Search NASA⌕ Search

SEARCH · Search NASA

Results for “Supine Position”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

SU-E-T-292: Dosimetric Advantage of Prone Breast Radiotherapy for Korean Left-Sided Breast Cancer Patients

Purpose: To evaluate the dosimetric benefit of prone breast radiotherapy for Korean left-sided early-stage breast cancer patients who have relatively small breast Methods: From April to June, 2014, 10 left-sided breast cancer patients received the whole breast irradiation in prone position after partial mastectomy with sentinel lymph node biopsy or axillary lymph node dissection. All patients were pTmi-2N0-1mi. Each patient underwent two computed tomoradiography (CT) simulations in supine and prone positions. The whole breast, ipsilateral lung, heart, and left anterior descending coronary artery (LAD) were contoured on each simulation CT images, and then tangential-fields treatment plan in each position was designed for the whole breast irradiation with the total dose of 50 Gy in 2 Gy fractions. Dose-volume histograms of two setups were compared for target coverage and radiation dose to normal organs with Wilcoxon signed rank tests. Results: The median age of patients was 47 years (range, 37 to 53). The median chest size was 82.5 cm (range, 75 to 90) and bra cup size was A in 4, B in 4, and C in 2 patients. The radiation dose to the whole breast was similar when comparing mean dose (Dmean) and dose covering 95% of the breast volume, but maximum dose (Dmax) of breast was higher in supine (median 52.3 vs. 52.7 Gy, p=0.013). Prone position reduced significantly the radiation dose in ipsilateral lung, heart, and LAD by median 5.7, 1.1, and 6.9 Gy of Dmean (p=0.005, 0.007, and 0.005) and 28.2, 18.8, and 35.0 Gy of Dmax (p=0.005, 0.005, and 0.007), respectively. Conclusion: Prone breast radiotherapy could be beneficial for Korean breast cancer patients since it substantially spared normal organs while achieving adequate coverage of the breast tissue. Further prospective study is required to validate the potential benefit of prone breast radiotherapy.

60 APPLIED LIFE SCIENCES↗

Multiple-breath washin of helium and sulfur hexafluoride in sustained microgravity

We performed multiple-breath washouts of N2 and simultaneous washins of He and SF6 with fixed tidal volume (approximately 1,250 ml) and preinspiratory lung volume (approximately the subject's functional residual capacity in the standing position) in four normal subjects (mean age 40 yr) standing and supine in normal gravity (1 G) and during exposure to sustained microgravity (microG). The primary objective was to examine the influence of diffusive processes on the residual, nongravitational ventilatory inhomogeneity in the lung in microG. We calculated several indexes of convective ventilatory inhomogeneity from each gas species. A normal degree of ventilatory inhomogeneity was seen in the standing position at 1 G that was largely unaltered in the supine position. When we compared the standing position in 1 G with microG, there were reductions in phase III slope in all gases, consistent with a reduction in convection-dependent inhomogeneity in the lung in microG, although considerable convective inhomogeneity persisted in microG. The reductions in the indexes of convection-dependent inhomogeneity were greater for He than for SF6, suggesting that the distances between remaining nonuniformly ventilated compartments in microG were short enough for diffusion of He to be an effective mechanism to reduce gas concentration differences between them.

NASA Discipline Cardiopulmonary↗

SU-E-T-255: Optimized Supine Craniospinal Irradiation with Image-Guided and Field Matched Beams

Purpose: Conventional craniospinal irradiation (CSI) challenges include dose inhomogeneity at field junctions and position uncertainty due to the field divergence, particular for the two spinal fields. Here we outline a new supine CSI technique to address these difficulties. Methods: Patient was simulated in supine position. The cranial fields had isocenter at C2/C3 vertebral and were matched with 1st spinal field. Their inferior border was chosen to avoid the shoulder, as well as chin from the 1st spine field. Their collimator angles were dependent on asymmetry jaw setting of the 1st spinal field. With couch rotation, the spinal field gantry angles were adjusted to ensure, the inferior border of 1st and superior border of 2nd spinal fields were perpendicular to the table top. The radio-opaque wire position for the spinal junction was located initially by the light field from an anterior setup beam, and was finalized by the portal imaging of the 1st spinal field. With reference to the spinal junction wire, the fields were matched by positioning the isocenter of the 2nd spinal field. A formula was derived to optimize supine CSI treatment planning, by utilizing the relationship among the Yjaw setting, the spinal field gantry angles, cranial field collimator angles, and the spinal field isocenters location. The plan was delivered with portal imaging alignment for the both cranial and spinal junctions. Results: Utilizing this technique with matching beams, and conventional technique such as feathering and forwarding planning, a homogenous dose distribution was achieved throughout the entire CSI treatment volume including the spinal junction. Placing the spinal junction wire visualized in both spinal portals, allows for precise determination and verification of the appropriate match line of the spine fields. Conclusion: This technique of optimization supine CSI achieved a homogenous dose distributions and patient localization accuracy with image-guided and matched beams.

60 APPLIED LIFE SCIENCES↗

Intra- and Interfractional Variations for Prone Breast Irradiation: An Indication for Image-Guided Radiotherapy

Purpose: Intra- and interfractional errors for breast cancer patients undergoing breast irradiation in the prone position were analyzed. Methods and Materials: To assess intrafractional error resulting from respiratory motion, four-dimensional computed tomography scans were acquired for 3 prone and 3 supine patients, and the respiratory motion was compared for the two positions. To assess the interfractional error caused by daily set-up variations, daily electronic portal images of one of the treatment beams were taken for 15 prone-positioned patients. Portal images were then overlaid with images from the planning system that included the breast contour and the isocenter, treatment beam portal, and isocenter. The shift between the planned and actual isocenter was recorded for each portal image, and descriptive statistics were collected for each patient. The margins were calculated using the 2{sigma}+0.7{sigma} recipe, as well as 95% confidence interval based on the pooled standard deviation of the datasets. Results: Respiratory motion of the chest wall is drastically reduced from 2.3 {+-} 0.9 mm in supine position to -0.1 {+-} 0.4 mm in prone position. The daily set-up errors vary in magnitude from 0.0 cm to 1.65 cm and are patient dependent. The margins were defined by considering only the standard deviation to be 1.1 cm, and 2.0 cm when the systematic errors were considered using the 2{sigma}+0.7{sigma} recipe. Conclusions: Prone positioning of patients for breast irradiation significantly reduces the uncertainty introduced by intrafractional respiratory motion. The presence of large systematic error in the interfractional variations necessitates a large clinical target volume-to-planning target volume margin and indicates the importance of image guidance for partial breast irradiation in the prone position, particularly using imaging modality capable of identifying the lumpectomy cavity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generic method for automatic bladder segmentation on cone beam CT using a patient-specific bladder shape model

Purpose: The aim of this study is to develop and validate a generic method for automatic bladder segmentation on cone beam computed tomography (CBCT), independent of gender and treatment position (prone or supine), using only pretreatment imaging data. Methods: Data of 20 patients, treated for tumors in the pelvic region with the entire bladder visible on CT and CBCT, were divided into four equally sized groups based on gender and treatment position. The full and empty bladder contour, that can be acquired with pretreatment CT imaging, were used to generate a patient-specific bladder shape model. This model was used to guide the segmentation process on CBCT. To obtain the bladder segmentation, the reference bladder contour was deformed iteratively by maximizing the cross-correlation between directional grey value gradients over the reference and CBCT bladder edge. To overcome incorrect segmentations caused by CBCT image artifacts, automatic adaptations were implemented. Moreover, locally incorrect segmentations could be adapted manually. After each adapted segmentation, the bladder shape model was expanded and new shape patterns were calculated for following segmentations. All available CBCTs were used to validate the segmentation algorithm. The bladder segmentations were validated by comparison with the manual delineations and the segmentation performance was quantified using the Dice similarity coefficient (DSC), surface distance error (SDE) and SD of contour-to-contour distances. Also, bladder volumes obtained by manual delineations and segmentations were compared using a Bland-Altman error analysis. Results: The mean DSC, mean SDE, and mean SD of contour-to-contour distances between segmentations and manual delineations were 0.87, 0.27 cm and 0.22 cm (female, prone), 0.85, 0.28 cm and 0.22 cm (female, supine), 0.89, 0.21 cm and 0.17 cm (male, supine) and 0.88, 0.23 cm and 0.17 cm (male, prone), respectively. Manual local adaptations improved the segmentation results significantly (p < 0.01) based on DSC (6.72%) and SD of contour-to-contour distances (0.08 cm) and decreased the 95% confidence intervals of the bladder volume differences. Moreover, expanding the shape model improved the segmentation results significantly (p < 0.01) based on DSC and SD of contour-to-contour distances. Conclusions: This patient-specific shape model based automatic bladder segmentation method on CBCT is accurate and generic. Our segmentation method only needs two pretreatment imaging data sets as prior knowledge, is independent of patient gender and patient treatment position and has the possibility to manually adapt the segmentation locally.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-EF-BRB-06: Implementation of a Modulated-Arc Total Body Irradiation (TBI) Technique Using the RayStation Treatment Planning System

Purpose: To develop a clinical workflow for delivering a modulated-arc total body irradiation (TBI) with RayStation scripting. This technique uses arc fields with the patient lying at floor level on a padded table and is validated through measurements taken on a custom-made TBI phantom. Methods: Treatment planning was performed for a retrospective cohort of eight patients with a diverse range of heights and body types. Each was replanned using an open-field dual arc method, with the patient in supine and prone positions on the floor of the vault. All plans were optimized using Raystation Planning 4.7.2.5 (RaySearch Laboratories, Stockholm, Sweden), with 200 cGy prescribed to the 95% of the body contour − 5mm. This results in an open-field beam that sweeps craniocaudally across the length of the patient. The technique is validated with measurements at 10 cm intervals in a custom-milled, 5 cm thick acrylic phantom. A centrally located CC13 ion chamber and a Mobile MOSFET (Best Medical Canada, Ottawa, ON) detector array were used to measure dose. Supine and prone arcs for each patient were consecutively delivered, and the aggregate dose at each point was compared to the planned dose calculated in the phantom. Results: The ion chamber measurements differed from the planned dose by an average of .5%, with a standard deviation of 2.1%. All measured data for the MOSFETS were within 10% of the corresponding planned dose except for two outlying points. The standard deviation of dose differences across the entire cohort was 4.0%. Most significant discrepancies occurred either in inhomogeneous regions with large gradients, or at inferior points where beam angle was steepest. Conclusion: We have confirmed that the planned dose is well matched to our measurements within 10% for this method of planning and delivery. We are currently incorporating this technique into our clinical workflow. This work is supported by RaySearch.

60 APPLIED LIFE SCIENCES↗

Transfer function analysis of the autonomic response to respiratory activity during random interval breathing

We report a new method for the noninvasive characterization of the frequency response of the autonomic nervous system (ANS) in mediating fluctuations in heart rate (HR). The approach entails computation of the transfer function magnitude and phase between instantaneous lung volume and HR. Broad band fluctuations in lung volume were initiated when subjects breathed on cue to a sequence of beeps spaced randomly in time. We studied 10 subjects in both supine and standing positions. The transfer function, averaged among all the subjects, showed systematic differences between the two postures, reflecting the differing frequency responses of the sympathetic and parasympathetic divisions of the ANS.

Non-NASA Center↗

Dosimetric aspects of inverse-planned modulated-arc total-body irradiation

Purpose: To develop optimal beam parameters and to verify the dosimetric aspects of the recently developed modulated-arc total-body irradiation (MATBI) technique, which delivers an inverse-planned dose to the entire body using gantry rotation. Methods: The patient is positioned prone and supine underneath the gantry at about 2 m source-to-surface distance (SSD). Then, up to 28 beams irradiate the patient from different gantry angles. Based on full-body computed-tomography (CT) images of the patient, the weight of each beam is optimized, using inverse planning, to create a uniform body dose. This study investigates how to best simulate patients and the ideal beam setup parameters, such as field size, number of beams, and beam geometry, for treatment time and dose homogeneity. In addition, three anthropomorphic water phantoms were constructed and utilized to verify the accuracy of dose delivery, with both diode array and ion chamber measurements. Furthermore, to improve the accuracy of the new technique, a beam model is created specifically for the extended-SSD positioning for MATBI. Results: Low dose CT scans can be utilized for dose calculations without affecting the accuracy. The largest field size of 40 Multiplication-Sign 40 cm{sup 2} was found to deliver the most uniform dose in the least amount of time. Moreover, a higher number of beams improves dose homogeneity. The average dose discrepancy between ion chamber measurements and extended-SSD beam model calculations was 1.2%, with the largest discrepancy being 3.2%. This average dose discrepancy was 1.4% with the standard beam model for delivery at isocenter. Conclusions: The optimum beam setup parameters, regarding dose uniformity and treatment duration, are laid out for modulated-arc TBI. In addition, the presented dose measurements show that these treatments can be delivered accurately. These measurements also indicated that a new beam model did not significantly improve the accuracy of dose calculations. The optimum beam setup parameters along with the measurements performed to ensure accurate dose delivery serve as a useful guide for the clinical implementation of MATBI.

60 APPLIED LIFE SCIENCES↗

Cardiovascular regulation in microgravity

The human cardiovascular adaptation to microgravity was investigated in the framework of the German Spacelab D2 mission. Preflight and postflight studies were performed to examine the relationship between disuse atrophy and the function of cardiac and skeletal muscles. Special attention was given to fluid load responses and postflight orthostatic hypotension. The preflight measurements were obtained, in supine and sitting positions. These measurements, carried out in the four D2 crew members, were performed six and nine months before flight and on mission day number five. The results obtained on the male crew showed that the stroke volume data from microgravity are virtually identical to preflight measurements in the sitting position.

C. G. Blomqvist↗

Visual- and Vestibular-Autonomic Influence on Short-Term Cardiovascular Regulatory Mechanisms

This synergy project was a one-year effort conducted cooperatively by members of the NSBRI Cardiovascular Alterations and Neurovestibular Adaptation Teams in collaboration with NASA Johnson Space Center (JSC) colleagues. The objective of this study was to evaluate visual autonomic interactions on short-term cardiovascular regulatory mechanisms. Based on established visual-vestibular and vestibular-autonomic shared neural pathways, we hypothesized that visually induced changes in orientation will trigger autonomic cardiovascular reflexes. A second objective was to compare baroreflex changes during postural changes as measured with the new Cardiovascular System Identification (CSI) technique with those measured using a neck barocuff. While the neck barocuff stimulates only the carotid baroreceptors, CSI provides a measure of overall baroreflex responsiveness. This study involved a repeated measures design with 16 healthy human subjects (8 M, 8 F) to examine cardiovascular regulatory responses during actual and virtual head-upright tilts. Baroreflex sensitivity was first evaluated with subjects in supine and upright positions during actual tilt-table testing using both neck barocuff and CSI methods. The responses to actual tilts during this first session were then compared to responses during visually induced tilt and/or rotation obtained during a second session.

Mullen, Thomas J.↗

Bed Rest and Orthostatic-Hypotensive Intolerance

Orthostatic tolerance may be defined as the ability of humans to maintain cerebral perfusion and consciousness upon movement from a supine or sitting position to the upright posture; for example, subjects can stand suddenly or be tilted to the head-up body position. Similar but not identical physiological responses can be induced by positive G(sub Z) (head to foot) acceleration or exposure to lower body negative pressure (LBNP). The objective is to suddenly shift blood to the lower body to determine how effectively cardiovascular and neural-hormonal compensatory responses react to maintain blood pressure. In the most precise method for measuring tolerance, individuals would be stressed until they faint (syncope). However, the potential consequences and discomforts of such a test usually prohibit such a procedure so that few investigators actually induce syncope. In a more common approach, subjects are exposed to a given level of stress, for example, head-up tilt for 15 min, and any increases in heart rate or decreases in blood pressure are interpreted as indicators of progress toward syncope. Presumably, the greater the perturbation of heart rate and blood pressure, the closer to "tolerance," i.e., point of unconsciousness. Another more appropriate approach is to induce a progressively increasing hypotensive stress until pre-determined physiological responses or pre-syncopal symptoms appear. The physiological criteria may include a sudden drop in systolic blood pressure (greater than 25 mm/min), a sudden drop in heart rate (greater than 15 beats/min), or a systolic blood pressure less than 70 mmHg. The most common pre-syncopal symptoms include lightheadedness, stomach awareness or distress, feelings of warmth, tingly skin, and light to profuse sweating. Usually a combination of physiological responses and symptoms occurs such that, on different days, the tolerance time to the same orthostatic protocol is reproducible for a given individual. The assumption is that by taking subjects to near fainting, one can determine their tolerance. This latter pre-syncopal approach is better for estimating orthostatic or hypotensive tolerance than the former measurement of heart rate and blood pressure responses to a given stress. There is considerable variability in individual responses to orthostasis. For example, some subjects are "heart-rate responders" and have a pronounced cardiovascular response similar to that when performing moderately hard aerobic exercise, whereas others may experience pre-syncopal symptoms with very little increase in heart rate. Some individuals have a slow, gradual fall in blood pressure to orthostasis, and others have little change in blood pressure until a sudden precipitous fall in pressure occurs just prior to fainting. With both tilt and LBNP tests there is a low correlation between heart-rate or blood-pressure responses to a sub-tolerance stress as a measure of pre-syncopal limited orthostatic-hypotensive tolerance.

Schneider, Suzanne M.↗

Kinematic principles of primate rotational vestibulo-ocular reflex. I. Spatial organization of fast phase velocity axes

The spatial organization of fast phase velocity vectors of the vestibulo-ocular reflex (VOR) was studied in rhesus monkeys during yaw rotations about an earth-horizontal axis that changed continuously the orientation of the head relative to gravity ("barbecue spit" rotation). In addition to a velocity component parallel to the rotation axis, fast phases also exhibited a velocity component that invariably was oriented along the momentary direction of gravity. As the head rotated through supine and prone positions, torsional components of fast phase velocity axes became prominent. Similarly, as the head rotated through left and right ear-down positions, fast phase velocity axes exhibited prominent vertical components. The larger the speed of head rotation the greater the magnitude of this fast phase component, which was collinear with gravity. The main sequence properties of VOR fast phases were independent of head position. However, peak amplitude as well as peak velocity of fast phases were both modulated as a function of head orientation, exhibiting a minimum in prone position. The results suggest that the fast phases of vestibulo-ocular reflexes not only redirect gaze and reposition the eye in the direction of head motion but also reorient the eye with respect to earth-vertical when the head moves relative to gravity. As further elaborated in the companion paper, the underlying mechanism could be described as a dynamic, gravity-dependent modulation of the coordinates of ocular rotations relative to the head.

Non-NASA Center↗

Intramuscular pressure varies with depth. The tibialis anterior muscle studied in 12 volunteers

Pressures in the tibialis anterior muscle were recorded at rest and during exercise with transducer-tipped catheters in 12 volunteers while they were supine or standing. The recordings were repeated with venous stasis created by an inflated tourniquet cuff on the thigh. Catheters were placed at 3 different sites in the muscle: catheter I adjacent to the deep surface of the fascia over the anterior compartment; catheter II between the fascia and the central tendon; and catheter III deep in the muscle close to the interosseous membrane. In both the supine and standing positions the intramuscular pressure at rest and the muscle relaxation pressure during exercise, obtained by catheter II, were greater than the corresponding pressures measured by the superficially located catheter I in the normal as well as in the volume loaded limb. The same conditions for pressure measurement consistently revealed lower pressures recorded by catheter III compared to II, but the difference was not significant. Our results indicate that intramuscular pressure increases centripetally, as the centrally lying tendon is approached. We conclude that pressure measurements for diagnosis of acute and chronic compartment syndromes and in ergonomic studies should be based on recordings from a standard location of the catheter within the muscle and a standard posture of the subject.

NASA Discipline Musculoskeletal↗

Pilot Field Test: Use of a Compression Garment During a Stand Test After Long-Duration Space Flight

Orthostatic intolerance (OI) is a concern for astronauts returning from long-duration space flight. One countermeasure that has been used to protect against OI after short-duration bed rest and space flight is the use of lower body and abdominal compression garments. However, since the end of the Space Shuttle era we have not been able to test crewmembers during the first 24 hours after landing on Earth. NASA's Pilot Field Test provided us the opportunity to test cardiovascular responses of crewmembers wearing the Russian Kentavr compression garment during a stand test at multiple time points throughout the first 24 hours after landing. HYPOTHESIS We hypothesized that the Kentavr compression garment would prevent an increase in heart rate (HR) >15 bpm during a 3.5-min stand test. METHODS: The Pilot Field Test was conducted up to 3 times during the first 24 hours after crewmembers returned to Earth: (1) either in a tent adjacent to the Soyuz landing site in Kazakhstan (approx.1 hr) or after transportation to the Karaganda airport (approx. 4 hr); (2) during a refueling stop in Scotland (approx.12 hr); and (3) upon return to NASA Johnson Space Center (JSC) (approx.24 hr). We measured HR and arterial pressure (finger photoplethysmography) for 2 min while the crewmember was prone and throughout 3.5 min of quiet standing. Eleven crewmembers consented to participate; however, 2 felt too ill to start the test and 1 stopped 30 sec into the stand portion of the test. Of the remaining 8 crewmembers, 2 did not wear the Russian Kentavr compression garment. Because of inclement weather at the landing site, 5 crewmembers were flown by helicopter to the Karaganda airport before initial testing and received intravenous saline before completing the stand test. One of these crewmembers wore only the portion of the Russian Kentavr compression garment that covered the lower leg and thus lacked thigh and abdominal compression. All crewmembers continued wearing the Russian Kentavr compression garment during the second testing session in Scotland, but none wore it during testing at JSC. RESULTS: The mean Delta HR from the supine to standing position in the 8 crewmembers measured pre-flight or 60 days after return from long-duration space flight was 9.8 bpm. During the first few hours after landing from long-duration space flight, the mean Delta HR of the 6 crewmembers who wore the Russian Kentavr compression garment in Kazakhstan or Karaganda was +14 bpm and the change in mean arterial pressure (Delta MAP) was +0.8 mmHg, while the 2 crewmembers who did not wear the Russian Kentavr compression garment had a Delta HR of +38 bpm and a Delta MAP of +1.1 mmHg. In Scotland, 4 crewmembers wore the Russian Kentavr compression garment and had a Delta HR of +7.4 bpm while the 3 crewmembers who did not wear it had a Delta HR of +25.0 bpm. Seven crewmembers were tested upon return to JSC approx. 24 hr after landing, but none wore the Russian Kentavr compression garment and their Delta HR was 16.0 bpm. CONCLUSIONS: These are the first stand-test data to be collected from long-duration crewmembers during the first 24 hr of re-adaptation to gravity on Earth. The Delta HR measured in crewmembers who completed the stand-test while wearing Kentavr within the first approx.4 hours after returning to Earth was only slightly elevated from pre-flight Delta HR, while the few subjects who did not wear the Russian Kentavr compression garment had a much larger increase in HR in order to maintain arterial pressure throughout 3.5-min of standing. These data demonstrate the effectiveness of a compression garment in preventing large increases in HR during a 3.5 min stand test after long-duration space flight. However, the fact that three crewmembers were too ill to complete the test or was not able to complete 3.5 min of standing despite wearing the Russian Kentavr compression garment indicates that wearing a compression garment does not resolve all problems crewmembers face during the period of re-adaptation immediately after return to Earth's gravity.

Laurie, S. S.↗

Cardiovascular responses to postural changes: differences with age for women and men

The cardiovascular responses to postural change, and how they are affected by aging, are inadequately described in women. Therefore, the authors examined the influence of age and sex on the responses of blood pressure, cardiac output, heart rate, and other variables to change in posture. Measurements were made after 10 minutes each in the supine, seated, and standing positions in 22 men and 25 women who ranged in age from 21 to 59 years. Several variables differed, both by sex and by age, when subjects were supine. On rising, subjects' diastolic and mean arterial pressures, heart rate, total peripheral resistance (TPR), and thoracic impedance increased; cardiac output, stroke volume, and mean stroke ejection rate decreased; and changes in all variables, except heart rate, were greater from supine to sitting than sitting to standing. The increase in heart rate was greater in the younger subjects, and increases in TPR and thoracic impedance were greater in the older subjects. Stroke volume decreased less, and TPR and thoracic impedance increased more, in the women than in the men. The increase in TPR was particularly pronounced in the older women. These studies show that the cardiovascular responses to standing differ, in some respects, between the sexes and with age. The authors suggest that the sex differences are, in part, related to greater decrease of thoracic blood volume with standing in women than in men, and that the age differences result, in part, from decreased responsiveness of the high-pressure baroreceptor system.

Posture/physiology↗

Pulmonary blood flow distribution in sheep: effects of anesthesia, mechanical ventilation, and change in posture

BACKGROUND: Recent studies providing high-resolution images of pulmonary perfusion have questioned the classical zone model of pulmonary perfusion. Hence the present work was undertaken to provide detailed maps of regional pulmonary perfusion to examine the influence of anesthesia, mechanical ventilation, and posture. METHODS: Pulmonary perfusion was analyzed with intravenous fluorescent microspheres (15 microm) in six sheep studied in four conditions: prone and awake, prone with pentobarbital-anesthesia and breathing spontaneously, prone with anesthesia and mechanical ventilation, and supine with anesthesia and mechanical ventilation. Lungs were air dried at total lung capacity and sectioned into approximately 1,100 pieces (about 2 cm3) per animal. The pieces were weighed and assigned spatial coordinates. Fluorescence was read on a spectrophotometer, and signals were corrected for piece weight and normalized to mean flow. Pulmonary blood flow heterogeneity was assessed using the coefficient of variation of flow data. RESULTS: Pentobarbital anesthesia and mechanical ventilation did not influence perfusion heterogeneity, but heterogeneity increased when the animals were in the supine posture (P < 0.01). Gravitational flow gradients were absent in the prone position but present in the supine (P < 0.001 compared with zero). Pulmonary perfusion was distributed with a hilar-to-peripheral gradient in animals breathing spontaneously (P < 0.05). CONCLUSIONS: The influence of pentobarbital anesthesia and mechanical ventilation on pulmonary perfusion heterogeneity is small compared with the effect of changes in posture. Analysis of flow gradients indicate that gravity plays a small role in determining pulmonary blood flow distribution.

NASA Discipline Cardiopulmonary↗

Mechanisms underlying very-low-frequency RR-interval oscillations in humans

BACKGROUND: Survival of post-myocardial infarction patients is related inversely to their levels of very-low-frequency (0.003 to 0.03 Hz) RR-interval variability. The physiological basis for such oscillations is unclear. In our study, we used blocking drugs to evaluate potential contributions of sympathetic and vagal mechanisms and the renin-angiotensin-aldosterone system to very-low-frequency RR-interval variability in 10 young healthy subjects. METHODS AND RESULTS: We recorded RR intervals and arterial pressures during three separate sessions, with the patient in supine and 40 degree upright tilt positions, during 20-minute frequency (0.25 Hz) and tidal volume-controlled breathing after intravenous injections: saline (control), atenolol (0.2 mg/kg, beta-adrenergic blockade), atropine sulfate (0.04 mg/kg, parasympathetic blockade), atenolol and atropine (complete autonomic blockade), and enalaprilat (0.02 mg/kg, ACE blockade). We integrated fast Fourier transform RR-interval spectral power at very low (0.003 to 0.03 Hz), low (0.05 to 0. 15 Hz), and respiratory (0.2 to 0.3 Hz) frequencies. Beta-adrenergic blockade had no significant effect on very-low- or low-frequency RR-interval power but increased respiratory frequency power 2-fold. ACE blockade had no significant effect on low or respiratory frequency RR-interval power but modestly (approximately 21%) increased very-low-frequency power in the supine (but not upright tilt) position (P<0.05). The most profound effects were exerted by parasympathetic blockade: Atropine, given alone or with atenolol, abolished nearly all RR-interval variability and decreased very-low-frequency variability by 92%. CONCLUSIONS: Although very-low-frequency heart period rhythms are influenced by the renin-angiotensin-aldosterone system, as low and respiratory frequency RR-interval rhythms, they depend primarily on the presence of parasympathetic outflow. Therefore the prognostic value of very-low-frequency heart period oscillations may derive from the fundamental importance of parasympathetic mechanisms in cardiovascular health.

Non-NASA Center↗