Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat pump via charge incompressibility in a collisional magnetized multi-ion plasma

Stratification due to ion-ion friction in a magnetized multiple-ion species plasma is shown to be accompanied by a heat pump effect, identified for the first time here, transferring heat from one ion species to another as well as from one region of space to another. Here, the heat pump is produced via newly identified heating mechanisms associated with charge incompressibility and the Ettingshausen effect. Besides their academic interest, these new effects may have useful applications to plasma technologies that involve rotation or compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of Phase-Change Materials and Operating Periods on Load Shifting for Thermal Storage Heat Pumps in European Climate Zones

As the reliance on heat pumps (HPs) for space conditioning increases worldwide, ex-tensive grid strains during utility peak hours are expected. Significant research efforts focus on investigating the use of integrated thermal energy storage (TES) systems to reduce peak energy demands. Conventionally, TES systems are often integrated to store and provide either cooling or heating, but not both. In this work, a single room-temperature phase-change material (PCM)-TES was integrated for dual-mode opera-tion with an R290 air-to-water 10.5 kW (3-Ton) HP. Two PCM melting temperatures (17°C, 22°C) were assessed to investigate their impact on system performance and cost reductions for Milan, Italy (4A); Barcelona, Spain (3A); and Oslo, Norway (6A). HP and HP-TES performance maps were generated using Modelica-based transient models and co-simulated with a prototype residential building using the Spawn of En-ergyPlusTM with simple rule-based controls. Our simulations indicate that PCM-17°C provided annual cost savings at higher peak-to-off-peak cost ratios, as the demand re-duction dominated the savings potential. The recharge energy costs and requirements became more dominant at lower cost ratios, making PCM-22°C more beneficial at lower cost ratios. Finally, despite Oslo's heating-dominated climate, the utility peak hours favor cooling demand reductions, making PCM-17°C more appealing. In all cases, the cost savings potential stabilized between 4 – 10% regardless of cost ratio, suggesting that system-level component and operation control optimization is required to maximize cost savings further.

25 ENERGY STORAGE↗

An Improved Energy Deposition Model in MPACT and Explicit Heat Generation Coupling with CTF

The default energy deposition model in the CASL neutronics code MPACT assumes all fission energy is deposited locally in fuel rods. Furthermore, equilibrium delayed energy release is assumed for both steady-state and transient calculations. These approximations limit the accurate representation of the heat generation distribution in space and its variations over time, which are essential for power distribution and thermal-hydraulic coupling calculations. In this paper, an improved energy deposition model is presented in both the spatial and time domains. Spatially, the energy deposition through fission, neutron capture, and slowing-down reactions are explicitly modeled to account for the heat generation from all regions of a reactor core, and a gamma smearing scheme is developed that utilizes the gamma sources from neutron fission and capture. In the time domain, the delayed energy release is modeled by solving an additional equation of delayed heat emitters, similar to the equation of delayed neutron precursors.To allow the explicit heat generation coupling, the interfaces between MPACT and CTF were updated to transfer separate heat sources for different material regions (fuel, clad, moderator and guide tube). The results show that the distributions of the energy deposition between MPACT and MCNP agree very well for various 2-D assembly and quarter-core problems without TH feedback. The MPACT/CTF coupled calculation for the hot full power quarter-core case exhibited a reduced peak pin power by 2.3% and a reduced peak fuel centerline temperature by 17 K when using the explicit energy deposition and heat transfer. The new model also shows a maximum 100 pcm keff effect on assembly depletion problems and an increased overall energy release by 7% in a PWR reactivity-initiated accident (RIA) problem.

Liu, Yuxuan↗

Carbon dioxide capture system and method with mass transfer contactor

A carbon dioxide capture system, fluid contactor and method are disclosed. In embodiments, a gas-liquid contactor unit is disposed along a process fluid flow axis and includes a contactor network of flow diversion barriers with flow voids for movement of process fluids therebetween. A plurality of heat exchange channels are provided in the flow diversion barriers to transport a heat exchange fluid through the contactor network. A heat exchange feed channel is provided to deliver feed of the heat exchange fluid to the heat exchange channels at multiple feed locations spaced along the flow axis. At least one heat exchange bypass channel may extend beyond the multiple feed locations to deliver a portion of the feed of the heat exchange fluid to additional heat exchange channels located downstream from the multiple feed locations for the heat exchange channels.

Panaccione, Charles↗

Utilizing a Dynamic Segmentation Convolutional Neural Network for Microstructure Analysis of Additively Manufactured Superalloy 718

Additive manufacturing (AM) is revolutionizing almost all industries through the production of intricate geometries previously prohibited by cost or machinability. Ni-based superalloys form a primary alloy class for high temperature applications in the petrochemical, aerospace, and nuclear industries because of their intrinsic resistance to creep and the ability to heat treat the superalloy for high strength. Despite these attractive properties, the extreme work hardening of Ni-based superalloys makes traditional manufacturing of complex shapes difficult and thus, these alloys are an attractive target for AM. Superalloy 718 was chosen as an example superalloy because of the wide variety of precipitates that can form within its composition space from the repetitive heating and cooling cycles of the AM process. The precipitates and other microstructure features, such as grain boundaries and dislocations, will dictate the mechanical properties and thus, there is an extensive challenge to characterize the size, number density, composition, and volume fraction of each microstructural feature from AM fabrication using analytical electron microscopy. This work focused on the application of a pixel-wise classification machine learning (ML) model called a dynamic segmentation convolutional neural network (DSCNN) to identify the microstructural features of an as-fabricated additively manufactured superalloy 718.

Taller, Stephen↗

Radiative cooling and thermoregulation in the earth’s glow

Efficient passive radiative cooling of buildings requires an unimpeded view of the sky. However, vertical facades of buildings mostly see terrestrial features that become broadband-radiative heat sources in the summer and heat sinks in the winter. The resulting summertime terrestrial heat gain by buildings negates or overwhelms their narrowband longwave infrared (LWIR) radiative cooling to space, while the wintertime terrestrial heat loss causes overcooling. We show that selective LWIR emitters on vertical building facades can exploit the differential transmittance of the atmosphere toward the sky and between terrestrial objects to achieve higher summertime cooling and wintertime heating than conventionally used broadband emitters. The impact of this novel and passive thermoregulation is comparable to that of painting dark roofs white and is achievable with both novel and commonplace materials. Our findings represent new and remarkable opportunities for materials design and untapped thermoregulation of entities ranging from buildings to human bodies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Planning for cooler communities: Vacant lots as components of heat resilience in Mesa, Arizona

Vacant lots are often perceived as contributing to negative socioeconomic and environmental impacts on surrounding communities. However, they also offer opportunities for strategic interventions that promote heat resilience. This study uses a decision-scale congruence analytic approach to examine the correlation between extreme heat and community resilience in the context of vacant lots in the city of Mesa, Arizona. By identifying and analyzing over 1,200 vacant lots, we assessed spatial patterns of Community Resilience Estimates (CRE) for Heat and Body Heat Storage (BHS) to understand their correlation at the unit of analysis of vacant lots, where key decisions are made concerning land use. The results reveal a nonrandom spatial distribution of CRE for Heat and BHS across Mesa’s vacant lots. Vacant lots are disproportionately concentrated in neighborhoods with lower resilience, exacerbating heat exposure. Communities with limited access to cooling infrastructure, tree canopy, and other resources experience lowered heat resilience. A positive correlation between CRE for Heat and BHS shows that areas with higher heat exposure tend to have lower community resilience, reinforcing the need for cooling interventions. This study highlights the potential for converting vacant lots into heat-resilient, community-serving spaces. Using our findings, decision makers can identify priority areas and leverage vacant lots to mitigate heat impacts and foster community resilience.

community resilience↗

Heat Pipe Modeling with Sockeye

A presentation for the symposium "The heat pipe, the microreactor, and space" at the University of Stuttgart, Germany on March 21, 2025, on the topic of modeling heat pipes with the code Sockeye.

97 - MATHEMATICS AND COMPUTING↗

Ion-chain sympathetic cooling and gate dynamics

Sympathetic cooling is a technique often employed to mitigate motional heating in trapped-ion quantum computers. However, choosing system parameters such as number of coolants and cooling duty cycle for optimal gate performance requires evaluating trade-offs between motional errors and other slower errors such as qubit dephasing. The optimal parameters depend on cooling power, heating rate, and ion spacing in a particular system. In this study, we aim to analyze best practices for sympathetic cooling of long chains of trapped ions using analytical and computational methods. We use a case study to show that optimal cooling performance is achieved when coolants are placed at the center of the chain and provide a perturbative upper bound on the cooling limit of a mode given a particular set of cooling parameters. In addition, using computational tools, we analyze the trade-off between the number of coolant ions in a chain and the center-of-mass mode heating rate. We also show that cooling as often as possible when running a circuit is optimal when the qubit coherence time is otherwise long. These results provide a roadmap for how to choose sympathetic cooling parameters to maximize circuit performance in trapped-ion quantum computers using long chains of ions.

Cooling & trapping↗

Prioritizing urban heat adaptation infrastructure based on multiple outcomes: Comfort, health, and energy

Globally, cities face increasing extreme heat, impacting comfort, health, and energy consumption. Infrastructure-based heat adaptation strategies can improve these outcomes, but each strategy has a unique mix of benefits and drawbacks. Here, we apply an urbanized meteorological model (WRF) with the newly integrated multilayer BEP-Tree street tree model to dynamically downscale Earth System Model projections and a 3-D microclimate model (TUF-Pedestrian) to simulate the street-scale radiation environment impacting pedestrians. We evaluate the performance of five heat adaptation strategies (street trees, cool roofs, green roofs, rooftop photovoltaics (PV), and reflective pavements) during extreme heat events in three cities with contrasting background climates (Toronto, Phoenix, and Miami), under contemporary and end-of-century projected climates, based on three metrics: outdoor heat stress, air conditioning (AC) energy use, and ventilation of vehicular air pollution. No single adaptation strategy improves all three outcomes. While street trees inhibit ventilation, they reduce outdoor heat stress four times more effectively than the next best strategy via shade provision, fully offsetting heat stress increases under a high-emissions end-of-century climate scenario in all cities studied. Cool roofs and green roofs moderately reduce heat stress and energy use. Alternatively, rooftop PV with energy storage can generate sufficient power for space cooling but have marginal effects on heat stress. Reflective pavements are the least effective across metrics. Where the ventilation of street-level emissions is of less concern, our results clearly support the combination of street trees and rooftop PV as a highly complementary and effective means of adaptive mitigation across different climates and neighborhood densities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Contaminant Migration Modeling to Support the In Situ Decommissioning of Hardened Nuclear Facilities - 20215

The decommissioning of hardened nuclear facilities provides a unique challenge in balancing current worker dose with exposure to future receptors and media. In situ decommissioning (ISD) is a cost-effective and safe option for the closure of such facilities but requires a detailed understanding of the threat that radioactive and hazardous constituents remaining in the facilities pose to groundwater and surrounding surface water. The Savannah River Site (SRS) extensively employs contaminant migration models within the decommissioning process to develop site-specific removal, grouting, and monitoring strategies in support of safe and effective final end states of nuclear facilities. This work discusses the use of contaminant migration modeling in the ISD process at SRS, including specific examples from the closure of P-Reactor and R-Reactor, Building 235-F, F-Canyon and F/H Laboratory Complex. Migration models developed during the closure of P-Reactor and R-Reactor were divided into four source areas: the reactor vessel, the process area, the disassembly basin, and the purification wing. Each source area was assigned a specific inventory and migration pathway and was then subject to varying hypothetical removal, capping, and grouting schemes. Modeling indicated that groundwater Maximum Concentration Limits (MCLs) might be exceeded if no action was taken for eleven and ten constituents of concern (COCs) at P-Reactor and R-Reactor, respectively. These exceedances could occur in as few as 200 to 500 years. Alternatively, the migration modeling demonstrated that the selected ISD actions reduced contaminant mobility which allowed for significant radioactive decay and resulted in fewer predicted exceedances of groundwater MCLs (five COCs for P-Reactor; eight COCs for R-Reactor). In response to the modeling results for P-Reactor and R-Reactor, effectiveness monitoring programs were developed to target contaminants, specific to each reactor, that may migrate to groundwater. Contaminant migration modeling also revealed that roof collapse was a large factor in the release of COCs to the environment, giving rise to roof improvements, and an inspection and vegetation control program to ensure roof stability over time. Contaminant migration modeling is also aiding in the closure planning for hardened facilities in F Area. Building 235-F housed the Actinide Billet Line, which produced Np-237 billets for irradiation in SRS reactors, and the Plutonium Fuel Form (PuFF) facility that produced Pu-238 heat sources for the space program. As a result of these missions, areas within Building 235-F contain considerable residual amounts of both Pu-238 and Np-237. Contaminant migration modeling of Building 235-F was originally performed in 2012 to identify the feasibility of ISD and the amount of radioactive material removal required to prevent the exceedance of groundwater MCLs. The original model indicated that a 60% reduction in the PuFF facility Pu-238 inventory could keep groundwater concentrations below standards, while Np-237 did not pose a threat to groundwater. However, updates to the model with an emphasis on source impact pathways revealed that, due to the orientation of the source areas relative to groundwater flow, no amount of reasonable removal of Pu-238 would keep groundwater concentrations below MCLs and that Np-237 could be a large contributor to localized MCL exceedances. With this insight, the refined 2019 model is being used to assist in the development of grouting plans specific to each facility source area, where bentonite may be utilized to slow the migration of Pu-238 and its daughter products from the PuFF facility and a reducing grout may decrease Np-237 transport by ensuring the nuclide remains in the less mobile +IV oxidation state. The beginning phases of contaminant migration modeling are underway for F-Canyon and associated facilities using lessons learned from the Reactors and Building 235-F. A contaminant migration pathway, similar to the pathway used for the reactor vessels, is being developed for the hot and warm canyons. The F-Canyon inventories are being spatially refined to identify specific and localized source zones, comparable to Building 235-F, that may impact groundwater. Contaminant migration modeling provides vital input within the ISD process, from facility investigation to post closure effectiveness monitoring, making it a valuable tool in the development of safe and effective end states for hardened nuclear facilities at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Local Thermal Conductivity Patterning in Rotating Lattice Crystals of Anisotropic Sb 2 S 3

The ability to control material heat transport properties over space and time can drive advanced functionalities in thermal management for electronics and system-on-chip, and enable thermal circuits. Despite the technological relevance, there are limited demonstrations of local thermal property control. Rotating lattice single (RLS) crystals—formed via laser-induced crystallization of an amorphous substrate—offer a novel avenue for local crystal engineering, unlocking opportunities for microscale property patterning. Here, thermal conductivity (𝜅) imaging is applied to RLS crystals of Sb2S3 to resolve microscale 𝜅 variations across patterned regions. Amorphous areas exhibit 𝜅 as low as 0.6 Wm −1 K −1 , while crystalline regions display periodic 𝜅 variations from 0.7 to over 2.5 Wm −1 K −1 . These variations correspond to changes in crystal orientation, revealing marked 𝜅 anisotropy. The crystal out-of-plane direction (c axis)—featuring van der Waals bonds—shows amorphous-like transport, whereas in-plane directions (a, b axes) exhibit 3.5x and 1.7x larger 𝜅, respectively. First-principles calculations, in excellent agreement with experiments, suggest that the in-plane anisotropy originates from expressed Sb lone pairs, which impart a corrugation along the b axis affecting bond stiffness and 𝜅. These findings demonstrate microscale control of thermal properties via laser-processed metastructures, with significant implications for next-generation thermal management.

14 SOLAR ENERGY↗

Printable, emissivity-adaptive and albedo-optimized covering for year-round energy saving

Radiative cooling uses high-emissivity materials to passively cool the surface of outdoor objects, such as building roofs on hot days. The issue of overcooling with this technology on cold days can be addressed by structures with thermal emissivity that is adaptive to temperature. Despite recent advances in temperature-adaptive structures, great challenges remain in their fabrication feasibility and unoptimized solar heating that may override the radiative cooling benefit. Here, in this work, we develop a printable, emissivity-adaptive and albedo-optimized covering (PEAC) based on recyclable materials with roll-to-roll fabrication. A PEAC automatically switches its sky-window emissivity from 0.25 to 0.85 when the surface temperature exceeds a pre-set transition temperature, delivering an albedo optimized for maximal year-round energy saving or thermal comfort in a given climate.

36 MATERIALS SCIENCE↗

Nonproliferation Legacy Technology and Artifact Collection: NASA Space Shuttle Tiles

The NASA Space Shuttle Tiles were used by Sandia in the process of developing the Laser Dynamic Range Imager (LDRI) in support of NASA's Return to Flight following the 2003 Space Shuttle Columbia disaster. The heat shield tiles, provided to Sandia by NASA, are identical to those that were located on the underbelly of the Space Shuttle Columbia's orbiter. Sandia used the tiles to test the efficacy of the LDRI's imaging capabilities. The LDRI was utilized during every space shuttle mission between 2005 and 2011. The tiles are currently located in Building 891 and need to be moved to free up space for operational use. Given their technical significance, Sandia would like to archive them as historically significant items in long-term storage until such time as they can be appropriately displayed or employed as a demonstration artifact. This document provides basic information about the provenance of this artifact.

42 ENGINEERING↗

Dynamic Modeling, Trajectory Optimization, and Linear Control of Cable-Driven Parallel Robots for Automated Panelized Building Retrofits

The construction industry faces a growing need for automation to reduce costs, improve accuracy and productivity, and address labor shortages. One area that stands to benefit significantly from automation is panelized prefabricated building envelope retrofits, which can improve a building’s energy efficiency in heating and cooling interior spaces. In this paper, we propose using cable-driven parallel robots (CDPRs), which can effectively lift and handle large objects, to install these panels. However, implementing CDPRs presents significant challenges because of their nonlinear dynamics, complex trajectory planning, and precise control requirements. To tackle these challenges, this work focuses on a new application of established control and trajectory optimization theories in a CDPR simulation of a building envelope retrofit under real-world conditions. We first model the dynamics of CDPRs, highlighting the critical role of damping in system behavior. Building on this dynamic model, we formulate a trajectory optimization problem to generate feasible and efficient motion plans for the robot under operational and environmental constraints. Given the high precision required in the construction industry, accurately tracking the optimized trajectory is essential. However, challenges such as partial observability and external vibrations complicate this task. To address these issues, a Linear Quadratic Gaussian control framework is applied, enabling the robot to track the optimized trajectories with precision. Simulation results show that the proposed controller enables precise end effector positioning with errors under 4 mm, even in the presence of external wind disturbances. Through comprehensive simulations, our approach allows for an in-depth exploration of the system’s nonlinear dynamics, trajectory optimization, and control strategies under controlled yet highly realistic conditions. The results demonstrate the feasibility of CDPRs for automating panel installation and provide insights into their practical deployment.

CDPR↗

Formation and Redshift Evolution of Dark Matter Spikes

Dark matter density spikes forming around adiabatically growing black holes can dramatically enhance indirect and direct detection signals. Canonical predictions, however, assume a zero-mass seed in a purely dark matter environment and do not track the long-term dynamical impact of surrounding stars. We present a semi-analytic framework that first generalizes adiabatic spike formation to include finite seed masses, stellar cusps, and non-circular orbits, and then studies the subsequent cosmic evolution by solving coupled Fokker-Planck equations for the dark matter and stellar phase-space distributions, with a heating rate modulated by the cosmic star formation rate. Starting conservatively from canonical Gondolo-Silk spikes and marginalizing over astrophysical uncertainties, we find that stellar gravitational heating drives the inner slope towards $γ_χ\simeq 1.5$ within a few Gyrs (e.g by $z \lesssim 2$ for spikes formed at $z\simeq 10$), yielding overdensities two to four orders of magnitude below canonical expectations but still well above an NFW-like cusp. We provide redshift-dependent benchmarks for the column density and $J$-factor relevant to scattering, decay and annihilation signatures. Any robust interpretation of indirect dark matter signals from galactic nuclei must account for this evolution.

Herrera, Gonzalo [MIT, LNS; MIT, MKI; Harvard U.]↗