Search NASA⌕ Search

SEARCH · Search NASA

Results for “Silicon Tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

In-pixel integration of signal processing and AI/ML based data filtering for particle tracking detectors

We present the first physical realization of in-pixel signal processing with integrated AI-based data filtering for particle tracking detectors. Building on prior work that demonstrated a physics-motivated edge-AI algorithm suitable for ASIC implementation, this work marks a significant milestone toward intelligent silicon trackers. Our prototype readout chip performs real-time data reduction at the sensor level while meeting stringent requirements on power, area, and latency. The chip is taped-out in 28nm TSMC CMOS bulk process, which has been shown to have sufficient radiation hardness for particle experiments. This development represents a key step toward enabling fully on-detector edge AI, with broad implications for data throughput and discovery potential in high-rate, high-radiation environments such as the High-Luminosity LHC.

Parpillon, Benjamin [Fermilab; Illinois U., Chicag↗

Performance of the Particle-Identification Silicon-Telescope Array coupled with the VAMOS++ magnetic spectrometer

The Particle-Identification Silicon-Telescope Array (PISTA) is a new detection system designed for high-resolution studies of fission process induced by multi-nucleon transfer in inverse kinematics. It is specifically optimized for experiments with the VAMOS++ magnetic spectrometer at GANIL (Grand Accélérateur National d’Ions Lourds). The array comprises eight trapezoidal ΔE-E silicon telescopes arranged in a lamp shade configuration. Each telescope integrates two single-sided stripped silicon detectors, enabling target-like recoil identification, energy loss measurements, and trajectory reconstruction. Positioned in close proximity to the target, PISTA’s compact geometry achieves high-efficiency tracking of target-like recoils produced in multi-nucleon transfer reactions at Coulomb barrier energies. The spatial segmentation of the array allows precise determination of the mass and charge of the target-like nucleus, and excitation energy of fissioning systems. This work presents the particle identification and excitation energy reconstruction performances for the interactions of 238 U beam with 12 C target. An excitation energy resolution of 800 keV (FWHM) was determined together with mass resolution of 1.1% (FWHM). The combination of PISTA and VAMOS++ magnetic spectrometer enables unprecedented investigations of the fission process as a function of the excitation energy of the fissioning nucleus, particularly for exotic systems produced in transfer-induced reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development, construction and tests of the Mu2e electromagnetic calorimeter mechanical structures

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the charged lepton flavour violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of the existence of physics beyond the standard model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. In particular, the calorimeter provides excellent electron identification, a fast calorimetric online trigger, and complementary information to aid pattern recognition and track reconstruction. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total expected ionizing dose of 12 krad and a neutron fluence of 5 × 10$^{10}$ n/cm$^{2}$ @ 1 MeV$_{eq}$ (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on scintillating materials, sensors, electronics and on the design of the detector mechanical structures and material choice. The support structure of each 674 crystal matrix is composed of an aluminum hollow ring and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and front-end electronics for the readout of each crystal are inserted in a machined copper holder and make a unique mechanical unit. The resulting 674 mechanical units are supported by a machined plate of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics are hosted in aluminum custom crates positioned on the external lateral surface of the disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system. In this paper we report on the calorimeter mechanical structure design, the mechanical and thermal simulations that have determined the design technological choices, and the status of component production, quality assurance tests and plans for assembly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced adhesion by high energy bombardment

Films (12) of gold, copper, silicon nitride, or other materials are firmly bonded to insulator substrates (12) such as silica, a ferrite, or Teflon (polytetrafluorethylene) by irradiating the interface with high energy ions. Apparently, track forming processes in the electronic stopping region cause intermixing in a thin surface layer resulting in improved adhesion without excessive doping. Thick layers can be bonded by depositing or doping the interfacial surfaces with fissionable elements or alpha emitters.

Griffith, Joseph E.↗

The CLAS12 Silicon Vertex Tracker

Silicon Vertex Tracker (SVT) has been designed for the CLAS12 spectrometer using single-sided microstrip sensors fabricated by Hamamatsu Photonics. The sensors have a graded angle design to minimize dead areas and a readout pitch of 156 um, with intermediate strips. Each double-sided SVT module hosts three daisy-chained sensors on each side with a full strip length of 33 cm. There are 512 channels per module, read out by four Fermilab Silicon Strip Readout (FSSR2) chips, featuring data-driven architecture, mounted on a rigid–flex hybrid board. The modules are assembled in a barrel configuration using a unique cantilevered geometry to minimize the amount of material in the tracking volume. This paper is focused on the design, qualification of the performance, and experience in operating and commissioning the tracker during the first year of the data taking.

47 OTHER INSTRUMENTATION↗

Comparison of Model Calculations of Biological Damage from Exposure to Heavy Ions with Measurements

The space environment consists of a varying field of radiation particles including high-energy ions, with spacecraft shielding material providing the major protection to astronauts from harmful exposure. Unlike low-LET gamma or X rays, the presence of shielding does not always reduce the radiation risks for energetic charged-particle exposure. Dose delivered by the charged particle increases sharply at the Bragg peak. However, the Bragg curve does not necessarily represent the biological damage along the particle path since biological effects are influenced by the track structures of both primary and secondary particles. Therefore, the ''biological Bragg curve'' is dependent on the energy and the type of the primary particle and may vary for different biological end points. Measurements of the induction of micronuclei (MN) have made across the Bragg curve in human fibroblasts exposed to energetic silicon and iron ions in vitro at two different energies, 300 MeV/nucleon and 1 GeV/nucleon. Although the data did not reveal an increased yield of MN at the location of the Bragg peak, the increased inhibition of cell progression, which is related to cell death, was found at the Bragg peak location. These results are compared to the calculations of biological damage using a stochastic Monte-Carlo track structure model, Galactic Cosmic Ray Event-based Risk Model (GERM) code (Cucinotta, et al., 2011). The GERM code estimates the basic physical properties along the passage of heavy ions in tissue and shielding materials, by which the experimental set-up can be interpreted. The code can also be used to describe the biophysical events of interest in radiobiology, cancer therapy, and space exploration. The calculation has shown that the severely damaged cells at the Bragg peak are more likely to go through reproductive death, the so called "overkill".

Kim, Myung-Hee Y.↗

Radiation Measured during ISS-Expedition 13 with Different Dosimeters

Radiation in low Earth orbit (LEO) is mainly composed of Galactic Cosmic Rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). The biological impact of space radiation to astronauts depends strongly on the particles linear energy transfer (LET) and is dominated by high LET radiation. It is important to measure the LET spectrum for the space radiation field and to investigate the influence of radiation on astronauts. At present, the preferred active dosimeters sensitive to all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors in various configurations; the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. The TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation exposure for the ISS mission Expedition 13 (ISS-12S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the space mission with different dosimeters. This paper introduces the operational principles for the dosimeters, describes the method to combine the results measured by TLDs/OSLDs and CR-39 PNTDs, and presents the LET spectra and the radiation quantities measured. Keywords: space radiation; cosmic rays; active and passive dosimeters; LET spectra

Zhou, D.↗

Application of New Technology to Future Celestial Trackers

New developments in image sensors and optical materials have opened the door to dramatic mass and power reductions in celestial tracker designs. The rapid development of active pixel sensors (APS) has provided a new detector choice offering high on-chip integration of support circuitry at reduced power consumption. Silicon-Carbide (Si-C) optics are one of the new developments in low-mass optical components. We describe the celestial tracker needs of an Autonomous Feature and Star Tracking (AFAST) system designed for autonomous spacecraft control. Details of a low mass celestial tracker, based on a low power APS array and optimized for an AFAST system, are discussed.

active↗

Design and performance of silicon strip sensors with slim edges for HPS experiment

In this paper, we report on design and performance of new strip sensors for the Heavy Photon Search (HPS) experiment. The sensors feature a slim edge implementation using the Scribe–Cleave–Passivate (SCP) method. The slim edge design has allowed the introduction of a new layer closer to the target, which increased the tracking acceptance and vertex precision, improving physics reach of the experiment. We describe the production, testing, and operational experience with the new sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A space qualified thermal imaging system using a Pt Si detector array

EDO Corporation, Barnes Engineering Division designed and constructed a high resolution thermal imaging system on contract to Lockheed for use in the SDI Star Lab. This employs a Pt Si CCD array which is sensitive in the spectral range of 3 to 5 microns. Star Lab will be flown in the Shuttle bay and consists basically of a large, reflecting, tracking telescope with associated sensors and electronics. The thermal imaging system is designed to operate in the focal plane of this telescope. The configuration of the system is illustrated. The telescope provides a collimated beam output which is focussed onto the detector array by a silicon objective lens. The detector array subtends a field of view of 1.6 degrees x 1.22 degrees. A beam switching mirror permits bypassing the large telescope to give a field of 4 degrees x 3 degrees. Two 8 position filter wheels are provided, and background radiation is minimized by Narcissus mirrors. The detector is cooled with a Joule-Thompson cryostat fed from a high pressure supply tank. This was selected instead of a more convenient closed-cycle system because of concern with vibration. The latter may couple into the extremely critical Starlab tracking telescope. The electronics produce a digitized video signal for recording. Offset and responsivity correction factors are stored for all pixels and these corrections are made to the digitized output in real time.

Astheimer, Robert W.↗

Pulsed power to control growth of silicon nanoparticles in low temperature flowing plasmas

Low-temperature plasmas have seen increasing use for synthesizing high-quality, mono-disperse nanoparticles (NPs). Recent work has highlighted that an important process in NP growth in plasmas is particle trapping—small, negatively charged nanoparticles become trapped by the positive electrostatic potential in the plasma, even if only momentarily charged. In this article, results are discussed from a computational investigation into how pulsing the power applied to an inductively coupled plasma (ICP) reactor may be used for controlling the size of NPs synthesized in the plasma. The model system is an ICP at 1 Torr to grow silicon NPs from an Ar/SiH 4 gas mixture. This system was simulated using a two-dimensional plasma hydrodynamics model coupled to a three-dimensional kinetic NP growth and trajectory tracking model. The effects of pulse frequency and pulse duty cycle are discussed. We identified separate regimes of pulsing where particles become trapped for one pulsed cycle, a few cycles, and many cycles—each having noticeable effects on particle size distributions. For the same average power, pulsing can produce a stronger trapping potential for particles when compared to continuous wave power, potentially increasing particle mono-dispersity. Pulsing may also offer a larger degree of control over particle size for the same average power. Experimental confirmation of predicted trends is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The CLAS12 Micromegas Vertex Tracker

The Micromegas Vertex Tracker was designed to improve upon the tracking capabilities of the baseline design of the CLAS12 spectrometer in Hall~B at Jefferson Laboratory. A Barrel Micromegas Tracker made with six concentric cylinders, each made of three 120$^\circ$-sector tiles, surrounds the Silicon Vertex Tracker, and a Forward Micromegas Tracker composed of 6 disks is placed 30~cm downstream of the liquid-hydrogen target. Both trackers sit in a 5~T solenoid magnetic field. All Micromegas elements are based on resistive technology to withstand luminosities up to $10^{35}$~cm$^{-2}$s$^{-1}$, as well as on bulk technology to enforce gain uniformity and mechanical robustness. Due to the high magnetic field, dedicated electronics have been designed and displaced $\sim$2~m away from the detectors. The electronics readout is based on the DREAM ASICs that allow sustained operation up to 20~kHz trigger rate at the maximum luminosity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fail safe laser activated switch used as an emergency control link at the Langley Vortex Research Facility

A fail safe light activated switch was used as an emergency control link at the Langley Vortex Research Facility. In this facility aircraft models were towed through a still air test chamber by a gasoline powered vehicle which was launched from one end of a 427-meter track and attained velocities to 31 m/sec in the test chamber. A 5 mW HeNe laser with a mechanical copper provided a connecting link with the moving tow vehicle on which a silicon photodiode receiver with a specially designed amplifier provided a fail safe switching action. This system provided an emergency means of stopping the vehicle by turning off the laser to interrupt the power to the vehicle ignition and brake release systems.

Kassel, P. C., Jr.↗

Gripping Mechanisms for Microgravity and Extreme Terrain and Vertical Climbing Micro Ground Vehicle

Asteroids and comets may provide insight into the origins of our solar system and the precursors to life on our planet. Near Earth objects offer an accessible target of opportunity, but are small and lack the gravity necessary for conventional wheeled travel. Therefore, it is necessary to develop alternative methods for maneuvering in these environments. This project researched and developed a method for gripping rock surfaces. Work has been completed on the design and prototyping of several possible hooked gripping mechanisms. Future work includes quantitative testing, downselection to a final design, and attachment to the robotic platform, Lemur IIb. A second project focuses on the development of a 100g, crash-proof robot capable of climbing vertical surfaces using a novel silicone adhesive. Capable of carrying video/audio payloads the robot may serve as a surveillance tool for the Department of Defense or as a method of pre-flight spacecraft inspections. A specialized track was developed to provide the specific loading conditions necessary for proper engagement of the adhesive. Both of these projects rely heavily on the shape deposition manufacturing process, being researched at JPL, and 3D printing.

robotic locomotion↗

Evaluation of HPK n + - p planar pixel sensors for the CMS Phase-2 upgrade

To cope with the challenging environment of the planned high luminosity upgrade of the Large Hadron Collider (HL-LHC), scheduled to start operation in 2029, CMS will replace its entire tracking system. The requirements for the tracker are largely determined by the long operation time of 10 years with an instantaneous peak luminosity of up to 7.5 × 10 34 cm –2 s –1 in the ultimate performance scenario. Depending on the radial distance from the interaction point, the silicon sensors will receive a particle fluence corresponding to a non-ionizing energy loss of up to $\Phi_{\text {eq}}$ = 3.5 × 10 16 cm –2 . Here this paper focuses on planar pixel sensor design and qualification up to a fluence of $\Phi_{\text {eq}}$ = 1.4 × 10 16 cm –2 . For the development of appropriate planar pixel sensors an R&D program was initiated, which includes $n^+ -p$ sensors on 150 mm (6”) wafers with an active thickness of 150 μm with pixel sizes of 100 × 25 μm 2 and 50 × 50 μm 2 manufactured by Hamamatsu. Single chip modules with ROC4Sens and RD53A readout chips were made. Irradiation with protons and neutrons, as well was an extensive test beam campaign at DESY were carried out. This paper presents the investigation of various assemblies mainly with ROC4Sens readout chips. It demonstrates that multiple designs fulfill the requirements in terms of breakdown voltage, leakage current and efficiency. The single point resolution for 50 × 50 μm 2 pixels is measured as 4.0 μm for non-irradiated samples, and 6.3 μm after irradiation to $\Phi_{\text {eq}}$ = 7.2 × 10 15 cm –2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Emitter Formation Dynamics and Probing of Radiation-Induced Atomic Disorder in Silicon

Near-infrared color centers in silicon are emerging candidates for on-chip integrated quantum emitters, optical-access quantum memories, and sensing. We access ensemble G-color-center formation dynamics and radiation-induced atomic disorder in silicon for a series of megaelectronvolt proton-flux conditions. The photoluminescence results reveal that the G centers are formed more efficiently by pulsed-proton irradiation than by continuous-wave proton irradiation. The enhanced transient excitations and dynamic annealing within nanoseconds allows optimization of the ratio of G-center formation to nonradiative defect accumulation. The G centers preserve narrow line widths of about 0.1 nm when they are generated by moderate pulsed-proton fluences, while the line width broadens significantly as the pulsed-proton fluence increases. This implies vacancy or interstitial clustering by overlapping collision cascades. The tracking of G-center properties for a series of irradiation conditions enables sensitive probing of atomic disorder, serving as a complementary analytical method for sensing damage accumulation. Aided by ab initio electronic structure calculations, we provide insight into the atomic disorder induced inhomogeneous broadening by introducing vacancies, silicon interstitials, and oriented strain fields in the vicinity of a G center. A vacancy leads to a tensile strain and can result in either a red shift or a blue shift of the G-center emission, depending on its position relative to the G center. Meanwhile, Si interstitials lead to compressive strain, which results in a monotonic red shift. In conclusion, high-flux and tunable ion pulses enable the exploration of the fundamental dynamics of radiation-induced defects as well as methods for the optimization of G-center formation and qubit synthesis for quantum information processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The CMS Outer Tracker for the High Luminosity LHC

The High Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of 3000 - 4000 fb -1 in its lifetime with peak instantaneous luminosities reaching about 5 - 7.5×10 34 cm -2 s -1 . During the Long Shutdown 3 period, several components of the CMS detector will undergo major changes, called Phase-2 upgrades, to be able to operate in the challenging environment of the HL-LHC, including the replacement of the entire silicon tracker. The Phase-2 Outer Tracker (OT) will have high radiation tolerance, higher granularity, and the capability to handle higher data rates. Another key feature of the OT will be to provide tracking information to the Level-1 trigger, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made of modules that have two closely spaced sensors read out by the same electronics, which can correlate hits in the two sensors creating short track segments called ”stubs”. The stubs will be used for tracking at 40 MHz. In this contribution, the design of the CMS Phase-2 OT, the technological choices, and highlights of research and development activities are reported.

Ravera, Fabio↗

Silicon solar photovoltaic power stations

Modular design of components and arrays, cost estimates for modules and support structures, and cost/performance analysis of a central solar photovoltaic power plant are discussed. Costs of collector/reflector arrays are judged the dominant element in the total capital investment. High-concentration solar tracking arrays are recommended as the most economic means for producing solar photovoltaic energy when solar cells costs are high ($500 per kW generated). Capital costs for power conditioning subsystem components are itemized and system busbar energy costs are discussed at length.

Chowaniec, C. R.↗