Search NASA⌕ Search

SEARCH · Search NASA

Results for “TABLE OF ELEMENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Investigations into validation of plutonium solutions for criticality safety analysis

Plutonium solution chemistry is among the most complex of all the elements in the periodic table. Under acidic conditions up to four different oxidation states can be present in significant amounts in a single solution. From the perspective of nuclear criticality safety, accurate information regarding the concentration of plutonium and other constituents in solution must be well-known in order to correctly model plutonium solution systems for analysis. This requires knowledge of the solution system along with the ability to make accurate assumptions and predictions of the chemical and physical properties of the solution system. If neutron transport methods are used to assess subcriticality in a nuclear criticality safety analysis, the models must be compared with benchmark experiments which are similar and the suitability of the computer code system must be quantified. This paper describes some investigations undertaken to support the validation of plutonium solution systems for nuclear criticality safety analysis and how the Whisper sensitivity/uncertainty (S/U) tool can provide information to support validation of such systems. Case study results for various solution systems such as aqueous plutonium nitrate, aqueous plutonium chloride and hypothetical metal-water mixture are presented. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Anisotropic Hexagonal Boron Nitride Nanomaterials - Synthesis and Applications

Boron nitride (BN) is a synthetic binary compound located between III and V group elements in the Periodic Table. However, its properties, in terms of polymorphism and mechanical characteristics, are rather close to those of carbon compared with other III-V compounds, such as gallium nitride. BN crystallizes into a layered or a tetrahedrally linked structure, like those of graphite and diamond, respectively, depending on the conditions of its preparation, especially the pressure applied. Such correspondence between BN and carbon readily can be understood from their isoelectronic structures [1, 2]. On the other hand, in contrast to graphite, layered BN is transparent and is an insulator. This material has attracted great interest because, similar to carbon, it exists in various polymorphic forms exhibiting very different properties; however, these forms do not correspond strictly to those of carbon. Crystallographically, BN is classified into four polymorphic forms: Hexagonal BN (h-BN) (Figure 1(b)); rhombohedral BN (r-BN); cubic BN (c-BN); and wurtzite BN (w-BN). BN does not occur in nature. In 1842, Balmain [3] obtained BN as a reaction product between molten boric oxide and potassium cyanide under atmospheric pressure. Thereafter, many methods for its synthesis were reported. h-BN and r-BN are formed under ambient pressure. c-BN is synthesized from h-BN under high pressure at high temperature while w-BN is prepared from h-BN under high pressure at room temperature [1]. Each BN layer consists of stacks of hexagonal plate-like units of boron and nitrogen atoms linked by SP{sup 2} hybridized orbits and held together mainly by Van der Waals force (Fig 1(b)). The hexagonal polymorph has two-layered repeating units: AA'AA'... that differ from those in graphite: ABAB... (Figure 1(a)). Within the layers of h-BN there is coincidence between the same phases of the hexagons, although the boron atoms and nitrogen atoms are alternatively located along the c-axis. The rhombohedral system consists of three-layered units: ABCABC..., whose honeycomb layers are arranged in a shifted phase, like as those of graphite. Reflecting its weak interlayer bond, the h-BN can be cleaved easily along its layers, and hence, is widely used as a lubricant material. The material is stable up to a high temperature of 2300 C before decomposition sets in [2] does not fuse a nitrogen atmosphere of 1 atm, and thus, is applicable as a refractory material. Besides having such properties, similar to those of graphite, the material is transparent, and acts as a good electric insulator, especially at high temperatures (10{sup 6} {Omega}m at 1000 C) [1]. c-BN and w-BN are tetrahedrally linked BN. The former has a cubic sphalerite-type structure, and the latter has a hexagonal wurtzite-type structure. c-BN is the second hardest known material (the hardest is diamond), the so-called white diamond. It is used mainly for grinding and cutting industrial ferrous materials because it does not react with molten iron, nickel, and related alloys at high temperatures whereas diamond does [1]. It displays the second highest thermal conductivity (6-9 W/cm.deg) after diamond. This chapter focuses principally upon information about h-BN nanomaterials, mainly BN nanotubes (BNNTs), porous BN, mono- and few-layer-BN sheets. There are good reviews book chapters about c-BN in [1, 4-6].

36 MATERIALS SCIENCE↗

Ion production from solid state laser ion sources

Laser ion sources based on resonant excitation and ionization of atoms are well-established tools for selective and efficient production of radioactive ion beams. Recent developments are focused on the use of the state-of-the-art all solid-state laser systems. To date, 35 elements of the periodic table are available from laser ion sources based on tunable Ti:sapphire lasers. Recent progress in this field regarding the establishment of suitable optical excitation schemes for Ti:sapphire lasers are reported.

07 ISOTOPE AND RADIATION SOURCES↗

Cold cathodes for sealed-off CO2 lasers

Cold cathodes for CO2 lasers should possess a very low sputtering rate, have a minimum of negative ions in the sputtering products, and consume no oxygen. These conditions can be satisfied by selecting cathode materials from those elements of group I in the periodic table which form semiconducting oxide layers and then exposing these elements to a reducing gas mixture. Experimental results show that silver, internally oxidized silver-copper alloys, and pure copper satisfy most of these requirements in He-CO2-CO-Xe gas mixtures. Infrared CO and CO2 gas analysis performed on simple gas discharge tubes using such cathodes indicate that laser lives of 10,000 hr can be expected.

Hochuli, U. E.↗

Full spectrum optical constant interface to the Materials Project

Optical constants characterize the interaction of materials with light and are important properties in material design. Here we present a Python-based Corvus workflow for simulations of full spectrum optical constants from the visible and ultraviolet to hard x-ray wavelengths based on the real-space Green’s function code FEFF10 and structural data from the Materials Project (MP). The Corvus workflow manager and its associated tools provide an interface to FEFF10 and the MP database. The workflow parallelizes the FEFF computations of optical constants over all absorption edges for each material in the MP database specified by a unique MP-ID. The workflow tools determine the distribution of computational resources needed for that case. Similarly, the optical constants for selected sets of materials can be computed in a single-shot. Additionally, to illustrate the approach, we present results for several elemental solids in the periodic table, as well as a sample compound, and compare our predictions with experimental results. In addition, we provide a database of calculated results for all elements for which there is a stable elemental solid at standard conditions available in the Materials Project database. As in x-ray absorption spectra, these results are interpreted in terms of an atomic-like background and fine-structure contributions.

36 MATERIALS SCIENCE↗

2019 UNESCO International Year of Periodic Table

Periodic Law : periodic dependence of element’s properties on atomic mass Presented March 1 st , 1869 Initially : only 63 elements Predicted and discovered : Ga (1875), Sc (1879), Ge (1885) < >

43 PARTICLE ACCELERATORS↗

Average bond energies between boron and elements of the fourth, fifth, sixth, and seventh groups of the periodic table

The average bond energies D(gm)(B-Z) for boron-containing molecules have been calculated by the Pauling geometric-mean equation. These calculated bond energies are compared with the average bond energies D(exp)(B-Z) obtained from experimental data. The higher values of D(exp)(B-Z) in comparison with D(gm)(B-Z) when Z is an element in the fifth, sixth, or seventh periodic group may be attributed to resonance stabilization or double-bond character.

Altshuller, Aubrey P↗

Modal Test and Model Correlation of NASA Plum Brook Station Mechanical Vibration Facility Head Expander –Lessons Learned from the Perspective of an Early-Career Engineer

In preparation for the Sierra Nevada Corporation’s (SNC) Dream Chaser spacecraft vibration test campaign at the Mechanical Vibration Facility (MVF) at NASA Plum Brook Station (PBS) in Sandusky, Ohio, a test-verified model of MVF is needed in order to be able to perform accurate pretest analysis used for determining response limits and abort levels. MVF was designed to vibration test MPCV Orion and was used to perform the system level vibration test of the European Service Module Structural Test Article (E-STA) in 2016. MVF is comprised of an 18 ft diameter annulus table that is driven with sixteen hydraulic vertical actuator assemblies and four hydraulic horizontal actuator assemblies, which allow it to perform single axis vibration testing in the vertical axis and in each of the two orthogonal horizontal axes without the need for reconfiguring the test article. A head expander for the MVF Table has been designed and built that fills in the center opening providing a continuous flat mounting surface with a maximum diameter of 16.25feet that expands the vibration testing capabilities of MVF. The MVF Table with this head expander will be used during the SNC Dream Chaser spacecraft vibration test campaign. Therefore, a critical element in a test-verified model of the MVF will be a test correlated finite element model (FEM) of the head expander. To obtain this, engineers from the Structural Dynamics Lab (SDL) at NASA Glenn Research Center (GRC) in Cleveland, Ohio performed a modal pretest analysis, conducted a modal test in July 2019, and most recently correlated the head expander finite element model to the modal test data up to 300 Hz. From the initial test preparations to the final delivery of a correlated finite element model, all efforts mentioned were led by the same early-career engineers at NASA GRC. From the viewpoint of an early-career engineer, lessons learned about modal pretest analysis, modal testing, and finite element model correlation of the MVF Table expander head will be presented and discussed. This will include the importance of understanding the limitations of using uncorrelated finite element models in the modal pretest analysis and planning, the importance of orthogonality metrics in judging adequacy and accuracy of test mode shapes, and the importance of having the FEM match the as built hardware in the model correlation effort.

Emma L Pierson↗

Adsorption of the Lighter Homologs of Element 104 and Element 105 on DGA Resin from Various Mineral Acids

The goal of studying transactinide elements is to further understand the fundamental principles that govern the periodic table. The current periodic table arrangement allows for the prediction of the chemical behavior of elements. The correct position of a transactinide element can be assessed by investigating its chemical behavior and comparing it to that of the homologs and pseudo-homologs of a transactinide element. Homologs of a transactinide element are the elements in the same group of the periodic table as the transactinide. A pseudo-homolog of a transactinide element is an element with a similar main oxidation state and similar ionic radius to the transactinide element. For example, the homologs of rutherfordium, Rf, are titanium, zirconium and hafnium (Ti, Zr and Hf); the pseudo homologs of Rf are thorium, Th, and plutonium, Pu. Understanding the chemical behavior of a transactinide element compared to its homologs and pseudo-homologs also allows for the assessment of the role of relativistic effects. Relativistic effects occur when the velocity of the s orbital electrons closest to the nucleus approaches the speed of light. These electrons approach the speed of light because they have no orbital momentum. This causes two effects, first there is in a decrease in Bohr radius of the inner electronic orbitals because of this there is an increase in particle mass. A contraction of outer s and p orbitals is also seen. The contraction of these orbitals results in an energy destabilization of the outer most shell, in the case of transactinides this would be the 5f and 6d orbitals. The outer most d shell and all f shells can also experience a radial expansion due to these orbitals being screened from the effective nuclear charge. Another relativistic effect is the 'spin-orbit splitting' for p, d and f orbitals into j = 1 {+-} 1/2 states. Where j is the total angular momentum vector and 1 is angular quantum number. All of these effects have the same order of magnitude and increase roughly according to Z. This feature is what makes studying the heavy elements so interesting because the chemical properties of transactinide elements should strongly exhibit these effects. For this work the terms heavy element and transactinide elements will be used interchangeably and are defined as elements with an atomic number greater than 103, Z > 103. In order to study the transactinide elements they must be isolated once they have been produced and transported to a chemistry apparatus. The transactinide elements are produced either via 'hot' or 'cold' fusion reactions. 'Hot' fusion reactions result in excitation energies of the compound nucleus of 40-50 MeV and occur when an actinide target nuclei fuse with a projectile with A < 40, where A is the atomic mass number. 'Cold' fusion results in excitation energies of 10-15 MeV. Cold fusion conditions tend to occur when a target of a spherical nuclei (Pb or Bi) is bombarded with a heavy projectile (A > 40). Hot fusion generally leads to neutron rich isotopes and cold fusion tends to produce a compound nucleus that emits 1-2 neutrons upon de-excitation. If a sufficiently thin target is employed, then the products of the nuclear reaction will recoil out of the target and can either be transported to the chemistry setup, e.g. using a gas jet, or trapped by implementing them on a catcher. An example for a catcher setup using a copper block as a catcher is described here. The copper block is placed behind the target during the irradiation and all nuclei recoiling from the target position will implant themselves in the block. The copper block is subsequently dismounted and sputter cleaned. It is then shaved with a micro-lathe. The 7-10 {micro}m copper shavings are then subjected to chemical separation. The copper is dissolved in aqua regia. Lanthanum carrier is added to the aqua regia to precipitate tri-, tetra- and penta- valent cations when ammonium hydroxide is added. The precipitate is then washed and converted to the nitrate form. This solution is then added onto a cation exchange column, the eluent is deposited and dried on a polypropylene film and then counted on solid state detectors. There are several challenges when studying the chemical behavior of transactinide elements. The first challenge is the low production rate of transactinides. Transactinides are produced on an atom-at-a-time basis, meaning that only one atom is ever available for chemical study. Because of this the chemical system being used must be selective for only one chemical state. The second challenge in transactinide chemistry is the short half-lives of the elements. Half-lives of the transactinides range from nanoseconds to a few hours. This leads to the need for fast chemistry. Another challenge is the need for a high degree of separation from interfering radionuclides so that the event with the transactinide element can be detected.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

G4CEP: A G4 theory modification by including pseudopotential for molecules containing first-, second- and third-row representative elements

The G4CEP composite method was developed from the respective G4 all-electron version by considering the implementation of compact effective pseudopotential (CEP). The G3/05 test set was used as reference to benchmark the adaptation by treating in this work atoms and compounds from the first and second periods of the periodic table, as well as representative elements of the third period, comprising 440 thermochemical data. G4CEP has not reached a so high level of accuracy as the G4 all-electron theory. G4CEP presented a mean absolute error around 1.09 kcal mol{sup −1}, while the original method presents a deviation corresponding to 0.83 kcal mol{sup −1}. The similarity of the optimized molecular geometries between G4 and G4CEP indicates that the core-electron effects and basis set adjustments may be pointed out as a significant factor responsible for the large discrepancies between the pseudopotential results and the experimental data, or even that the all-electron calculations are more efficient either in its formulation or in the cancellation of errors. When the G4CEP mean absolute error (1.09 kcal mol{sup −1}) is compared to 1.29 kcal mol{sup −1} from G3CEP, it does not seem so efficient. However, while the G3CEP uncertainty is ±4.06 kcal mol{sup −1}, the G4CEP deviation is ±2.72 kcal mol{sup −1}. Therefore, the G4CEP theory is considerably more reliable than any previous combination of composite theory and pseudopotential, particularly for enthalpies of formation and electron affinities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Table of Standard Atomic Weights—an exercise in consensus

The present Table of Standard Atomic Weights (TSAW) of the elements is perhaps one of the most familiar datasets in science. Unlike most parameters in physical science whose values and uncertainties are evaluated using the “Guidelines for Uncertainty in Measurement” (GUM), the majority of standard atomic-weight values and their uncertainties are consensus values, not GUM-evaluated values. The Commission on Isotopic Abundances and Atomic Weights of the International Union of Pure and Applied Chemistry (IUPAC) regularly evaluates the literature for new isotopic-abundance measurements that can lead to revised standard atomic-weight values, A r (E) for element E. The Commission strives to provide utmost clarity in products it disseminates, namely the TSAW and the Table of Isotopic Compositions of the Elements (TICE). In 2016, it was recognized by the Commission that a guideline recommending expression of uncertainty listed in parentheses following the standard atomic-weight value, e.g. A r (Se) = 78.971(8), is not in accord with the GUM, which suggests that this parenthetic notation be reserved to express standard uncertainty, not the expanded uncertainty used in the TSAW and TICE. In 2017, to eliminate this noncompliance with the GUM, a new format was adopted in which the uncertainty value is specified by the plus-minus symbol, e.g. A r (Se) = 78.971 ± 0.008. To clarify the definition of uncertainty, a new footnote has been added to the TSAW. This footnote emphasizes that an atomic-weight uncertainty is a consensus (decisional) uncertainty. Not only has the Commission shielded users of the TSAW and TICE from unreliable measurements that appear in the literature as a result of unduly small uncertainties, but the aim of IUPAC has been fulfilled by which any scientist, taking any natural sample from commerce or research, can expect their sample atomic weight to lie within A r (E) ± its uncertainty almost all of the time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A finite-element method for large-amplitude, two-dimensional panel flutter at hypersonic speeds

The nonlinear flutter behavior of a two-dimensional panel in hypersonic flow is investigated analytically. An FEM formulation based unsteady third-order piston theory (Ashley and Zartarian, 1956; McIntosh, 1970) and taking nonlinear structural and aerodynamic phenomena into account is derived; the solution procedure is outlined; and typical results are presented in extensive tables and graphs. A 12-element finite-element solution obtained using an alternative method for linearizing the assumed limit-cycle time function is shown to give predictions in good agreement with classical analytical results for large-amplitude vibration in a vacuum and large-amplitude panel flutter, using linear aerodynamics.

Mei, Chuh↗

IUPAC Periodic Table of Isotopes for the Educational Community

John Dalton first proposed the concept of atomic weights of the elements in the first decade of the nineteenth century. These atomic weights of the chemical elements were thought of as constants of nature, similar to the speed of light. Dmitri Mendeleev arranged the atomic weights of the elements in ascending order of value and used the systematic variation of their chemical properties to produce his Periodic Table of the Elements in 1869. Measurement of atomic weight values became an important chemical activity for a century and a half. Theodore Richards received a Noble Prize for his work in this area. In 1913, Fredrick Soddy found a species of radium, which had an atomic weight value of 228, compared to the familiar radium gas value of 226. Soddy coined the term 'isotope' (Greek for 'in the same place') to account for this second atomic weight value in the radium position of the Periodic Table. Both of these isotopes of radium are radioactive. Radioactive isotopes are energetically unstable and will decay (disintegrate) over time. The time it takes for one half of a sample of a given radioactive isotope to decay is the half-life of that isotope. In addition to having different atomic weight values, radium-226 and radium-228 also have different half-life values. Around the same time as Soddy's work, J.J. Thomson (discoverer of the electron) identified two stable (non-radioactive) isotopes of the same element, neon. Over the next 40 years, the majority of the known chemical elements were found to have two or more stable (or long-lived radioactive isotopes that contribute significantly to the determination of the atomic weights of the elements).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Table Mountain 8-mm wavelength interferometer

A two-element radio interferometer operating at 8.33-mm wavelength has been developed at the Jet Propulsion Laboratory's Table Mountain Observatory near Wrightwood, CA. The interferometer employs a 5.5-m and a 3-m diameter antenna on an east-west baseline of 60 or 120 m, yielding fringe spacings at transit of 28 or 14 arcsec, respectively. The broad intermediate-frequency bandpass of 100-350 MHz and the system noise temperature of 500 K provide high sensitivity for the measurement of continuum sources. The interferometer has been used for high-resolution studies of the planets and the sun, and it is currently being adapted to study solar flare emissions at high spatial and time resolution.

Janssen, M. A.↗

Ultraminiature X-ray fluorescence spectrometer for in-situ geochemical analysis on Mars.

A spectrometer based upon the X-ray fluorescence method of elemental analysis has been developed in an ultraminiature, rugged form suitable for a spacecraft mission to Mars. The instrument employs two radioisotope sources (Fe-55 and Cd-109) which irradiate adjacent areas on a regolith sample. Fluorescent X rays emitted by the sample are detected by four thin-window proportional counters. Using pulse-height discrimination, the energy spectra are determined. Virtually all elements above sodium in the periodic table are detected if present at sufficient levels. Minimum detection limits range from 30 ppm to 2% depending upon the element and the matrix. For most elements, they are below 0.5%. Accuracies also depend upon the matrix, but are generally better than plus or minus 0.5% for all elements of atomic number greater than 14. Elements below sodium are also detected, but as a single group. Ambiguities of identification of the elements producing the observed spectra are minimal.

Clark, B. C.↗

Design of a lens table for a double toroidal electron spectrometer

We report here on the method we developed to build a lens table for a four-element electrostatic transfer lens operated together with a double toroidal electron energy analyzer designed by one of us, and whose original design and further improvements are described in detail in Miron et al. [Rev. Sci. Instrum. 68, 3728 (1997)] and Le Guen et al. [Rev. Sci. Instrum. 73, 3885 (2002)]. Both computer simulations and laboratory instrument tuning were performed in order to build this lens table. The obtained result was tested for a broad range of electron kinetic energies and analyzer pass energies. Based on this new lens table, allowing to easily computer control the spectrometer working conditions, we could routinely achieve an electron energy resolution ranging between 0.6% and 0.8% of the analyzer pass energy, while the electron count rate was also significantly improved. The establishment of such a lens table is of high importance to relieve experimentalists from the tedious laboring of the lens optimization, which was previously necessary prior to any measurement. The described method can be adapted to any type of electron/ion energy analyzer, and will thus be interesting for all experimentalists who own, or plan to build or improve their charged particle energy analyzers.

43 PARTICLE ACCELERATORS↗

Development of an X-ray surface analyzer for planetary exploration

An ultraminiature X-ray fluorescence spectrometer was developed which can obtain data on element composition not provided by present spacecraft instrumentation. The apparatus employs two radioisotope sources (Fe-55 and Cd-109) which irradiate adjacent areas on a soil sample. Fluorescent X-rays emitted by the sample are detected by four thin-window proportional counters. Using pulse-height discrimination, the energy spectra are determined. Virtually all elements above sodium in the periodic table are detected if present at sufficient levels. Minimum detection limits range from 30 ppm to several percent, depending upon the element and the matrix. For most elements, they are below 0.5 percent. Accuracies likewise depend upon the matrix, but are generally better than plus or minus 0.5 percent for all elements of atomic number greater than 14. Elements below sodium are also detected, but as a single group.

Clark, B. C.↗