Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Rapid Nucleic Acid Isolation Method and Fluid Handling Devices Overview

Sample preparation is a common bottleneck in genetic analysis. Tools that reduce time and effort are of value in a laboratory setting. There is a need for a genetic analysis/detection system that is not only mobile, ruggedized, easy-to-use but also provides an enclosed fluid handling that diminishes the risks of Ribonucleic acid (RNA) contamination and degradation during processing. NASA has developed a novel assay methodology and suite of devices to isolate nucleic acids and prepare samples for real-time (quantitative) polymerase chain reaction (PCR) analysis that solves the problem of contamination and degradation because of the advanced microfluidics which provides better fluid handling. The assay employs an aqueous-based non-alcohol method that yields robust RNA quality. The suite of ready-to-use devices provide pre-loaded reagents in liquid and lyophilized formats to enable rapid, cost effective, and portable manual operation in the laboratory or remote field environments.

Travis Boone↗

Rotary Percussive Sample Acquisition Tool (SAT): Hardware Development and Testing

In support of a potential Mars Sample Return (MSR) mission an Integrated Mars Sample Acquisition and Handling (IMSAH) architecture has been proposed to provide a means for Rover-based end-to-end sample capture and caching. A key enabling feature of the architecture is the use of a low mass sample Acquisition Tool (SAT) that is capable of drilling and capturing rock cores directly within a sample tube in order to maintain sample integrity and prevent contamination across the sample chain. As such, this paper will describe the development and testing of a low mass rotary percussive SAT that has been shown to provide a means for core generation, fracture, and capture.

Integrated Mars Sample Acquisition and Handling (I↗

Design of a robot-automated flat plate/reflection geometry x-ray diffraction setup for accelerated materials discovery and structural screening

Here, we report the design, construction, and automation of a flat plate sample loading, alignment, and data acquisition system for X-ray diffraction measurements in reflection geometry implemented at the Stanford Synchrotron Radiation Lightsource. The system is built onto a single platform, enabling facile transferability, and is compartmentalized into sample storage, sample transfer, and sample position/alignment segments. The core feature of this system is a six-axis robotic arm that offers a large range of highly reproducible and programable movements. The degrees of freedom of the robot arm enable adaptability in which movements can be modified to fit various beamline environments and sample configurations. Samples are housed on 3D printed sample mounts, which are arranged onto a 6 × 2 array of sample cassettes capable of holding 7 samples. Using sample mounts designed for solid oxide electrolysis button cells (SOECs), the maximum tray capacity is 84 samples, which can be aligned and run in ~ 24 hours with long exposure scans. The sample array is additionally capable of accommodating a range of sample sizes and geometries due to the rapid 3D printed fabrication. The components of the setup will be described in detail and performance will be demonstrated with a set of representative SOEC and XRD standard samples. Opportunities for future developments and integration with the automated setup are summarized.

08 HYDROGEN↗

Orbiting Quarantine Facility. The Antaeus report, summary

Requirements for handling extraterrestrial samples in an orbiting quarantine facility are examined. The major concepts and findings of the study are outlined. One approach that could be taken for receiving, containing, and analyzing samples returned from the surface of Mars in a mission analogous to the lunar return missions of the late 1960s and early 1970s is described. It constructs a general mission scenario and presents an overall systems design, including an approach to cost assessment. Particular attention is paid to the design of system hardware components and to the elaboration of an experimental protocol.

Source record↗

Rheological characterization of addition polyimide matrix resins and prepregs

Although graphite-reinforced polyimide matrix composites offer outstanding specific strength and stiffness, together with high thermal oxidative stability, processing problems connected with their rheological behavior remain to be addressed. The present rheological studies on neat polyimide resin systems encountered outgassing during cure. A staging technique has been developed which can successfully handle polyimide samples, and novel methods were applied to generate rheological curves for graphite-reinforced prepregs. The commercial graphite/polyimide systems studied were PRM 15, LARC 160, and V378A.

Maximovich, M. G.↗

Microgravity Science in Space Flight Gloveboxes

Microgravity science studies the influences of gravity on phenomena in fluids, materials processes, combustion, and human cell growth in the low acceleration environment of space flight. During the last decade, the accomplishment of the flight research in the field has evolved into an effective cooperation between the flight crew in the Shuttle and the ground-based investigator using real-time communication via voice and video links. This team structure has led to interactive operations in which the crew performs the experimentation while guided, as necessary, by the science investigator who formulated the investigation and who will subsequently interpret and analyze the data. One of the primary challenges to implementing this interactive research has been the necessity of structuring a means of handling fluids, gases, and hazardous materials in a manned laboratory that exhibits the novelty of weightlessness. Developing clever means of designing experiments in closed vessels is part of the solution- but the space flight requirement for one and two failure-tolerant containment systems leads to serious complications in the physical handling of sample materials. In response to the conflict between the clear advantage of human operation and judgment, versus the necessity to isolate the experiment from the crewmember and the spacecraft environment, the Microgravity Research Program has initiated a series of Gloveboxes in the various manned experiment carriers. These units provide a sealed containment vessel whose interior is under a negative pressure with respect to the ambient environment but is accessible to a crewmember through the glove ports.

Baugher, Charles↗

Single track effects, Biostack and risk assessment

The scientific career of Prof. Bucker has spanned a very exciting period in the fledgling science of Space Radiation Biology. The capability for placing biological objects in space was developed, and the methods for properly packaging, retrieving and analyzing them were worked out. Meaningful results on the effects of radiation were obtained for the first time. In fact, many of the successful techniques and methodologies for handling biological samples were developed in Prof. Bucker's laboratories, as attested by the extensive Biostack program. He was the first to suggest and successfully carry out experiments in space directly aimed at measuring effects of single tracks of high-energy heavy galactic cosmic rays by specifically identifying whether or not the object had been hit by a heavy particle track. Because the "hit" frequencies of heavy galactic cosmic rays to cell nuclei in the bodies of space travelers will be low, it is expected that any effects to humans on the cellular level will be dominated by single-track cell traversals. This includes the most important generally recognized late effect of space radiation exposure: radiation-induced cancer. This paper addresses the single-track nature of the space radiation environment, and points out the importance of single "hits" in the evaluation of radiation risk for long-term missions occurring outside the earth's magnetic field. A short review is made of biological objects found to show increased effects when "hit" by a single heavy charged-particle in space. A brief discussion is given of the most provocative results from the bacterial spore Bacillus subtilis: experimental evidence that tracks can affect biological systems at much larger distances from the trajectory than previously suspected, and that the resultant inactivation cross section in space calculated for this system is very large. When taken at face value, the implication of these results, when compared to those from experiments performed at ground-based accelerators with beams at low energies in the same LET range, is that high-energy particles can exert their influence a surprising distance from their trajectory and the inactivation cross sections are some 20 times larger than expected. Clearly, beams from high-energy heavy-ion accelerators should be used to confirm these results. For those end points that can also be caused by low-LET beams such as high-energy protons, it is important to measure their action cross sections as well. The ratio of the cross sections for a high-LET beam to that of a low-LET beam is an interesting experimental ratio and, we suggest, of more intrinsic interest than the RBE (Relative Biological Effectiveness). It is a measure of the "biological" importance of one particle type relative to another particle type. This ratio will be introduced and given the name RPPE (Relative Per Particle Effectiveness). Values of RPPE have appeared in the literature and will be discussed. A rather well-known value of this quantity (13,520) has been suggested for the RPPE of high-energy iron ions to high-energy protons. This value was suggested by Letaw et al. Nature 330, 709-710 (1987)] we will call it the Letaw limit. It will be discussed in terms of the importance of the heavy-ion component vs light-ion component of the galactic cosmic rays. It is also pointed out, however, that there may be unique effects from single tracks of heavy ions that do not occur from light-ion tracks. For such effects, the concepts of both RBE and RPPE lose their meaning.

NASA Discipline Radiation Health↗

Finding Interstellar Particle Impacts on Stardust Aluminium Foils: The Safe Handling, Imaging, and Analysis of Samples Containing Femtogram Residues

Impact ionisation detectors on a suite of spacecraft have shown the direction, velocity, flux and mass distribution of smaller ISP entering the Solar System. During the aphelion segments of the Stardust flight, a dedicated collector surface was oriented to intercept ISP of beta = 1, and returned to Earth in January 2006. In this paper we describe the probable appeareance and size of IS particle craters from initial results of experimental impacts and numerical simulation, explain how foils are being prepared and mounted for crater searching by automated acquisition of high magnification electron images (whilst avoiding contamination of the foils) and comment on appropriate analytical techniques for Preliminary Examination (PE).

Kearsley, A. T.↗

Time-Domain Terahertz Computed Axial Tomography NDE System

NASA has identified the need for advanced non-destructive evaluation (NDE) methods to characterize aging and durability in aircraft materials to improve the safety of the nation's airline fleet. 3D THz tomography can play a major role in detection and characterization of flaws and degradation in aircraft materials, including Kevlar-based composites and Kevlar and Zylon fabric covers for soft-shell fan containment where aging and durability issues are critical. A prototype computed tomography (CT) time-domain (TD) THz imaging system has been used to generate 3D images of several test objects including a TUFI tile (a thermal protection system tile used on the Space Shuttle and possibly the Orion or similar capsules). This TUFI tile had simulated impact damage that was located and the depth of damage determined. The CT motion control gan try was designed and constructed, and then integrated with a T-Ray 4000 control unit and motion controller to create a complete CT TD-THz imaging system prototype. A data collection software script was developed that takes multiple z-axis slices in sequence and saves the data for batch processing. The data collection software was integrated with the ability to batch process the slice data with the CT TD-THz image reconstruction software. The time required to take a single CT slice was decreased from six minutes to approximately one minute by replacing the 320 ps, 100-Hz waveform acquisition system with an 80 ps, 1,000-Hz waveform acquisition system. The TD-THZ computed tomography system was built from pre-existing commercial off-the-shelf subsystems. A CT motion control gantry was constructed from COTS components that can handle larger samples. The motion control gantry allows inspection of sample sizes of up to approximately one cubic foot (.0.03 cubic meters). The system reduced to practice a CT-TDTHz system incorporating a COTS 80- ps/l-kHz waveform scanner. The incorporation of this scanner in the system allows acquisition of 3D slice data with better signal-to-noise using a COTS scanner rather than the gchirped h scanner. The system also reduced to practice a prototype for commercial CT systems for insulating materials where safety concerns cannot accommodate x-ray. A software script was written to automate the COTS software to collect and process TD-THz CT data.

Zimdars, David↗

Sample Sealing Approaches for Mars Sample Return Caching

Objective ot this project was to investigate sealing methods for encapsulating samples in 1 cm diameter thin-walled sample tubes applicable to future proposed Mars Sample Return Techniques implemented include a spring energized Teflon sleeve plug, a crimped tube seal, a heat-activated shape memory alloy plug, a shape memory alloy activated cap, a solder-based plug, and a solder-based cap

Mars Sample Return (MSR) mission↗

Transport Powder and Liquid Samples by Surface Acoustic Waves

Sample transport is an important requirement for In-situ analysis of samples in NASA planetary exploration missions. Tests have shown that powders or liquid drops on a surface can be transported by surface acoustic waves (SAW) that are generated on the surface using interdigital transducers. The phenomena were investigated experimentally and to generate SAWs interdigital electrodes were deposited on wafers of 128 deg rotated Y-cut LiNbO?. Transporting capability of the SAW device was tested using particles of various sizes and drops of various viscosities liquids. Because of different interaction mechanisms with the SAWs, the powders and the liquid drops were observed to move in opposite directions. In the preliminary tests, a speed of 180 mm/s was achieved for powder transportation. The detailed experimental setup and results are presented in this paper. The transporting mechanism can potentially be applied to miniaturize sample analysis system or " lab-on-chip" devices.

Sample handling↗

Grain Shape Characterization as an Enabling Capability for Lunar Surface Technologies

Lunar regolith has unique physical and geotechnical properties compared with familiar granular materials on Earth, and most lunar simulants as well. Specifically, the cohesion, angle of repose, and compressibility are much higher, and flowability is much lower for lunar regolith than otherwise similar terrestrial-derived materials[1,2]. There is confusion in the literature about the relative importance of vacuum, gravity, and inherent grain characteristics in driving these differences. Here we emphasize the importance of characterizing grain types and shapes for designing and test-ing lunar surface technologies, including for rover mobility, material handling, soil sampling, and heat transfer analyses. We demonstrate laboratory capabilities and preliminary studies, and outline further work to better characterize and simulate lunar grains to reduce risks for surface activities

K. M. Cannon↗

The CheMin X-ray Diffractometer on MSL Curiosity: A Decade of Mineralogical Observations from Gale Crater, Mars

For more than a decade, the CheMin X-ray Diffraction instrument on the Mars Science Laboratory rover Curiosity has been returning quantitative mineralogical data from Gale crater, Mars. CheMin receives and analyzes sieved soil and powdered rock samples from Curiosity’s Sample Acquisition / Sample Processing and Handling (SA/SPaH) system. To date, 38 samples have been analyzed over the course of a 28 km transit. These samples document more than 600 vertical meters of flat-lying lacustrine, fluvial and aeolian sediments that comprise the lower part of the central mound of Gale crater (commonly called Mt. Sharp).The principal mineralogy of the sediments is basaltic, with evidence of early and late-stage diagenetic overprinting. The rocks in many cases preserve most of their primary mineralogy and sedimentary features, suggesting that they were never strongly heated or deformed. Using aeolian soil composition as a proxy for the composition of the deposited and lithified sediment, it appears that in many cases the diagenetic changes observed are principally isochemical. Exceptions to this include secondary nodules, calcium sulfate veining and rare alteration halos. A striking hematite-rich feature in lower Mt. Sharp called Vera Rubin Ridge is interpreted to be lake sediment diagenetically altered by silica-poor fluids. A surprising and as yet poorly understood observation is that nearly all of the 3.7 Gyr old sedimentary rocks analyzed to date are comprised of 25-50% X-ray amorphous material. Overall, this 600 m vertical section of sedimentary rock explored in lower Mt. Sharp documents a perennial shallow lake environment grading upward into alternating lacustrine/fluvial and aeolian environments. The mineralogical changes observed going up-section include a transition from trioctahedral to dioctahedral clay minerals and a transition from magnetite to hematite. More recently, in the last 150 m of section, CheMin has documented an overall decrease in clay minerals and increase in Fe3+ oxides and oxyhydroxides. The mineralogical changes observed in Gale crater may document the gradual drying out and oxidation of the martian hydrosphere.

CHEMIN↗

A sampling-based optimization approach to handling environmental uncertainty for a planetary lander

Planning for unknown environments presents a number of technical challenges. The planner must ensure robustness to unknown phenomena and manage unpredictable variation in execution, all while operating in a capacity that maximizes its objective. Productivity in the face of these challenges re-quires an integrated approach to planning and execution that is capable of accomplishing goals, reacting to variation, and maximizing overall utility. We examine this problem in the context of a Europa Lander concept mission. We model the problem as a hierarchical task network, framing it as a utility maximization problem constrained on a depletable energy resource. We propose an uncertainty–sensitive deterministic planning framework that utilizes periodic replanning to better handle model uncertainty and variable execution. We demonstrate the efficacy of our framework through simulations of a Europa Lander concept mission in which our algorithm out-performs several baseline approaches in both utility maximization and robustness

Zilberstein, Shlomo↗