Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stress testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Composite PEMs from Electrospun Crosslinkable Poly(Phenylene Sulfonic Acid)s (Final Technical Report)

The main objective of this project is to fabricate and demonstrate superior fuel cell performance of an electrospun composite all-hydrocarbon, non-PFSA membrane. The project builds on two earlier, DOE-funded studies demonstrating high proton conductivity, even at very low humidity of crosslinkable poly(phenylenesulfonic acid), cPPSA, solution cast films, and high durability of electrospun perfluorosulfonic acid (PFSA) composite membranes. Most project milestones were fully met but the best membrane conductivity and fuel cell performance were obtained with membranes that did not contain electrospun sulfonated polyphenylene, as initially planned. Instead, an excellent performance was achieved with membranes fabricated by pore-filling, either with electrospun poly(phenyl sulfone) scaffolds or with commercial, expanded polytetrafluoroethylene scaffolds. Fuel cell testing demonstrated performance better than that of Nafion 211 or Nafion XL, particularly at lower cell humidification levels with significantly lower hydrogen crossover. No accelerated stress testing was performed, due to the initial numerous difficulties with controlling the copolymerization reaction, which took excessive amount of time to overcome. Potential scale-up of the proposed composite membrane technology can aid in boosting the fuel cell power output and simplification of the cell hydration system.

08 HYDROGEN↗

Effect of physical aging on stress relaxation of poly/methyl methacrylate/

A study was made on the stress relaxation behavior at 25 C of poly(methyl methacrylate) in uniaxial tension as a function of physical aging at both room temperature and 60 C. Test specimens were compression molded at 165 C, then quenched to room temperature and allowed to age for up to 30 days prior to testing. Stress relaxation curves measured after different aging times could be superposed to a single master curve for each aging temperature. Superposition was achieved by applying vertical and horizontal shifts. Hence, the shape of the response curves was not changed by aging. This is in accordance with observations made by Struik for tensile creep curves. Volume changes as a function of physical aging were also determined. Simple exponential relationships were observed between volume and both horizontal and vertical shifts. The horizontal shift implies a shift in the effective time scale caused by a change in free volume. The vertical shifts could be correlated with changes in Young's modulus caused by a change in density. For the range of aging studied, the response time scale varied over nearly two decades of log-time. For the same conditions modulus varied by 30 percent.

Cizmecioglu, M.↗

Hubble Space Telescope Battery Capacity Update

Orbital battery performance for the Hubble Space Telescope is discussed and battery life is predicted which supports decision to replace orbital batteries by 2009-2010 timeframe. Ground characterization testing of cells from the replacement battery build is discussed, with comparison of data from battery capacity characterization with cell studies of Cycle Life and 60% Stress Test at the Naval Weapons Surface Center (NWSC)-Crane, and cell Cycle Life testing at the Marshal Space Flight Center (MSFC). The contents of this presentation includes an update to the performance of the on-orbit batteries, as well as a discussion of the HST Service Mission 4 (SM4) batteries manufactured in 1996 and activated in 2000, and a second set of SM4 backup replacement batteries which began manufacture Jan 11, 2007, with delivery scheduled for July 2008.

Hollandsworth, Roger↗

Erosion Coatings Developed to Increase the Life and Durability of Composites

Both the NASA Glenn Research Center and the Allison Advanced Development Company (AADC) have worked to develop and demonstrate erosion-resistant coatings that would increase the life and durability of composite materials used in commercial aircraft engines. These composite materials reduce component weight by 20 to 30 percent and result in less fuel burn and emissions and more fuel savings. Previously, however, their use was limited because of poor erosion resistance, which causes concerns about safety and leads to high maintenance costs. The coatings were tested by the University of Cincinnati, and the composites were manufactured by Texas Composites and coated by Engelhard and NASA Glenn. Rolls-Royce Corporation uses composite materials, which are stronger and less dense than steel or titanium, to make bypass vanes for their AE3007 engines. These engines are widely used in regional jet aircraft (Embraer) and unmanned air vehicles such as the Northrop Grumman Global Hawk. Coatings developed by NASA/Rolls-Royce can reduce erosion from abrasive materials and from impurities in the air that pass over these vanes, allowing Rolls-Royce to take advantage of the benefits of composite materials over titanium without the added costs of increased maintenance and/or engine failure. The Higher Operating Temperature Propulsion Components (HOTPC) Project developed cost-effective, durable coatings as part of NASA's goal to increase aviation system capacity growth. These erosion coatings will reduce the number of special inspections or instances of discontinued service due to erosion, allowing aircraft capacity to be maintained without inconveniencing the traveling public. A specific example of extending component life showed that these coatings increased the life of graphite fiber and polymer composite bypass vanes up to 8 times over that of the uncoated vanes. This increased durability allows components to operate to full design life without the fear of wear or failure. Recently, Rolls-Royce completed over 2000 hr of engine testing with the coated fan exit bypass vanes. There was no loss of coating after nearly 5000 typical engine cycles. Midway through the engine tests, the coated vanes were removed from the engine during a scheduled maintenance and inspection period. The vanes were shipped back to Glenn, where they underwent further stress testing in the Structural Dynamics Lab, mimicking more extreme conditions than those typical of the AE3007 engine cycle. These vanes were then replaced in the AE3007 and subjected to another 1000 hr of engine tests. Once again, there was no loss of coating and only a minimal appearance of cracking.

Sutter, James K.↗

Field‐Relevant Degradation Mechanisms in Metal Halide Perovskite Modules

Field testing, failure analysis, and understanding of degradation mechanisms are essential to advancing metal halide perovskite (MHP) photovoltaic (PV) technology toward commercialization. Here, we present performance data from up to 1 year of outdoor testing of MHP modules in Golden, Colorado. The module encapsulation architecture and encapsulant materials have a significant impact on module reliability, with modules containing a polyolefin elastomer (POE) in addition to a desiccated polyisobutylene (PIB) edge seal outlasting modules with only a PIB edge seal or PIB blanket. Nondestructive and destructive characterization of the field-tested modules points to module scribes and interfaces as areas of potential mechanical weakness and chemical migration, resulting in shunt pathways and increased series resistance. Finally, indoor accelerated stress testing with light and elevated temperatures is performed, demonstrating failure with similar scribe degradation signatures as compared to the field-tested modules. In conclusion, under both outdoor testing and light and elevated temperature conditions, electrochemical corrosion between the copper electrode and the mobile iodine ions appeared dominant, with a significant progression at the scribes that is speculated to result from an interplay between the initial laser damage and joule heating from enhanced ion diffusion under bias.

14 SOLAR ENERGY↗

Influence of gaseous hydrogen on the mechanical properties of high temperature alloys

Tensile tests of six nickel-base and one cobalt-base alloy were conducted in 34.5 MN/sq m helium and hydrogen environments at temperatures from 297 K to 1,088 K. Mechanical properties tests of the nickel-base alloy MAR M-246 (Hf modified), in two cast conditions, were conducted in gaseous environments at temperatures from 297 K to 1,144 K and pressures from one atmosphere to 34.5 MN/sq m. The objective of this program was to obtain the mechanical properties of the various alloys proposed for use in space propulsion systems in a pure hydrogen environment at different temperatures and to compare with the mechanical properties in helium at the same conditions. All testing was conducted on solid specimens exposed to external gaseous pressure. Smooth and notched tensile properties were determined using ASTM tensile testing techniques, and creep-rupture life was determined using ASTM creep-rupture techniques. Low-cycle fatigue life was established by constant total strain and constant stress testing using smooth specimens and a closed-loop test machine.

Source record↗

Development of an Accelerated Test Design for Predicting the Service Life of the Solar Array at Mead, Nebraska

Potential long-term degradation modes for the two types of modules in the Mead array were determined and judgments were made as to those environmental stresses and combinations of stresses which accelerate the degradation of the power output. Hierarchical trees representing the severity of effects of stresses (test conditions) on eleven individual degradation modes were constructed and were pruned of tests judged to be nonessential. Composites of those trees were developed so that there is now one pruned tree covering eight degradation modes, another covering two degradation modes, and a third covering one degradation mode. These three composite trees form the basis for selection of test conditions in the final test plan which is now being prepared.

Gaines, G. B.↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

Assessing photovoltaic module degradation and lifetime from long term environmental tests

The photovoltaic module failure mechanisms related to temperature, humidity, and electrical bias are analyzed using the data collected over a period of 20 years from various sites in the U.S. The approach is based on measuring the rate dependence of the mechanisms on site stress levels, and then using the rate data to analytically estimate the field life by means of computer models of the site environment. A correlation is established between the accelerated constant-stress testing and the time-varying field exposures. Test results are presented for two failure mechanisms for a module design featuring polyvinyl butyral encapsulant for the temperature range of 85 to 100 C and 85-percent relative humidity.

Otth, D. H.↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting from Hot-Humid, High Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable, legacy aluminum back surface field (Al-BSF) cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60deg C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission (IEC) Technical Specification 62804-1; 70 deg C/70% RH for 200 h; and 85 deg C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage (I-V) curve tracing. Final characterizations included: Suns-Voc; spatial mapping of external quantum efficiency (EQE); high-resolution photoluminescence (PL), EL, and dark lock-in thermography (DLIT) imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy (XPS), and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline-corrosion and -delamination as well as other concurrent degradation modes. SEM/EDS and SAM identified conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

CF6 jet engine performance improvement: New fan

As part of the NASA sponsored engine component improvement program, and fan package was developed to reduce fuel consumption in current CF6 turbofan aircraft engine. The new fan package consist of an improved fan blade, reduced fan tip clearance due to a fan case stiffener, and a smooth fan casing tip shroud. CF6 engine performance and acoustic tests demonstrated the predicted 1.8% improvement in cruise sfc without an increase in engine noise. Power management thrust/fan speed characteristics were defined. Mechanical and structural integrity was demonstrated in model fan rotor photoelastic stress tests, full-size fan blade bench fatigue tests, and CF6 engine bird ingestion, crosswind, and cyclic endurance tests. The fan was certified in the CF6-500c2/E2 engines and is in commerical service on the Boeing 747-200, Douglas DC-10-30, and Atrbus industrie A300B aircraft.

Fasching, W. A.↗

Multirotor Test Bed Load and Stress Analysis

The Multirotor Test Bed (MTB) is a new capability for testing a wide array of advanced vertical take-off and landing (VTOL) rotor configurations, with a primary focus on testing in the U.S. Army 7- by 10-Foot Subsonic Wind Tunnel at NASA Ames Research Center. The MTB was designed to allow adjustment of the vertical, lateral, and longitudinal placement of up to six rotors, as well as allow tilt adjustment of each rotor and pitch adjustment of the whole assembly. The six-axis load cells under each rotor give the MTB the capability of measuring the rotor performance in a wide array of configurations. The overall goal of the MTB project is to help gain a better understanding of the performance, control, interactional aerodynamics, and acoustics of multirotor and tilting-rotor systems. The MTB project was initiated to build upon the knowledge and capabilities developed during the multirotor unmanned aerial systems (MUAS) tests in 2015 and 2017. By measuring individual rotor loads and allowing for adjustments to individual rotor position and attitude, the MTB provides a wealth of data on the aeroperformance of arbitrary multirotor configurations. The flexibility in positioning up to six rotors allows the multirotor design space to be parametrically explored and potentially optimized. The MTB is also at a larger scale than the small unmanned aerial systems (UAS) tested before, which allows for testing at rotor tip Reynolds numbers more relevant to full-scale piloted electric vertical take-off and landing (eVTOL) aircraft. This document contains the complete documentation of the design, loads, and stress analysis of the MTB.

Multirotor Test Bed↗

Reliability and engineering sciences area. Materials research: Single junction thin film

A test bench was designed and fabricated for the purpose of improving control of hot-spot test accuracy. Electrochemical corrosion research focused on corrosion mechanisms to which both crystalline and a-Si modules may be subjected in central station applications. A variety of cells and several designs were subjected to accelerated stress tests. Humiditiy degradation rates were determined and key electrochemical failure mechanisms were identified. Software was developed for the prediction of power loss resulting from open circuits in an array field of a-Si modules. Failure analysis was continued on the four ARCO Solar Genesis modules. The interactions of water on the silicon module was examined. An autocatalytic photooxidation model was proposed. The reliability and durability of bonding materials and electrical insulation were also studied.

Source record↗

NASA Tech Briefs, June 2006

Topics covered include: Magnetic-Field-Response Measurement-Acquisition System; Platform for Testing Robotic Vehicles on Simulated Terrain; Interferometer for Low-Uncertainty Vector Metrology; Rayleigh Scattering for Measuring Flow in a Nozzle Testing Facility; "Virtual Feel" Capaciflectors; FETs Based on Doped Polyaniline/Polyethylene Oxide Fibers; Miniature Housings for Electronics With Standard Interfaces; Integrated Modeling Environment; Modified Recursive Hierarchical Segmentation of Data; Sizing Structures and Predicting Weight of a Spacecraft; Stress Testing of Data-Communication Networks; Framework for Flexible Security in Group Communications; Software for Collaborative Use of Large Interactive Displays; Microsphere Insulation Panels; Single-Wall Carbon Nanotube Anodes for Lithium Cells; Tantalum-Based Ceramics for Refractory Composites; Integral Flexure Mounts for Metal Mirrors for Cryogenic Use; Templates for Fabricating Nanowire/Nanoconduit- Based Devices; Measuring Vapors To Monitor the State of Cure of a Resin; Partial-Vacuum-Gasketed Electrochemical Corrosion Cell; Theodolite Ring Lights; Integrating Terrain Maps Into a Reactive Navigation Strategy; Reducing Centroid Error Through Model-Based Noise Reduction; Adaptive Modeling Language and Its Derivatives; Stable Satellite Orbits for Global Coverage of the Moon; and Low-Cost Propellant Launch From a Tethered Balloon

Source record↗

Tension-tension fatigue behavior of the Space Shuttle strain-isolation-pad material

The room temperature fatigue behavior of 0.41-cm (0.16-in) thick strain-isolation-pad (SIP) material was explored in a series of constant- and random-amplitude loading tests. The SIP material is used on the Space Shuttle to isolate the ceramic insulating tiles from the strains and deflections of the aluminum alloy airframe. In all tests, 12.7 by 12.7 cm (5.0 by 5.0 in) SIP specimens were subjected to tension-tension loading in the through-the-thickness direction at a frequency of 10 Hz. When subjected to cyclic loading, the SIP material exhibited a monotonic increase in thickness and a monotonic increase in tensile tangent moduli. The rate of thickness growth increased with increasing test stress level and decreased with increasing number cycles endured. Power law equations were found to provide a good representation of the thickness growth rate data. Tensile tangent moduli increased by as much as 80 percent during fatigue tests. Simple cumulative damage fatigue models predicted the mean thickness growth under random-amplitude loading with reasonable accuracy (factor of 2 on life).

Phillips, E. P.↗

Low strain, long life creep fatigue of AF2-1DA and INCO 718

Two aircraft turbine disk alloys, GATORIZED AF2-DA and INCO 718 were evaluated for their low strain long life creep-fatigue behavior. Static (tensile and creep rupture) and cyclic properties of both alloys were characterized. The cntrolled strain LCF tests were conducted at 760 C (1400 F) and 649 C (1200 F) for AF2-1DA and INCO 718, respectively. Hold times were varied for tensile, compressive and tensile/compressive strain dwell (relaxation) tests. Stress (creep) hold behavior of AF2-1DA was also evaluated. Generally, INCO 718 exhibited more pronounced reduction in cyclic life due to hold than AF2-1DA. The percent reduction in life for both alloys for strain dwell tests was greater at low strain ranges (longer life regime). Changing hold time from 0 to 0.5, 2.0 and 15.0 min. resulted in corresponding reductions in life. The continuous cycle and cyclic/dwell initiation failure mechanism was predominantly transgranular for AF2-1DA and intergranular for INCO 718.

Thakker, A. B.↗

Physiological response to exercise after space flight - Apollo 14 through Apollo 17

Submaximal exercise stress tests were conducted preflight and postflight on the Apollo 14-17 crewmen. A bicycle ergometer was utilized to evoke target heart rates up to 160 beats/min while respiratory gas exchange, blood pressure, and cardiac output were measured. Three preflight tests were conducted during the month prior to flight to establish baseline values for postflight comparisons. Tachycardia was evidenced at rest and during exercise immediately postflight. This transitory tachycardia compensated for reduced stroke volume. Systolic blood pressure was reduced during exercise stress, but no consistent changes were observed in diastolic blood pressure. With the exception of the Apollo 15 crewmen, all crewmen had returned to preflight response levels by the day following recovery. No changes were observed in mechanical or respiratory efficiency immediately postflight.

Rummel, J. A.↗

Ring element dynamic stresses

The stresses in the CTRAPRG and CTRIARG ring elements are not calculated for any of the dynamic solutions in the current COSMIC version of NASTRAN. A DMAP alter sequence for Solution 8 and post-processing program, NASTPOST, are presented to calculate these stresses. Test cases are used which describe the method. The stiffness and the consistent versus concentrated mass problems ascribed to this element are reviewed. The DMAP alter sequence introduces Solution 8 displacements to a Solution 1 module to calculate real and imaginary stress components during the execution of Solution 8. The post-processor, NASTPOST, calculates the magnitude/phase stress results. The DMAP sequence was written specifically for level 52 MSC/NASTRAN, but can certainly be used for any COSMIC version with slight modification.

Lambert, N.↗