Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid Angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Calorimetric Low-Temperature Detectors for X-Ray Spectroscopy on Trapped Highly-Charged Heavy Ions

The application of Calorimetric Low-Temperature Detectors (CLTDs) has been proposed at the Heavy-Ion TRAP facility HITRAP which is currently being installed at the Helmholtz Research Center for Heavy Ion Research GSI. This cold ion trap setup will allow the investigation of X-rays from ions practically at rest, for which the excellent energy resolution of CLTDs can be used to its full advantage. However, the relatively low intensities at HITRAP demand larger solid angles and an optimized cryogenic setup. The influence of external magnetic fields has to be taken into account. CLTDs will also be a substantial part of the instrumental equipment at the future Facility for Antiproton and Heavy Ion Research (FAIR), for which a wide variety of high-precision X-ray spectroscopy experiments has been proposed. This contribution will give an overview on the chances and challenges for the application of CLTDs at HITRAP as well as perspectives for future experiments at the FAIR facility.

Kilbourne, Caroline↗

A Tracking Sun Photometer Without Moving Parts

This innovation is small, lightweight, and consumes very little electricity as it measures the solar energy attenuated by gases and aerosol particles in the atmosphere. A Sun photometer is commonly used on the Earth's surface, as well as on aircraft, to determine the solar energy attenuated by aerosol particles in the atmosphere and their distribution of sizes. This information is used to determine the spatial and temporal distribution of gases and aerosols in the atmosphere, as well as their distribution sizes. The design for this Sun photometer uses a combination of unique optics and a charge coupled device (CCD) array to eliminate moving parts and make the instrument more reliable. It could be selfcalibrating throughout the year. Data products would be down-welling flux, the direct-diffuse flux ratio, column abundance of gas phase constituents, aerosol optical depth at multiple-wavelengths, phase functions, cloud statistics, and an estimate of the representative size of atmospheric particles. These measurements can be used to obtain an estimate of aerosol size distribution, refractive index, and particle shape. Incident light is received at a light-reflecting (inner) surface, which is a truncated paraboloid. Light arriving from a hemispheric field of view (solid angle 2 steradians) enters the reflecting optic at an entrance aperture at, or adjacent to, the focus of the paraboloid, and is captured by the optic. Most of this light is reflected from an inner surface. The light proceeds substantially parallel to the paraboloid axis, and is detected by an array detector located near an exit aperture. Each of the entrance and exit apertures is formed by the intersection of the paraboloid with a plane substantially perpendicular to the paraboloid axis. Incident (non-reflected) light from a source of limited extent (the Sun) illuminates a limited area on the detector array. Both direct and diffuse illumination may be reflected, or not reflected, before being received on the detector array. As the Sun traverses a path in the sky over some time interval, the track of the Sun can be traced on the detector array. A suitably modified Sun photometer might be used to study the dynamics of an environment on another planet or satellite with an atmosphere.

Strawa, Anthony W.↗

Surface Temperature Measurements from a Stator Vane Doublet in a Turbine Engine Afterburner Flame using Ultra-Bright Cr-Doped GdAlO3 Thermographic Phosphor

Luminescence-based surface temperature measurements from an ultra-bright Cr-doped GdAlO3 perovskite (GAP:Cr) coating were successfully conducted on an air-film-cooled stator vane doublet exposed to the afterburner flame of a J85 test engine at University of Tennessee Space Institute (UTSI). The objective of the testing at UTSI was to demonstrate that reliable thermal barrier coating (TBC) surface temperatures based on luminescence decay of a thermographic phosphor could be obtained from the surface of an actual engine component in an aggressive afterburner flame environment and to address the challenges of a highly radiant background and high velocity gases. A high-pressure turbine vane doublet from a Honeywell TECH7000 turbine engine was coated with a standard electron-beam physical vapor deposited (EB-PVD) 200-m-thick TBC composed of yttria-stabilized zirconia (YSZ) onto which a 25-m-thick GAP:Cr thermographic phosphor layer was deposited by EB-PVD. The ultra-bright broadband luminescence from the GAP:Cr thermographic phosphor is shown to offer the advantage of over an order-of-magnitude greater emission intensity compared to rare-earth-doped phosphors in the engine test environment. This higher emission intensity was shown to be very desirable for overcoming the necessarily restricted probe light collection solid angle and for achieving high signal-to-background levels. Luminescence-decay-based surface temperature measurements varied from 500 to over 1000C depending on engine operating conditions and level of air film cooling.

Eldridge, Jeffrey I.↗

A Satellite Borne Cadmium Sulfide Total Corpuscular Energy Detector

The properties of single crystals of cadmium sulfide as radiation detectors are described. It has been found possible to select crystals such that: (a) The ratio of increase of conductivity under irradiation to the rate of absorption of energy in the crystal is substantially independent of particle energy (over the examined ranges of 500 ev to 80 kev for electrons and 5 kev to 180 kev for protons) and of the magnitude of energy flux (over the range from.005 to 10 ergs/cm(sup 2 -sec); and (b) The above ration is substantially the same for protons, electrons, alpha particles, x-rays, and gamma-rays. For a driving voltage of 100 volts, typical crystal yield currents of 10(sup -7) to 10(sup- 6) amperes for each erg/cm(sup 2-sec) of energy absorbed by the crystal. The threshold of such crystal detectors (resulting from dark currents of the order of 10(sup 10 amp) is typically 10(sup -3) ergs/cm(sup 2- sec). For the selected crystals a response-temperature coefficient of -0.25% per degree centigrade is found for the temperature range -50 deg C to + 50 deg C. A description is given of a complete CdS total corpuscular energy detector for the study of geomagnetically trapped radiation by means of a satellite. The detector described has a dynamic range great than 10(sup 4), a solid angle of 10(exp -3) steradian, and a detection threshold of approximately 1 erg/cm(sup 2-sec-sterad). A similar detector employing a small magnet for the selective exclusion of electrons is also described. Noteworthy practical features of these detectors for satellite and space probe experiments are: (a) Use of bare crystals, without covering foils, in order to detect charged particles having energies as low as hundreds of electron volts. (b) Simplicity of electronic auxiliaries. (c) Compactness, lightweight and nechanical ruggedness. (d) Low electrical power requirements; and (e) Conversion of conduction current to the rate of a twostate relaxation oscillator in order to facilitate telemetric transmission of data. A pair of such detectors was flown as part of the s-46 satellite payload on March 23, 1960, but due to vehicular failure an orbit was not achieved and the operation of the CdS detectors was observed for only, six minutes of flight.

Freeman, John W.↗

The Theory of Pulsating Flow in Conical Nozzles

A knowledge of the dynamic characteristics of nozzles and orifices is important in many control and stability analyses of engineering devices. It is usual to assume that the instantaneous flow-rate, for a given set of inlet conditions and outlet pressure, is the same as the nontransient value for the same operating conditions. Recently, in connection with the stability analysis of an externally pressurized thrust bearing, the validity of this assumption was questioned. The analysis presented in this paper was undertaken to provide an answer. The present analysis applies to any fluid, liquid, or gas flowing into a simple conical nozzle. The amplitude and phase of the mass-flux response to a sinusoidally time-varying pressure fluctuation at the nozzle exit are determined. An approximate formula is given for these quantities in terms of the nozzle throat area, the solid angle subtended by the cone, the velocity of the fluid at the nozzle throat, the acoustic velocity at the throat, and the frequency of the pressure fluctuation.

Elrod, H. G., Jr.↗

DiskDetective.org: Finding Homes for Exoplanets Through Citizen Science

The Disk Detective project is scouring the data archive from the WISE all-sky survey to find new debris disks and protoplanetary disks-the dusty dens where exoplanets form and dwell. Volunteers on this citizen science website have already performed 1.6 million classifications, searching a catalog 8x the size of any published WISE survey. We follow up candidates using ground based telescopes in California, Arizona, Chile, Hawaii, and Argentina. We ultimately expect to increase the pool of known debris disks by approx. 400 and triple the solid angle in clusters of young stars examined with WISE, providing a unique new catalog of isolated disk stars, key planet-search targets, and candidate advanced extraterrestrial civilizations. Come to this talk to hear the news about our latest dusty discoveries and the trials and the ecstasy of launching a new citizen science project. Please bring your laptop or smartphone if you like!

debris disks↗

Simulation of Satellite, Airborne and Terrestrial LiDAR with DART (I):Waveform Simulation with Quasi-Monte Carlo Ray Tracing

Light Detection And Ranging (LiDAR) provides unique data on the 3-D structure of atmosphere constituents and the Earth's surface. Simulating LiDAR returns for different laser technologies and Earth scenes is fundamental for evaluating and interpreting signal and noise in LiDAR data. Different types of models are capable of simulating LiDAR waveforms of Earth surfaces. Semi-empirical and geometric models can be imprecise because they rely on simplified simulations of Earth surfaces and light interaction mechanisms. On the other hand, Monte Carlo ray tracing (MCRT) models are potentially accurate but require long computational time. Here, we present a new LiDAR waveform simulation tool that is based on the introduction of a quasi-Monte Carlo ray tracing approach in the Discrete Anisotropic Radiative Transfer (DART) model. Two new approaches, the so-called "box method" and "Ray Carlo method", are implemented to provide robust and accurate simulations of LiDAR waveforms for any landscape, atmosphere and LiDAR sensor configuration (view direction, footprint size, pulse characteristics, etc.). The box method accelerates the selection of the scattering direction of a photon in the presence of scatterers with non-invertible phase function. The Ray Carlo method brings traditional ray-tracking into MCRT simulation, which makes computational time independent of LiDAR field of view (FOV) and reception solid angle. Both methods are fast enough for simulating multi-pulse acquisition. Sensitivity studies with various landscapes and atmosphere constituents are presented, and the simulated LiDAR signals compare favorably with their associated reflectance images and Laser Vegetation Imaging Sensor (LVIS) waveforms. The LiDAR module is fully integrated into DART, enabling more detailed simulations of LiDAR sensitivity to specific scene elements (e.g., atmospheric aerosols, leaf area, branches, or topography) and sensor configuration for airborne or satellite LiDAR sensors.

Gastellu-Etchegorry, Jean-Philippe↗

Total Dose Survivability of Hubble Electronic Components

A total dose analysis for exposure of electronic parts at the box level is presented for the Hubble Space Telescope. This was done using solid angle sectoring/3-dimensional ray trace and Monte Carlo radiation transport simulations. Results are discussed in terms of parts that are potential total dose concerns.

Monte Carlo radiation transport simulation↗

SAGE III ISS Contamination Monitoring Package: Observations in Orbit

The Stratospheric Aerosol and Gas Experiment III (SAGE III) telescope and instrument assembly employ the methods of solar occultation and lunar occultation to retrieve near-global vertical profiles of atmospheric ozone, water vapor, nitrogen dioxide, aerosol extinctions, and other gaseous species and atmospheric state parameters. The SAGE III grating spectrometer measures light within the spectral range of 280 nm to 1037 nm at approximately 1 nm resolution, but retrievals in the Ultraviolet (UV) are particularly sensitive to contamination of the optical train. Therefore, a contamination door that contains a quartz optical window can be closed over the telescope aperture during periods of enhanced external contaminant flux. This optically transparent window permits continued science event acquisition at an acceptably diminished signal-to-noise ratio, which is expected to decline with ongoing accretion of contaminant material. To date, this impact has been short term, and science quality through the window returns to baseline performance after a contamination source is removed and spontaneous desorption removes material from the low-affinity quartz surface. Two Contamination Monitoring Packages (CMPs) consisting of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) from QCM Research provide characterization and redundant monitoring of contaminant deposition from the 2π steradian solid angle on the payload side of the Expedite the Processing of Experiments to the Space Station (ExPRESS) Payload Adapter. CMP data are closely examined by the SAGE III team to determine when the contamination door should remain closed during science events and in what direction the instrument assembly scan head should stow when not acquiring science measurements. Additionally, should the CMPs indicate an unacceptable accretion rate, the ight computer will close the contamination door as part of the automatic fault detection system. Along with spectrometer measurements of the quartz window's transmission, the payload CMPs enable auditing of the mission contamination budget. The process of Thermogravimetric Analysis (TGA) can be used to help identify chemical constituents accreted on the CMP sensors. To be presented here along with an explanation of the CMP systems are the first two and a half years of observations of the contaminant deposition environment around the payload in quiescence and during special events like docking vehicles.

Tyler T Dawson↗

Two-Year Cosmology Large Angular Scale Surveyor (CLASS) Observations: 40GHz Telescope Pointing, Beam Profile, Window Function, and Polarization Performance

The Cosmology Large Angular Scale Surveyor (CLASS) is a telescope array that observes the cosmic microwave background (CMB) over 75% of the sky from the Atacama Desert, Chile, at frequency bands centered near 40, 90, 150, and 220 GHz. CLASS measures the large angular scale (1°~< θ >=90°) CMB polarization to constrain the tensor-to-scalar ratio at the r ∼ 0.01 level and the optical depth to last scattering to the sample variance limit. This paper presents the optical characterization of the 40 GHz telescope during its first observation era, from 2016 September to 2018 February. High signal-to-noise observations of the Moon establish the pointing and beam calibration. The telescope boresight pointing variation is <0°. 023 (<1.6% of the beam’s full width at half maximum (FWHM)). We estimate beam parameters per detector and in aggregate, as in the CMB survey maps. The aggregate beam has an FWHM of 1°.579 ± 0°.001 and a solid angle of 838 ± 6 μsr, consistent with physical optics simulations. The corresponding beam window function has a sub-percent error per multipole at ℓ < 200. An extended 90° beam map reveals no significant far sidelobes. The observed Moon polarization shows that the instrument polarization angles are consistent with the optical model and that the temperature-to-polarization leakage fraction is <10(exp −4) (95% C.L.). We find that the Moon-based results are consistent with measurements of M42, RCW 38, and Tau A from CLASS’s CMB survey data. In particular, Tau A measurements establish degree- level precision for instrument polarization angles.

Xu, Zhilei↗

SAGE III/ISS Contamination Monitoring Package: Observations in Orbit

The Stratospheric Aerosol and Gas Experiment III (SAGE III) telescope and instrument assembly employ the methods of solar occultation and lunar occultation to retrieve near-global vertical profiles of atmospheric ozone, water vapor, nitrogen dioxide, aerosol extinctions, and other gaseous species and atmospheric state parameters. The SAGE III grating spectrometer measures light within the spectral range of 280 nm to 1037 nm at approximately 1 nm resolution, but retrievals in the Ultraviolet (UV) are particularly sensitive to contamination of the optical train. Therefore, a contamination door that contains a quartz optical window can be closed over the telescope aperture during periods of enhanced external contaminant flux. This optically transparent window permits continued science event acquisition at an acceptably diminished signal-to-noise ratio, which is expected to decline with ongoing accretion of contaminant material. To date, this impact has been short term, and science quality through the window returns to baseline performance after a contamination source is removed and spontaneous desorption removes material from the low-affinity quartz surface. Two Contamination Monitoring Packages (CMPs) consisting of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) from QCM Research provide characterization and redundant monitoring of contaminant deposition from the 2pi steradian solid angle on the payload side of the Expedite the Processing of Experiments to the Space Station (ExPRESS) Payload Adapter. CMP data are closely examined by the SAGE III team to determine when the contamination door should remain closed during science events and in what direction the instrument assembly scan head should stow when not acquiring science measurements. Additionally, should the CMPs indicate an unacceptable accretion rate, the flight computer will close the contamination door as part of the automatic fault detection system. Along with spectrometer measurements of the quartz window's transmission, the payload CMPs enable auditing of the mission contamination budget. The process of Thermogravimetric Analysis (TGA) can be used to help identify chemical constituents accreted on the CMP sensors. To be presented here along with an explanation of the CMP systems are the first two and a half years of observations of the contaminant deposition environment around the payload in quiescence and during special events like docking vehicles.

Tyler T Dawson↗

Statistical Error Analysis on White-Light Filter Ratio Experiments to Measure Electron Parameters

The Filter ratio technique to remotely measure electron temperature and speed using four color filters in visible light and a polarization camera was described in detail in four articles by Reginald et al., Solar physics, (2018, 2019a, 2019b, 2020). In these four articles we quantified the systematic error associated with using models of symmetric corona to interpret results from asymmetric corona. We also showed the criteria applied to select the bandwidths of filters, and the pros and cons of replacing the traditional linear polarizer with a polarization camera to measure pB. What started in 1990s as ground experiments conducted during total solar eclipses that lasted for a few minutes lead to a balloon borne experiment lasting eight hours in 2019 and will blossom into a space experiment on the International Space Station in 2023. Due to constraints on the bandwidths of the four filters, a successful mission requires quantification of the statistical error using Monte Carlo simulation to generate two feasibility profiles, which are unique to the design parameters of the coronagraph, to comprehend the feasibility to measure temperature and speed within the desired temporal and spatial resolutions. For the statistical error analysis, we use modeled K and F corona profiles, representative theoretical diffraction, scattering, and vignetting profiles, assumed efficiencies for lenses, mirrors, and polarizers, assumed detector properties on quantum efficiency, full well depth, dark noise, and read noise, and assumed instrument properties on aperture diameter, solid angle, and pixel resolution. We hope future white-light coronagraphs will exhibit capabilities to measure electron density, temperature, and speed.

Nelson Reginald↗

Radiometric Performance Characterization of the CubeSat Infrared Atmospheric Sounder (CIRAS) High Operating Temperature-Barrier Infrared Detectors (HOT-BIRD))

The CubeSat Infrared Atmospheric Sounder (CIRAS) is a remote sensing instrument under development for thedemonstration and technology maturation of hyperspectral infrared sounding in a 6U CubeSat. The CIRASinstrument utilizes a 2D Focal Plane Array (FPA) of High Operating Temperature-Barrier Infrared Detectors(HOT-BIRD). The HOT-BIRD material provides improved uniformity, higher allowable operating temperatures,and lower 1/f noise. The performance of the HOT-BIRD FPA was tested inside a Integrated Dewarand Cryocooler Assembly (IDCA), allowing the operating temperature of the FPA to reach low temperatures.Experimentation involved using an external Blackbody Calibrator Target (BCT) to generate numerous imagesof the BCT object at varying scene temperatures. The data acquired was compared to a radiometric model tocharacterize the responsivity of the detectors. In addition, a solid angle correction was developed to improve theaccuracy of the modeling. Real and synthetic images are presented in the comparative analysis to validate theexpected responsivity of the detectors through calculation of the quantum efficency.

Rafol, Sir B.↗

Sputtering of Surfaces by Ion Irradiation: A Comparison of Molecular Dynamics and Binary Collision Approximation Models to Laboratory Measurements

We compare various sputtering simulation methods to experimental results in both the low energy (<1 keV) and high energy (≥1 keV) impact regimes for argon ions impacting a pure copper substrate at normal incidence. Our results indicate that for high energy impacts, both binary collision approximation (BCA) and molecular dynamics methods can be used to generate reasonable predictions for the yield and energy distribution of the sputtered atoms. We also find reasonable agreement between the theoretical and experimental results down to impact energies of 600 eV. However, at 200 eV impact energies, significant discrepancies appear between the experimental and theoretical ejecta energy distributions in the peak position, the width of the energy distribution, and the magnitude of the high energy tail. These discrepancies appear to arise from the experimental results being only for atoms sputtered normal to the substrate surface, whereas the theoretical results are integrated over all 2π solid angles above the surface. Using the BCA code SDTrimSP and limiting the results to only atoms emitted within ±15° of the surface normal brings theory and experiment into reasonable agreement. These results suggest that for low energy impacts, the energy distribution of sputtered atoms is highly dependent on the emission angle of the ejecta.

Solar wind↗

New Features of the NEQAIR Radiation Code

The longest-lived code for predicting shock layer radiation, NEQAIR, is now in its 5th decade of service. Substantial changes to the code have been made over the previous decade, the most recent report of which was at the 5th Workshop on Radiation in High Temperature Gases in 2014, for the version referred to as NEQAIR14. This paper will review some of the improvements made to the NEQAIR code since then, which is now at v15.2. Some of these features are discussed briefly below. NEQAIR15 and subsequent versions have enabled parallel evaluation of multiple lines of sight. This is accomplished by utilizing the HDF5 file format and placing multiple lines into a single file, LOS.h5, which is used for both input and output. This approach enables straightforward parallel execution both over the number of lines of sight and the number of points per line. For large problems, runtime reduces linearly with the number of nodes deployed since each line is processed independently by a subset of MPI ranks. Three applications of the multi-line solver are discussed. The first has to do with performing loosely coupled radiation-flowfield solutions. In this case the computed absorption and emission coefficients are used to evaluate the total energy absorbed or emitted at each point, allowing evaluation of the volumetric source term in the flowfield. The second computation is for obtaining heat flux from nonuniform flows, which require integration over spherical co-ordinates. These are of particular interest for evaluating radiation on the vehicle backshell. This 3D option improves the angular integration scheme and allows adaptive line selection that together reduce the number of lines required by about an order of magnitude. The final application is for remote observation, which is essentially the 3D integration problem over a small solid angle. For all three of these computations, data can be stored in the HDF5 file which allows a NEQAIR run to be restarted when it times out, or to add atmospheric absorption or instrument scan functions. An additional level of parallelism is enabled in NEQAIR15.2 using GPU routines. The GPU parallelism has realized up to 8x speed-up when running on a single core but diminishes as CPU parallelism is increased. For running multi-line simulations, it may be easier to reserve a large number of CPU nodes than to obtain the number of GPU nodes required for similar performance. A GUI, known as NEQTPY, allows for reading and creating input files, running NEQAIR, and displaying results. A significant feature of NEQTPY is the ability to perform spectral fits to data. The fits can operate on a single line spectrum (radiance vs. wavelength) or a 3D input file with multiple columns of data. Other new features include improved constants, additional species, more detailed non-Boltzmann modelling, advanced user controls, the ability to read and calculate spectra from HITRAN datafiles, photodissociation and photoionization cross-sections. A “fast” automatic grid option may reduce the size and time of spectral calculations while still maintaining good accuracy for total heat flux.

Brett A Cruden↗

HaloSat – A CubeSat that Studied the Hot Galactic Halo

HaloSat was the first CubeSat competitively funded by NASA's Astrophysics Division. HaloSat surveyed the sky in the soft (0.4-2 keV) band with the goal of studying diffuse X-ray emission from highly ionized oxygen in the circumgalactic medium (CGM) of the Milky Way (MW). The HaloSat science instrument (shown above ) contained three nominally identical X-ray detectors. The field of view had full response over a 10° diameter, tapering to zero response at 14° diameter. The detectors were sensitive in the 0.4-7 keV band. Typical halo spectra are shown below. The figure of merit for observing diffuse emission, survey grasp, is the product of effective area and solid angle of the field of view, AΩ. HaloSat has a small effective area, but a large field of view, giving it a grasp competitive with major missions. HaloSat’s grasp (17.6 cm 2 deg 2 at 600 eV) was larger than Chandra’s at launch (8.7 cm 2 deg 2 ). HaloSat data are archived at the HEASARC by a collaboration between NASA/MSFC, UI, and GSFC. See poster 104.01 by Jesse Bluem for details. HaloSat was built and operated by the University of Iowa (UI), NASA/GSFC, Johns Hopkins University, the Laboratoire Atmosphères, Observations Spatiales (LATMOS), and Blue Canyon Technologies.

HaloSat↗

PIONEER: Studies of Rare Pion Decays

A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/\mu}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/\mu}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$\pi$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hand Calculations for Nuclear Criticality Safety – Primer Revision

The document “ Hand Calculation Methods for Criticality Safety – A Primer, ” was published by the authors (Los Alamos National Laboratory report LA-14244-M) in December 2006 to provide an overview of the most common hand calculation methods used for criticality safety analysis. Hand calculation methods can be used as a starting point for more advanced calculations, and in many circumstances, they can provide sensitivity and perturbation information quicker than using a criticality code, such as KENO or MCNP. This report has been revised to augment existing basis information and example problems for each of the methods discussed: 1-group and modified 1- group diffusion theory, core-density conversions, buckling conversions, limiting surface density method, density analog method, surface density method, and solid angle method. This primer discusses the applicability of the various methods, illustrates how they are used, and provides an interpretation of the example problem results. The example problems provided are simple, practical problems, and the reference data to solve each example problem is provided. This paper will provide an overview of the Primer revision and how it can be useful for new Nuclear Criticality Safety practitioners.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗