A conceptual design study of a high temperature solar thermal receiver (added tasks 6 and 7)

The key component of this concept is a coiled tube of silicon nitride which acts as a heat exchanger appears to be ideal from the standpoint of utilizing structural ceramics at around 2500 F under severe thermal shock conditions. However the size and configuration of this coil are beyond the state of the art for fabricating such materials as silicon nitride and carbide. A two-task program to develop and demonstrate the feasibility of extruding and forming a section of thin walled silicon nitride tubing was undertaken as an addition to the original program. A promising polyvinyl butyral-based binder lubricant was identified. Fourteen full size extrusion experiments were conducted. Two trial firings of 1-1/4 turn helices were made.

Robertson, C. S.↗

Parabolic Dish Solar Thermal Power Annual Program Review Proceedings

The development and testing of concentrators, receivers, and power conversion units are reported. System design and development for engineering experiments are described. Economic analysis and market assessments for advanced development activities are discussed. Technology development issues and application/user needs are highlighted.

Holbeck, H. J.↗

Solar thermal parabolic dish energy applications

Vu-graphs are presented that show that applications are a viable distributed renewable power generation option. Quality energy can be produced in the form of electricity and high temperature heat. Modular systems are described that can be distributed to new or existing plants and that are mass producible with the associated economies of production.

Pijawka, W.↗

A comparative assessment of solar thermal electric power plants in the 1-10 MWe range

The candidate power system technologies were ranked in terms of the cost of electric energy each system produces. In all cases, it was assumed that development programs would result in mature power plant systems that could be commercially manufactured. The results of the study, a brief description of the systems examined, and the methodologies used are presented.

Rosenberg, L. S.↗

Effects off system factors on the economics of and demand for small solar thermal power systems

Market penetration as a function time, SPS performance factors, and market/economic considerations was estimated, and commercialization strategies were formulated. A market analysis task included personal interviews and supplemental mail surveys to acquire statistical data and to identify and measure attitudes, reactions and intentions of prospective SPS users. Interviews encompassed three ownership classes of electric utilities and industrial firms in the SIC codes for energy consumption. A market demand model was developed which utilized the data base developed, and projected energy price and consumption data to perform sensitivity analyses and estimate potential market for SPS.

Source record↗

Control system development for a 1 MW/e/ solar thermal power plant

The point-focusing distributed receiver power plant considered consists of a number of power modules delivering power to a central collection point. Each power module contains a parabolic dish concentrator with a closed-cycle receiver/turbine/alternator assembly. Currently, a single-module prototype plant is under construction. The major control system tasks required are related to concentrator pointing control, receiver temperature control, and turbine speed control. Attention is given to operational control details, control hardware and software, and aspects of CRT output display.

Daubert, E. R.↗

Air Force Logistics Command (AFLC) solar thermal plant

The plant proved its capability to deliver the desired energy product in a USAF industrial environment. The collector proved capable of energy conversion at insolation levels up to 25% below design minimum. The plant and the project were negatively affected by severe winter weather, with total insolation during the test period 60 percent less than the expected value. Environmental effects reduced plant availability to 55 percent. Only five, minimally good operating days were experienced during the test period. The subsequent lack of performance data prohibits the drawing of general conclusions regarding system performance. System operability was rated generally high. The only inhibiting factor was the difficulty in procuring replacement parts for rapid repair under USAF stockage and procurement policies. No inherently serious system failures were recorded, although a thermostatic valve malfunction in the freeze protection system ultimately took 30 days to repair.

Source record↗

On Solar Thermal Electric Power Capacity Sizing

The commercialization of parabolic dish/generator modules are investigated. Design analysis indicates that a 10 sq m/ three kilowatt generator configuration is simple and easy to maintain, manufacturing is easily adaptable, the demand is already established, the unit is cost effective and the hardware is readily available.

Clark, J. S.↗

On the rate of energy input in thermal solar flares

The rise phases of solar soft X-ray flares observed by X-ray crystal spectrometers on P78-1 are discussed in terms of the rate of change of X-ray flux as a function of time. It is shown that the flux increases exponentially over most of the rise time. The e-folding time (tau) has a cutoff at approximately 13 s. Soft X-ray flares with smaller values of tau are not observed. It is suggested that this phenomenon is due to the ability of the solar atmosphere to absorb the input energy and convert it into a typical soft X-ray flare, when the value of tau is greater than about 13 s. For energy input rates with tau greater than about 13 s, the temperature attained by the plasma is typically around 2 x 10 to the 7th K, but for values of tau less than 13 s, the gas is heated to much higher temperatures (about 10 to the 8th K), producing a certain class of hard X-ray flares.

Feldman, U.↗

Test results of an organic Rankine-cycle power module for a small community solar thermal power experiment

The organic Rankine-cycle (ORC) power conversion assembly was tested. Qualification testing of the electrical transport subsystem was also completed. Test objectives were to verify compatibility of all system elements with emphasis on control of the power conversion assembly, to evaluate the performance and efficiency of the components, and to validate operating procedures. After 34 hours of power generation under a wide range of conditions, the net module efficiency exceeded 18% after accounting for all parasitic losses.

Clark, T. B.↗

Exotic power and propulsion concepts

The status of some exotic physical phenomena and unconventional spacecraft concepts that might produce breakthroughs in power and propulsion in the 21st Century are reviewed. The subjects covered include: electric, nuclear fission, nuclear fusion, antimatter, high energy density materials, metallic hydrogen, laser thermal, solar thermal, solar sail, magnetic sail, and tether propulsion.

Forward, Robert L.↗

Solar panel thermal cycling testing by solar simulation and infrared radiation methods

For the solar panels of the European Space Agency (ESA) satellites OTS/MAROTS and ECS/MARECS the thermal cycling tests were performed by using solar simulation methods. The performance data of two different solar simulators used and the thermal test results are described. The solar simulation thermal cycling tests for the ECS/MARECS solar panels were carried out with the aid of a rotatable multipanel test rig by which simultaneous testing of three solar panels was possible. As an alternative thermal test method, the capability of an infrared radiation method was studied and infrared simulation tests for the ultralight panel and the INTELSAT 5 solar panels were performed. The setup and the characteristics of the infrared radiation unit using a quartz lamp array of approx. 15 sq and LN2-cooled shutter and the thermal test results are presented. The irradiation uniformity, the solar panel temperature distribution, temperature changing rates for both test methods are compared. Results indicate the infrared simulation is an effective solar panel thermal testing method.