Search NASA⌕ Search

SEARCH · Search NASA

Results for “TAPE RECORDER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

CID-720 aircraft Langley Research Center preflight hardware tests: Development, flight acceptance and qualification

The testing conducted on LaRC-developed hardware for the controlled impact demonstration transport aircraft is discussed. To properly develop flight qualified crash systems, two environments were considered: the aircraft flight environment with the focus on vibration and temperature effects, and the crash environment with the long pulse shock effects. Also with the large quantity of fuel in the wing tanks the possibility of fire was considered to be a threat to data retrieval and thus fire tests were included in the development test process. The aircraft test successfully demonstrated the performance of the LaRC developed heat shields. Good telemetered data (S-band) was received during the impact and slide-out phase, and even after the aircraft came to rest. The two onboard DAS tape recorders were protected from the intense fire and high quality tape data was recovered. The complete photographic system performed as planned throughout the 40.0 sec of film supply. The four photo power distribution pallets remained in good condition and all ten onboard 16 mm high speed (400 frames/sec) cameras produced good film data.

Pride, J. D.↗

Engineering studies of vectorcardiographs in blood pressure measuring systems, appendix 3

The following subjects were covered: (1) ASM80 manual, (2) signal preprocessing as an aid to on-line EKG analysis, and (3) high speed evaluation of magnetic tape recordings of electrocardiograms. A description of the ASM80 symbolic assembly program for the INTEL 8080 microprocessor and a user's manual were presented. The capability of three redundancy reduction algorithms to produce adequate representations of electrocardiographic data was examined. A hardware device was constructed which carried out zero order interpolation on a signal. Examination of the zero order interpolators reconstructed signal indicated that this representation was adequate for analysis of rhythm. A system to analyze magnetic tapes of electrocardiograms recorded over 24 hour intervals was designed. The recordings are sampled 200 times per second using a Nova computer and a special interface system. This system was tested on several recordings of clinical data, containing over 75 premature ventricular contractions, each one of which was flagged.

Mark, R. G.↗

Skylab 2 ground winds data reduction and statistical analysis

A ground winds test was conducted on the Skylab 2 spacecraft in a subsonic wind tunnel and the results were tape recorded for analysis. The data reduction system used to analyze the tapes for full scale, first and second mode bending moments, or acceleration plots versus dynamic pressure or wind velocity is explained. Portions of the Skylab 2 tape data were analyzed statistically in the form of power spectral densities, autocorrelations, and cross correlations to introduce a concept of using system response decay as a measure of linear system damping.

Source record↗

Work on Planetary Atmospheres and Planetary Atmosphere Probes

A major objective of the grant was to complete the fabrication, test, and evaluation of the atmosphere structure experiment on the Galileo Probe, and to receive, analyze, and interpret data received from the spacecraft. The grantee was competitively selected to be Principal Investigator of Jupiter's atmosphere structure on the Galileo Probe. His primary motivation was to learn as much as possible about Jupiter's atmosphere by means of a successful atmosphere structure experiment, and to support the needs and schedule of the Galileo Project. After a number of launch delays, the Flight instrument was shipped to Kennedy Space Center 2 years after the start of this collaboration, on April 14, 1989, at which time it was determined from System level tests of the ASI on the Probe that the instrument was in good working order and ready for flight. The spacecraft was launched on October 18, 1989. Data analysis of test and calibration data taken over a period of years of instrument testing was continued in preparation for the encounter. The initial instrument checkout in space was performed on October 26, 1989. The data set received by telemetry was thoroughly analyzed, and a report of the findings was transmitted to the Probe Operations Office on Feb. 28, 1990. Key findings reported were that the accelerometer biases had shifted by less than 1 mg through launch and since calibration at Bell Aerospace in 1983; accelerometer scale factors, evaluated by means of calibration currents, fell on lines of variation with temperature established in laboratory calibrations; pressure sensor offsets, correlated as a function of temperature, fell generally within the limits of several years of ground test data; atmospheric and engineering temperature sensor data were internally consistent within a few tenths of a degree; and the instrument electronics performed all expected functions without any observable fault. Altogether, this checkout was highly encouraging of the prospects of instrument performance, although performed greater than 5 years prior to Jupiter encounter. Capability of decoding the science data from the Experiment Data Record to be provided at encounter was developed and exercised using the tape recording of the first Cruise Checkout data. A team effort was organized to program the selection and combination of data words defining pressure, temperature, acceleration, turbulence, and engineering quantities; to apply decalibration algorithms to convert readings from digital numbers to physical quantities; and to organize the data into a suitable printout. A paper on the Galileo Atmosphere Structure Instrument was written and submitted for publication in a special issue of Space Science Reviews. At the Journal editor's request, the grantee reviewed other Probe instrument papers submitted for this special issue. Calibration data were carefully taken for all experiment sensors and accumulated over a period of 10 years. The data were analyzed, fitted with algorithms, and summarized in a calibration report for use in analyzing and interpreting data returned from Jupiter's atmosphere. The sensors included were the primary science pressure, temperature, and acceleration sensors, and the supporting engineering temperature sensors. This report was distributed to experiment coinvestigators and the Probe Project Office.

Seiff, Alvin↗

A solid state data recorder for spacecraft telemetry applications

A solid state data recorder (SSDR) has been developed which offers a high-reliability alternative to tape recorders in many spacecraft telemetry applications. The storage medium used in this recorder was ferrimagnetic garnet films supporting nonvolatile magnetic bubble domains. The recorder was designed using modular construction consisting of a digital control unit, power supply, and two memory modules. A prototype SSDR has been fabricated which is designed for 100-million bits of storage but was populated with 128 chips for a 13-million bit capacity. Preliminary tests indicate satisfactory operation.

Stermer, R. L., Jr.↗

Radio frequency baseband recording technique

Technique uses a helical-scan video recorder with auxiliary signal-conditioning equipment to provide an inexpensive, high-capacity magnetic tape recording of a 112 channel, phase-locked, multiplexed, baseband signal.

Heckman, D. C.↗

A slow-speed multiple-channel analog-to-digital data logging system

The system was developed to record from one up to a maximum of sixteen channels of analog data onto magnetic tape. Each analog channel of data can be sampled at rates of 1, 2, 6, 12, or 60 times per minute. The system is divided into three subunits: a digital clock, an incremental magnetic tape recorder, and a sequential converter. The interfacing requirements of these subunits are presented.

Lloyd, T. C.↗

Generating Multiple Calibrating Voltages Simultaneously

Calibrating unit containing signal generator controlled by microprocessor puts out ac signals of known voltages on fifty channels simultaneously. Signals used to calibrate high-frequency tape recorder channels for multiple, ac-coupled strain gauges simultaneously. Calibrating voltage required on each tape channel determined by remote computer, and corresponding data and commands transmitted to microprocessor via modems.

Dutreix, Lionel J.↗

Description and availability of airborne Doppler radar data

An airborne, forward-looking, pulse, Doppler radar has been developed in conjunction with the joint FAA/NASA Wind Shear Program. This radar represents a first in an emerging technology. The radar was developed to assess the applicability of an airborne radar to detect low altitude hazardous wind shears for civil aviation applications. Such a radar must be capable of looking down into the ground clutter environment and extracting wind estimates from relatively low reflectivity weather targets. These weather targets often have reflectivities several orders of magnitude lower than the surrounding ground clutter. The NASA radar design incorporates numerous technological and engineering achievements in order to accomplish this task. The basic R/T unit evolved from a standard Collins 708 weather radar, which supports specific pulse widths of 1-7 microns and Pulse Repetition Frequencies (PRF) of less than 1-10 kHz. It was modified to allow for the output of the first IF signal, which fed a NASA developed receiver/detector subsystem. The NASA receiver incorporated a distributed, high-speed digital attenuator, producing a range bin to range bin automatic gain control system with 65 dB of dynamic range. Using group speed information supplied by the aircraft's navigation system, the radar signal is frequency demodulated back to base band (zero Doppler relative to stationary ground). The In-phase & Quadrature-phase (I/Q) components of the measured voltage signal are then digitized by a 12-bit A-D converter (producing an additional 36 dB of dynamic range). The raw I/Q signal for each range bin is then recorded (along with the current radar & aircraft state parameters) by a high-speed Kodak tape recorder.

Harrah, S. D.↗

Technical and investigative support for high density digital satellite recording systems

Dropout and defect classification are discussed with emphasis on how surface defects responsible for electronic dropouts were identified, what affect various defects could have on the application of tapes to satellite tape recorders (STR), and what type of defects might be field correctable after production of the tape but prior to installation in the STR.

Schultz, R. A.↗

Morphological Evolution of Directional Solidification Interfaces in Microgravity: An Analysis of Model Experiments Performed on the International Space Station

A series of experiments performed using the Pore Formation and Mobility Investigation (PFMI) apparatus within the glovebox facility (GBX) on board the International Space Station (ISS) has provided video images of the morphological evolution of a three-dimensional interface in a diffusion controlled regime. The experimental samples were prepared on ground by filling glass tubes, 1 cm ID and approximately 30 cm in length, with "alloys" of succinonitrile (SCN) and water in an atmosphere of nitrogen at 450 millibar pressure. The compositions of the samples processed and analyzed are 0.25,0.5 and 1.0 wt% water. Experimental processing parameters of temperature gradient and translation speed, as well as camera settings, were remotely monitored and manipulated from the ground Telescience Center (TSC) at the Marshall !3pace Flight Center. During the experiments, the sample was first subjected to a unidirectional melt back, generally at 10 microns per second, with a constant temperature gradient ahead of the melting interface. Following the melt back, the interface was allowed to stabilize before translation is initiated. The temperatures in the sample were monitored by six in situ thermocouples and the position is monitored by an optical linear encoder. For the experiments performed and analyzed, the gradients ranged from 2.5 - 3.3 K/mm and the initial pulling velocities ranged from 0.7 micron per second to 1 micron per second with subsequent transition velocities of up to 100 microns per second. The data provided by the PFMI for analysis includes near-real-time (NRT) video captured on the ground during the experiment runs, ISS Video Tape Recorder (VTR) data dumped from the VTR at the end of the experiment run and recorded on the ground, telemetry data including temperature and position measurements, and limited flight HI-8 tapes in 2 camera views of experiment runs for which tapes have been returned to the investigators from ISS. Because of limited down mass from the ISS, the majority of the initial analysis has been performed using the NRT and VTR video data but will be supplemented with the HI-8 video as it becomes available. hardware and procedures required to prepare samples for correlation to flight samples is described. Using this ground-based system, a series of experiments have been performed for direct comparison with the flight data. The results of these comparisons as well as implications to future microgravity experiments are presented and discussed. A ground-based thin-sample directional solidification system as well as all associated

Strutzenberg, Louise L.↗

Digital data detection and synchronization

The primary accomplishments have been in the analysis and simulation of receivers and bit synchronizers. It has been discovered that tracking rate effects play, a rather fundamental role in both receiver and synchronizer performance, but that data relating to recorder time-base-error, for the proper characterization of this phenomenon, is in rather short supply. It is possible to obtain operationally useful tape recorder time-base-error data from high signal-to-noise ratio tapes using synchronizers with relatively wideband tracking loops. Low signal-to-noise ratio tapes examined in the same way would not be synchronizable. Additional areas of interest covered are receiver false lock, cycle slipping, and other unusual phenomena, which have been described to some extent in this and earlier reports and simulated during the study.

Noack, T. L.↗

Magellan Recorder Data Recovery Algorithms

This paper describes algorithms implemented by the Magellan High Rate Processor to recover radar data corrupted by the failure of an onboard tape recorder that dropped bits. For data with error correction coding, an algorithm was developed that decodes data in the presence of bit errors and missing bits.

Error↗

Low-power portable geophysical data acquisition system and its use in geomagnetic measurements

A low-power portable data acquisition system presently in use for geomagnetic measurements is described. The system is composed of a data-processing system containing a low-power microprocessor, a 9-track digital tape recorder, and a rechargeable battery pack. The magnetometer is a low-power three axis fluxgate design. Under program control the data processing system keeps track of time of day and date, samples three analog magnetometer outputs at intervals of either 0.4 or 2 s, digitizes the data to 15-bit resolution, and, depending upon relative magnetic activity, decides upon data compression to increase the tape storage capacity. It also monitors and records internal voltages and provides self-checking functions which may be monitored through a visual readout on the control panel. The system is mounted in a rugged, weather-tight carrying case suitable for use outdoors with minimal protection. The system, including magnetometer, uses 1.6-W power and can store 5.7 Mbytes of data.

Medford, L. V.↗

Computer program compatible with a laser nephelometer

The laser nephelometer data system was updated to provide magnetic tape recording of data, and real time or near real time processing of data to provide particle size distribution and liquid water content. Digital circuits were provided to interface the laser nephelometer to a Data General Nova 1200 minicomputer. Communications are via a teletypewriter. A dual Linc Magnetic Tape System is used for program storage and data recording. Operational programs utilize the Data General Real-Time Operating System (RTOS) and the ERT AIRMAP Real-Time Operating System (ARTS). The programs provide for acquiring data from the laser nephelometer, acquiring data from auxiliary sources, keeping time, performing real time calculations, recording data and communicating with the teletypewriter.

Paroskie, R. M.↗