Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single point correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Viability of perturbative expansion for quantum field theories on neurons

Neural Network (NN) architectures that break statistical independence of parameters have been proposed as a new approach for simulating local quantum field theories (QFTs) [1]. In the infinite neuron number limit, single-layer NNs can exactly reproduce QFT results. This paper examines the viability of this architecture for perturbative calculations of local QFTs for finite neuron number N using scalar ϕ 4 theory in d Euclidean dimensions as an example. We find that the renormalized O(1/N ) corrections to two-and four-point correlators yield perturbative series which are sensitive to the UV cut-off and therefore have a weak convergence. We propose a modification to the architecture to improve this convergence and discuss constraints on the parameters of the theory and the scaling of N which allow us to extract accurate field theory results.

Sen, Srimoyee [Iowa State University, Ames, IA (Un↗

Forebody Flow Visualization on the F-18 HARV with Actuated Forebody Strakes

Off-surface smoke flow visualization and extensive pressure measurements were obtained on the forebody of the NASA F-18 High Alpha Research Vehicle equipped with actuated forebody strakes. Test points at alpha = 50 deg. were examined in which only one strake was deflected or in which both strakes were deflected differentially. The forebody pressures were integrated to obtain forebody yawing moments. Results showed that small single strake deflections can cause an undesirable yawing moment reversal. At alpha = 50 deg., this reversal was corrected by deploying both strakes at 20 deg. initially, then differentially from 20 deg. to create a yawing moment. The off-surface flow visualization showed that in the case of the small single strake deflection, the resulting forebody/strake vortex remained close to the surface and caused accelerated flow and increased suction pressures on the deflected side. When both strakes were deflected differentially, two forebody/strake vortices were present. The forebody/strake vortex from the larger deflection would lift from the surface while the other would remain close to the surface. The nearer forebody/strake vortex would cause greater flow acceleration, higher suction pressures and a yawing moment on that side of the forebody. Flow visualization provided a clear description of the strake vortices fluid mechanics.

David F Fisher↗

Pointing, Acquisition, and Tracking for the TBIRD Cubesat Mission: System Design and Pre-Flight Results

The Terabyte InfraRed Delivery (TBIRD) program will establish a communication link from a nanosatellite in low-Earth orbit to a ground station at burst rates up to 200 Gbps. The TBIRD payload is currently in the process of integrating with the 6-U CubeSat host bus and pre-flight testing has been completed. An overview of the pointing, acquisition, and tracking system for TBIRD is provided as well as a summary of results from pre-flight testing. TBIRD relies on the spacecraft bus to implement fine pointing corrections supplied by its quad sensor at a rate of 10 Hz. The measured accuracy of pointing feedback is about 10μrad RMS per axis. A custom optical assembly was designed for transmitter/receiver alignment stability which was measured to be within 25μrad two-axis through environmental testing. With TBIRD feedback in the loop, single axis pointing accuracy of the downlink is predicted to be about 30μrad RMS.

space communications↗

Root Cause Analysis of the Data Refinement Process – Medical Conditions Capability Resource Tables

The medical system for spaceflight thus far has been designed to support missions in low earth orbit (LEO). Crew capabilities are limited and heavily dependent on the team of medical support staff at Mission Control Center (MCC) to guide diagnosis and management. However, missions to the Moon and Mars will suffer from several constraints that will make this ground support focused approach to care ineffective. In order to update and modify medical system design, NASA has relied on Probabilistic Risk Assessment (PRA) modeling to mitigate medical risk through trade space analysis. Specifically, capability resource tables (CRT’s) were developed to create a dataset of resources required to manage a list of accepted medical conditions significant in exploration spaceflight. With 120 conditions, this dataset contained hundreds of capabilities and thousands of resources with tens of thousands of cells of data. Initially these tables were built in excel for high throughput during development, but ultimately had to be transferred, managed, and modified into the Evidence Library database for modeling purposes. The process of collating and reviewing the Evidence Library revealed numerous errors in the dataset that had to be corrected through iterative changes. Several error types emerged during this process and can be broken into specific classifications defined as “input”, “transcription”, “structural”, “branching”, and “information”. In reviewing these error types through the root cause analysis (RCA) approach, we were able to identify the contributors to these errors which included single data review points, changing product end goals, limited software selection, time constraints and several others. By reviewing and evaluating the underlying causes we can provide possible system improvements that can be implemented for current and future data management in PRA model inputs.

A. Anderson↗

Laser Characterization of Optically Smooth BREAD parts

The Broadband Reflector Experiment for Axion Detection is a dish antenna experiment probing the axion and dark photon parameter space in the [1 μeV, 1 eV] mass range, or [.02, 200] THz frequency range. In the pilot design for the InfraBREAD model, the dish antenna includes an optically smooth coaxial parabolic reflector to focus incoming photons in the near Infrared spectrum, created by the spontaneous photoconversion of axions and dark photons, onto a Superconducting Nanowire Single Photon Detector at the focus point of the reflector. As the pilot begins as a dark photon detector, sensitivity estimates hypothesize that it could cover unprobed parameter space in the search for the dark photon. Because of this, it is of critical importance that the reflector and SNSPD be placed at the correct points in the dish antenna, as previous work has shown that in addition to the focal spot of the photons being smeared to an area larger than the SNSPD, detection efficiency is s ensitive to shifts on the millimeter scale. In order to constrain this barrier to efficiency, the reflector had its focal spot, roughness, and length of surface waves measured by lasers in an optical bench setup. Results show the focal point diverging slightly from its theorized position in the antenna, while uncertainty in the height at which the detector should be placed was constrained to 10s of microns, the uncertainty in radial position could not be constrained to smaller than the detector given the methods used. Results for the roughness and surface wavelength show that the reflector was uniformly machined in a diamond-turning process used to fabricate optically smooth parts, as well as support a roughly 90% detection efficiency, reinforcing the sensitivity estimates presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Density functional theory study of the interaction of vinyl radical, ethyne, and ethene with benzene, aimed to define an affordable computational level to investigate stability trends in large van der Waals complexes

Our purpose is to identify a computational level sufficiently dependable and affordable to assess trends in the interaction of a variety of radical or closed shell unsaturated hydro-carbons A adsorbed on soot platelet models B. These systems, of environmental interest, would unavoidably have rather large sizes, thus prompting to explore in this paper the performances of relatively low-level computational methods and compare them with higher-level reference results. To this end, the interaction of three complexes between non-polar species, vinyl radical, ethyne, or ethene (A) with benzene (B) is studied, since these species, involved themselves in growth processes of polycyclic aromatic hydrocarbons (PAHs) and soot particles, are small enough to allow high-level reference calculations of the interaction energy ΔE{sub AB}. Counterpoise-corrected interaction energies ΔE{sub AB} are used at all stages. (1) Density Functional Theory (DFT) unconstrained optimizations of the A−B complexes are carried out, using the B3LYP-D, ωB97X-D, and M06-2X functionals, with six basis sets: 6-31G(d), 6-311 (2d,p), and 6-311++G(3df,3pd); aug-cc-pVDZ and aug-cc-pVTZ; N07T. (2) Then, unconstrained optimizations by Møller-Plesset second order Perturbation Theory (MP2), with each basis set, allow subsequent single point Coupled Cluster Singles Doubles and perturbative estimate of the Triples energy computations with the same basis sets [CCSD(T)//MP2]. (3) Based on an additivity assumption of (i) the estimated MP2 energy at the complete basis set limit [E{sub MP2/CBS}] and (ii) the higher-order correlation energy effects in passing from MP2 to CCSD(T) at the aug-cc-pVTZ basis set, ΔE{sub CC-MP}, a CCSD(T)/CBS estimate is obtained and taken as a computational energy reference. At DFT, variations in ΔE{sub AB} with basis set are not large for the title molecules, and the three functionals perform rather satisfactorily even with rather small basis sets [6-31G(d) and N07T], exhibiting deviation from the computational reference of less than 1 kcal mol{sup −1}. The zero-point vibrational energy corrected estimates Δ(E{sub AB}+ZPE), obtained with the three functionals and the 6-31G(d) and N07T basis sets, are compared with experimental D{sub 0} measures, when available. In particular, this comparison is finally extended to the naphthalene and coronene dimers and to three π−π associations of different PAHs (R, made by 10, 16, or 24 C atoms) and P (80 C atoms)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Attosecond transient absorption instrumentation for thin film materials: Phase transitions, heat dissipation, signal stabilization, timing correction, and rapid sample rotation

We present an extreme ultraviolet (XUV) transient absorption apparatus tailored to attosecond and femtosecond measurements on bulk solid-state thin-film samples, specifically when the sample dynamics are sensitive to heating effects. The setup combines methodology for stabilizing sub-femtosecond time-resolution measurements over 48 h and techniques for mitigating heat buildup in temperature-dependent samples. Single-point beam stabilization in pump and probe arms and periodic time-zero reference measurements are described for accurate timing and stabilization. A hollow-shaft motor configuration for rapid sample rotation, raster scanning capability, and additional diagnostics are described for heat mitigation. Heat transfer simulations performed using a finite element analysis allow comparison of sample rotation and traditional raster scanning techniques for 100 Hz pulsed laser measurements on vanadium dioxide, a material that undergoes an insulator-to-metal transition at a modest temperature of 340 K. Experimental results are presented confirming that the vanadium dioxide (VO 2 ) sample cannot cool below its phase transition temperature between laser pulses without rapid rotation, in agreement with the simulations. The findings indicate the stringent conditions required to perform rigorous broadband XUV time-resolved absorption measurements on bulk solid-state samples, particularly those with temperature sensitivity, and elucidate a clear methodology to perform them.

47 OTHER INSTRUMENTATION↗

Lepton asymmetry rate from quantum field theory: NLO in the hierarchical limit

The rates for generating a matter-antimatter asymmetry in extensions of the Standard Model (SM) containing right-handed neutrinos are the most interesting and least trivial co\-efficients in the rate equations for baryogenesis through thermal leptogenesis. We obtain a relation of these rates to finite-temperature real-time correlation functions, similar to the Kubo formulas for transport coefficients. Then we consider the case of hierarchical masses for the sterile neutrinos. At leading order in their Yukawa couplings we find a simple master formula which relates the rates to a single finite temperature three-point spectral function. It is valid to all orders in g , where g denotes a SM gauge or quark Yukawa coupling. We use it to compute the rate for generating a matter-antimatter asymmetry at next-to-leading order in g in the non-relativistic regime. The corrections are of order g {sup 2}, and they amount to 4% or less.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calculating Mode Mixity in Interlaminar Fracture of Composite Laminates

To accurately predict delamination under mixed-mode loading, cohesive elements must partition the energies dissipated in Mode I and Mode II correctly. The ability of cohesive models to predict mode mixity was evaluated by performing analyses of the single leg bending (SLB) test, which exhibits a variable mode mixity with crack length. Accordingly, two numerical integration methods were developed to compute the energy partitioning: (i) a local calculation of the accumulated work of tractions at each point along the crack path, and (ii) a global J-integral “snapshot” calculation along a contour around the process zone. In the case of a composite laminate with properties characterized by short fracture process zone (FPZ), the results of these two methods correlate well with each other and with a linear elastic fracture mechanics solution. However, FPZscan be long due to fiber bridging or due to the intrinsic toughness of the material. Then, the results of mode-mixity calculations obtained with various methods vary widely from each other. It is argued that the global J-integral calculation is the most accurate interpretation of the energy release rate and mode mixity for either short or long process zones. This solution will provide a more accurate characterization of resistance curves and mode mixity in experimental results, and it will also guide the development of more accurate mixed-mode cohesive laws for tougher materials characterized by strong R-curve responses, such as thermo-plastic composites.

cohesive zone analysis↗

X-ray spectral measurements for tungsten-anode from 20 to 49 kVp on a digital breast tomosynthesis system

Purpose: This paper presents new spectral measurements of a tungsten-target digital breast tomosynthesis (DBT) system, including spectra of 43-49 kVp. Methods: Raw x-ray spectra of 20-49 kVp were directly measured from the tube port of a Selenia Dimensions DBT system using a CdTe based spectrometer. Two configurations of collimation were employed: one with two tungsten pinholes of 25{mu}m and 200{mu}m diameters, and the other with a single pinhole of 25{mu}m diameter, for acquiring spectra from the focal spot and from the focal spot as well as its vicinity. Stripping correction was applied to the measured spectra to compensate distortions due to escape events. The measured spectra were compared with the existing mammographic spectra of the TASMIP model in terms of photon fluence per exposure, spectral components, and half-value layer (HVL). HVLs were calculated from the spectra with a numerical filtration of 0.7 mm aluminum and were compared against actual measurements on the DBT system using W/Al (target-filter) combination, without paddle in the beam. Results: The spectra from the double-pinhole configuration, in which the acceptance aperture pointed right at the focal spot, were harder than the single-pinhole spectra which include both primary and off-focus radiation. HVL calculated from the single-pinhole setup agreed with the measured HVL within 0.04 mm aluminum, while the HVL values from the double-pinhole setup were larger than the single-pinhole HVL by at most 0.1 mm aluminum. The spectra from single-pinhole setup agreed well with the TASMIP mammographic spectra, and are more relevant for clinical purpose. Conclusions: The spectra data would be useful for future research on DBT system with tungsten targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-size and cluster dynamics modeling of intra-granular fission gas bubbles in UO 2

For this work, we perform simulations of intra-granular fission gas bubble evolution in UO 2 using both a relatively simple, computationally inexpensive single-size model and a detailed cluster dynamics model. Simulations encompass 36 experimental cases from 4 different databases, covering various temperature and burnup levels. We systematically compare results from the two models to each other and to post-irradiation experimental data of bubble average size and number density. Overall, the model-to-model comparisons reveal an excellent agreement across the set of simulations. This outcome indicates that, in spite of the underlying assumptions, the single-size model provides a good approximation of the complex physical behavior that is more rigorously described by the cluster dynamics model. Qualitatively, both models reproduce the trends of the experimental data with temperature and burnup correctly. Quantitatively, calculated results are either in good agreement with the data or within errors that appear consistent with the inherent uncertainties. Moreover, for the single-size model, we demonstrate and assess a multiscale approach whereby values for the fission gas atom diffusion coefficient from separate atomistic calculations are used. Systematic comparisons to experimental data point out a credible accuracy of the multiscale model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-595: Output Factor Calculation for a Uniform Scanning Proton Therapy System

Purpose: To develop an analytical model that predicts dose output factors for patient treatment fields in a uniform scanning proton therapy system. Methods: A model to predict output factors for patient specific treatment fields was produced based on the methods developed by Kooy et al. (2003). The Kooy model predicts the output factor based on the ratio of the entrance dose under calibration conditions to that for a given range and modulation corrected for the inverse square effect. Field specific output factors were plotted as a function of a single parameter r, where r = (Range-Modulation)/Modulation. The model targeted user range 1 sub-span 3 through user range 2 sup-span 2 of the IBA uniform scanning proton therapy system. The data set included points measured using the 10 cm and 18 cm snout sizes to eliminate stem effects on the monitor unit chambers. The data was fit using equation 15 from Kooy et al. (2003), and the resulting model was tested against measurements that were not included in the original data set. Results: For the range and sub span investigated, 120 data points were tested against the model prediction. The model predicted the output factor within 2% for 96% of the points tested and within 2.5% for 99% of the points tested. All points were within 3% of the predicted values. Conclusion: Monitor units for patient treatment fields with proton ranges that fall within the tested interval can be predicted using a model based on the methods developed at MGH. With further evaluation, it will be possible to model all user ranges and sub-spans of the IBA system. Further testing is also needed to predict output factors using a 25 cm snout which introduces variable scanning pattern sizes and stem effects on the monitor unit chambers.

61 RADIATION PROTECTION AND DOSIMETRY↗

High-Throughput, Adaptive FFT Architecture for FPGA-Based Spaceborne Data Processors

Exponential growth in microelectronics technology such as field-programmable gate arrays (FPGAs) has enabled high-performance spaceborne instruments with increasing onboard data processing capabilities. As a commonly used digital signal processing (DSP) building block, fast Fourier transform (FFT) has been of great interest in onboard data processing applications, which needs to strike a reasonable balance between high-performance (throughput, block size, etc.) and low resource usage (power, silicon footprint, etc.). It is also desirable to be designed so that a single design can be reused and adapted into instruments with different requirements. The Multi-Pass Wide Kernel FFT (MPWK-FFT) architecture was developed, in which the high-throughput benefits of the parallel FFT structure and the low resource usage of Singleton s single butterfly method is exploited. The result is a wide-kernel, multipass, adaptive FFT architecture. The 32K-point MPWK-FFT architecture includes 32 radix-2 butterflies, 64 FIFOs to store the real inputs, 64 FIFOs to store the imaginary inputs, complex twiddle factor storage, and FIFO logic to route the outputs to the correct FIFO. The inputs are stored in sequential fashion into the FIFOs, and the outputs of each butterfly are sequentially written first into the even FIFO, then the odd FIFO. Because of the order of the outputs written into the FIFOs, the depth of the even FIFOs, which are 768 each, are 1.5 times larger than the odd FIFOs, which are 512 each. The total memory needed for data storage, assuming that each sample is 36 bits, is 2.95 Mbits. The twiddle factors are stored in internal ROM inside the FPGA for fast access time. The total memory size to store the twiddle factors is 589.9Kbits. This FFT structure combines the benefits of high throughput from the parallel FFT kernels and low resource usage from the multi-pass FFT kernels with desired adaptability. Space instrument missions that need onboard FFT capabilities such as the proposed DESDynl, SWOT (Surface Water Ocean Topography), and Europa sounding radar missions would greatly benefit from this technology with significant reductions in non-recurring cost and risk.

NguyenKobayashi, Kayla↗

FOUR PI CALIBRATION AND MODELING OF A BARE GERMANIUM DETECTOR IN A CYLINDRICAL FIELD SOURCE

In reference 1 the authors described {gamma}-ray holdup assay of a Mossbauer spectroscopy instrument where they utilized two axial symmetric cylindrical shell acquisitions and two disk source acquisitions to determine Am-241 and Np-237 contamination. The measured contents of the two species were determined using a general detector efficiency calibration taken from a 12-inch point source.2 The authors corrected the raw spectra for container absorption as well as for geometry corrections to transform the calibration curve to the applicable axial symmetric cylindrical source - and disk source - of contamination. The authors derived the geometry corrections with exact calculus that are shown in equations (1) and (2) of our Experimental section. A cylindrical shell (oven source) acquisition configuration is described in reference 3, where the authors disclosed this configuration to gain improved sensitivity for holdup measure of U-235 in a ten-chamber oven. The oven was a piece of process equipment used in the Savannah River Plant M-Area Uranium Fuel Fabrication plant for which a U-235 holdup measurement was necessary for its decontamination and decommissioning in 2003.4 In reference 4 the authors calibrated a bare NaI detector for these U-235 holdup measurements. In references 5 and 6 the authors calibrated a bare HpGe detector in a cylindrical shell configuration for improved sensitivity measurements of U-235 in other M-Area process equipment. Sensitivity was vastly improved compared to a close field view of the sample, with detection efficiency of greater than 1% for the 185.7-keV {gamma}-ray from U-235. In none of references 3 - 7 did the authors resolve the exact calculus descriptions of the acquisition configurations. Only the empirical efficiency for detection of the 185.7-keV photon from U-235 decay was obtained. Not until the 2010 paper of reference 1 did the authors derive a good theoretical description of the flux of photons onto the front face of a detector from an axially symmetric cylindrical shell. Subsequent to publication of 1, the theoretical treatment of the cylindrical shell and disk source acquisition sources was recognized by the Los Alamos National Laboratory as suitable for including in the Safeguards Training Program.8 Therefore, we felt it was important to accurately demonstrate the calculus describing the cylindrical shell configuration for the HpGe detector and to theoretically account for the observed bare-detector efficiencies measured in references (3-6). In this paper we demonstrate the applicability of the cylindrical shell derivation to a flexible planar sheet of known Am-241, Eu-152, and Cs-137 activity that we rolled into a symmetrical cylindrical shell of radioactivity. Using the geometry correction equation of reference 1, we calculate geometry correction values using the known detector and source dimensions combined with source to detector distances. We then compare measured detection efficiencies from a cylindrical shell of activity for the 185.7-keV photon (U-235) and for the 414.3-keV photon (Pu-239) with those determined for a 12-inch point source(2,7) to demonstrate agreement between experiment and the theoretically calculated values derived by the Savannah River National Laboratory (SRNL) authors of reference 1. We demonstrate this geometry correction first for the 185.7- and 414.3-keV {gamma}-rays. But because the detector was point source calibrated at 12 inches for the energy range (60 -1700) keV (using two distinct sources) to map its intrinsic efficiency, the geometry correction for any acquisition configuration holds for all photon energies.2 We demonstrate that for ten photon energies in the range 121 keV to 967 keV. The good agreement between experiment and calculation is demonstrated at five source to detector distances using the identical shielded HpGe detector of references 4-7 as well as with a separate HpGe detector. We then extend the measurement to include a single acquisition where the flexible source is wrapped around the bare detector in a symmetrical cylinder that radiates on both faces of the detector as well as on to the detector's cylindrical sides of known dimensions. We derive the exact calculus to calculate the flux of the source on to the cylindrical sides of the detector. We then demonstrate outstanding agreement between the measured efficiency for the two primary U-235 and Pu-239 photons in this oven source configuration compared to the point source of activity for which the detector was originally calibrated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Downward quantum learning from element 118: Automated generation of Fermi–Löwdin orbitals for all atoms

A new algorithm based on a rigorous theorem and quantum data computationally mined from element 118 guarantees automated construction of initial Fermi–Löwdin-Orbital (FLO) starting points for all elements in the Periodic Table. It defines a means for constructing a small library of scalable FLOs for universal use in molecular and solid-state calculations. The method can be systematically improved for greater efficiency and for applications to excited states such as x-ray excitations and optically silent excitations. FLOs were introduced to recast the Perdew–Zunger self-interaction correction (PZSIC) into an explicit unitarily invariant form. The FLOs are generated from a set of N quasi-classical electron positions, referred to as Fermi-Orbital descriptors (FODs), and a set of N-orthonormal single-electron orbitals. FOD positions, when optimized, minimize the PZSIC total energy. However, creating sets of starting FODs that lead to a positive definite Fermi orbital overlap matrix has proven to be challenging for systems composed of open-shell atoms and ions. The proof herein guarantees the existence of a FLOSIC solution and further guarantees that if a solution for N electrons is found, it can be used to generate a minimum of N – 1 and a maximum of 2 N – 2 initial starting points for systems composed of a smaller number of electrons. As a result, applications to heavy and super-heavy atoms are presented. All starting solutions reported here were obtained from a solution for element 118, Oganesson.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-G-BRB-05: Automation of the Photon Dosimetric Quality Assurance Program of a Linear Accelerator

Purpose: To develop an automated method to calculate a linear accelerator (LINAC) photon radiation field size, flatness, symmetry, output and beam quality in a single delivery for flattened (FF) and flattening-filter-free (FFF) beams using an ionization chamber array. Methods: The proposed method consists of three control points that deliver 30×30, 10×10 and 5×5cm{sup 2} fields (FF or FFF) in a step-and-shoot sequence where the number of monitor units is weighted for each field size. The IC Profiler (Sun Nuclear Inc.) with 5mm detector spacing was used for this study. The corrected counts (CCs) were calculated and the locations of the maxima and minima values of the first-order gradient determined data of each sub field. Then, all CCs for each field size are summed in order to obtain the final profiles. For each profile, the radiation field size, symmetry, flatness, output factor and beam quality were calculated. For field size calculation, a parameterized gradient method was used. For method validation, profiles were collected in the detector array both, individually and as part of the step-and-shoot plan, with 9.9cm buildup for FF and FFF beams at 90cm source-to-surface distance. The same data were collected with the device (plus buildup) placed on a movable platform to achieve a 1mm resolution. Results: The differences between the dosimetric quantities calculated from both deliveries, individually and step-and-shoot, were within 0.31±0.20% and 0.04±0.02mm. The differences between the calculated field sizes with 5mm and 1mm resolution were ±0.1mm. Conclusion: The proposed single delivery method proved to be simple and efficient in automating the photon dosimetric monthly and annual quality assurance.

61 RADIATION PROTECTION AND DOSIMETRY↗

An improved multipole approximation for self-gravity and its importance for core-collapse supernova simulations

Self-gravity computation by multipole expansion is a common approach in problems such as core-collapse and Type Ia supernovae, where single large condensations of mass must be treated. The standard formulation of multipole self-gravity in arbitrary coordinate systems suffers from two significant sources of error, which we correct in the formulation presented in this article. The first source of error is due to the numerical approximation that effectively places grid cell mass at the central point of the cell, then computes the gravitational potential at that point, resulting in a convergence failure of the multipole expansion. We describe a new scheme that avoids this problem by computing gravitational potential at cell faces. The second source of error is due to sub-optimal choice of location for the expansion center, which results in angular power at high multipole l values in the gravitational field, requiring a high—and expensive—value of multipole cutoff l {sub max}. By introducing a global measure of angular power in the gravitational field, we show that the optimal coordinate for the expansion is the square-density-weighted mean location. We subject our new multipole self-gravity algorithm, implemented in the FLASH simulation framework, to two rigorous test problems: MacLaurin spheroids for which exact analytic solutions are known, and core-collapse supernovae. We show that key observables of the core-collapse simulations, particularly shock expansion, proto-neutron star motion, and momentum conservation, are extremely sensitive to the accuracy of the multipole gravity, and the accuracy of their computation is greatly improved by our reformulated solver.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-228: Liquid Ionisation Chamber Array and MicroDiamond Measurements with the CyberKnife System

Purpose: The aim of this study was to measure the dose profile and output factors with a CyberKnife accelerator using a TM60019 microDiamond detector and a 1000SRS liquid chamber array (both PTW Freiburg, Germany). Methods: An MP3 water phantom (PTW, Freiburg) was positioned along the robotic world coordinate system. The TM60019 detector was adjusted to the center of the according fields and the semiconductor axis was aligned with the beam direction. Profiles at 5cm water depth and SSD = 80 cm were measured along the robotic x axis and y axis for the cylindrical collimators of the CyberKnife (diameter 60, 50, 40, 30, 20, 15, 12.5, 10, 7.5 and 5mm). To determine the output factors the dose profile was measured at 0.1 mm steps around the field center to find the maximum dose value. The liquid chamber array (1000SRS) measurement was performed with the same setup, but with RW3 buildup. Results: The 1000SRS measurements closely conform with the TM60019 profile measurement in all profile regions and for all collimator sizes. The profile measurement is influenced by the almost equal spatial resolution of the TM60019 detector (radius of the sensitive area 1.1mm) and of the 1000SRS liquid chamber array (single chamber width 2.3mm). The measured dose profiles have not been corrected for this limited spatial resolution. Rather we purpose to consider that spatial dose averaging over 2 mm wide regions might be justified in view of patient positioning inaccuracies and of the spaces in tissue participating in the biological radiation responses. Conclusion: The 1000SRS data points conform with the TM60019 profile measurements at all profile regions showing the applicability of liquid ion chamber arrays with the CyberKnife system.

60 APPLIED LIFE SCIENCES↗