Search NASA⌕ Search

SEARCH · Search NASA

Results for “Science Applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Artificial Intelligence for Dynamic Phase Transitions in Materials [PowerPoint]

The presentation covers the following areas: emergent phenomena and non-equilibrium transitions in granular materials; materials science applications, including defects, interfaces and emergent phenomena; modeling with molecular dynamics simulations; principal component analysis (PCA); previous works; PCA applied to nonequilibrium transitions; PCA for varied quenched disorder; PCA incorporating particle velocity; and ending with a summary and impacts.

36 MATERIALS SCIENCE↗

Radiation hardness assessment of the charge-integrating hybrid pixel detector JUNGFRAU 1.0 for photon science

JUNGFRAU (adJUstiNg Gain detector FoR the Aramis User station) is a two-dimensional hybrid pixel detector for photon science applications in free electron lasers, particularly SwissFEL, and synchrotron light sources. JUNGFRAU is an automatic gain switching, charge-integrating detector which covers a dynamic range of more than 10{sup 4} photons of an energy of 12 keV with a good linearity, uniformity of response, and spatial resolving power. The JUNGFRAU 1.0 application-specific integrated circuit (ASIC) features a 256 × 256 pixel matrix of 75 × 75 μm{sup 2} pixels and is bump-bonded to a 320 μm thick Si sensor. Modules of 2 × 4 chips cover an area of about 4 × 8 cm{sup 2}. Readout rates in excess of 2 kHz enable linear count rate capabilities of 20 MHz (at 12 keV) and 50 MHz (at 5 keV). The tolerance of JUNGFRAU to radiation is a key issue to guarantee several years of operation at free electron lasers and synchrotrons. The radiation hardness of JUNGFRAU 1.0 is tested with synchrotron radiation up to 10 MGy of delivered dose. The effect of radiation-induced changes on the noise, baseline, gain, and gain switching is evaluated post-irradiation for both the ASIC and the hybridized assembly. The bare JUNGFRAU 1.0 chip can withstand doses as high as 10 MGy with minor changes to its noise and a reduction in the preamplifier gain. The hybridized assembly, in particular the sensor, is affected by the photon irradiation which mainly shows as an increase in the leakage current. Self-healing of the system is investigated during a period of 11 weeks after the delivery of the radiation dose. Annealing radiation-induced changes by bake-out at 100 °C is investigated. It is concluded that the JUNGFRAU 1.0 pixel is sufficiently radiation-hard for its envisioned applications at SwissFEL and synchrotron beam lines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstrating the viability of Lagrangian in situ reduction on supercomputers

Performing exploratory analysis and visualization of large-scale time-varying computational science applications is challenging due to inaccuracies that arise from under-resolved data. In recent years, Lagrangian representations of the vector field computed using in situ processing are being increasingly researched and have emerged as a potential solution to enable exploration. However, prior works have offered limited estimates of the encumbrance on the simulation code as they consider “theoretical” in situ environments. Further, the effectiveness of this approach varies based on the nature of the vector field, benefitting from an in-depth investigation for each application area. With this study, an extended version of Sane et al. (2021), we contribute an evaluation of Lagrangian analysis viability and efficacy for simulation codes executing at scale on a supercomputer. We investigated previously unexplored cosmology and seismology applications as well as conducted a performance benchmarking study by using a hydrodynamics mini-application targeting exascale computing. Here, to inform encumbrance, we integrated in situ infrastructure with simulation codes, and evaluated Lagrangian in situ reduction in representative homogeneous and heterogeneous HPC environments. To inform post hoc accuracy, we conducted a statistical analysis across a range of spatiotemporal configurations as well as a qualitative evaluation. Additionally, our study contributes cost estimates for distributed-memory post hoc reconstruction. In all, we demonstrate viability for each application — data reduction to less than 1% of the total data via Lagrangian representations, while maintaining accurate reconstruction and requiring under 10% of total execution time in over 90% of our experiments.

97 MATHEMATICS AND COMPUTING↗

Collaborative Research: Tomographic imaging of laser-plasma structures

The interaction of intense short laser pulses with ionized gases, or plasmas, underlies many applications such as acceleration of elementary particles, production of energy by laser fusion, generation of x-ray and far-infrared “terahertz” pulses for medical and materials probing, remote sensing of explosives and pollutants, and generation of guide stars. Such laser-plasma interactions create tiny electron density structures (analogous to the wake behind a boat) inside the plasma in the shape of waves, bubbles and filaments that move at the speed of light, and evolve as they propagate. Prior to recent work by the PI of this proposal, detailed knowledge of such structures came exclusively from intensive computer simulations. Now “snapshots” of these elusive, light-velocity structures can be taken in the laboratory using dynamic variant of holography, the technique used to produce ID cards and DVDs, and dynamic variant of tomography, the technique used in medicine to image internal bodily organs. These fast visualization techniques are important for understanding, improving and scaling the above-mentioned applications of laser-plasma interactions. In this project, we accomplished three things: 1) We took holographic pictures of a laser-driven plasma-wave in the act of accelerating electrons to high energy, and used computer simulations to understand the pictures. 2) Using results from this experiment to optimize the performance of the accelerator, and the brightness of x-rays that it emits. These x-rays will be useful for medical and materials science applications. 3) We made technical improvements to the holographic technique that enables us to see finer details in the recorded pictures. Four refereed journal papers were published, and two students earned PhDs and moved on to scientific careers in US National Laboratories based on their work under this project.

43 PARTICLE ACCELERATORS↗

CosmoFlow: Using Deep Learning to Learn the Universe at Scale

Deep learning is a promising tool to determine the physical model that describes our universe. To handle the considerable computational cost of this problem, we present CosmoFlow: a highly scalable deep learning application built on top of the TensorFlow framework. CosmoFlow uses efficient implementations of 3D convolution and pooling primitives, together with improvements in threading for many element-wise operations, to improve training performance on Intel ® Xeon Phi™ processors. We also utilize the Cray PE Machine Learning Plugin for efficient scaling to multiple nodes. We demonstrate fully synchronous data-parallel training on 8192 nodes of Cori with 77% parallel efficiency, achieving 3.5 Pflop/s sustained performance. To our knowledge, this is the first large-scale science application of the TensorFlow framework at supercomputer scale with fully-synchronous training. Here, these enhancements enable us to process large 3D dark matter distribution and predict the cosmological parameters Ω M , σ 8 and n s with unprecedented accuracy.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Applications of C 7 LYC scintillators in fast neutron spectroscopy

Here, the capabilities of 7 Li-enriched Cs 2 7 LiYCl 6 (C 7 LYC) scintillation detectors for fast neutron spectroscopy are explored in benchmark experiments that exploit its excellent pulse-shape discrimination between neutrons and γ rays, and its unprecedented ≈10% energy resolution for fast neutrons in the few MeV range, obtained through the 35 Cl(n,p) reaction. Energy- and angle-resolved elastic and inelastic neutron scattering cross-section measurements of 56 Fe(n,n’) were performed at Los Alamos National Laboratory with a pulsed white neutron source and an array of 1" x 1" C 7 LYC crystals. The results convincingly establish the utility of this dual n/γ scintillator for fast neutron spectroscopy. Intrinsic efficiency measurements of both 1" x 1" and the first ever 3" x 3" C 7 LYC crystal have been initiated, using mono-energetic fast neutron beams at UMass Lowell generated via the 7 Li(p,n) reaction. Finally, the spectroscopic capabilities and potential of C 7 LYC are discussed in the context of developing this emerging scintillator for targeted science applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poincaré beams from a free electron laser

Poincaré beams are light beams that have spatially inhomogeneous polarization structure that spans a finite portion of the Poincaré sphere. This feature bestows the beams with intriguing topological properties and has led to a surge in research on their fundamental characteristics, their controlled generation and on emerging applications. Here we present an experimental demonstration of a Poincaré beam generated in the extreme ultraviolet (16.7 nm) at the FERMI free electron laser (FEL). The ‘star’ type Poincaré beam is generated by exploiting the phase and intensity structure intrinsic to FEL radiation without relying on optical elements. Here, we controlled the spatial polarization distribution through a precise overlap and power balance between two FEL pulses, each with different transverse phase distributions and orthogonal circular polarizations. The spatial polarization structure was mapped in detail and shows extensive coverage of the Poincaré sphere, in agreement with analytic predictions. This method of in situ Poincaré beam production in FELs enables straightforward flexibility in the orientation and balance of polarization states, and can readily be extended to other vector beams and to shorter wavelengths enabling novel science applications in modern light sources.

Morgan, Jenny [SLAC National Accelerator Laborator↗

An Advanced Network and distributed Storage Laboratory (ANDSL) for Data Intensive Science (Final Report)

The original intent of this project was to build and operate an Advanced Network and Distributed Storage Laboratory (ANDSL) for Data Intensive Science that will prepare the Open Science Grid (OSG) community for a new generation of wide area communication capabilities operating at a 100Gb rate. The plan was to engage a team of four dedicated scientists that will design, develop and operate a state of the art laboratory that will be fully integrated into the organizational and operational infrastructure of the OSG. The ANDSL was planned to include host-based hardware and software required to profile, emulate and study real-life distributed storage workloads at rates of 100 Gbps. The laboratory was designed to utilize the Department Of Energy’s Advanced Network Initiative (ANI) 100GbTestbed as connections to the fabric become available so that OSG stakeholders can use it to profile real-life data intensive science applications as well as experiment with advanced storage and data management technologies. The goal of the original program of work was to close the adoption gap, decreasing the time between availability of production 100Gbps links and the end-to-end use of such a network to enable scientific discovery.

100Gb networks↗

Analysis of full charge reconstruction algorithms for x-ray pixelated detectors

Existence of the natural diffusive spread of charge carriers on the course of their drift towards collecting electrodes in planar, segmented detectors results in a division of the original cloud of carriers between neighboring channels. This paper presents the analysis of algorithms, implementable with reasonable circuit resources, whose task is to prevent degradation of the detective quantum efficiency in highly granular, digital pixel detectors. The immediate motivation of the work is a photon science application requesting simultaneous timing spectroscopy and 2D position sensitivity. Leading edge discrimination, provided it can be freed from uncertainties associated with the charge sharing, is used for timing the events. Analyzed solutions can naturally be extended to the amplitude spectroscopy with pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of Full Charge Reconstruction Algorithms for X-Ray Pixelated Detectors

Existence of the natural diffusive spread of charge carriers on the course of their drift towards collecting electrodes in planar, segmented detectors results in a division of the original cloud of carriers between neighboring channels. This paper presents the analysis of algorithms, implementable with reasonable circuit resources, whose task is to prevent degradation of the detective quantum efficiency in highly granular, digital pixel detectors. The immediate motivation of the work is a photon science application requesting simultaneous timing spectroscopy and 2D position sensitivity. Leading edge discrimination, provided it can be freed from uncertainties associated with the charge sharing, is used for timing the events. Analyzed solutions can naturally be extended to the amplitude spectroscopy with pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Metal-enhanced chemiluminescence from chromium, copper, nickel, and zinc nanodeposits: Evidence for a second enhancement mechanism in metal-enhanced fluorescence

Over the past decade metal-fluorophore interactions, metal-enhanced fluorescence, have attracted significant research attention, with the technology now becoming common place in life science applications. In this paper, we address the underlying mechanisms of metal-enhanced fluorescence (MEF) and experimentally show using chemiluminescence solutions that MEF is indeed underpinned by two complimentary mechanisms, consistent with the recent reports by Geddes and co-workers [Zhang et al., J. Phys. Chem. C 113, 12095 (2009)] and their enhanced fluorescence hypothesis.

36 MATERIALS SCIENCE↗

An information-matching approach to optimal experimental design and active learning

The efficacy of mathematical models heavily depends on the quality of the training data, yet collecting sufficient data is often expensive and challenging. Many modeling applications require inferring parameters only as a means to predict other quantities of interest (QoI). Because models often contain many unidentifiable (sloppy) parameters, QoIs often depend on a relatively small number of parameter combinations. Therefore, we introduce an information-matching criterion based on the Fisher information matrix to select the most informative training data from a candidate pool. This method ensures that the selected data contain sufficient information to learn only those parameters that are needed to constrain downstream QoIs. It is formulated as a convex optimization problem, making it scalable to large models and datasets. Here, we demonstrate the effectiveness of this approach across various modeling problems in diverse scientific fields, including power systems and underwater acoustics. Finally, we use information-matching as a query function within an active learning (AL) loop for materials science applications. In all these applications, we find that a relatively small set of optimal training data can provide the necessary information for achieving precise predictions. These results are encouraging for diverse future applications, particularly AL in large machine-learning models.

Materials science↗

3He and BF3 Neutron Detector Pressure Effect and Model Comparison

Paper for SORMA conference Radiation detection systems for homeland security applications must possess the capability of detecting both gamma rays and neutrons. The radiation portal monitor (RPM) systems that are currently deployed use a plastic scintillator for detecting gamma rays and 3He gas-filled proportional counters for detecting neutrons. Proportional counters filled with 3He are the preferred neutron detectors for use in RPMs because 3He has a large neutron cross section, is relatively insensitive to gamma-rays, is neither toxic nor corrosive, can withstand extreme environments, and can be operated at a lower voltage than some of the alternative proportional counters. The amount of 3He required for homeland security and science applications has depleted the world supply and there is no longer enough available to fill the demand. Thus, alternative neutron detectors are being explored. Two possible temporary solutions that could be utilized while a more permanent solution is being identified are reducing the 3He pressure in the proportional counters and using boron trifluoride (BF3) gas-filled proportional counters. Reducing the amount of 3He required in each of the proportional counters would decrease the rate at which 3He is being used, not enough to solve the shortage but perhaps enough to increase the amount of time available to find a working replacement. BF3 is not appropriate for all situations as these detectors are less sensitive than 3He, BF3 gas is corrosive, and a much higher voltage is required than what is used with 3He detectors. Measurements of the neutron detection efficiency of 3He and BF3 as a function of tube pressure were made. The experimental results were also used to validate models of the RPMs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fundamentals and Applications of Hybrid LWFA-PWFA

Fundamental similarities and differences between laser-driven plasma wakefield acceleration (LWFA) and particle-driven plasma wakefield acceleration (PWFA) are discussed. The complementary features enable the conception and development of novel hybrid plasma accelerators, which allow previously not accessible compact solutions for high quality electron bunch generation and arising applications. Very high energy gains can be realized by electron beam drivers even in single stages because PWFA is practically dephasing-free and not diffraction-limited. These electron driver beams for PWFA in turn can be produced in compact LWFA stages. In various hybrid approaches, these PWFA systems can be spiked with ionizing laser pulses to realize tunable and high-quality electron sources via optical density downramp injection (also known as plasma torch) or plasma photocathodes (also known as Trojan Horse) and via wakefield-induced injection (also known as WII). These hybrids can act as beam energy, brightness and quality transformers, and partially have built-in stabilizing features. They thus offer compact pathways towards beams with unprecedented emittance and brightness, which may have transformative impact for light sources and photon science applications. Furthermore, they allow the study of PWFA-specific challenges in compact setups in addition to large linac-based facilities, such as fundamental beam–plasma interaction physics, to develop novel diagnostics, and to develop contributions such as ultralow emittance test beams or other building blocks and schemes which support future plasma-based collider concepts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Leveraging generative AI for urban digital twins: a scoping review on the autonomous generation of urban data, scenarios, designs, and 3D city models for smart city advancement

The digital transformation of modern cities by integrating advanced information, communication, and computing technologies has marked the epoch of data-driven smart city applications for efficient and sustainable urban management. Despite their effectiveness, these applications often rely on massive amounts of high-dimensional and multi-domain data for monitoring and characterizing different urban sub-systems, presenting challenges in application areas that are limited by data quality and availability, as well as costly efforts for generating urban scenarios and design alternatives. As an emerging research area in deep learning, Generative Artificial Intelligence (GenAI) models have demonstrated their unique values in content generation. This paper aims to explore the innovative integration of GenAI techniques and urban digital twins to address challenges in the planning and management of built environments with focuses on various urban sub-systems, such as transportation, energy, water, and building and infrastructure. The survey starts with the introduction of cutting-edge generative AI models, such as the Generative Adversarial Networks (GAN), Variational Autoencoders (VAEs), Generative Pre-trained Transformer (GPT), followed by a scoping review of the existing urban science applications that leverage the intelligent and autonomous capability of these techniques to facilitate the research, operations, and management of critical urban subsystems, as well as the holistic planning and design of the built environment. Based on the review, we discuss potential opportunities and technical strategies that integrate GenAI models into the next-generation urban digital twins for more intelligent, scalable, and automated smart city development and management.

3D city modeling↗

Report on ISR-1 High-Altitude Balloon Flight

To test small technologies at lower cost for space science applications, LANL has developed a small high altitude balloon payload that could, in the future, be regularly and inexpensively launched from LANL. A neutron detector, NEMO, was integrated to evaluate its performance in a space-like mixed-radiation environment and collect neutron data in the atmosphere. In collaboration with EES-14, a high-altitude balloon payload was launched from LANL Technical Area 51 on February 27, 2023 and April 17, 2023. For real-time geolocation, a SAM-M8Q M8 GNSS module was used to get position and time, and an Iridium RockBLOCK 9603 was used to communicate with the ground using the Iridium satellite fleet. These modules were all controlled using an Iteaduino Mega microcontroller board. Finally, a High Altitude Science Eagle Flight Computer with a temperature pressure sensor ran independently, writing data to an SD card. All of these modules were powered by a 5 mAh lithium polymer battery. The battery was attached to the bottom of the payload while the remaining electronics were embedded in the underside of the top of the payload. These modules were wired as seen in Figure 1-2. The Iteaduino Mega microcontroller board was programmed to use the RockBLOCK to send a message once every 10 minutes containing neutron and GPS data read off the NEMO and SAM M8Q, respectively. Once the message send attempt finished, the RockBLOCK would be slept for the rest of the 10 minute interval. The Eagle Flight Computer ran continuously throughout the flight, taking data every 6 seconds. The RockBLOCK message data was set up to be delivered from the Iridium satellite fleet to a website, where it was stored and parsed to create live maps and plots for analysis and balloon retrieval. The RockBLOCK message data was additionally configured to be sent to an email as a fail-safe. The payload was ground-tested successfully for over 50 hours, with multiple revisions occurring to best prepare for conditions at altitude and improve the software and firmware to fix any issues that cropped up with the data pipeline. Additional to the balloon payload, the flight had an attached iMet-4 radiosonde and Garmin T5 GPS Dog Collar. The radiosonde provided GPS and meteorological data. The T5 dog collar is used along with a Garmin Astro 430 to track the balloon at a range of up to 9 miles for retrieval. The balloon itself was initially a 1600 g meteorological balloon with an attached High Altitude Science parachute, both of which can be seen in Figure 1-3. After the first flight, the EES team swapped to a Rocketman parachute.

42 ENGINEERING↗

Tin–Lead Liquid Metal Alloy Source for Focused Ion Beams

Focused Ion Beam (FIB) systems are increasingly utilized in nanotechnology for nanostructuring, surface modification, doping, and rapid prototyping. Recently, their potential for quantum applications has been explored, leveraging FIB’s direct-write capabilities for in situ single ion implantation, which is crucial for fabricating single photon emitters. Color centers in diamond can function as qubits and are of particular interest due to their capacity to store and transmit quantum information. While Group-IV color centers exhibit high brightness, they require low temperatures to retain coherence. However, lead-vacancy in diamond (PbV) operates at the higher end (4 K) of this temperature spectrum due to larger ground-state splitting, making them particularly interesting. In this context, our study presents results for lead (Pb)-containing alloys with eutectic points below 600 °C and results on using tantalum (Ta) and titanium (Ti) as emitter materials for a Pb liquid metal alloy ion source. We show that a standard FIB system is able to resolve the different Pb isotopes and achieve nanoscale spot sizes, as required for quantum information science applications.

color center↗

The development of GPU-based parallel PRNG for Monte Carlo applications in CUDA Fortran

The implementation of Monte Carlo simulation on the CUDA Fortran requires a fast random number generation with good statistical properties on GPU. In this study, a GPU-based parallel pseudo random number generator (GPPRNG) have been proposed to use in high performance computing systems. According to the type of GPU memory usage, GPU scheme is divided into two work modes including GLOBAL-MODE and SHARED-MODE. To generate parallel random numbers based on the independent sequence method, the combination of middle-square method and chaotic map along with the Xorshift PRNG have been employed. Implementation of our developed PPRNG on a single GPU showed a speedup of 150x and 470x (with respect to the speed of PRNG on a single CPU core) for GLOBAL-MODE and SHARED-MODE, respectively. To evaluate the accuracy of our developed GPPRNG, its performance was compared to that of some other commercially available PPRNGs such as MATLAB, FORTRAN and Miller-Park algorithm through employing the specific standard tests. The results of this comparison showed that the developed GPPRNG in this study can be used as a fast and accurate tool for computational science applications.

97 MATHEMATICS AND COMPUTING↗