Search NASA⌕ Search

SEARCH · Search NASA

Results for “Syringes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

204 records · Page 12

Requalification of historical intermediate level waste (ILW) for the repository KONRAD on basis of non destructive assay (NDA) and re-evaluated nuclide vectors - 15289

The storage facility for ILW of the HDB contains a large number of historical waste products in 200-l drum geometry, which were produced in the 1970's to the 1990's. In the next years more ILW will be treated and stored at HDB, exceeding the storage capacity of the ILW store. All waste products produced at HDB are treated according to the acceptance criteria of the repository KONRAD and are planned to final storage in this repository. In order to qualify the waste materials for final storage in KONRAD and to remove parts of the inventory from the storage chambers this project was started. The main issues of the project, which will be accompanied by the regulator, are product control measures like gas chromatographic analyses of remotely sampled gas syringes and non destructive assay techniques like?-spectrometry and neutron-analytics. The product control is followed by declaration on the basis of re-evaluated nuclide vectors and a repackaging of the drums in licensed containers. The packaging concept includes a 400-l drum as qualified over-pack, because several of the historical drums cannot be qualified as IP-II or type A package. The annual space between the two drums is filled with quartz sand for stability and additional shielding. The drum set is afterwards inserted into a qualified UBA-container provided by GNS. In the case that the product control measures and the reassessment of the declarations result in a violation of the activity limits of the relevant acceptance criteria for KONRAD, the respective drum has to be physically re-qualified after correspondence with the surveillance authorities. This program will be applied to a fraction of approx. 400 canisters, which were selected on the basis of several quality aspects like dose rate below 100 mSv/h, nuclide inventory below 100 A2 according to paragraph 201 of TS-R-1 and well-known waste composition. In the future more waste products will be treated in the same way, if approved containers exist for the inventory. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oxidation of Organics in the Defense Waste Processing Facility Condensate

Defense Waste Processing Facility (DWPF): The state of South Carolina currently holds 35 million gallons of radioactive waste in 51 underground tanks. DWPF was built in an effort to convert the waste into a more stable form. It turns the sludge waste from the tanks into glass, which will keep the waste stable for 10,000 years. Currently, DWPF uses formic acid in its flowsheet and there is one major problem associated with its use: it decomposes into hydrogen, a flammable gas. Glycolic acid, however, has been found as a possible alternative that performs similarly to formic acid but does not directly form hydrogen. One of the main issues with the glycolic acid flowsheet is the potential for there to be glycolate and other organics in DWPF's Recycle Collection Tank (RCT). These organics could lead to hydrogen generation later in the downstream evaporators and must be destroyed in the RCT in order for glycolic acid to be a suitable replacement for formic acid. Oxidants can be added to the RCT to destroy the organics. Two oxidizers, permanganate and Fenton's reagent (iron catalyzed hydrogen peroxide), are possible candidates. Find optimum processing conditions for the oxidation of organic species in a typical RCT simulant. A reactor served as a small-scale version of the RCT. During each run, an RCT simulant with 8 added organics, including glycolate, was created in the reactor. Either permanganate or peroxide was slowly added for each run through a syringe pump. Each experiment lasts 6 hours and a total of 23 runs are scheduled. Variables of Interest: Oxidizer (Permanganate or Peroxide); Temperature (15 deg. C to 50 deg. C); Oxidant addition time (10 mins to 2 hours); Amount of oxidant (1 x to 1.5 x stoichiometric requirements); Solution pH (3 to 13); Glycolate concentration (125 to 250 mg/kg). Offgas Analyzers: Mass spectrometer and FTIR spectrometer. Samples: pulled at 7 different times throughout the run to determine the amount of organic and inorganic carbon and concentrations of various organics through ion chromatography (IC). Only 3 of the runs have been completed at this point, all with permanganate. Based on the first 3 runs, permanganate seems to oxide the majority of the organics and the run at pH 8 and 32.5 deg. C had the most effective oxidation. The rest of the runs will need to be performed to determine the best oxidant and optimum values of the other variables of interest. Once the experiment is completed, DWPF will select one of the oxidants. Testing will continue to determine its performance during foam-over and other non-ideal conditions. Finally, the oxidant will be tested with actual radioactive waste to confirm its effectiveness.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential for Transport of Cesium as Bio-colloids in a High Ionic Strength System

The Waste Isolation Pilot Plant (WIPP) is a deep geologic repository for long-term disposal of transuranic, radioactive waste that is a byproduct from the nation's nuclear defense program. Most likely release scenario → human intrusion (potentially through drilling) (US DOE 1995; 1996). Brine may proceed through the Rustler formation (the most transmissive layer) (Perkins et al., 1999). There is a need to investigate halophilic microbes including their mobility in the Rustler formation and the potential for enhancing transport of cesium as a bio-colloid. Objectives: To quantify the change in mobility of Cs by interaction with microbes (Chromohalobacter) that may be present near Waste Isolation Pilot Plant. What is Chromohalobacter?: a halophilic microbe, isolated from near the WIPP site, able to thrive in the high salt concentrations relevant to the repository. Does the microbe growth phase effect uptake of Cs? Experiments conducted with actively growing and stationary phase Chromohalobacter. Uptake may differ if Cs{sup +} is mistaken for K{sup +} in an actively growing (Log) phase versus stationary phase microbes (not actively reproducing). Materials: 1'' Teflon column packed with 1 gram of dolomite [355-500 μm, CaMg(CO{sub 3}){sub 2}] connected to a syringe pump and fraction collector via Teflon tubing. Chromohalobacter (100 million cells/mL) and dolomite collected near the WIPP. Synthetic brine - 15% NaCl (w/v ∼2.78 M) + 3 mM NaHCO{sub 3}. Methodology: Negative Control 5,000 ppb Cs initially injected into mini-columns with brine. Injection solution was then switched to only brine. Cs Experiments with Stationary Phase Chromo: Set 1: Viable stationary Chromo injected into minicolumns after reaction with 200 ppb Cs. Injection solution was then switched to only brine (without Cs or microbes). Set 2: Stressed stationary Chromo initially injected into mini-columns after reaction with 200 ppb Cs. Then, switched to brine only. Cs Experiments with Log phase Chromo: Set 1: Chromo injected into mini-columns after reaction with 5,000 ppb Cs. Injection then switched to only brine (without Cs or microbes). Set 2: Chromo grown with 5,000 ppb Cs and spiked with additional Cs before injection into columns. Preliminary Conclusions: Cs was not taken up or mobilized by Chromohalobacter in the actively growing or stationary phases or under stressed conditions. Competition may have occurred between Cs and K{sup +} at lower ionic strength, significantly greater concentrations of K{sup +} were present. Results suggest that Chromohalobacter can selectively uptake K{sup +} in the presence of Cs{sup +}. Future Research: K{sup +} and Cs{sup +} uptake will be monitored at high ionic strength in K{sup +} depleted media to consider uptake of Cs in the absence of K.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Medical ice slurry production device

The present invention relates to an apparatus for producing sterile ice slurries for medical cooling applications. The apparatus is capable of producing highly loaded slurries suitable for delivery to targeted internal organs of a patient, such as the brain, heart, lungs, stomach, kidneys, pancreas, and others, through medical size diameter tubing. The ice slurry production apparatus includes a slurry production reservoir adapted to contain a volume of a saline solution. A flexible membrane crystallization surface is provided within the slurry production reservoir. The crystallization surface is chilled to a temperature below a freezing point of the saline solution within the reservoir such that ice particles form on the crystallization surface. A deflector in the form of a reciprocating member is provided for periodically distorting the crystallization surface and dislodging the ice particles which form on the crystallization surface. Using reservoir mixing the slurry is conditioned for easy pumping directly out of the production reservoir via medical tubing or delivery through other means such as squeeze bottles, squeeze bags, hypodermic syringes, manual hand delivery, and the like.

60 APPLIED LIFE SCIENCES↗

Mini-columns for Conducting Breakthrough Experiments: Design and Construction

Experiments with moderately and strongly sorbing radionuclides (i.e., U, Cs, Am) have shown that sorption between experimental solutions and traditional column materials must be accounted for to accurately determine stationary phase or porous media sorption properties (i.e., sorption site density, sorption site reaction rate coefficients, and partition coefficients or K d values). This report details the materials and construction of mini-columns for use in breakthrough columns to allow for accurate measurement and modeling of sorption parameters. Material selection, construction techniques, wet packing of columns, tubing connections, and lessons learned are addressed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A source of experimental underestimation of aerosol bolus deposition

We examined the measurement error in inhaled and exhaled aerosol concentration resulting from the bolus delivery system when small volumes of monodisperse aerosols are inspired to different lung depths. A laser photometer that illuminated approximately 75% of the breathing path cross section recorded low inhaled bolus half-widths (42 ml) and negative deposition values for shallow bolus inhalation when the inhalation path of a 60-ml aerosol was straight and unobstructed. We attributed these results to incomplete mixing of the inhaled aerosol bolus over the breathing path cross section, on the basis of simultaneous recordings of the photometer with a particle-counter sampling from either the center or the edge of the breathing path. Inserting a 90 degrees bend into the inhaled bolus path increased the photometer measurement of inhaled bolus half-width to 57 ml and yielded positive deposition values. Dispersion, which is predominantly affected by exhaled bolus half-width, was not significantly altered by the 90 degrees bend. We conclude that aerosol bolus-delivery systems should ensure adequate mixing of the inhaled bolus to avoid error in measurement of bolus deposition.

Non-NASA Center↗