Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single photons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Ruby laser induced emission from NO2

Two different types of emission from excited NO2 were observed using pulsed ruby laser light at 6943 A. The first type of fluorescence was seen in the near IR and results from the single photon excitation of NO2 from the ground 2-A1 state. By observing the emission as a function of time an unexpected behavior was observed in the near IR and could be explained by a consecutive deactivation mechanism, wherein a secondary species is preferentially detected. A second type of emission recently observed in the blue spectral region is weaker and is due to a multiphoton process. The intensity of the blue emission is a function of the cube of the laser intensity at low pressures and approaches the square at high pressures. This variation is attributed to simultaneous deactivation of the excited NO2 intermediate by collision (square) and by anti-Stokes Raman scattering off of the excited NO2 (cube).

Hakala, D. F.↗

The High Resolution Imaging Instrument for HEAO-B

The High Resolution Imaging Instrument for the HEAO-B X-ray Telescope satellite is designed to reproduce images of celestial X-ray sources in the range of 0.2 to 4.0 keV. It provides both imaging and temporal data. The basic detector is a two-stage microchannel plate with a crossed-grid charge detector. Preamplifiers, detector bias supplies, and some processing circuits are colocated with the detector. The remaining electronic circuits are located in a remote central electronic assembly. The processing system is designed for single-photon processing. The imaging data rate is limited to 100 data points per second. Non-imaging total-field count rate is acquired with a maximum dead time of 14 microseconds per event.

Kubierschky, K.↗

Overview of laser applications to chemistry

The discussion is in three parts. First, laser spectroscopy is discussed with consideration given to single-photon and multiphoton processes. Second, attention is given to the use of lasers in studying molecular interactions and reaction dynamics. Finally, the paper discusses the relationship between chemistry and laser development.

George, T. F.↗

A low-energy gamma-ray imaging detector

We describe a hard-X-ray/soft-gamma-ray imaging detector, incorporating a microchannel-plate (MCP) electron multiplier for possible use in future telescopes. In contrast to previous attempts using MCP's this approach promises to achieve high quantum detection efficiencies in addition to high spatial and temporal resolution. Preliminary results indicate not only the capability of simultaneous imaging and single-photon counting, but also coarse energy resolution.

Yin, L. I.↗

New position-sensitive hard X-ray spectrometer

The design and features of a new prototype Lixiscope (Low intensity X-ray imaging scope) is described. It is shown that in addition to good spatial and temporal resolution in the 20 keV to 200 keV region, it is capable of single-photon counting, imaging as well as good energy resolution. It is concluded that the device is well suited for future low-flux applications in astronomy, medicine, and industry.

Yin, L. I.↗

Improved Lixiscope

Improved lixiscope utilizes fast-decay scintillators and multiple or curved microchannels to achieve high energy and spatial resolution as well as single-photon counting. New unit, with higher energy resolution, is intended for X-ray astronomy, although it could be applied terrestrially wherever a sensitive portable radiation spectrometer is required for 20-to-200-keV range.

Yin, L. I.↗

Soft X-ray and XUV imaging with a charge-coupled device /CCD/-based detector

A soft X-ray/XUV imaging camera which uses a thinned, back-illuminated, all-buried channel RCA CCD for radiation sensing has been built and tested. The camera is a slow-scan device which makes possible frame integration if necessary. The detection characteristics of the device have been tested over the 15-1500 eV range. The response was linear with exposure up to 0.2-0.4 erg/sq cm; saturation occurred at greater exposures. Attention is given to attempts to resolve single photons with energies of 1.5 keV.

Loter, N. G.↗

Skeletal and body composition evaluation

Research on radiation detectors for absorptiometry; analysis of errors affective single photon absorptiometry and development of instrumentation; analysis of errors affecting dual photon absorptiometry and development of instrumentation; comparison of skeletal measurements with other techniques; cooperation with NASA projects for skeletal evaluation in spaceflight (Experiment MO-78) and in laboratory studies with immobilized animals; studies of postmenopausal osteoporosis; organization of scientific meetings and workshops on absorptiometric measurement; and development of instrumentation for measurement of fluid shifts in the human body were performed. Instrumentation was developed that allows accurate and precise (2% error) measurements of mineral content in compact and trabecular bone and of the total skeleton. Instrumentation was also developed to measure fluid shifts in the extremities. Radiation exposure with those procedures is low (2-10 MREM). One hundred seventy three technical reports and one hundred and four published papers of studies from the University of Wisconsin Bone Mineral Lab are listed.

Mazess, R. B.↗

Pair production in superstrong magnetic fields

The production of electron-positron pairs by single photons in magnetic fields 10 to the twelth power G was investigated in detail for photon energies near threshold as well as for the asymptotic limit of high photon energy. The exact attenuation coefficient, which is derived and then evaluated numerically, is strongly influenced by the discrete energy states of the electron and positron. Near threshold, it exhibits a sawtooth pattern as a function of photon energy, and its value is significantly below that predicted by the asymptotic expression for the attenuation coefficient. The energy distributions of the created pair are computed numerically near threshold and analytic expressions are derived in the asymptotic limit. These results indicate that as field strength and photon energy increase, it becomes increasingly probable for the pair to divide the photon energy unequally. This effect, as well as the threshold behavior of the attenuation coefficient, could have important consequences for pulsar models.

Daugherty, J. K.↗

Early experience with a highly mobile Lageos ranging system

Two portions of the University of Texas Transportable Laser Ranging System (TLRS) are presented: the beam director and the burst mode single photon laser ranging system. The system, optimized for the Lageos target, has satellite track rates varying from approximately 1800 arcsec per sec on low targets to a few arcsec per sec on the highest. Using full aperture, approximately 3 millijoules of laser power per shot can be transmitted without exceeding the eye damage threshold, and a beam divergence of less than 30 arcsec is dictated by these parameters. Position loop response is optimized, and the instrument is capable of tracking the satellite from nearly any firm, flat position. The laser ranging system uses a multiple pulse laser, and power restrictions result in an average return of less than one photoelectron per shot. The use of a simple laser for ranging has virtually eliminated the high percentage of down time.

Silverberg, E. C.↗

Pair production in superstrong magnetic fields

The production of electron-positron pairs by single photons in magnetic fields of not less than about 10 to the 12th gauss has been investigated in detail for photon energy. The exact attenuation coefficient, which is derived and then evaluated numerically, is strongly influenced by the discrete energy states of the electron and positron. Near threshold, it exhibits a 'sawtooth' pattern as a function of photon energy and its value is significantly below that predicted by the asymptotic expression for the attenuation coefficient. The energy distributions of the created pair are computed numerically near threshold, and analytic expressions are derived in the asymptotic limit. These results indicate that as field strength and photon energy increase, it becomes increasingly probable for the pair to divide strength energy unequally. This effect, as well as the threshold behavior of the attenuation coefficient, could have important consequences to pulsar models.

Daugherty, J. K.↗

EGRET - The high energy gamma ray telescope for NASA's Gamma Ray Observatory

The EGRET high energy gamma-ray telescope under development for NASA's Gamma Ray Observatory will have an energy range of approximately 12 to 30,000 MeV, energy resolution of about 15 percent FWHM over most of that range, an effective area of about 2000 sq cm at high energies, and single photon angular accuracy of approximately 2 deg at 100 MeV, less than 0.1 deg above 5 GeV. This instrument can locate strong sources to an accuracy of about 5 arc min. The instrument utilizes a set of digital spark chambers interleaved with tantalum foils for detection and identification of gamma-ray events, and a large NaI(Tl) scintillator for energy determination. The system is triggered by a coincidence matrix using two arrays of plastic scintillation counters and a large plastic scintillator anticoincidence dome that rejects incident charged particles.

Fichtel, C. E.↗

Nondispersive X-ray spectroscopy and imaging of plasmas using a charge-coupled device

A virtual-phase charge-coupled device (CCD) was used to obtain pinhole images and X-ray spectra of laser-produced, solid target plasmas. With the CCD used in the single-photon counting mode, the spectrum in the energy range 2-10 keV was obtained without a dispersive element. Typical spectra reveal two distinct temperatures: a cold component of approximately 200 eV and a hot component of approximately 5 keV. Also, multiline spectra comprising characteristic line emission (K alpha, K beta) from a multilayer target bombarded by beta-rays were recorded using a three-phase CCD. The results demonstrate the potential of CCDs as imaging spectrometers with application in space, laboratory, and fusion-plasma research.

Marsh, K.↗

High-Resolution Thermal X-Ray Detector

Thermal pulses from single photons measured. Detector, consists of X-ray absorber, temperature sensor in absorber, and thermal link from absorber to heat sink. X-ray photon detected by measuring temperature rise immediately following absorption of photon. Thermal X-ray detector, tested successfully in prototype, in theory operates as spectrometer that provides 100 times spectral resolution of conventional to detect trace constituents in materials by X-ray fluorescence. Also used for measuring energies of energetic electrons and weak pulses of light.

Moseley, S. H.↗

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗

Photoconversion from the light-adapted to the dark-adapted state of bacteriorhodopsin

The dark and light adaptation of the bR(trans)570 (bacteriorhodopsin) and bR(cis)550 isomers is analyzed. The equilibrium between the two bR isomers in light-adapted purple membrane films is studied in terms of the wavelength of actinic light and hydration levels. Absorption spectra observed after light adaptations with red and yellow light reveal that red light is less efficient in converting bR(cis)550 to bR(trans)570 than yellow light and the amount of bR(cis)550 in a light-adapted sample increases with decreasing hydration. The rate constants of dark and light adaptation are evaluated; the rate constant of dark adaptation is independent of the hydration level and the rate constant of light adaptation increases with hydration. The acceleration of a dark adaptation by red light is investigated; the dependence of the accelerated dark adaptation on the light intensity is discussed. The action spectrum of light adaptation in a purple membrane suspension is compared with the absorption spectrum of bR(cis)550; correlation between the spectra reveals that cis-to-transconversion is due to excitation of bR(cis)550 and the mechanism of cis-to-trans conversion in film is not affected by humidity levels. It is noted that the light-driven trans-to-cis conversion is a single photon process. The branching at M410 from the all-trans into the 13-cis photocycle is examined.

Kouyama, T.↗

The AXAF CCD imaging spectrometer

The AXAF CCD Imaging Spectrometer (ACIS) is currently being defined as a possible focal plane instrument to be flown on the Advanced X-ray Astrophysics Facility (AXAF). The imaging spectrometer consists of an array of charge coupled devices (CCD's) to be placed at the focus of the AXAF mirrors. The array will provide high angular resolution (0.5 arc seconds), moderate spectral resolution (150 eV) over the energy range 0.1 to 10 keV, temporal resolution down to 60 microseconds, and single photon quantum detection efficiencies of up to 90 percent. X-ray sensitivity for a point source exceeds 10 to the -15th ergs/sq cm sec for a 10 to the 5th sec exposure. When used in conjunction with the objective gratings, the array will yield wavelength resolution of up to 200.

Garmire, G. P.↗

Effect of detector dead time on the performance of optical direct-detection communication links

Avalanche photodiodes (APDs) operating in the Geiger mode can provide a significantly improved single-photon detection sensitivity over conventional photodiodes. However, the quenching circuit required to remove the excess charge carriers after each photon event can introduce an undesirable dead time into the detection process. The effect of this detector dead time on the performance of a binary pulse-position-modulated (PPM) channel is studied by analyzing the error probability. It is shown that, when background noise is negligible, the performance of the detector with dead time is similar to that of a quantum-limited receiver. For systems with increasing background intensities, the error rate of the receiver starts to degrade rapidly with increasing dead time. The power penalty due to detector dead time is also evaluated and shown to depend critically on badkground intensity as well as dead time. Given the expected background strength in an optical channel, therefore, a constraint must be placed on the bandwidth of the receiver to limit the amount of power penalty due to detector dead time.

Chen, C.-C.↗