Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid state detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Thruster momentum transfer studies and magnetoplasmadynamic (MPD) thruster use in materials/surface modification

This research project involves the systematic study of the MPD thruster for dual uses. Though it was designed as a thruster for space vehicles, the characteristics of the plasma make it an excellent candidate for industrial applications. This project will seek to characterize the system for use in materials processing and characterization. Crystals grown at Fisk University for use with solid state detectors will be studied. Surface modification on ZnCdTe, CdTe, and ZnTe will be studied using AFM, XPS and SAES. In addition to the surface modification studies, design work on a momentum transfer measurement device has been completed. The design and limitations of the device will be presented.

Thompson, E.↗

The abundances of major elements in Cas A and Tycho supernova remnants

The objective of this program was to map the abundances of major elements such as O, Si, S, and Fe in the supernova remnants, Tycho and Cas A. The approach was based upon using archival cosmic X-ray data from several space missions, notably, the Einstein Observatory, EXOSAT, ROSAT, BBSRT, and ASCA. Two of the missions, Einstein and ROSAT, had high resolution telescopes that provided excellent images, but no spectral information. Two missions with much poorer resolution telescopes, BBXRT and ASCA, gave good spectral information through pulse height of signals in their cooled solid state detector, but rather crude spatial information. Our goal was to extract spectral information from the combined analysis of the Einstein and ROSAT images of Cas A and Tycho and to verify or refine the spectral map by checking its agreement with the BBSRT or ASCA spectra results for larger regions. In particular, we note that the Einstein and ROSAT telescopes have different spectral responses. The Einstein bandwidth includes the 2-4 keV region which is absent from ROSAT. Hence, by forming linear combinations of the Einstein and ROSAT images, we are able to resolve the contributions of the 0.5-2 keV band from the 2-4 keV band. The former contains lines of O and Fe while the latter is dominated by Si and S. We correct for the expansion that has taken place in the remnants during the ten-year interval between the Einstein and ROSAT measurements, but we must assume that no significant spectral changes have occurred during that time. The analysis of the Tycho SNR was completed and the results have been published. A copy of the paper is included. The analysis of Cas A has proved to be more complicated. It is continuing with support from another program. Part of the problem may be due to difficulties in the aspect information which is needed to precisely register the ROSAT and Einstein images.

Gorenstein, P.↗

Portable, solid state, fiber optic coupled Doppler interferometer system for detonation and shock diagnostics

VISAR (Velocity Interferometer System for Any Reflector) is a specialized Doppler interferometer system that is gaining world-wide acceptance as the standard for shock phenomena analysis. The VISAR's large power and cooling requirements, and the sensitive and complex nature of the interferometer cavity have restricted the traditional system to the laboratory. This paper describes the new portable VISAR, its peripheral sensors, and the role it played in optically measuring ground shock of and underground nuclear detonation. The Solid State VISAR uses a prototype diode pumped Nd:YAG laser and solid state detectors that provide a suitcase-size system with low power requirements. A special window and sensors were developed for fiber optic coupling (1 kilometer long) to the VISAR. The system has proven itself as a reliable, easy to use instrument that is capable of field test use and rapid data reduction using only a notebook personal computer (PC).

Fleming, K. J.↗

Energy measurement of electron beams by Compton scattering

A method has been proposed to utilize the well-known Compton scattering process as a tool to measure the centroid energy of a high energy electron beam at the 0.01% level. It is suggested to use the Compton scattering of an infrared laser off the electron beam, and then to measure the energy of the scattered gamma-rays very precisely using solid-state detectors. The technique proposed is applicable for electron beams with energies from 200 MeV to 16 GeV using presently available lasers. This technique was judged to be the most viable of all those proposed for beam energy measurements at the nearby Continuous Electron Beam Accelerator Facility (CEBAF). Plans for a prototype test of the technique are underway, where the main issues are the possible photon backgrounds associated with an electron accelerator and the electron and laser beam stabilities and diagnostics. The bulk of my ASEE summer research has been spent utilizing the expertise of the staff at the Aerospace Electronics Systems Division at LaRC to assist in the design of the test. Investigations were made regarding window and mirror transmission and radiation damage issues, remote movement of elements in ultra-high vacuum conditions, etc. The prototype test of the proposed laser backscattering method is planned for this December.

Keppel, Cynthia↗

Catholic University Co-Operative Agreement

R. Starr is the leader of the science team for the X-Ray Spectrometer (XRS) which will fly on-board the SSTI Clark satellite. This XRS will fly small room-temperature, solid-state detectors that have never been flown in space before. In addition to testing this new technology, this instrument is designed to detect X-rays from solar flares and gamma-ray bursts in the energy region from about 1 keV to 100 keV. The XRS has been through environmental testing and has been integrated to the spacecraft. The Clark spacecraft is scheduled to be launched in August 1998 and the XRS will collect data in orbit continuously for the next three years.

Werntz, Carl↗

Uses of continuum radiation in the AXAF calibration

X-ray calibration of the Advanced X-ray Astrophysics Facility (AXAF) observatory at the MSFC X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis.

Kolodziejczak, J. J.↗

Uses of Continuum Radiation in the AXAF Calibration

X-ray calibration of the Advanced X-ray Astrophysics Facility (AXAF) observatory at the MSFC X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis.

Kolodziejczak, J. J.↗

Progress in Using Continuum radiation for AXAF Calibration

X-ray calibration of the AXAF observatory at MSFC's X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis. Further verification of AXAF response models will be presented.

Kolodziejczak, J. J.↗

Solar Particle Induced Upsets in the TDRS-1 Attitude Control System RAM During the October 1989 Solar Particle Events

The three large solar particle events, beginning on October 19, 1989 and lasting approximately six days, were characterized by high fluences of solar protons and heavy ions at 1 AU. During these events, an abnormally large number of upsets (243) were observed in the random access memory of the attitude control system (ACS) control processing electronics (CPE) on-board the geosynchronous TDRS-1 (Telemetry and Data Relay Satellite). The RAM unit affected was composed of eight Fairchild 93L422 memory chips. The Galileo spacecraft, launched on October 18, 1989 (one day prior to the solar particle events) observed the fluxes of heavy ions experienced by TDRS-1. Two solid-state detector telescopes on-board Galileo, designed to measure heavy ion species and energy, were turned on during time periods within each of the three separate events. The heavy ion data have been modeled and the time history of the events reconstructed to estimate heavy ion fluences. These fluences were converted to effective LET spectra after transport through the estimated shielding distribution around the TDRS-1 ACS system. The number of single event upsets (SEU) expected was calculated by integrating the measured cross section for the Fairchild 93L422 memory chip with average effective LET spectrum. The expected number of heavy ion induced SEU's calculated was 176. GOES-7 proton data, observed during the solar particle events, were used to estimate the number of proton-induced SEU's by integrating the proton fluence spectrum incident on the memory chips, with the two-parameter Bendel cross section for proton SEU'S. The proton fluence spectrum at the device level was gotten by transporting the protons through the estimated shielding distribution. The number of calculated proton-induced SEU's was 72, yielding a total of 248 predicted SEU'S, very dose to the 243 observed SEU'S. These calculations uniquely demonstrate the roles that solar heavy ions and protons played in the production of SEU's during the October 1989 solar particle events.

Croley, D. R.↗

Energetic Neutral Atom Imager on the Swedish Microsatellite Astrid

The Swedish microsatellite ASTRID was launched by a Russian Cosmos rocket on January 24, 1995 into a 1000 km circular orbit with 83 deg inclination. Besides the main objective of technological demonstration, imaging of energetic neutral atoms (ENAS) was attempted. The imager detected ENA in the energy range 0.1 - 140 keV utilizing two different techniques. Neutrals of the energy 13 - 140 keV were recorded by 14 solid state detectors with the total field of view 5 deg x 322 deg. For half a spin (approx. 1.5 s) of the ASTRID spacecraft, almost all of space was covered with an angular resolution 2.5 deg x 25 deg. Less energetic neutrals of approx. 0.1 - 70 keV were converted on a graphite target into secondary particles which then were detected by a microchannel plate with 32 anodes. A fraction of primary neutrals was directly reflected towards the sensor. This technique provided the total ENA flux with an angular resolution 4.6 deg x 11.5 deg. The instrument weight is 3.13 kg. Successful operation of the instrument during the first 5 weeks of the mission provided the first ENA images of the ring current at low altitudes.

Barabash, S.↗

Gamma Ray Astronomy

The project has progressed successfully during this period of performance. The highlights of the Gamma Ray Astronomy teams efforts are: (1) Support daily BATSE data operations, including receipt, archival and dissemination of data, quick-look science analysis, rapid gamma-ray burst and transient monitoring and response efforts, instrument state-of-health monitoring, and instrument commanding and configuration; (2) On-going scientific analysis, including production and maintenance of gamma-ray burst, pulsed source and occultation source catalogs, gamma-ray burst spectroscopy, studies of the properties of pulsars and black holes, and long-term monitoring of hard x-ray sources; (3) Maintenance and continuous improvement of BATSE instrument response and calibration data bases; (4) Investigation of the use of solid state detectors for eventual application and instrument to perform all sky monitoring of X-Ray and Gamma sources with high sensitivity; and (5) Support of BATSE outreach activities, including seminars, colloquia and World Wide Web pages. The highlights of this efforts can be summarized in the publications and presentation list.

Wu, S. T.↗

Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment

During grant NAG5-5064, Louisiana State University (LSU) led the ATIC team in the development, construction, testing, accelerator validation, pre-deployment integration and flight operations of the Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment. This involved interfacing among the ATIC collaborators (UMD, NRL/MSFC, SU, MSU, WI, SNU) to develop a new balloon payload based upon a fully active calorimeter, a carbon target, a scintillator strip hodoscope and a pixilated silicon solid state detector for a detailed investigation of the very high energy cosmic rays to energies beyond 10(exp 14) eV/nucleus. It is in this very high energy region that theory predicts changes in composition and energy spectra related to the Supernova Remnant Acceleration model for cosmic rays below the "knee" in the all-particle spectrum. This report provides a documentation list, details the anticipated ATIC science return, describes the particle detection principles on which the experiment is based, summarizes the simulation results for the system, describes the validation work at the CERN SPS accelerator and details the balloon flight configuration. The ATIC experiment had a very successful LDB flight from McMurdo, Antarctica in 12/00 - 1/01. The instrument performed well for the entire 15 days. Preliminary data analysis shows acceptable charge resolution and an all-particle power law energy deposition distribution not inconsistent with previous measurements. Detailed analysis is underway and will result in new data on the cosmic ray charge and energy spectra in the GeV - TeV energy range. ATIC is currently being refurbished in anticipation of another LDB flight in the 2002-03 period.

Wefel, John P.↗

Response of a tissue equivalent proportional counter to neutrons

The absorbed dose as a function of lineal energy was measured at the CERN-EC Reference-field Facility (CERF) using a 512-channel tissue equivalent proportional counter (TEPC), and neutron dose equivalent response evaluated. Although there are some differences, the measured dose equivalent is in agreement with that measured by the 16-channel HANDI tissue equivalent counter. Comparison of TEPC measurements with those made by a silicon solid-state detector for low linear energy transfer particles produced by the same beam, is presented. The measurements show that about 4% of dose equivalent is delivered by particles heavier than protons generated in the conducting tissue equivalent plastic. c2002 Elsevier Science Ltd. All rights reserved.

NASA Center JSC↗

Analysis of the pre-flight and post-flight calibration procedures performed on the Liulin space radiation dosimeter

Liulin, a dosimetry-radiometry system, was developed to satisfy the requirements for active flux and dose rate measurements for the flight of the second Bulgarian cosmonaut in 1988. The system consists of a compact battery-operated silicon solid state detector unit and a read/write microcomputer and telemetry unit. We describe the pre-flight calibrations with charged particles, using radioactive sources and accelerated 170 MeV/nucleon proton and alpha particles at the Dubna, Russia cyclotron. We discuss comparisons with data obtained on Mir with the French-built tissue equivalent LET spectrometer NAUSICAA. Lastly, we describe post-flight calibrations performed with 1 GeV/nucleon 56Fe ions at the Brookhaven National Laboratory AGS accelerator, where the instrument was mounted in tandem with several thin position-sensitive silicon detectors behind a stopping target. The silicon detectors provided an energy spectrum for the surviving charged nuclear fragments for which the flux and absorbed dose were recorded by Liulin.

long duration↗

A Lidar for Making Range Resolved CO2 Measurements within the Planetary Boundary Layer

A ground based differential absorption lidar is under development at NASA's Goddard Space Flight Center to make range resolved measurements of CO2 within the planetary boundary layer. This is a direct detection lidar designed for both photon counting and analog use. Technology being developed for this instrument will be discussed including efforts in fiber lasers, optical parametric amplifiers and both InGaAs and HgCdTe solid-state detectors. The capabilities of this system are investigated and preliminary results presented.

Burris, John↗

High Resolution, Non-Dispersive X-Ray Calorimeter Spectrometers on EBITs and Orbiting Observatories

X-ray spectroscopy is the primary tool for performing atomic physics with Electron beam ion trap (EBITs). X-ray instruments have generally fallen into two general categories, 1) dispersive instruments with very high spectral resolving powers but limited spectral range, limited count rates, and require an entrance slit, generally, for EBITs, defined by the electron beam itself, and 2) non-dispersive solid-state detectors with much lower spectral resolving powers but that have a broad dynamic range, high count rate ability and do not require a slit. Both of these approaches have compromises that limit the type and efficiency of measurements that can be performed. In 1984 NASA initiated a program to produce a non-dispersive instrument with high spectral resolving power for x-ray astrophysics based on the cryogenic x-ray calorimeter. This program produced the XRS non-dispersive spectrometers on the Astro-E, Astro-E2 (Suzaku) orbiting observatories, the SXS instrument on the Astro-H observatory, and the planned XMS instrument on the International X-ray Observatory. Complimenting these spaceflight programs, a permanent high-resolution x-ray calorimeter spectrometer, the XRS/EBIT, was installed on the LLNL EBIT in 2000. This unique instrument was upgraded to a spectral resolving power of 1000 at 6 keV in 2003 and replaced by a nearly autonomous production-class spectrometer, the EBIT Calorimeter Spectrometer (ECS), in 2007. The ECS spectrometer has a simultaneous bandpass from 0.07 to over 100 keV with a spectral resolving power of 1300 at 6 keV with unit quantum efficiency, and 1900 at 60 keV with a quantum efficiency of 30%. X-ray calorimeters are event based, single photon spectrometers with event time tagging to better than 10 us. We are currently developing a follow-on instrument based on a newer generation of x-ray calorimeters with a spectral resolving power of 3000 at 6 keV, and improved timing and measurement cadence. The unique capabilities of the x-ray calorimeter spectrometer, coupled with higher spectral resolution dispersive spectrometers to resolve line blends, has enabled many science investigations, to date mostly in our x-ray laboratory astrophysics program. These include measurements of absolute cross sections for Land K shell emission from Fe and Ni, charge exchange measurements in many astrophysically abundant elements, lifetime measurements, line ratios, and wavelength measurements. In addition, we have performed many additional measurements in nuclear physics, and in support of diagnostics for laser fusion, for example. In this presentation we will give a detailed overview of x-ray calorimeter instruments in general and in our EBIT laboratory astrophysics program in particular. We will also discuss the science yield of our measurements at EBIT over the last decade) prospects for future science enabled by the current generation of spectrometers and that will be expanded in the near future by the next generation of spectrometers starting in 2611.

Porter, Frederick S.↗

Highlights from 40 Years of Satellite UV Measurements

This year we are celebrating the 40th anniversary of the launch of the Backscatter Ultraviolet (BUV) instrument on NASA's Nimbus-4 satellite. The purpose of this instrument was to demonstrate the capability to measure total column ozone and its vertical distribution from space. The success of this instrument led to about a dozen instruments of this type on various NASA and NOAA satellites. These instruments used a single photomultiplier tube (PMT) that restricted the measurements to 6-12 discrete wavelengths in the 250-380 nm range. With the availability of solid-state detector arrays in the past decade it has been possible to make similar measurements but with hyperspectral (contiguous in wavelength) sampling and enhanced spectral resolution. This has allowed global mapping of several weakly-absorbing trace gases including S0 2, NO2, BrO, HCHO, and CIIOCHO. Since these measurements are affected by clouds and aerosols, a great deal of effort has gone into understanding their effect on ultraviolet radiation- both upwelling and downwelling. The downwelling UV radiation is chemically and biologically active and has both negative (genetic damage, air pollution) and positive (production of vitamin D and OH radical) environmental effects. I will discuss how the interaction of Rayleigh-scattered UV radiation with clouds and aerosols produce a variety of interesting effects that are leading to new methods of remote sensing of their properties. The UV measurements can greatly enhance the information that one derives from more traditional methods that use infrared and visible part of the solar spectrum.

Bhartia, Pawan K.↗