Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity and Specificity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Dynamic Probabilistic Instability of Composite Structures

A computationally effective method is described to evaluate the non-deterministic dynamic instability (probabilistic dynamic buckling) of thin composite shells. The method is a judicious combination of available computer codes for finite element, composite mechanics and probabilistic structural analysis. The solution method is incrementally updated Lagrangian. It is illustrated by applying it to thin composite cylindrical shell subjected to dynamic loads. Both deterministic and probabilistic buckling loads are evaluated to demonstrate the effectiveness of the method. A universal plot is obtained for the specific shell that can be used to approximate buckling loads for different load rates and different probability levels. Results from this plot show that the faster the rate, the higher the buckling load and the shorter the time. The lower the probability, the lower is the buckling load for a specific time. Probabilistic sensitivity results show that the ply thickness, the fiber volume ratio and the fiber longitudinal modulus, dynamic load and loading rate are the dominant uncertainties in that order.

Chamis, Christos C.↗

Electrochemical Detection of Multiple Bioprocess Analytes

An apparatus that includes highly miniaturized thin-film electrochemical sensor array has been demonstrated as a prototype of instruments for simultaneous detection of multiple substances of interest (analytes) and measurement of acidity or alkalinity in bioprocess streams. Measurements of pH and of concentrations of nutrients and wastes in cell-culture media, made by use of these instruments, are to be used as feedback for optimizing the growth of cells or the production of desired substances by the cultured cells. The apparatus is designed to utilize samples of minimal volume so as to minimize any perturbation of monitored processes. The apparatus can function in a potentiometric mode (for measuring pH), an amperometric mode (detecting analytes via oxidation/reduction reactions), or both. The sensor array is planar and includes multiple thin-film microelectrodes covered with hydrous iridium oxide. The oxide layer on each electrode serves as both a protective and electrochemical transducing layer. In its transducing role, the oxide provides electrical conductivity for amperometric measurement or pH response for potentiometric measurement. The oxide on an electrode can also serve as a matrix for one or more enzymes that render the electrode sensitive to a specific analyte. In addition to transducing electrodes, the array includes electrodes for potential control. The array can be fabricated by techniques familiar to the microelectronics industry. The sensor array is housed in a thin-film liquid-flow cell that has a total volume of about 100 mL. The flow cell is connected to a computer-controlled subsystem that periodically draws samples from the bioprocess stream to be monitored. Before entering the cell, each 100-mL sample is subjected to tangential-flow filtration to remove particles. In the present version of the apparatus, the electrodes are operated under control by a potentiostat and are used to simultaneously measure the pH and the concentration of glucose. It is anticipated that development of procedures for trapping more enzymes into hydrous iridium oxide (and possibly into other electroactive metal oxides) and of means for imparting long-term stability to the transducer layers should make it possible to monitor concentrations of products of many enzyme reactions for example, such key bioprocess analytes as amino acids, vitamins, lactose, and acetate.

Rauh, R. David↗

Advanced Electrocardiography Can Identify Occult Cardiomyopathy in Doberman Pinschers

Recently, multiple advanced resting electrocardiographic (A-ECG) techniques have improved the diagnostic value of short-duration ECG in detection of dilated cardiomyopathy (DCM) in humans. This study investigated whether 12-lead A-ECG recordings could accurately identify the occult phase of DCM in dogs. Short-duration (3-5 min) high-fidelity 12-lead ECG recordings were obtained from 31 privately-owned, clinically healthy Doberman Pinschers (5.4 +/- 1.7 years, 11/20 males/females). Dogs were divided into 2 groups: 1) 19 healthy dogs with normal echocardiographic M-mode measurements: left ventricular internal diameter in diastole (LVIDd . 47mm) and in systole (LVIDs . 38mm) and normal 24-hour ECG recordings (<50 ventricular premature complexes, VPCs); and 2) 12 dogs with occult DCM: 11/12 dogs had increased M-mode measurements (LVIDd . 49mm and/or LVIDs . 40mm) and 5/11 dogs had also >100 VPCs/24h; 1/12 dogs had only abnormal 24-hour ECG recordings (>100 VPCs/24h). ECG recordings were evaluated via custom software programs to calculate multiple parameters of high-frequency (HF) QRS ECG, heart rate variability, QT variability, waveform complexity and 3-D ECG. Student's t-tests determined 19 ECG parameters that were significantly different (P < 0.05) between groups. Principal component factor analysis identified a 5-factor model with 81.4% explained variance. QRS dipolar and non-dipolar voltages, Cornell voltage criteria and QRS waveform residuum were increased significantly (P < 0.05), whereas mean HF QRS amplitude was decreased significantly (P < 0.05) in dogs with occult DCM. For the 5 selected parameters the prediction of occult DCM was performed using a binary logistic regression model with Chi-square tested significance (P < 0.01). ROC analyses showed that the five selected ECG parameters could identify occult ECG with sensitivity 89% and specificity 83%. Results suggest that 12-lead A-ECG might improve diagnostic value of short-duration ECG in earlier detection of canine DCM as five selected ECG parameters can with reasonable accuracy identify occult DCM in Doberman Pinschers. Future extensive clinical studies need to clarify if 12-lead A-ECG could be useful as an additional screening test for canine DCM.

Spiljak, M.↗

Rapid Detection of Herpes Viruses for Clinical Applications

There are eight herpes viruses that infect humans, causing a wide range of diseases resulting in considerable morbidity and associated costs. Varicella zoster virus (VZV) is a human herpes virus that causes chickenpox in children and shingles in adults. Approximately 1,000,000 new cases of shingles occur each year; post-herpetic neuralgia (PHN) follows shingles in 100,000 to 200,000 people annually. PHN is characterized by debilitating, nearly unbearable pain for weeks, months, and even years. The onset of shingles is characterized by pain, followed by the zoster rash, leading to blisters and severe pain. The problem is that in the early stages, shingles can be difficult to diagnose; chickenpox in adults can be equally difficult to diagnose. As a result, both diseases can be misdiagnosed (false positive/negative). A molecular assay has been adapted for use in diagnosing VZV diseases. The polymerase chain reaction (PCR) assay is a non-invasive, rapid, sensitive, and highly specific method for VZV DNA detection. It provides unequivocal results and can effectively end misdiagnoses. This is an approximately two-hour assay that allows unequivocal diagnosis and rapid antiviral drug intervention. It has been demonstrated that rapid intervention can prevent full development of the disease, resulting in reduced likelihood of PHN. The technology was extended to shingles patients and demonstrated that VZV is shed in saliva and blood of all shingles patients. The amount of VZV in saliva parallels the medical outcome.

Pierson, Duane↗

Conceptual Design of a Single-Aisle Turboelectric Commercial Transport With Fuselage Boundary Layer Ingestion

A single-aisle commercial transport concept with a turboelectric propulsion system architecture was developed assuming entry into service in 2035 and compared to a similar technology conventional configuration. The turboelectric architecture consisted of two underwing turbofans with generators extracting power from the fan shaft and sending it to a rear fuselage, axisymmetric, boundary layer ingesting fan. Results indicate that the turbo- electric concept has an economic mission fuel burn reduction of 7%, and a design mission fuel burn reduction of 12% compared to the conventional configuration. An exploration of the design space was performed to better understand how the turboelectric architecture changes the design space, and system sensitivities were run to determine the sensitivity of thrust specific fuel consumption at top of climb and propulsion system weight to the motor power, fan pressure ratio, and electrical transmission efficiency of the aft boundary layer ingesting fan.

Welstead, Jason R.↗

Constraining the Sulfur Dioxide Degassing Flux from Turrialba Volcano, Costa Rica Using Unmanned Aerial System Measurements

Observed sulfur dioxide (SO2)mixing ratios onboard unmanned aerial systems (UAS) duringMarch 11-13, 2013 are used to constrain the three-day averaged SO2 degassing flux fromTurrialba volcanowithin a Bayesian inverse modeling framework. A mesoscale model coupled with Lagrangian stochastic particle backward trajectories is used to quantify the source-receptor relationships at very high spatial resolutions (i.e., b1 km). The model shows better performance in reproducing the near-surface meteorological properties and observed SO2 variations when using a first-order closure non-local planetary boundary layer (PBL) scheme. The optimized SO2 degassing fluxes vary from 0.59 +/- 0.37 to 0.83 +/- 0.33 kt d−1 depending on the PBL scheme used. These fluxes are in good agreement with ground-based gas flux measurements, and correspond to corrective scale factors of 8-12 to the posteruptive SO2 degassing rate in the AeroCom emission inventory. The maximum a posteriori solution for the SO2 flux is highly sensitive to the specification of prior and observational errors, and relatively insensitive to the SO2 loss term and temporal averaging of observations. Our results indicate relatively low degassing activity but sustained sulfur emissions from Turrialba volcano to the troposphere during March 2013. This study demonstrates the utility of low-cost small UAS platforms for volcanic gas composition and flux analysis.

Xi, Xin↗

The Effects of Normal Metal Stripes on TES Performance

Exploring the effects of size and geometry of normal metal features on the transition shapes and performance of transition-edge sensor microcalorimeters. The spectral resolution of transition-edge sensor (TES) microcalorimeters is very sensitive to the specific dependencies of the resistance R in the superconducting transition on the current I, magnetic field B, and temperature T. In particular, it has been shown that transitions that are very steep in (R,T) space lead to a significant noise term, in excess of conventional expectations. This so-called unexplained noise is known to be reduced by the addition of normal metal stripes across the TES perpendicular to the direction of current flow. These normal metal stripes have been shown to drastically alter the oscillatory patterns seen in measurements of the critical current as a function of magnetic field. However, there are many remaining questions about the exact impact of the stripes on current distributions within the TES, the Fraunhofer pattern and, therefore, the shape of the R(I, B, T) surface. Through measurements of the resistance under DC bias of TES devices of various sizes, with different stripe patterns and dimensions, we will discuss how these stripes can affect the R(I, B, T) surface. In addition, using measurements and analysis of the noise spectra of various devices we will present how these changes to the stripe pattern may affect the performance of the TES. In particular, we will discuss strategies to reduce the presence of localized discontinuities in the derivative of R, associated with increased noise, while maintaining the globally low levels of unexplained noise currently achieved with conventional metal stripe patterns. Implementing these strategies is a path towards producing large arrays with highly uniform transitions and high spectral resolution. These large uniform arrays will be required for future x-ray astronomy applications, such as the X-IFU on ATHENA.

TES↗

Pixel-Level Calibration in the Kepler Science Operations Center Pipeline

We present an overview of the pixel-level calibration of flight data from the Kepler Mission performed within the Kepler Science Operations Center Science Processing Pipeline. This article describes the calibration (CAL) module, which operates on original spacecraft data to remove instrument effects and other artifacts that pollute the data. Traditional CCD data reduction is performed (removal of instrument/detector effects such as bias and dark current), in addition to pixel-level calibration (correcting for cosmic rays and variations in pixel sensitivity), Kepler-specific corrections (removing smear signals which result from the lack of a shutter on the photometer and correcting for distortions induced by the readout electronics), and additional operations that are needed due to the complexity and large volume of flight data. CAL operates on long (~30 min) and short (~1 min) sampled data, as well as full-frame images, and produces calibrated pixel flux time series, uncertainties, and other metrics that are used in subsequent Pipeline modules. The raw and calibrated data are also archived in the Multi-mission Archive at Space Telescope at the Space Telescope Science Institute for use by the astronomical community.

Calibration↗

Concept Study for a Compact Planetary Homodyne Interferometer (PHI) for Temporal Global Observation of Methane on Mars in IR

We present a concept study to develop a new instrument to sequentially and over a long time measure methane abundance on Mars and find out its global seasonal variations, if any. The Planetary Homodyne Interferometer (PHI) can offer integrated spectra over a wide field-of-view (FOV) in high spectral resolution (R~10(exp 5)) in a compact design using no (or a small < 1m) primary mirror. PHI is best suited to studies of sources where temporally tracing specific spectral features sensitivity, and spectral resolution is of higher significance than spatial fidelity.

Extended targets↗

Algorithmic Detection of Elemental Biosignatures

Machine learning models that classify a sample as indicative or non-indicative of life could play an important role in life-detection missions. Their predictions result from agnostic algorithms and thereby add redundancy to judgements resulting from human expertise. Additionally, their important features can reveal the most informative measurements within the operational constraints of a life-detection mission. The Ladder of Life Detection (Neveu 2018) identifies the need for an understanding of how combinations of multiple biosignatures affect overall confidence. The present work provides a starting point to answer this need, and future work will expand the data types to obtain even more predictive combinations of features. Elemental abundance was chosen as a starting set of features due to its availability in diverse sample types, which are needed to train a generalizable model. A standardized dataset was collected, including 35 non-indicative, e.g., lunar rock, basalt; 19 indicative mixed, e.g., seawater, agricultural soil; 46 indicative non-alive, e.g., coal, chalk; and 10 indicative alive, e.g., biofilm, bacteria. This dataset could be valuable for complementary biosignature research. The samples were standardized to the same limit of detection of a simulated mission scenario. Four classification models were used: k-nearest neighbors (KNN), logistic regression (LR), linear support vector machines (SVM), and Gaussian naïve Bayes (GNB). To obtain feature importances, KNN was run on three principal components of the training data and LR and SVM were run with L1 and L2 regularization. The performances and feature importances of the six model variants on 40:60 train to validation ratios were assessed with Monte Carlo simulations. ROC AUC and mean accuracy scores ranged between 82% - 94%, with sensitivity greater than specificity. For indicative of life predictors, all models had C and Ca as strong and Cl as medium; a majority of models had N, K, and P as medium. For non-indicative of life predictors, all models had Si as strong, and a majority of models had Mg, Al, and Ti as medium. Varied elements were Fe (slightly non-indicative), H (slightly indicative), O (widely varied), Na, Mn, and S. These results serve as a proof of concept and suggest important elemental signals beyond merely the CHNOPS of Earth-based life.

Algorithmic↗

Subseasonal-to-Seasonal Hindcast Skill Assessment of Ridging Events Related to Drought Over the Western United States

Persistent atmospheric ridging events centered near the western United States are associated with widespread precipitation deficits and meteorological drought. Due to the relatively low skill of- dynamical models in forecasting precipitation on subseasonal‐to‐seasonal (S2S) time scales across this region, forecasts of ridging are explored in this study as a potential bridge for early warning drought prediction. To assess skill, we evaluate deterministic and probabilistic S2S hindcasts (out to 6 week lead time) of ridging events and geopotential height anomalies over the western United States in five ensemble hindcast systems. Prediction skill for ridging events is shown to be highly variable across models. For some models, longer‐time‐averaged patterns of geopotential height anomalies across the first 6 weeks can be skillfully simulated, when evaluated probabilistically against climatology. The most skillful models show modest skill in forecasting above normal ridging occurrences at lead times of Weeks 3–4 and Weeks 5–6,with some sensitivity to the specific ridge location and method for determining skill. Using the European Centre for Medium‐Range Weather Forecasts (ECMWF) model as a case study, longer lead time forecast busts are shown to often occur under extended periods of highly active La Nina‐like tropical convection. Model errors at simulating these tropical convection features may have a disproportionately large impact and degrade downstream forecasts over the western United States. Despite the documented model shortcomings, our results highlight an opportunity to target skillful ridging forecasts from dynamical models for improving early warning drought forecasting at S2S lead times.

S2S↗

Learning from Past Missions for Today’s Case Studies

As interest in small spacecraft and its community continue to grow, the extensive selection of subsystem parts and service providers can present as many opportunities as unique challenges for mission design and implementation. These challenges often include inadequate trade studies, missing lessons learned, and unknown solutions to common pitfalls. Trade studies frequently fall short if products and services ultimately do not meet customer expectations, especially if the actual performance of a particular service or technology is not shared with others seeking similar products or services. It is difficult to quantify the viability and robustness of desired products and services, truly understand what solutions exist, and account for unique failures from previous SmallSat missions when experiences are not shared and captured. This noted, one reason for the lack of information as input for trade studies is that it is problematic to capture and disseminate the relevant lessons learned, experienced anomalies, and programmatic issues in both the laboratory and on-orbit setting, as these types of information can be extremely sensitive and are specific to each unique mission. Often, they are not made publicly available. The adoption and use of existing tools and databases, as well as contributions toward and sharing of information available in literature can help distribute useful information for future SmallSat missions to help avoid these common pitfalls. This paper will provide the required framework for current and future SmallSat mission implementation by providing best practices and identifying helpful resources to assist with subsystem parts and services as part of trade study selections.

Bruce Yost↗

Acoustic Sensor Network for Planetary Exploration

This paper investigates the concept of an acoustic sensor network that can monitor a variety of geophysical processes occurring on other planetary bodies. In many cases sound is naturally omnidirectional and travels at known speeds which depend on the composition and density of the atmosphere. The differences in the time of flight of signals received by a distributed microphone network can be used to locate the source of the sound. We suggest this property is ideal for mobile planetary robots and can be used to expand the exploration envelope considerably by directing camera pointing or rover path planning thus extending beyond line-of-sight exploration. Acoustic signatures have been used in a variety of fields (e.g., sonar, heavy machinery) to identify and catalog sounds associated with a specific vessels and malfunctioning machinery. Our ears have cataloged hundreds of sounds and we continuously use these sounds both consciously and subconsciously to extract information about our surroundings. This paper investigates the use acoustic measurements on other planetary bodies that could be used to characterize specific environmental parameters such as rain droplet size, wind speed, thunder, or dust devil vortex diameter. The paper identified other important sound sources that are thought to occur on other bodies in our solar system include; booming or singing dunes, waves, rivers, streams, fluidfalls, geysers, hurricanes, tornados, ice flow, volcanoes, planetary quakes, avalanche, rock slides and ice cracking. In addition, this paper focused on issues associated with the development of appropriate sensors for the network including the specification of the sensitivity, frequency response, and directional response of each of the microphones in the network in order to aid in localization of sound sources. We also presented our initial development of the transducers for potential mission targets including Mars and Titan and investigated the use of signal processing techniques including windowing, time frequency plots and correlation techniques to resolve phase differences between sensors in the network to aid in localization. We also identified additional benefits of these sensor networks in that they could used as engineering sensors to diagnose mechanical malfunctions on a rover or lander actuators or mechanisms. We also noted that they could also enhance public outreach by adding sound to videos.

Malaska, Mike↗

Learning from Past Missions for Today’s Case Studies

As the small spacecraft industry continues to grow, the extensive selection of subsystem parts and service providers can present unique challenges in mission implementation. These challenges include inadequate trade studies, missing lessons learned, and unknown solutions to common pitfalls. Trade studies frequently fall short because products and services ultimately do not meet customer expectations; the actual outcomes of a particular service or technology are not always shared with others seeking similar practices. It is difficult to: quantify the viability and robustness of the desired products and services, truly understand what solutions exist, and account for unique failures from previous smallsat missions. One reason for the lack of information as input for trade studies is that it is problematic to capture and disseminate the relevant lessons learned, experienced anomalies, and programmatic issues in both the laboratory and on-orbit setting as these types of information can be extremely sensitive and are specific to each unique mission. Therefore, they are not always made publicly available. The utilization and sharing of existing tools, databases, and literature can help distribute useful information for future smallsat missions to hopefully avoid these common pitfalls. This paper will provide the required framework for current and future smallsat mission implementation by providing best practices and identifying helpful resources to assist with subsystem parts and services trade study selection.

Small Spacecraft↗

Oculometric Biomarkers of Visuomotor Deficits in Clinically Asymptomatic Patients With Systemic Lupus Erythematosus Undergoing Long-Term Hydroxychloroquine Treatment

Introduction: This study examines a set of oculomotor measurements, or “oculometric” biomarkers, as potential early indicators of visual and visuomotor deficits due to retinal toxicity in asymptomatic Systemic Lupus Erythematosus (SLE) patients on long-term hydroxychloroquine (HCQ) treatment. The aim is to identify subclinical functional impairments that are otherwise undetectable by standard clinical tests and to link them to structural retinal changes. Methods: We measured oculomotor responses in a cohort of SLE patients on chronic HCQ therapy using a previously established behavioral task and analysis technique. We also examined the relationship between oculometrics, OCT measures of retinal thickness, and standard clinical perimetry measures of visual function in our patient group using Bivariate Pearson Correlation and a Linear Mixed-Effects Model (LMM). Results: Significant visual and visuomotor deficits were found in 12 asymptomatic SLE patients on long-term HCQ therapy compared to a cohort of 17 age-matched healthy controls. Notably, six oculometrics were significantly different. The median initial pursuit acceleration was 22%, steady-state pursuit gain 16%, proportion smooth 7%, and target speed responsiveness 31% lower, while catch-up saccade amplitude was 46% and fixation error 46% larger. Excluding the two patients with diagnosed mild toxicity, four oculometrics, all but fixation error and proportion smooth, remained significantly impaired compared to controls. Across our population of 12 patients (24 retinae), we found that pursuit latency, initial acceleration, steady-state gain, and fixation error were linearly related to retinal thickness even when age was accounted for, while standard measures of clinical function (Mean Deviation and Pattern Standard Deviation) were not. Discussion: Our data show that specific oculometrics are sensitive early biomarkers of functional deficits in SLE patients on HCQ that could be harnessed to assist in the early detection of HCQ-induced retinal toxicity and other visual pathologies, potentially providing early diagnostic value beyond standard visual field and OCT evaluations.

eye movements↗

Modeling ozone episodes in the Baltimore-Washington region

Surface ozone (O3) concentrations in excess of the National Ambient Air Quality Standard (NAAQS) continue to occur in metropolitan areas in the United States despite efforts to control emissions of O3 precursors. Future O3 control strategies will be based on results from modeling efforts that have just begun in many areas. Two initial questions that arise are model sensitivity to domain-specific conditions and the selection of episodes for model evaluation and control strategy development. For the Baltimore-Washington region (B-W), the presence of the Chesapeake Bay introduces a number of issues relevant to model sensitivity. In this paper, the specific questions of the determination of model volume (mixing height) for the Urban Airshed Model (UAM) is discussed and various alternative methods compared. For the latter question, several analytic approaches, Cluster Analysis and classification and Regression Tree (CART) analysis are undertaken to determine meteorological conditions associated with severe O3 events in the B-W domain.

Ryan, William F.↗

Photofragmentation-laser induced fluorescence - A new method for detecting atmospheric trace gases

A new method for the in situ detection of nonfluorescing molecular species is proposed: photofragmentation-laser induced fluorescence (PF-LIF). In this approach, the species to be detected is first laser photolyzed at a wavelength lambda (1), producing one or more vibrationally excited photofragments. Before vibrational relaxation occurs, one of these photofragments is pumped into a bonding excited state by a second laser pulse centered at wavelength lambda (2). Fluorescence is sampled at a wavelength lambda (3), where lambda (3) is less then lambda (2) and lambda (1). This pumping configuration thus permits massive discrimination against Rayleigh and Raman scattering as well as white noise fluorescence from the laser wavelengths lambda (1) and lambda (2). The technique should be both highly sensitive and selective for numerous atmospheric trace gases. Specific sampling schemes for detecting NO2, NO3, and HNO2 are proposed. Various noise sources and chemical interferences are discussed. Specific calculations that estimate the sensitivity of the PF-LIF system for detecting NO2, NO3, and HNO2 are given.

Rodgers, M. O.↗

Investigation of Benchmark $k$ eff Sensitivity and Uncertainty for 239 Pu fission in Specific Energy Ranges

Nuclear data at intermediate energies (from 1 to 100s of keV) are evaluated based on scarce differential data and theory unable to capture physics’ expected structure. There is also a lack of integral data. This is a known deficiency and is challenging to address. Calculated effective multiplication factor, k eff , values for intermediate energy experiments are ~25× further from experiment than for fast energies and are often well outside the experimental uncertainties. The goal of the PARADIGM (PARallel Approach of Differential and InteGral Measurements) project is to significantly re duce the uncertainties of intermediate energy nuclear data for 239 Pu. To this end, PARADIGM simultaneously optimizes experiments at both the Los Alamos Neutron Science Center (LANSCE) and National Criticality Experiments Research Center (NCERC). The combined set of data will inform new intermediate-energy nuclear data. By execution of differential and integral experiments, establishment of new theory, and undertaking nuclear data evaluation in parallel, the timeline to deliver improved nuclear data to users will be reduced significantly that is to three years. For the PARADIGM project, it was decided to optimize an integral experiment for two neutron energy ranges, within the full intermediate energy range. The low energy range goes from 1 to 30 keV, while the higher energy range goes from 30 to 600 keV. This work focuses on nuclear data sensitivities and uncertainties for 239 Pu fission for existing experiments in the International Criticality Safety Benchmark Evaluation Project (ICSBEP). When designing new experiments, it is important to understand what benchmarks currently exist. For a more traditional experiment design (in which a specific application model(s) exists), comparisons would be made between the application model(s) and existing benchmarks. For PARADIGM, there is no specific application model, but instead the specific nuclear data reaction and energy ranges of interest can be explored for existing benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗