Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface acoustic waves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Statistically elucidated responses from low-signal contrast mechanisms in ultrafast electron microscopy

The emergence of ultrafast electron microscopy (UEM) has enabled the discovery of strongly correlated dynamic mechanisms, including electron–phonon coupling, structural phase transitions, thermal transport, and electromagnetic deflection. Most UEM systems operate stroboscopically, meaning that the technique is susceptible to artifacts, mistakes, and misinterpretation of the data due to extensive experimental effort. In contrast to the ultrafast designation, data acquisition is extraordinarily slow because the electron beam has significantly reduced signal compared to traditional transmission electron microscopy due to pulsing the electron beam. Consequently, the sample may drift, tilt, or undergo irreversible structural changes that are independent of the time-resolved dynamics throughout the experimental time frame. Furthermore, these datasets require significant user interpretation that can be problematic when proper controls are not implemented thoroughly. Here, we demonstrate a new algorithm designed to separate ultrafast structural dynamics from long-term artifacts using a LiNbO 3 sample experiencing electrically driven surface acoustic wave propagation. Additionally, we provide examples of the impact of user bias when analyzing the data and provide a methodology, which enables the extraction of time-resolved responses when the image signal is extraordinarily low. Overall, the goal of this publication is to provide methods that validate the experimental results and reduce researcher biases during UEM data interpretation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Engineering long-lived entanglement through dissipation in quantum hybrid solid-state platforms

Spin squeezing, a form of many-body entanglement, is a crucial resource in quantum metrology and information processing. While experimentally viable protocols for generating stable spin squeezing have been proposed in quantum optics setups, there is growing interest in quantum hybrid solid-state systems as alternative platforms for both engineering and exploring many-body quantum phenomena. In this work, we propose a scheme to generate long-lived spin squeezing in an ensemble of solid-state qubits interacting with electromagnetic noise emitted by a squeezed solid-state bath. We identify the conditions under which quantum correlations within the bath can be transferred to the qubit array, driving it into an entangled state independently of its initial configuration. To assess the experimental feasibility of our approach, we analyze the dynamics of an array of solid-state spin defects coupled to a common ferromagnetic bath, which is driven into a non-equilibrium squeezed state through its interaction with a surface acoustic wave mode. Our results demonstrate that the ensemble can exhibit steady-state spin squeezing under suitable conditions, opening new pathways for the generation of robust many-body entanglement in solid-state spin ensembles.

NV centers↗

Direct Imaging of Resonant Phonon-Magnon Coupling

Detection of phonons is critical for research on the interconversion between resonantly coupled magnons and phonons. Here we report the direct visualization of the resonant coupling of magnons and phonons by microfocused Brillouin light scattering on the Ni/Li Nb O 3 hybrid heterostructure. The static patterns of surface acoustic wave phonons, originating from the interference between the incident wave ψ 0 (A 0 , k, φ 0 ) and reflected wave ψ 1 (A 1 , - k, φ 1 ), can be modulated by magnetic field due to the magnon-phonon coupling. By analyzing the information of phonons obtained from Brillouin spectroscopy, the properties of the magnon system (Ni film), e.g., ferromagnetic resonance field and resonance linewidth, can be determined. The results provide spatially resolved information about phonon manipulation and detection in a coupled magnon-phonon system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Full characterization of ultrathin 5-nm low-k dielectric bilayers: Influence of dopants and surfaces on the mechanical properties

Ultrathin films and multilayers, with controlled thickness down to single atomic layers, are critical for advanced technologies ranging from nanoelectronics to spintronics to quantum devices. However, for thicknesses less than 10 nm, surfaces and dopants contribute significantly to the film properties, which can differ dramatically from that of bulk materials. Therefore, for amorphous films being developed as low dielectric constant interfaces for nanoelectronics, the presence of surfaces or dopants can soften films and degrade their mechanical performance. Here we use coherent short-wavelength light to fully and nondestructively characterize the mechanical properties of individual films as thin as 5 nm within a bilayer. In general, we find that the mechanical properties depend both on the amount of doping and the presence of surfaces. In very thin (5-nm) silicon carbide bilayers with low hydrogen doping, surface effects induce a substantial softening - by almost an order of magnitude - compared with the same doping in thicker (46-nm) bilayers. These findings are important for informed design of ultrathin films for a host of nano- and quantum technologies, and for improving the switching speed and efficiency of next-generation electronics.

36 MATERIALS SCIENCE↗

Static Strain Modelling, Calibration, and Measurements for High-Temperature Wireless SAW Resonator Operation

Static strain measurements are relevant for Integrated System Health Monitoring of civil structures, aircrafts, power plants and advanced manufacturing equipment, with implications for safety, process efficiency, and maintenance costs. Wireless strain sensing is highly desirable where the presence of wires poses significant safety concerns, increases maintenance, and thus overall costs, or where they are not feasible, such as in applications which contain moving parts. This paper presents wireless interrogation of surface acoustic wave resonators (SAWRs) fabricated on langasite (LGS) along Euler angles (0°, 138.5°, 32.9°) and aimed at the detection of static strain at hightemperature (HT, above 100°C). Both commercial HT strain gauges and finite element analysis (FEA Abaqus software) were used and compared for SAWR strain calibration from room temperature (RT) to HT. In addition, this work investigated a compromise between high temperature operation vs. sensitivity based on the thickness of ceramic adhesive used. For instance, a reduction in the adhesive thickness from about 150 μm to 135 μm, resulted in a 39% increase in sensitivity at RT. It was also observed that the sensitivity dropped up to 34% from RT to 200°C. Furthermore, wireless operation, calibration, and increase in sensitivity constitute important advances in the use of LGS SAW devices to monitor static stress in high-temperature harsh environments.

42 ENGINEERING↗

Impact of Thermal Stress on Attachment and Stability of High Temperature Strain Sensors

Static and dynamic strain sensing is required in high-temperature (HT), harsh-environments (HE) for industrial, aerospace, and energy sector applications to ensure equipment and process safety, reduce the cost of operation and maintenance, and increase process efficiency. Challenges that arise in HT HE sensing applications include device mounting, packaging, integrity, and stability to HT HE conditions. In previously reported work, static and dynamic strain surface acoustic wave resonator (SAWR) sensors were fabricated on langasite (LGS) and mounted on Inconel 625 strain beams for wireless testing up to 400°C. In this work, it has been identified that after subjecting the mounted SAWR strain sensor to thermal cycling between 100°C and 425°C, the measured sensitivity to dynamic strain decreased by 73% due to cracking at the adhesive/LGS interface, further deteriorating after additional thermal cycles. Strain modeling of the mounted LGS sensor chip up to 400°C revealed the existence of concentrated strain at the borders of the LGS chip. Microcracks caused by dicing make the chip boarders the most susceptible location for cracks to initiate when the sensor is subjected to thermal stress. In an attempt to mitigate the high strain at the LGS chip borders due to heating, adhesive shaping is proposed in this work. Simulations indicate a strain reduction of 50% at the border is achieved using both circular and triangular adhesive shapes, while also reducing the maximum strain over the entire adhesive/LGS interface by around 30%. Furthermore, the technique is thus promising for improving the integrity, reliability, and stability of static and dynamic strain sensors, particularly while operating under HT HE with several hundreddegree Celsius temperature excursions.

47 OTHER INSTRUMENTATION↗

Temperature and Dynamic Strain Measurements Using a Single SAWR Sensor

Dynamic strain sensing is relevant in numerous applications involving structural health monitoring, condition-based maintenance, operation efficiency preservation, and work environment safety. These sensors are particularly critical for high-temperature (HT) harsh-environment (HE) industries such as aerospace, automotive, power plants, and advanced manufacturing. In HT/HE, sensor implementation and measurement present challenges such as maintaining sensor stability, accounting for temperature cross-sensitivity, providing HT attachment, and packaging of the sensors and system. Surface acoustic wave resonator (SAWR) sensors can address these needs and offer additional benefits such as compact size and wireless interrogation capability. The SAWR sensitivity to dynamic strain is temperature dependent, making it necessary to measure the sensor temperature in order to use the correct dynamic strain calibration curve. In this work, a method for determining the temperature, dynamic strain magnitude, and dynamic strain spectral components using a single SAWR sensor is presented. Here, the established technique for determining operational temperature and dynamic strain magnitude/spectral components using only one SAWR simplifies the sensor measurement system, thus being very attractive for HT /HE applications.

47 OTHER INSTRUMENTATION↗

Irradiation Behavior of Piezoelectric Materials for Nuclear Reactor Sensors

In-situ measurement of surface acoustic wave (SAW) resonators were used to characterize piezoelectric materials behavior in a nuclear reactor environment. Lithium niobate and aluminum nitride devices were tested up to 500°C temperature and 450 kW reactor power (1.9x10 12 n/cm 2 s). The resonant frequency responds to step changes in temperature and power. Materials’ response are inferred from the observed resonant frequency changes, in particular the kinetic behavior is used to determine mechanisms responsible for observed changes. The observed response is attributed to two mechanisms: temperature increase from gamma heating and accumulation of radiation-induced defects. Both of these mechanisms alter the physical properties of the piezoelectric materials, particularly the elastic constants. The demonstrated repeatability and reliability of SAW devices are attractive for sensor applications in extreme environments.

36 MATERIALS SCIENCE↗

Study for identification of Beneficial Uses of Space (BUS). Volume 2: Technical report. Book 1: Sections 1 through 4

Consolidated information is presented for the study whose purpose was to identify products, processes, and services to be produced in future spacecraft environments for direct utilization on earth. Discussion of methodology for selecting from among potential space processing approaches, definition of requirements for experiments and tests needed to acquire sufficient knowledge for proof testing of selected processes, formulation of research and development schedules to achieve proof testing, and documentation of the decision processes involved in the programs are presented. Technology and programmatics are reported for the following select studies: (1) surface acoustic wave components; (2) transparent oxides; (3) high purity tungsten X-ray targets; and (4) high specificity isoenzymes.

Source record↗

The 1975 NASA/ASEE summer faculty fellowship research program

A research program was conducted to further the professional knowledge of qualified engineering and science faculty members, to stimulate an exchange of ideas between participants and NASA engineers and scientists, and to enrich the research activities of the participants' institutions. Abstracts of reports submitted at the end of the program are presented. Topics investigated include multispectral photography, logic circuits, gravitation theories, information systems, fracture mechanics, holographic interferometry, surface acoustic wave technology, ion beams in the upper atmosphere, and hybrid microcircuits.

Source record↗

Methods utilized in evaluating the profitability of commercial space processing

Profitability analysis is applied to commercial space processing on the basis of business concept definition and assessment and the relationship between ground and space functions. Throughput analysis is demonstrated by analysis of the space manufacturing of surface acoustic wave devices. The paper describes a financial analysis model for space processing and provides key profitability measures for space processed isoenzymes.

Bloom, H. L.↗

Convolution using guided acoustooptical interaction in thin-film waveguides

Interaction of two antiparallel acoustic surface waves (ASW) with an optical guided wave has been investigated theoretically as well as experimentally to obtain the convolution of two ASW signals. The maximum time-bandwidth product that can be achieved by such a convolver is shown to be of the order of 1000 or more. The maximum dynamic range can be as large as 83 dB.

Chang, W. S. C.↗

Using SAW Resonators in RF Oscillators

Surface-acoustic-wave (SAW) resonators used as frequency-determining elements in radio-frequency oscillators circuits. Oscillators are frequencymodulated, phase-modulated, or pulse-modulated. SAW resonators are especially applicable to low-power subminiature applications, such as biotelemetry and wind-tunnel instrumentation, where they advantageously replace crystals. Resonators are smaller than crystals and very thin--advantage where small package size is important.

Westbrook, R. M.↗

Wideband optical measurements of ultrasonic pulses

Calibrated masurements of acoustic surface wave pulses by wide bandwidth differential interferometry are described. By interrogating the interference pattern formed by superimposing two optical beams reflected from the surface at slightly separated points, an output signal proportional to instantaneous surface particle displacement is obtained. Response to ideal propagating step function displacements is analyzed and measurements of gated pulses are described.

Claus, R. O.↗

Satellite analog FDMA/FM to digital TDMA conversion

The results of a study which investigated design issues regarding the use of analog to digital (A/D) conversion on board a satellite are presented. The need for A/D, and of course D/A as well, conversion arose from a satellite design which required analog FDMA/FM up and down links to/from a digitally modulated intersatellite link. There are also some advantages when one must interconnect a large number of various spot beams which are using analog, and therefore cannot take advantage of SS/TDMA switching among the beams, thus resulting in low fill factors. Various tradeoffs were performed regarding the implementation of on-board A/D processing, including mass, power, and costs. The various technologies which were considered included flash ADCs, surface acoustic wave (SAW) devices, and digital signal processing (DSP) chips. Impact analyses were also performed to determine the effect on ground stations to convert to digital if the A/D approach were not implemented.

Driggers, T.↗

Phase-Length Optical Phase-Locked-Loop Sensor (PLOPS)

PLOPS system designed to provide high-resolution measurement of change in optical length from optical-system source to any optical reflector, including diffuse reflector. Serves as adjustable optical ruler, providing high resolution in measurements of small and large changes in distance to target. Use is broad and includes most measurement situations requiring information on length, vibration, and their derivatives. Applications include building dynamics, remote sensing of vibrations in such systems as turbine-based machinery, monitoring of structural dynamics, noncontacting sensing of surface contours, measurement of large strains as in earthquake monitoring, measurement of atmospheric dynamics and turbulence, high-resolution sensing of humidity, detection of surface acoustic waves by optical microscopy, and related areas.

Heyman, Joseph S.↗

Spectral analysis, digital integration, and measurement of low backscatter in coherent laser radar

A method of surface acoustic wave (SAW) spectral analysis and digital integration that has been used previously in coherent CW laser work with CO2 lasers at 10.6 microns is described. Expressions are derived for the signal to noise ratio in the measured voltage spectrum with an approximation for the general case and rigorous treatment for the low signal case. The atmospheric backscatter data accumulated by the airborne LATAS (laser true airspeed) coherent laser radar system are analyzed.

Vaughan, J. M.↗

Definition of a near real time microbiological monitor for space vehicles

Efforts to identify the ideal candidate to serve as the biological monitor on the space station Freedom are discussed. The literature review, the evaluation scheme, descriptions of candidate monitors, experimental studies, test beds, and culture techniques are discussed. Particular attention is given to descriptions of five candidate monitors or monitoring techniques: laser light scattering, primary fluorescence, secondary fluorescence, the volatile product detector, and the surface acoustic wave detector.

Kilgore, Melvin V., Jr.↗