Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid state detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Prospects for Machine Learning and Pulse Shaping on the Scorpius Accelerator [Poster]

The Advanced Sources and Detectors (ASD) project aims to build Scorpius, a multi pulse linear induction accelerator capable of delivering a 1.4 kA electron beam at energies up to 24 MeV. One of the primary advancements of Scorpius is the use of solid state pulsed power (SSPP) to provide flexibility in pulse shaping by independently triggering 45 individual stages stacked in each of 984 line replaceable units (LRU), with 168 LRUs dedicated to the injector. By leveraging circuit modeling of each LRU stage, a machine learning model of the SSPP will be developed to allow for optimization of the pulse shape, including pulse flattening and reflection mitigation. Particle-in-cell simulations of Scorpius have, for example, demonstrated that reducing reflections during multi-pulse operation mitigates beam spill by preventing the production of off-energy electrons between pulses, thereby abating stimulated ion desorption from the wall and beam charge neutralization. This machine learning model will be validated and tuned with experimental data collected from the Scorpius injector and Integrated Test Stand

43 PARTICLE ACCELERATORS↗

Development of selenium imaging detectors toward a definitive search for neutrinoless ββ decay

Imaging sensors made from an ionization target layer of amorphous selenium (aSe) coupled to a silicon complementary metal-oxide-semiconductor (CMOS) active pixel array for charge readout are a promising technology for neutrino physics. The high spatial resolution in a solid-state target provides unparalleled rejection of backgrounds from natural radioactivity in the search for the neutrinoless ββ decay of 82 Se. With this grant, we experimentally determined two crucial factors necessary for the realization of this novel technology: i) the intrinsic energy response of aSe to ionizing electrons, and ii) the feasibility to couple a target layer of aSe to a CMOS active pixel sensor to image electron tracks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coloring Tetrahedral Semiconductors: Synthesis and Photoluminescence Enhancement of Ternary II-III 2 -VI 4 Colloidal Nanocrystals

Ternary tetrahedral II-III 2 -VI 4 semiconductors, where II is Zn or Cd, III In or Ga, and VI S, Se, or Te, are of interest in UV radiation detectors in medicine and space physics as well as CO 2 photoreduction under visible light. We synthesize colloidal II-III 2 -VI 4 semiconductor nanocrystals from readily available precursors and ascertain their ternary nature by structural and spectroscopic methods, including 77 Se solid-state NMR spectroscopy. The pyramidally shaped nanocrystals range between 2 and 12 nm and exhibit optical gaps of 2–3.9 eV. In the presence of excess anions on the particle surface, treatment with Lewis acidic, Z-type ligands results in better passivation and enhanced photoluminescence. Electronic structure calculations reveal the most stable, lowest energy polymorphs and coloring patterns. This work will pave the way toward more environmentally friendly, ternary semiconductors for optoelectronics and electrocatalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PIONEER: Studies of Rare Pion Decays

A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/\mu}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/\mu}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$\pi$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-current-heating devices to study in situ phase formation in metallic glasses by using high-energy synchrotron radiation

Details of fast-resistive-heating setups, controlled heating ranging from ~10 1 K s –1 to ~10 3 K s –1 , to study in situ phase transformations (on heating and on cooling) in metallic glasses by high-energy synchrotron x-ray diffraction are discussed here. Both setups were designed and custom built at the Leibniz Institute for Solid State and Materials Research Dresden (IFW Dresden) and have been implemented at the P02.1 Powder Diffraction and Total Scattering Beamline and the P21.1 Swedish Materials Science Beamline at PETRA III storage ring, DESY, Hamburg. The devices are interchangeable at both beamlines. Joule heating is triggered automatically and is timed with the incident beam and detector. The crystallization process can be controlled via a feedback circuit by monitoring the change in the time-dependent resistivity and temperature of glasses. Different ambient atmospheres, such as vacuum and inert gases (He and Ar), can be used to control oxidation and cooling. The main focus of these devices is on understanding the crystallization mechanism and kinetics in metallic glasses, which are brittle and for which fast heating gives defined glass–crystal composites with enhanced plasticity. As an example, phase-transformation sequence(s) in a prototyped Cu–Zr-based metallic glass is described on heating, and a crystalline phase beneficial to the plasticity is identified.

47 OTHER INSTRUMENTATION↗

Ultrahigh‐Flux X‐ray Detection by a Solution‐Grown Perovskite CsPbBr 3 Single‐Crystal Semiconductor Detector

Abstract Solution‐processed perovskites are promising for hard X‐ray and gamma‐ray detection, but there are limited reports on their performance under extremely intense X‐rays. Here, a solution‐grown all‐inorganic perovskite CsPbBr 3 single‐crystal semiconductor detector capable of operating at ultrahigh X‐ray flux of 10 10 photons s −1 mm −2 is reported. High‐quality solution‐grown CsPbBr 3 single crystals are fabricated into detectors with a Schottky diode structure of eutectic gallium indium/CsPbBr 3 /Au. A high reverse‐bias voltage of 1000 V (435 V mm − 1 ) can be applied with a small and stable dark current of ≈60–70 nA (≈9–10 nA mm − 2 ), which enables a high sensitivity larger than 10 000 µC Gy air −1 cm − 2 and a simultaneous low detection limit of 22 nGy air s − 1 . The CsPbBr 3 semiconductor detector shows an excellent photocurrent linearity and reproducibility under 58.61 keV synchrotron X‐rays with flux from 10 6 to 10 10 photons s − 1 mm − 2 . Defect characterization by thermally stimulated current spectroscopy shows a similar low defect density of a synchrotron X‐ray and a lab X‐ray irradiated device. Solid‐state nuclear magnetic resonance spectroscopy suggests that the excellent performance of the solution‐grown CsPbBr 3 single crystal may be associated with its good short‐range order, comparable to the spectrometer‐grade melt‐grown CsPbBr 3 .

Pan, Lei↗

Automated microbial detection and quantification

A method for automated microbial detection includes collecting air particles into a solid-state sampler, the air particles including microbes, charging the air particles using a plasma field generated by propulsion electrodes, focusing the charged air particles toward a sample well of a microfluidic testing cartridge, tagging the charged air particles with a fluorescence marker, and detecting a quantity of the microbes using a fluorescence detector.

Gilbert, James H.↗

First-ever deployment of a SiPM-on-tile calorimeter in a collider: a parasitic test with 200 GeV p p collisions at RHIC.

We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV p p run in 2024. The prototype, measuring 20 × 20 cm 2 and 24 radiation lengths in depth, was positioned in the STAR experimental hall, approximately 8 m from the interaction point and 65 cm from the beam line, covering a pseudorapidity range of about 3.1 < η < 3.4. By using the dark current of a reference SiPM as a radiation monitor, we estimate that the prototype was exposed to a fluence of about 10 10 1-MeV n eq /cm 2 . Channel-by-channel calibration was performed in a data-driven way with the signature from minimum-ionizing particles during beam-on conditions. AGeant4 detector simulation, with inputs from thePythia8 event generator, describes measurements of energy spectra and hit multiplicities reasonably well. These results mark the first deployment, commissioning, calibration, and long-term operation of a SiPM-on-tile calorimeter in a collider environment. This experimental campaign will guide detector designs and operational strategies for the ePIC detector at the future EIC, as well as other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Introducing new resonant soft x-ray scattering capability in SSRL

Resonant soft x-ray scattering (RSXS) is a powerful technique for probing both spatial and electronic structures within solid-state systems. Here, we present a newly developed RSXS capability at beamline 13-3 of the Stanford Synchrotron Radiation Lightsource, designed to enhance materials science research. This advanced setup achieves a base sample temperature as low as 9.8 K combined with extensive angular motions (azimuthal ϕ and flipping χ), enabling comprehensive exploration of reciprocal space. Two types of detectors—an Au/GaAsP Schottky photodiode and a charge-coupled device detector with over 95% quantum efficiency—are integrated to effectively capture scattered photons. Extensive testing has confirmed the enhanced functionality of this RSXS setup, including its temperature and angular performance. The versatility and effectiveness of the system have been demonstrated through studies of various materials, including superlattice heterostructures and high-temperature superconductors.

Kuo, Cheng-Tai [SLAC National Accelerator Laborato↗

High-resolution 3D-printed plastic scintillators with tertiary dye

Additive manufacturing offers efficient production of plastic scintillators with nontrivial geometries using vat polymerization, allowing fabrication of geometries which would be difficult or even impossible to produce using conventional subtractive manufacturing. This work presents a novel photocurable scintillator formula that includes coumarin 450 as a tertiary dye to enable high-resolution 3D printing via the manipulation of the 405 nm cure light. Bulk photocured and 3D printed (with and without tertiary dye) samples were compared through observational assessment and spectral response. All samples showed pulse shape discrimination between neutron and gamma events. Inclusion of the tertiary dye has minimal impact on emission spectrum and light output, but significant impact on print resolution as shown by comparison of printed high-complexity geometries and feature resolution test objects. With the use of a cure-limiting dye, unsupported features — such as freestanding pillars — were resolvable down to 0.7 mm. Even finer resolution at or below 0.1 mm was achieved in fully supported, integrated structures printed with off-the-shelf 405 nm desktop 3D printer. Scintillators demonstrated a light output up to 50% of EJ-200 with a PSD figure of merit up to 1.35 at 0.9–1.1 MeVee.

36 MATERIALS SCIENCE↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Splitting phonons: Building a platform for linear mechanical quantum computing

Linear optical quantum computing provides a desirable approach to quantum computing, with only a short list of required computational elements. The similarity between photons and phonons points to the interesting potential for linear mechanical quantum computing using phonons in place of photons. Although single-phonon sources and detectors have been demonstrated, a phononic beam splitter element remains an outstanding requirement. Here we demonstrate such an element, using two superconducting qubits to fully characterize a beam splitter with single phonons. We further use the beam splitter to demonstrate two-phonon interference, a requirement for two-qubit gates in linear computing. In conclusion, this advances a new solid-state system for implementing linear quantum computing, further providing straightforward conversion between itinerant phonons and superconducting qubits.

97 MATHEMATICS AND COMPUTING↗

Thermal Processing Conditions for the Synthesis of Near Theoretical Density Li 5 La 3 Ta 2 O 12 Ceramics for Ceramic Dual-Mode Detectors

A family of Li-containing garnet compounds, extensively investigated for Li-ion solid electrolyte applications, show great potential to be developed into transparent ceramic dual-mode scintillators. In particular, Li 5 La 3 Ta 2 O 12 (LLTaO) shows promise as an efficient dual-mode scintillator due to its high Li content, high density, non-hygroscopicity, and high effective-Z. Often the synthesis of LLTaO ceramics involves solid state processing techniques starting with oxide and carbonate powders, calcining, sintering for the removal of residual porosity, and post-processing. This study focuses on two objectives: (1) establishing thermal processing boundary conditions for a flexible alkoxide-based sol-gel method for synthesizing fine-grained powders; and (2), consolidating powders via hot-pressing to form high-density ceramics. In this study, near single-phase ceramics were achieved by hot-pressing sol-gel powders with varying amounts of excess Li. Rietveld refinements were used to analyze X-ray diffraction data and provide a quantitative evaluation of the phases present in the hot pressed ceramics. Some of the diffraction data showed large low angle peak asymmetry, suggesting the presence of two cubic Li 5 La 3 Ta 2 O 12 garnet phases with different lattice parameters. Depending on the synthesis and processing conditions, the refinement revealed ~ 90 wt% concentration of a phase with a ≈ 12.8 Å and ~ 10 wt% concentration of a phase with a ≈ 12.9 Å, indicating a remaining excess of Li in the hot pressed ceramics in the large lattice parameter phase. These synthesis experiments allowed for the determination of a baseline for Li loss during hot-pressing. X-ray excited radioluminescence and photoluminescence excitation and emission spectra were obtained from the hot pressed ceramics. In conclusion, the measured emission spectra featured broad tantalate emission and line emissions likely from a rare-earth impurity.

36 MATERIALS SCIENCE↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

Simultaneous Multi-Bragg Peak Coherent X-ray Diffraction Imaging

The simultaneous measurement of two Bragg reflections by Bragg coherent X-ray diffraction is demonstrated on a twinned Au crystal, which was prepared by the solid-state dewetting of a 30 nm thin gold film on a sapphire substrate. The crystal was oriented on a goniometer so that two lattice planes fulfill the Bragg condition at the same time. The Au 111 and Au 200 Bragg peaks were measured simultaneously by scanning the energy of the incident X-ray beam and recording the diffraction patterns with two two-dimensional detectors. While the former Bragg reflection is not sensitive to the twin boundary, which is oriented parallel to the crystal–substrate interface, the latter reflection is only sensitive to one part of the crystal. The volume ratio between the two parts of the twinned crystal is about 1:9, which is also confirmed by Laue microdiffraction of the same crystal. The parallel measurement of multiple Bragg reflections is essential for future in situ and operando studies, which are so far limited to either a single Bragg reflection or several in series, to facilitate the precise monitoring of both the strain field and defects during the application of external stimuli.

47 OTHER INSTRUMENTATION↗

Three-colour digital holographic microscopy based on a Mach – Zender interferometer and a solid-state RGB laser

We have developed a facility for recording colour digital holograms involving a Mach – Zender interferometer and a pulsed solid-state RGB laser, which radiates simultaneously at three wavelengths: 451, 532, and 634 nm. These wavelengths are obtained in the conversion of the radiation of a pulsed Nd{sup 3+} : YAG laser (1064 nm), which operates in the regime of intracavity parametric oscillation at a wavelength of 1570 nm, with the subsequent conversion of its frequencies to the red, green, and blue spectral regions in nonlinear KTP-crystal elements. The combination of this three-wavelength pulsed light source with the Mach – Zender interferometer provides the simultaneous recording of three spectral digital holograms with one matrix RGB radiation detector. Pulsed three-colour digital holography shows promise for the analysis of fast processes and rapidly varying colour phase objects. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗