constructed of four principal parts: 1) junction, 2) casing, 3) inner chamber backfill materials, and 4) the sensing wire. Principally, improvements of the junction, casing, and inner chamber backfill materials are being pursued. The junction material at the interface between the waste and the inner chamber of the reference electrode was identified as a critical component in the failure of the reference electrodes. Nine candidate replacement junction materials were tested under simulated waste conditions to evaluate permeation rate. These materials included a variety of polymeric and ceramic materials, some of which were 3-D printed. Thus far, porous polyvinylidene fluoride materials have performed satisfactorily and are being considered for prototype development. The commercial electrode casing materials in general have performed well. Additionally, 3-D printing of chemically and mechanically stable materials is being investigated as a means for further improvement in fabrication consistency. SRNL has also investigated altering the reference electrode design to extend the service life. The new design of the interior of the reference electrode casing creates a longer, more tortuous path between the junction material and the electrode sensing wire. A finite element model was used to optimize the design without adversely impacting the circuit resistance of the electrode during the measurements, thus preserving the measurement accuracy while enhancing the service life. The inner chamber back fill materials are also critical to the performance of the reference electrode. Materials that are resistant to intruding tank waste and provide a conductive path to the sensing wire were investigated. Gel and powder materials that are interspersed with a conductive chloride bearing material were tested for their influence on diffusion and electrode resistance. All the investigated materials and components will be assembled, with collaboration from commercial vendors, to fabricate the initial prototypes. Accelerated testing of the prototypes will be initiated in Year 2 of the program and will be completed in Year 3. A recommendation on the materials of construction and the design of the new robust reference electrode will be presented to the Hanford tank farm facility.

Sykes, Kiana [Savannah River National Laboratory (↗

Mars Propellant Liquefaction and Storage Performance Modeling using Thermal Desktop with an Integrated Cryocooler Model

NASAs current Mars architectures are assuming the production and storage of 23 tons of liquid oxygen on the surface of Mars over a duration of 500+ days. In order to do this in a mass efficient manner, an energy efficient refrigeration system will be required. Based on previous analysis NASA has decided to do all liquefaction in the propulsion vehicle storage tanks. In order to allow for transient Martian environmental effects, a propellant liquefaction and storage system for a Mars Ascent Vehicle (MAV) was modeled using Thermal Desktop. The model consisted of a propellant tank containing a broad area cooling loop heat exchanger integrated with a reverse turbo Brayton cryocooler. Cryocooler sizing and performance modeling was conducted using MAV diurnal heat loads and radiator rejection temperatures predicted from a previous thermal model of the MAV. A system was also sized and modeled using an alternative heat rejection system that relies on a forced convection heat exchanger. Cryocooler mass, input power, and heat rejection for both systems were estimated and compared against sizing based on non-transient sizing estimates.

fluid modeling↗

Mars Propellant Liquefaction Modeling in Thermal Desktop

NASAs current Mars architectures are assuming the production and storage of 23 tons of liquid oxygen on the surface of Mars over a duration of 500+ days. In order to do this in a mass efficient manner, an energy efficient refrigeration system will be required. Based on previous analysis NASA has decided to do all liquefaction in the propulsion vehicle storage tanks. In order to allow for transient Martian environmental effects, a propellant liquefaction and storage system for a Mars Ascent Vehicle (MAV) was modeled using Thermal Desktop. The model consisted of a propellant tank containing a broad area cooling loop heat exchanger integrated with a reverse turbo Brayton cryocooler. Cryocooler sizing and performance modeling was conducted using MAV diurnal heat loads and radiator rejection temperatures predicted from a previous thermal model of the MAV. A system was also sized and modeled using an alternative heat rejection system that relies on a forced convection heat exchanger. Cryocooler mass, input power, and heat rejection for both systems were estimated and compared against sizing based on non-transient sizing estimates.

Cryogenics↗

Computer programs for pressurization (RAMP) and pressurized expulsion from a cryogenic liquid propellant tank

An analysis to predict the pressurant gas requirements for the discharge of cryogenic liquid propellants from storage tanks is presented, along with an algorithm and two computer programs. One program deals with the pressurization (ramp) phase of bringing the propellant tank up to its operating pressure. The method of analysis involves a numerical solution of the temperature and velocity functions for the tank ullage at a discrete set of points in time and space. The input requirements of the program are the initial ullage conditions, the initial temperature and pressure of the pressurant gas, and the time for the expulsion or the ramp. Computations are performed which determine the heat transfer between the ullage gas and the tank wall. Heat transfer to the liquid interface and to the hardware components may be included in the analysis. The program output includes predictions of mass of pressurant required, total energy transfer, and wall and ullage temperatures. The analysis, the algorithm, a complete description of input and output, and the FORTRAN 4 program listings are presented. Sample cases are included to illustrate use of the programs.

Masters, P. A.↗

Pressurization and expulsion of a flightweight liquid hydrogen tank

Experimental results are presented for pressurization and expulsion of a flightweight 4.89 cu m liquid hydrogen storage tank under normal gravity conditions. Pressurization and expulsion times were parametrically varied to study the effects of longer transfer times expected in future space flight applications. It was found that the increase in pressurant consumption with increased operational time is significant at shorter pressurization or expulsion durations and diminishes as the duration lengthens. Gas-to-wall heat transfer in the ullage was the dominant mode of energy exchange, with more than 50 percent of the pressurant energy being lost to tank wall heating in expulsions and the long duration pressurizations. Advanced data analysis will require a multidimensional approach combined with improved measurement capabilities of liquid-vapor interfacial transport phenomena.

Van Dresar, N. T.↗

SIMS prototype system 1 test results: Engineering analysis

The space and domestic water solar heating system designated SIMS Prototype Systems 1 was evaluated. The test system used 720 ft (gross) of Solar Energy Products Air Collectors, a Solar Control Corporation SAM 20 Air Handler with Model 75-175 control unit, a Jackson Solar Storage tank with Rho Sigma Mod 106 controller, and 20 tons of rack storage. The test data analysis performed evaluates the system performance and documents the suitability of SIMS Prototype System 1 hardware for field installation.

Source record↗

Vented Chill / No-Vent Fill of Cryogenic Propellant Tanks

Architectures for extended duration missions often include an on-orbit replenishment of the space vehicle's cryogenic liquid propellants. Such a replenishment could be accomplished via a tank-to-tank transfer from a dedicated tanker or a more permanent propellant depot storage tank. Minimizing the propellant loss associated with transfer line and receiver propellant tank thermal conditioning is essential for mass savings. A new methodology for conducting tank-to-tank transfer while minimizing such losses has been demonstrated. Charge-Hold-Vent is the traditional methodology for conducting a tank-to-tank propellant transfer. A small amount of cryogenic liquid is introduced to chill the transfer line and propellant tank. As the propellant absorbs heat and undergoes a phase change, the tank internal pressure increases. The tank is then vented to relieve pressure prior to another charge of cryogenic liquid being introduced. This cycle is repeated until the transfer lines and tank are sufficiently chilled and the replenishment of the propellant tank is complete. This method suffers inefficiencies due to multiple chill and vent cycles within the transfer lines and associated feed system components. Additionally, this system requires precise measuring of cryogenic fluid delivery for each transfer, multiple valve cycling events, and other complexities associated with cycled operations. To minimize propellant loss and greatly simplify on-orbit operations, an alternate methodology has been designed and demonstrated. The Vented Chill / No Vent Fill method is a simpler, constant flow approach in which the propellant tank and transfer lines are only chilled once. The receiver tank is continuously vented as cryogenic liquid chills the transfer lines, tank mass and ullage space. Once chilled sufficiently, the receiver tank valve is closed and the tank is completely filled. Interestingly, the vent valve can be closed prior to receiver tank components reaching liquid saturation temperature. An incomplete fill results if insufficient energy is removed from the tank's thermal mass and ullage space. The key to successfully conducting the no vent fill is to assure that sufficient energy is removed from the system prior to closing the receiver tank vent valve. This paper will provide a description of the transfer methodology and test article, and will provide a discussion of test results.

Rhys, Noah O.↗

Glass bead shot peening retards stress corrosion failure of titanium tanks

Rigidly controlled shot peening retards the incompatibility between titanium alloys and nitrogen tetroxide in rocket-propellant storage tanks. This sets up a residual compressive stress in the surface of a material which reduces tensile stresses in the material fibers, alleviating stress corrosion.

Bales, T. T.↗

Cryogenic Fluid Management Technology for Moon and Mars Missions

In support of the U.S. Space Exploration Policy, focused cryogenic fluid management technology efforts are underway within the National Aeronautics and Space Administration. Under the auspices of the Exploration Technology Development Program, cryogenic fluid management technology efforts are being conducted by the Cryogenic Fluid Management Project. Cryogenic Fluid Management Project objectives are to develop storage, transfer, and handling technologies for cryogens to support high performance demands of lunar, and ultimately, Mars missions in the application areas of propulsion, surface systems, and Earth-based ground operations. The targeted use of cryogens and cryogenic technologies for these application areas is anticipated to significantly reduce propellant launch mass and required on-orbit margins, to reduce and even eliminate storage tank boil-off losses for long term missions, to economize ground pad storage and transfer operations, and to expand operational and architectural operations at destination. This paper organizes Cryogenic Fluid Management Project technology efforts according to Exploration Architecture target areas, and discusses the scope of trade studies, analytical modeling, and test efforts presently underway, as well as future plans, to address those target areas. The target areas are: liquid methane/liquid oxygen for propelling the Altair Lander Ascent Stage, liquid hydrogen/liquid oxygen for propelling the Altair Lander Descent Stage and Ares V Earth Departure Stage, liquefaction, zero boil-off, and propellant scavenging for Lunar Surface Systems, cold helium and zero boil-off technologies for Earth-Based Ground Operations, and architecture definition studies for long term storage and on-orbit transfer and pressurization of LH2, cryogenic Mars landing and ascent vehicles, and cryogenic production via in situ resource utilization on Mars.

Doherty, Michael P.↗

Design and Materials of Reference Electrodes for Radioactive Waste Tank Service – A Literature Review

The Hanford site stores approximately 55 million gallons of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground, carbon steel storage tanks, 149 of these are single shell tanks (SSTs) and 28 of these are double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The DSTs have been in service for 38 to 56 years and current plans indicate that WTP operations will be completed in 2075. Thus, the tanks will need to remain in service far beyond the initial 40-year life expectancy. For life extension of the tanks, effective corrosion control practices must remain in force. This effort includes direct measurements of the extent of corrosion (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparing the results of an analytical model of the no-vent fill process with no-vent fill test results for a 4.96 cubic meters (175 cubic feet) tank

The NASA Lewis Research Center (NASA/LeRC) have been investigating a no-vent fill method for refilling cryogenic storage tanks in low gravity. Analytical modeling based on analyzing the heat transfer of a droplet has successfully represented the process in 0.034 m and 0.142 cubic m commercial dewars using liquid nitrogen and hydrogen. Recently a large tank (4.96 cubic m) was tested with hydrogen. This lightweight tank is representative of spacecraft construction. This paper presents efforts to model the large tank test data. The droplet heat transfer model is found to over predict the tank pressure level when compared to the large tank data. A new model based on equilibrium thermodynamics has been formulated. This new model is compared to the published large scale tank's test results as well as some additional test runs with the same equipment. The results are shown to match the test results within the measurement uncertainty of the test data except for the initial transient wall cooldown where it is conservative (i.e., overpredicts the initial pressure spike found in this time frame).

Taylor, William J.↗

Pressurization and expulsion of a flightweight liquid hydrogen tank

Experimental results are presented for pressurization and expulsion of a flight-weight 4.89 cu m liquid hydrogen storage tank under normal gravity conditions. Pressurization and expulsion times are parametrically varied to study the effects of longer transfer times expected in future space flight applications. It is found that the increase in pressurant consumption with increased operational time is significant at shorter pressurization or expulsion durations and diminishes as the duration lengthens. Gas-to-wall heat transfer in the ullage is the dominant mode of energy exchange, with more than 50 percent of the pressurant energy being lost to tank wall heating in expulsions and the long duration pressurizations. Advanced data analysis will require a multidimensional approach combined with improved measurement capabilities of liquid-vapor interfacial transport phenomena.

Vandresar, N. T.↗

Think Tanks

A new inspection robot from Solex Robotics Systems was designed to eliminate hazardous inspections of petroleum and chemical storage tanks. The submersible robot, named Maverick, is used to inspect the bottoms of tanks, keeping the tanks operational during inspection. Maverick is able to provide services that will make manual tank inspections obsolete. While the inspection is conducted, Maverick's remote human operators remain safe outside of the tank. The risk to human health and life is now virtually eliminated. The risk to the environment is also minimal because there is a reduced chance of spillage from emptying and cleaning the tanks, where previously, tons of pollutants were released through the process of draining and refilling.

Source record↗