At least 217 records · Page 12

The Intelsat 4 antenna positioner

The Intelsat 4 communications satellite has two spot beam antennas which are pointed to selected land masses by gimbaled positioners. The positioners employ drive motors with electromagnetic brakes and jackscrews that are self-caging during the launch. The positioner uses dry lubricants for ball bearings, spur gears, screw and nut, and various journal bearings. A coefficient of friction of approximately 0.05 was demonstrated in vacuum operation. Success of the positioner was demonstrated on the first Intelsat 4 placed in orbit in January 1971. The developmental problems that were encountered and their solutions are discussed.

Glassow, F. A.↗

Dielectric siphons.

The normally weak polarization force density, exerted on insulating dielectric liquids by a nonuniform electric field, is enhanced if high pressures are used. The nonuniform electric field acts as an elastic ?wall' to contain and guide the dielectric fluid. A general theory for these electrohydrodynamic (EHD) conduits has been developed. An illustrative example of the EHD conduits is the dielectric siphon consisting of two U-shaped electrodes held adjacent to each other by insulating nylon screws.

Jones, T. B.↗

Arterial and grooved cryogenic heat pipes.

Tests were conducted on two cryogenic heat pipes using nitrogen as the working fluid. Both pipes are 1.27 cm in diameter. The first pipe is 141 cm long and uses longitudinal grooves in the aluminum wall as the wick structure. The second pipe is 91 cm long and has an arterial wick adjacent to the wall. In addition, circumferential screw threads are machined along the entire length of the inside pipe wall. Both heat pipes primed with no difficulty in the horizontal position. Start-up after burn-out was obtained repeatedly. However, more testing is required to determine whether the artery pipe is as reliable as the grooved pipe with respect to priming. Once primed, the artery heat pipe is much less sensitive to elevation than the grooved design and, consequently, offers a significant advantage with respect to ground testing. Heat-transfer characteristics of the two pipes were comparable, with both pipes achieving the initial goal of 1000 watt-cm of heat-transport capability.

Brennan, P.↗

Redundant screwjack

Device uses differential gears to drive either one of two nut-screw assemblies. In event that one assembly jams, second assembly is driven at twice its normal rate with no loss in overall performance.

Benjamin, R. W.↗

Modular support blocks for fluid lines

Modular line block comprises matched modular elements machined to accept fluid lines of different diameters. Modules can support different fluid-line configurations. Top and bottom surfaces are machined to accept dovetail strip used for holding modules together. End modules have holes drilled through to accept fastening screws.

Dimino, J. M.↗

Internal friction measurement in high purity tungsten single crystal

Internal friction peaks observed after small deformation in high purity tungsten single crystals between liquid helium temperature and 800 K in the frequency range 30-50 KHz, are studied as a function of orientation. An orientation effect is observed in the internal friction spectra due to the creation of internal stresses. The elementary processes related to these peaks are discussed in terms of kink generation and geometric kink motion on screw and edge dislocations in an internal stress field.

Rieu, G. E.↗

Development and investigation of single-scan TV radiography for the acquisition of dynamic physiologic data

Research data obtained by the low dose electronic radiography system are reported. Data cover: (1) localization and tracking of Ta screws implanted in the inner wall of the right ventrical of the heart, (2) use of cross hairs to outline inner or outer heart wall contours, (3) quantitative measure of anatomical components which are stationary in size or change size dynamically, and (4) study of dynamic quantitative data from roentenologic or fluoroscopic procedures.

Baily, N. A.↗

Single reflector interference spectrometer and drive system therefor

In a Fourier interference spectrometer of the doublepass retroreflector type, a single mirror is employed in the path of both split beams of an incoming ray to cause them to double back through separate retroreflectors. Changes in optical path length are achieved by linear displacement of both retroreflectors using a motor driven lead screw on one for large, low frequency changes, a moving-coil actuator on the other for smaller, mid-frequency changes and a piezoelectric actuator on one of these two for small, high frequency changes.

Schindler, R. A.↗

Analysis of the dynamics and frequency spectrum synthesis of an optical-mechanical scanning device

A two-coordinate optical-mechanical scanning device (OMSD), the operating unit of which is a scanning disk, with directional and focusing optics and a board, on which the data carrier is placed, is examined. The disk and board are kinematically connected by a transmission mechanism, consisting of a worm and complex gear drive and a tightening screw-nut with correcting device, and it is run by a synchronous type motor. The dynamic errors in the system depend, first, on irregularities in rotation of the disk, fluctuations in its axis and vibrations of the table in the plane parallel to the plane of the disk. The basic sources of the fluctuations referred to above are residual disbalance of the rotor and other rotating masses, the periodic component of the driving torque of the synchronous motor, variability in the resistance, kinematic errors in the drive and other things. The fluctuations can be transmitted to the operating units through the kinematic link as a flexural-torsional system, as well as through vibrations of the housing of the device.

Andryushkevichyus, A. I.↗

The motion of interconnected flexible bodies

The equations of motion for an arbitrarily interconnected collection of substructures are derived. The substructures are elastic bodies which may be idealized as finite element assemblies and are subject to small deformations relative to a nominal state. Interconnections between the elastic substructures permit large relative translations and rotations between substructures, governed by Pfaffian constraints describing the connections. Screw connections (permitting rotation about and translation along a single axis) eliminate constraint forces and incorporate modal coupling. The problem of flexible spacecraft simulation is discussed. Hurty's component mode approach is extended by permitting interconnected elastic substructures large motions relative to each other and relative to inertial space. The hybrid coordinate methods are generalized by permitting all substructures to be flexible (rather than only the terminal members of a topological tree of substructures). The basic relationships of continuum mechanics are developed.

Hopkins, A. S.↗

The self streamlining wind tunnel

A two dimensional test section in a low speed wind tunnel capable of producing flow conditions free from wall interference is presented. Flexible top and bottom walls, and rigid sidewalls from which models were mounted spanning the tunnel are shown. All walls were unperforated, and the flexible walls were positioned by screw jacks. To eliminate wall interference, the wind tunnel itself supplied the information required in the streamlining process, when run with the model present. Measurements taken at the flexible walls were used by the tunnels computer check wall contours. Suitable adjustments based on streamlining criteria were then suggested by the computer. The streamlining criterion adopted when generating infinite flowfield conditions was a matching of static pressures in the test section at a wall with pressures computed for an imaginary inviscid flowfield passing over the outside of the same wall. Aerodynamic data taken on a cylindrical model operating under high blockage conditions are presented to illustrate the operation of the tunnel in its various modes.

Goodyer, M. J.↗

Special report: Occlusive cuff controller

A mechanical occlusive cuff controller suitable for blood flow experiments in space shuttle flights is described. The device requires 115 volt ac power and a pressurized gas source. Two occluding cuff pressures (30 and 50 mmHg) are selectable by a switch on the front panel. A screw driver adjustment allows accurate cuff pressurization levels for under or oversized limbs. Two pressurization cycles (20 second and 2 minutes) can be selected by a front panel switch. Adjustment of the timing cycles is also available through the front panel. A pushbutton hand switch allows remote start of the cuff inflation cycle. A stop/reset switch permits early termination of the cycle and disabling of the controller to prevent inadvertent reactivation. Pressure in the cuff is monitored by a differential aneroid barometer. In addition, an electrocardiogram trigger circuit permits the initiation of the pressurization cycle by an externally supplied ECG cycle.

Baker, J. T.↗

Improved interferometer beam splitter

Cat's-eye retroreflector attached to motor driven lead screw allows low-frequency changes in optical path. Moving-coil actuator attached to other retroreflector allows mid-frequency movements. High-frequency movements are achieved by employing piezoelectric transducer attached to secondary mirror of same retroreflector.

Schindler, R. A.↗

Fabrication of ultra-low-noise amplifier

Three construction techniques reduce noise temperature of microwave parametric amplifier. Techniques include electroformed idler cavity, screw-tuned idler, and low-loss matching section.

Kraemer, E.↗

Automated parking garage system model

A one-twenty-fifth scale model of the key components of an automated parking garage system is described. The design of the model required transferring a vehicle from an entry level, vertically (+Z, -Z), to a storage location at any one of four storage positions (+X, -X, +Y, +Y, -Y) on the storage levels. There are three primary subsystems: (1) a screw jack to provide the vertical motion of the elevator, (2) a cam-driven track-switching device to provide X to Y motion, and (3) a transfer cart to provide horizontal travel and a small amount to vertical motion for transfer to the storage location. Motive power is provided by dc permanent magnet gear motors, one each for the elevator and track switching device and two for the transfer cart drive system (one driving the cart horizontally and the other providing the vertical transfer). The control system, through the use of a microprocessor, provides complete automation through a feedback system which utilizes sensing devices.

Collins, E. R., Jr.↗

A low speed self streamlining wind tunnel

A two dimensional test section in a low speed wind tunnel is producing flow conditions free from wall interference. The test section has flexible top and bottom walls, and rigid sidewalls from which the models are mounted spanning the tunnel. All walls are unperforated, and the flexible walls are positioned by screw jacks. To eliminate wall interference, the wind tunnel itself supplies the information required in this streamlining process, when run with the model present. Measurements taken at the flexible walls are used by the tunnel computer to check wall contours. When the static pressure distribution in the test section along a contoured flexible wall matches that computed for an imaginary flow field passing over the outside of the same contour, the wall is a streamline in an infinite flow field and the test section flow is free from wall interference. A series of iterations brings the walls from straight to streamlines. Illustrative aerodynamic data is presented, taken on a bluff body and a lifting wing.

Goodyer, M. J.↗

Skin-implant multiwire connector

Construction of device utilizing high-purity carbon is biocompatible as well as hygienic, Design allows for easy connections and disconnections in dark, cleaning and maintenance and less snagging of clothing and other articles by device. Guides and magnetic coupling preclude need for locks, screwing, or latching.

Owens, L. J.↗