Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Tower”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

MODELING AND METHOD FOR OPTICAL PERFORMANCE OF A RECEIVER COATING AND ITS DEGRADATION DUE TO OPERATION

The optical properties of the coating used on a concentrated solar power (CSP)’s receiver directly impact the performance of the power plant. Receiver coatings are designed to absorb as much heat as possible and transfer it to the circulating fluid. Over time, the absorptivity of the receiver coating degrades due to environmental and operational conditions. This project aims to (1) create a test apparatus that allows coatings to undergo accelerated lifetime testing under conditions that mimic what the coating will experience on-tower; and (2) develop a mathematical model that based on the test data predicts absorptivity over time. To create the mathematical model, samples of BrightSource Energy’s Gen1 and Gen2 coatings were tested first looking at individual failure modes (such as high temperature cycling) and then for combined failure modes in the newly developed apparatus. In addition to taking optical measurements, the samples were destroyed to allow for metalogical evaluation to understand what was happening on a microscopic level. Pre-existing models from the literature that describe accelerated testing as well as individual phenomena observed in the coating were then combined to create the model. Additionally, the Gen2 and Gen3 coatings are being testing at the Plataforma Solar de Almería (PSA) facility in Almeria, Spain to confirm that the apparatus test results are similar to those received on-sun. (PSA’s facility closely mimics on-tower conditions). The goal is to enable industry players to test coatings using the new apparatus, gather absorptivity measurements (without needing to destroy samples), and input the information into the model to determine how the coating will perform over time, thus allowing the optical performance of coatings to be compared even before they are used on-tower. The model will be publicly available by the end of the project (currently projected as December 2024).

14 SOLAR ENERGY↗

Beyond the visible: Accounting for ultraviolet and far‐red radiation in vegetation productivity and surface energy budgets

Photosynthetically active radiation (PAR) is typically defined as light with a wavelength within 400–700 nm. However, ultra-violet (UV) radiation within 280–400 nm and far-red (FR) radiation within 700–750 nm can also excite photosystems, though not as efficiently as PAR. Vegetation and land surface models (LSMs) typically do not explicitly account for UV's contribution to energy budgets or photosynthesis, nor FR's contribution to photosynthesis. However, whether neglecting UV and FR has significant impacts remains unknown. Here, we explored how canopy radiative transfer (RT) and photosynthesis are impacted when explicitly implementing UV in the canopy RT model and accounting for UV and FR in the photosynthesis models within a next-generation LSM that can simulate hyperspectral canopy RT. We validated our improvements using photosynthesis measurements from plants under different light sources and intensities and surface reflection from an eddy-covariance tower. Our model simulations suggested that at the whole plant level, after accounting for UV and FR explicitly, chlorophyll content, leaf area index (LAI), clumping index, and solar radiation all impact the modeling of gross primary productivity (GPP). At the global scale, mean annual GPP within a grid would increase by up to 7.3% and the increase is proportional to LAI; globally integrated GPP increases by 4.6 PgC year −1 (3.8% of the GPP without accounting for UV + FR). Further, using PAR to proxy UV could overestimate surface albedo by more than 0.1, particularly in the boreal forests. Our results highlight the importance of improving UV and FR in canopy RT and photosynthesis modeling and the necessity to implement hyperspectral or multispectral canopy RT schemes in future vegetation and LSMs.

energy budget↗

Determining surface solar absorption from broadband satellite measurements for clear skies - Comparison with surface measurements

Using data from collocated satellite pixel measurements obtained during the Earth Radiation Budget Experiement and near-surface measurements carried out at the Boulder Atmospheric Observatory Tower, the shortwave (SW) surface radiation from broadband satellite measurements for clear-sky conditions was compared with surface measurements. Results demonstrate that the surface-SW absorption is a more meaningful quantity for climate studies than is surface insolation. It is also shown that a direct evaluation of the surface-SW absorption can be more accurately obtained from satellite measurements than can be surface insolation. An algorithm is presented for transferring satellite SW measurements to surface-SW absorption.

Cess, Robert D.↗

Satellite solar-induced chlorophyll fluorescence and near-infrared reflectance capture complementary aspects of dryland vegetation productivity dynamics

Mounting evidence indicates dryland ecosystems play an important role in driving the interannual variability and trend of the terrestrial carbon sink. Nevertheless, our understanding of the seasonal dynamics of dryland ecosystem carbon uptake through photosynthesis [gross primary productivity (GPP)] remains relatively limited due in part to the limited availability of long-term data and unique challenges associated with satellite remote sensing across dryland ecosystems. Here, we comprehensively evaluated longstanding and emerging satellite vegetation proxies in their ability to capture seasonal dryland GPP dynamics. Specifically, we evaluated: 1) reflectance-based proxies normalized difference vegetation index (NDVI), soil adjusted vegetation index (SAVI), near infrared reflectance index (NIR v ), and kernel NDVI (kNDVI) from the MODerate resolution Imaging Spectroradiometer (MODIS); and 2) newly available physiologically-based proxy solar-induced chlorophyll fluorescence (SIF) from the TROPOspheric Monitoring Instrument (TROPOMI). As a performance benchmark, we used GPP estimates from a robust network of 21 western United States eddy covariance tower sites that span representative gradients in dryland ecosystem climate and functional composition. We found that NIR v and SIF were the best performing GPP proxies and captured complementary aspects of seasonal GPP dynamics across dryland ecosystem types. NIR v offered better performance than the other proxies across relatively low-productivity, sparsely non-evergreen vegetated sites (R 2 = 0.59 ± 0.13); whereas SIF best captured seasonal dynamics across relatively high-productivity sites, including evergreen-dominated sites (R 2 = 0.74 ± 0.07). Notably, across grass-dominated sites, all reflectance-based proxies (NDVI, SAVI, NIRv and kNDVI) showed significant seasonal bias (hysteresis) that strengthened with the total fraction of woody vegetation cover, likely due to seasonal patterns in woody vegetation reflectance that are unrelated to or decoupled from GPP. In conclusion, future efforts to fully integrate the complementary strengths of NIR v and SIF could significantly improve our understanding and representation of dryland GPP dynamics in satellite-based models.

54 ENVIRONMENTAL SCIENCES↗

Reduced order modeling of a fluidized bed particle receiver for concentrating solar power with thermal energy storage

Oxide particles can serve as both the heat transfer and thermal energy storage (TES) media for next-generation concentrating solar power (CSP) plants where high-temperature TES enables dispatchable electricity from efficient power cycles with firing temperatures above 600 °C. Transferring heat to flowing particles at such high temperatures in a MW-scale central tower receiver remains a challenge for the CSP community. For indirect receivers with external walls to contain the particles, maintaining wall temperatures below the limits of structural metal alloys requires high heat transfer coefficients between the wall and the moving particle stream. Bubbling fluidization of downward-flowing particles can sustain high bed-wall heat transfer coefficients (> 1000 W m -2 K -1 ). Using experimentally calibrated correlations for bed-wall heat transfer and vertical particle dispersion, this study implements an axially discretized zonal model of a counterflow fluidized bed receiver to explore how bubbling fluidization may enable indirect cavity particle receivers. High bed-wall heat transfer coefficients support solar fluxes on angled cavity walls > 200 kW m -2 at peak aperture fluxes of 980 kW m -2 while maintaining external wall temperatures < 950 °C. Lateral particle dispersion enables hotter particles near the receiver leading edge to mix with cooler particles further from the leading edge to lower maximum external wall temperatures. Parametric studies identify how mass fluxes, particle dispersion, and solar concentrations impact indirect receiver thermal efficiency and uniformity for a CSP plant. These studies provide a basis for the design of indirect fluidized-bed cavity receivers that can maintain particle outlet temperatures for TES above 750 °C.

14 SOLAR ENERGY↗

Spaceborne Sun-Induced Vegetation Fluorescence Time Series from 2007 to 2015 Evaluated with Australian Flux Tower Measurements

A global, monthly averaged time series of Sun-induced Fluorescence (SiF), spanning January 2007 to June 2015, was derived from Metop-A Global Ozone Monitoring Experiment 2 (GOME-2) spectral measurements. Far-red SiF was retrieved using the filling-in of deep solar Fraunhofer lines and atmospheric absorption bands based on the general methodology described by Joiner et al, AMT, 2013. A Principal Component (PC) analysis of spectra over non-vegetated areas was performed to describe the effects of atmospheric absorption. Our implementation (SiF KNMI) is an independent algorithm and differs from the latest implementation of Joiner et al, AMT, 2013 (SiF NASA, v26), because we used desert reference areas for determining PCs (as opposed to cloudy ocean and some desert) and a wider fit window that covers water vapour and oxygen absorption bands (as opposed to only Fraunhofer lines). As a consequence, more PCs were needed (35 as opposed to 12). The two time series (SiF KNMI and SiF NASA, v26) correlate well (overall R of 0.78) except for tropical rain forests. Sensitivity experiments suggest the strong impact of the water vapour absorption band on retrieved SiF values. Furthermore, we evaluated the SiF time series with Gross Primary Productivity (GPP) derived from twelve flux towers in Australia. Correlations for individual towers range from 0.37 to 0.84. They are particularly high for managed biome types. In the de-seasonalized Australian SiF time series, the break of the Millennium Drought during local summer of 2010/2011 is clearly observed.

Australia↗

CSP Plant Construction, Start-Up, and O&M Best Practices Study

There are currently 90 operational CSP plants of 10 MW or larger located throughout the world, primarily in Spain, U.S., MENA region, South Africa, and China. In 2018, the U.S. Department of Energy (DOE) funded Solar Dynamics, under subcontract to NREL, to investigate and document lessons learned and best practices associated with the construction, start-up, and operations phases of a majority of these plants. DOE funding for the effort was leveraged by additional funds provided through SolarPACES and the World Bank. This information was obtained by interviewing key stakeholders representing CSP plant owners, operators, construction companies, vendors, technical advisors and financers of these systems, and will be published as an NREL Technical Report at the completion of the project. This paper provides an overview of key challenges facing today's CSP parabolic trough and power tower technologies during all the phases mentioned above.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Large-scale solar thermal collector concepts

Thermal collector could be used ultimately to power steamplant to produce electricity. Collector would consist of two major subsystems: (1) series of segmented tracking mirrors with two axes of rotation and (2) absorber mounted on centrally located tower.

Brantley, L. W., Jr.↗

CSP Plant Optimization Study for the California Power Market (“CalCSP”) (Final Technical Report)

Concentrating Solar Power (CSP) with thermal energy storage offers a unique and strategic opportunity to support California’s clean energy transition. Unlike photovoltaic (PV) systems, CSP with thermal storage can generate electricity after sunset and during periods of high demand, making it a valuable complement to intermittent renewable resources. CSP also provides synchronous, inertia-contributing generation, long-duration storage, and flexible dispatch—capabilities increasingly important as thermal plants retire. This report summarizes the findings of the CSP Plant Optimization Study for the California Power Market or “CalCSP study,” which evaluated the technical, economic, environmental, and policy factors that influence the deployment of CSP technologies in California. The CalCSP study was conducted to assess how CSP can contribute to California’s long-term decarbonization goals while enhancing grid reliability, supporting local economic development, and making efficient use of land and transmission resources. It draws on detailed modeling of CSP performance and costs, site suitability analysis, policy reviews, and stakeholder engagement across utilities, regulators, developers, and community organizations. The analysis focuses on mature molten-salt tower technology and incorporates lessons learned from the global CSP fleet, distinguishing today’s CSP from earlier first-of-a-kind projects in the U.S. The findings support a more prominent role for CSP in California’s evolving clean energy landscape. With strategic planning, targeted policy support, and continued cost improvements, CSP can complement PV and batteries to deliver reliable, around-the-clock clean electricity—especially in areas with high solar resource and constrained grid capacity.

14 SOLAR ENERGY↗

High Toughness Cermets for Molten Salt Pumps

Concentrated Solar Power plants using nitrate salts used cantilevered pump designs to avoid use of bearings in the 565°C salt; however, this necessitated the use of a sump that added additional cost, complexity, and thermal losses. Sump systems had their own complications, including risk of flooding the sump due to control issues either with level indicators or failures in the control valve responsible for filling the sump. Long-shafted pumps were developed and tested, and they outline the need to develop journal sleeves and bearings for new salt systems. Based on reports, pumps will need to be a vertical single- or multi-stage type, mounted to the roof of the molten salt tanks. Design and service for molten salt pumps above 550°C is relatively limited, and at temperatures up to 750°C there is no available design or service experience. Long-shaft pumps that extend to the bottom of the thermal energy storage tank will require bearing materials that are suitable to the given salt chemistry. Lubricity of proposed salts is unclear and need to be determined, especially for cold-tank pumps that require multi-stages for lifting the salt to the top of the tower. Materials, design, and maintenance are all major unknowns.

14 SOLAR ENERGY↗

Wash Vehicle Fleet Sizing for Contingency Planning Against Dust Storms

Wash vehicles containing either high- or low-pressure water sprayers, a collection of rotating brushes, or a combination of these, are frequently utilized in concentrating solar power (CSP) plants to maintain a high level of optical efficiency in the solar field. In recent years, multiple modeling approaches have been developed to obtain fleet sizes and mirror-washing schedules that optimize the tradeoff of vehicle capital and use costs and labor versus lost revenues due to soiling. These planning models cover normal operating conditions well but do not consider rare events such as dust storms which can cause a significant reduction in receiver productivity, or shut down operations until most or all of the solar field's mirrors have been cleaned. To that end, we propose a methodology that evaluates whether additional capital should be deployed to hedge against these events by weighing the net present value of the expected benefits against the capital costs. The output of this method is a breakeven frequency, a metric we sue to determine whether an additional vehicle should be purchased to address the contingency of dust storms by comparing it to the expected annual storm frequency We develop a small collection of case studies using commercial-scale CSP tower plants and obtain breakeven frequencies that mostly fall between 0.1 and 1.0 storms per year, depending on the existing fleet size and storm severity.

concentrating solar power↗

Wash Vehicle Fleet Sizing for Contingency Planning Against Dust Storms: Preprint

Wash vehicles containing either high- or low-pressure water sprayers, a collection of rotating brushes, or a combination of these, are frequently utilized in concentrating solar power (CSP) plants to maintain a high level of optical efficiency in the solar field. In recent years, multiple modeling approaches have been developed to obtain fleet sizes and mirror-washing schedules that optimize the tradeoff of vehicle capital and use costs and labor versus lost revenues due to soiling. These planning models cover normal operating conditions well but do not consider rare events such as dust storms which can a significant reduction in receiver productivity, or shut down operations until most or all of the solar field’s mirrors have been cleaned. To that end, we propose a methodology that evaluates whether additional capital should be deployed to hedge against these events by weighing the net present value of the expected benefits against the capital costs. The output of this method is a breakeven frequency, a metric we sue to determine whether an additional vehicle should be purchased to address the contingency of dust storms by comparing it to the expected annual storm frequency We develop a small collection of case studies using commercial-scale CSP tower plants and obtain breakeven frequencies that mostly fall between 0.1 and 1.0 storms per year, depending on the existing fleet size and storm severity.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Field research on the spectral properties of crops and soils, volume 1

The experiment design, data acquisition and preprocessing, data base management, analysis results and development of instrumentation for the AgRISTARS Supporting Research Project, Field Research task are described. Results of several investigations on the spectral reflectance of corn and soybean canopies as influenced by cultural practices, development stage and nitrogen nutrition are reported as well as results of analyses of the spectral properties of crop canopies as a function of canopy geometry, row orientation, sensor view angle and solar illumination angle are presented. The objectives, experiment designs and data acquired in 1980 for field research experiments are described. The development and performance characteristics of a prototype multiband radiometer, data logger, and aerial tower for field research are discussed.

Bauer, M. E.↗

Potential of hotspot solar‐induced chlorophyll fluorescence for better tracking terrestrial photosynthesis

Abstract Remote sensing of solar‐induced fluorescence (SIF) opens a new window for quantifying a key ecological variable, the terrestrial ecosystem gross primary production (GPP), because of the revealed strong SIF–GPP correlation. However, similar to many other remotely sensed metrics, SIF observations suffer from the sun‐sensor geometry effects, which may have important impacts on the SIF–GPP relationship but remain poorly understood. Here we used remotely sensed SIF, globally distributed tower GPP data, and a mechanistic model to provide a systematic analysis. Our results reveal that leaf physiology, canopy structure, and sun‐sensor geometries all affect the SIF–GPP relationship. In particular, we found that SIF observations in the sun‐tracking hotspot direction can be a better proxy of GPP due to the similar responses of light use efficiency and SIF escaping probability in the hotspot direction to the increasing incoming solar radiation. Such conclusions are supported by a variety of modeling simulations and satellite observations over various plant function types, at different time scales and with satellite observational modes. This study demonstrates the potential and advantage of normalizing SIF observations to the hotspot direction for better global GPP estimations. This study also demonstrates the great potentials of current and future spaceborne sun‐tracking satellite missions for a significant improvement in measuring and monitoring, at a wide range of spatial and temporal scales, the changes in terrestrial ecosystem GPP in response to anticipated changes in the Earth's environmental conditions.

Hao, Dalei↗

Mechanisms Regulating Deep Moist Convection and Sea-Surface Temperatures of the Tropics

Despite numerous previous studies, two relationships between deep convection and the sea-surface temperature (SST) of the tropics remain unclear. The first is the cause for the sudden emergence of deep convection at about 28 deg SST, and the second is its proximity to the highest observed SST of about 30 C. Our analysis provides a rational explanation for both by utilizing the Improved Meteorological (IMET) buoy data together with radar rainfall retrievals and atmospheric soundings provided by the Tropical Ocean Global Atmosphere Coupled Ocean-Atmosphere Response Experiment (TOGA-COARE). The explanation relies on the basic principles of moist convection as enunciated in the Arakawa-Schubert cumulus parameterization. Our analysis shows that an SST range of 28-29 C is necessary for "charging" the atmospheric boundary layer with sufficient moist static energy that can enable the towering convection to reach up to the 200 hPa level. In the IMET buoy data, the changes in surface energy fluxes associated with different rainfall amounts show that the deep convection not only reduces the solar flux into the ocean with a thick cloud cover, but it also generates downdrafts which bring significantly cooler and drier air into the boundary-layer thereby augmenting oceanic cooling by increased sensible and latent heat fluxes. In this way, the ocean seasaws between a net energy absorber for non-raining and a net energy supplier for deep-convective raining conditions. These processes produce a thermostat-like control of the SST. The data also shows that convection over the warm pool is modulated by dynamical influences of large-scale circulation embodying tropical easterly waves (with a 5-day period) and MJOs (with 40-day period); however, the quasi-permanent feature of the vertical profile of moist static energy, which is primarily maintained by the large-scale circulation and thermodynamical forcings, is vital for both the 28 C SST for deep convection and its upper limit at about 30 C.

Sud, Y. C.↗

Solar power satellite offshore rectenna study

Offshore rectennas are feasible and cost competitive with land rectennas but the type of rectenna suitable for offshore use is quite different from that specified in the present reference system. A nonground plane design minimizes the weight and greatly reduces the number of costly support towers. This perferred design is an antenna array consisting of individually encapsulated dipoles with reflectors or tagis supported on feed wires. Such a 5 GW rectenna could be built at a 50 m water depth site to withstand hurricane, winter storm, and icing conditions for a one time cost of $5.7 billion. Subsequent units would be about 1.3 less expensive. More benign and more shallow water sites would result in substantially lower costs. The major advantage of an offshore rectenna is the removal of microwave radiation from populated areas.

Source record↗

Evaluation of Ceramic Heat Exchanger for Next-Generation Concentrated Solar Power

The U.S. Department of Energy has identified a third generation of concentrated solar power (Gen3 CSP) technologies to minimize cost of CSP produced electricity. By developing these technologies further, it is forecasted that Gen3 CSP will meet the levelized cost of electricity (LCOE) SunShot target of 6 cents/kWh to compete with dominant, conventional nonrenewable energy sources (1). The focus for advancing CSP systems for Gen3 is to increase overall system efficiency. Thus, reevaluating second-generation systems, superheated steam-turbine power cycles, and implementing more advanced power cycles is essential. Specifically, it has been identified that a supercritical carbon dioxide (sCO 2 ) Brayton cycle can increase the net thermal-to-electric efficiency to over 50% for CSP power tower configurations (2). Compared to conventional superheated steam Rankine cycle systems, more extreme operating conditions are required and pose critical barriers to overcome in the field of materials and manufacturing for Gen3 CSP.

14 SOLAR ENERGY↗

Towards Erecting Straighter Lightweight Towers on the Moon Using Deployable Guy Wires

This paper reports our static stability test findings for a simple guy wire system to correct the natural lateral deflections of an 8.5m tall, compact deployable composite tower intended to support exploration of lunar permanently shadowed regions by nearby robotic assets. Deployable composite booms with microgravity flight heritage are currently being investigated at NASA Langley Research Center (LaRC) and Massachusetts Institute of Technology(MIT)’s Space Resources Workshop for their potential to be vertically deployed in the lunar gravity field, in support of NASA’s Artemis campaign. These applications include vertical solar arrays and the provision of elevated lines-of-sight to science or engineering payloads on landers and rovers, in support of nearby or distant crewed or robotic assets exploring scientifically interesting and hard to reach areas. Useful elevated payloads include radio repeaters, remote sensing and imaging, navigation and power beaming systems. However, while these lightweight booms have an excellent height to mass ratio, they typically exhibit slight axial curvature upon deployment resulting in appreciable lateral dead-load deflection of the tip mass relative to the tower base. This static deflection increases with tower height and tip mass, not only constraining the value delivered by the tower but also endangering its integrity. To develop a competitive, lightweight deployable composite boom tower, a capability to correct static deflections during and after deployment may be required. This paper presents a pathfinder deployable guy wire stability system for the MIT / LaRC self-erecting composite boom lunar tower that provides real time measurements, maintains tension passively, and can serve as a reconfigurable platform to test new guy wire components, configurations and control algorithms. Using a validated, calibrated photogrammetry system, the natural lateral deflection of the boom tip relative to the boom base at different deployed heights in Earth’s gravity field was recorded. With real-time tension measurements it was found that guy wires can significantly reduce the tip deflection of a deployable composite boom under dead load. Specifically, we found that (1) control capability is greatest where it is needed most, i.e. for the lever arm closest to being opposite the direction of deflection, and (2) for a tower height of at least 8.5 m and arm length of at least 60 cm, a solution of differential tension in all three arms exists and, in principle, provides sufficient control capability to correct or significantly reduce boom deflections. We also found that natural deflections occur almost entirely out-of-plane of the seams of the boom cross-section, which was expected, and that the natural boom tip lateral deflection under dead load upon deployment was ~5% of boom deployed length, unexpectedly exceeding the manufacturing acceptance specification of 1%.Ongoing and future collaborative work between LaRC and MIT includes the further investigation of the unexpected lateral deflection, testing of alternative guy wire system designs at higher tensions and higher deployed heights, as well as trade studies of costs and benefits of an optimized integrated guywire system compared to other types of static stability solutions.

lunar towers↗