Soft Matter Thermal and Mechnical Devices

The participant company, Treau, makes homes and buildings more comfortable with quiet, energy efficient, and easy to install heating and cooling systems. They entered the Cyclotron Road program with an idea for a heat exchanger and compressor and a general idea that the building heating and cooling sector was the best first target market. While at Cyclotron Road, they used the Cyclotron Road program staff and Berkeley Lab expertise to better understand the needs of the heating and cooling equipment market. This was critical to understand who the end customer was, and what features were needed in this market. They were then able to conduct product development with this target market/customer in mind. The Cyclotron Road program was also critical in building a manufacturing and scale-up plan that allowed the participant to build a credible growth and fundraising strategy. By the end of the program, the participant had a working prototype testing at Berkeley Lab’s HVAC testing facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Non-invasive (non-contact) measurements of human thermal physiology signals and thermal comfort/discomfort poses -A review

Heating, ventilation and air-conditioning (HVAC) systems have been adopted to create comfortable, healthy and safe indoor environments. In the control loop, the technical feature of the human demand-oriented supply can help operate HVAC effectively. Among many technical options, real time monitoring based on feedback signals from end users has been frequently reported as a critical technology to confirm optimizing building performance. Recent studies have incorporated human thermal physiology signals and thermal comfort/discomfort status as real-time feedback signals. A series of human subject experiments used to be conducted by primarily adopting subjective questionnaire surveys in a lab-setting study, which is limited in the application for reality. With the help of advanced technologies, physiological signals have been detected, measured and processed by using multiple technical formats, such as wearable sensors. Nevertheless, they mostly require physical contacts with the skin surface in spite of the small physical dimension and compatibility with other wearable accessories, such as goggles, and intelligent bracelets. Most recently, a low cost small infrared camera has been adopted for monitoring human facial images, which could detect the facial skin temperature and blood perfusion in a contactless way. Also, according to latest pilot studies, a conventional digital camera can generate infrared images with the help of new methods, such as the Euler video magnification technology. Human thermal comfort/discomfort poses can also be detected by video methods without contacting human bodies and be analyzed by the skeleton keypoints model. Here, new sensing technologies were summarized, their cons and pros were discussed, and extended applications for the demand-oriented ventilation were also reviewed as potential development and applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Comparative Analysis of HEATNETS for Geothermal Network Performance

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification and validation process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study focuses on a validation of HEATNETS using results from TRNSYS. HEATNETS is not intended to replace other modeling tools, but this work demonstrates, via a comparison with an industry standard code, that HEATNETS can be a unique, high-level and rapid modeling tool for estimating the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control

District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. By exploiting the available thermal energy storage capacity, the MPC controller is capable of shifting up to 14% of the electricity consumption of the ETS from on-peak to off-peak hours. Therefore, the advanced control implemented in 5GDHC networks promotes coupling between the thermal and the electric sector, producing flexibility on the electric grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Grid Interactive Micro-Distributed Display Case

The goal of this project is to design, fabricate and validate the performance of an economically viable next-generation self-contained, refrigerated open vertical display case with integrated thermal storage that improves energy efficiency, enhances demand flexibility, uses an environmentally friendly refrigerant, improves human comfort

25 ENERGY STORAGE↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

Transactive HVAC Agent - Design and Performance Evaluation

Transactive energy systems are playing an increasingly important role in the efficient and reliable marketbased operation of the power grid. Since a significant portion of the residential building energy consumption is from heating ventilation and air conditioning (HVAC) systems, HVAC is one of the most promising resources to provide load flexibility. However, utilizing HVAC flexibility to provide various grid services while simultaneously maintaining consumer comfort and cost-reductions is challenging. This paper presents a design of a transactive HVAC agent (T-HVAC) to be used as a supervisory control for the HVAC system that can simultaneously ensure comfort and cost-reduction. In particular, the T-HVAC a) estimates HVAC thermal dynamics, b) ensures optimal operations of the HVAC system, and c) participates into markets, and d) implements a market-based control via controlling the thermostat temperature set-point. The T-HVAC performance is demonstrated through multiple scenarios and illustrations.

Demand flexibility, distribution system, HVAC, Tra↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Prime Time for Model-Predictive Control? Assessing the Technical and Market Readiness of Advanced Controls in Buildings

Despite three decades of extensive research and field testing that have consistently validated the benefits of Model Predictive Control (MPC) in building applications, the technology has seen limited market adoption. This paper evaluates the readiness of MPC for widespread deployment, showcases recent demonstrations and field tests across diverse building types, including residential, small commercial, large commercial, and campus settings. Our results demonstrate that MPC can optimize system operations to achieve load shifting, minimize curtailment of on-site generation, and reduce energy costs by up to 80 %, while maintaining or improving occupant comfort. We also show that MPC can effectively control large assets, such as MW-sized thermal storage systems, and respond to dynamic pricing signals. However, achieving scale remains difficult due to labor-intensive workflows, reliance on a “PhD-in-the-loop” for MPC design and maintenance, susceptibility to fragile data infrastructure, and persistent workforce education and acceptance barriers. To bridge this gap, we outline a transition from bespoke, labor intensive prototypes toward streamlined, segment-targeted deployment strategies that leverage model templates, semantic tools, and generative AI. By automating control configuration and reducing engineering effort, these recommendations provide a pathway for transforming successful research demonstrations into scalable, market ready solutions for MPC-based controls.

Pritoni, Marco↗

Using Synchronization as an Indicator of Controllability in a Fleet of Water Heaters

Peak reduction is an important concern that can help reduce the growing stress on distribution grid and allow to defer investments in new capacity. However, the growing concern for customer privacy and comfort may impact the performance of load control for residential devices. Water heaters represent a convenient way of reducing peak due to their ability to store thermal energy for future use. In this paper, we developed a methodology to help utilities gain more insight with respect to the impact of load control efforts for shaving peak with no necessary information about the water heaters except the device status (on/off). To this end, we use a fleet of water heaters in a controlled residential neighborhood in Atlanta, GA. Our findings show that convergence in device status can serve as a proxy for peak shifting during hours of the evening peak.

demand response↗

The hygrothermal performance of continuous and cavity wood fiber insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Hygrothermal Performance of Continuous and Cavity Wood Fiber Insulation

Wood fiber insulation is an emerging material known for its effective thermal performance and moisture management properties, making it a compelling alternative to conventional insulation. Its vapor permeability and ability to regulate indoor humidity contribute to improved building durability and comfort, particularly in varying climate conditions. The goal of this project is to characterize the hygrothermal performance of a new wood fiber insulation product line in U.S. climate zones and to facilitate the design and construction of the product in residential and light commercial building envelopes. This study investigates the thermal and hygrothermal performance of wood fiber insulation, both as continuous and cavity insulation. The research employs an exhaustive simulation task and an environmental chamber test of a wood fiber insulation. Over 400 simulations were conducted to study the hygrothermal characteristics of bio-based wood fiber insulation in various building envelope configurations across four climate zones. Environmental chamber tests were conducted under controlled winter conditions representative of Climate Zone 5A (Chicago, IL) to complement the simulation results. The chamber tests focused on the hygrothermal performance of the wood fiber insulation and the sheathing board to assess the insulation's ability to manage moisture in a cold climate. Simulation and environmental chamber test results were analyzed to evaluate the insulation's consistency and efficacy across diverse climatic zones. Results show that with a proper moisture control strategy, both cavity and continuous wood fiber insulation can work properly in both new and retrofit constructions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Micro-Environmental Control System (Final Report)

This project developed an innovative micro-environmental control system (µX) that enables office buildings to reduce energy used for heating and cooling by 15% or more. The µX is a compact, quiet, and ergonomic device that is designed to be installed under an office workstation; it is designed to maintain occupant comfort when room thermostat setpoints are incremented by 4°F or more (warmer in the summer and cooler in the winter) to save energy. When ambient room temperatures are outside of the usual comfort range, the µX maintains occupant comfort by delivering personalized cooling or heating locally to each office worker. The µX provides personalized cooling using a micro vapor compression system that includes a new high-performance micro-scroll compressor and a novel thermal storage unit. The vapor compression system operates at night to freeze a phase-change material (PCM). During the workday, the cooling stored in the PCM is released as a cool breeze of air to make occupants more comfortable. The micro-scroll compressor was developed specifically for this application; it is smaller than any of its type, minimizing the amount of power needed. In heating mode, the µX maintains occupant comfort using a foot heating mat with an infrared reflective box. The µX R&D project was conducted by Syracuse University in collaboration with United Technologies Research Center, Air Innovations, Bush Technical, and Cornell University. Over the course of the initial three-year project, the team developed and evaluated four versions of the unit, advancing the concept to Technology Readiness Level 6. The capabilities of individual proof-of-concept prototypes were verified in tests that were conducted with: 1) units in psychrometric chambers, 2) an instrumented manikin in a laboratory, and 3) human subjects in laboratories that simulate office environments. The tests verified that the µX prototypes met or exceeded all performance targets required to enable office buildings to reduce energy used for heating and cooling by 15% or more by maintaining occupant comfort when thermostat setpoints are incremented by 4°F or more.

25 ENERGY STORAGE↗

Thermal Management by Engineering the Alignment of Nanocellulose

One of the grand current research challenges is to improve the energy efficiency of residential and commercial buildings, which cumulatively consume more than 40% of the energy generated globally. In addition to improving the comfort of the inhabitants and mitigating the growing energy consumption problem, new building materials and technologies could provide a safe strategy for geoengineering to mitigate global climate change. Herein, recent progress in developing such advanced materials from nanocellulose, which is often derived from wood or even dirty feedstocks like waste, is reviewed. By using chemical and bacteria-enabled processing, nanocellulose can be used to fabricate broadband photonic reflectors, thermally super-insulating aerogels, solar gain regulators, and low-emissivity coatings, with potential applications in windows, roofs, walls, and other components of buildings envelopes. These material developments draw inspiration from advanced energy management found in nature, such as the nanoporous photonic structures that evolved in cuticles of beetles. Fabrication of such materials takes advantage of mesoscale liquid crystalline self-assembly, which allows for pre-designed control of cellulose nanoparticle orientations at the mesoscale. Finally, with the potential fully realized, such materials could one day transform the current energy-lossy buildings into energy plants on Earth and possibly even enable extraterrestrial habitats.

36 MATERIALS SCIENCE↗

Advancing Building Performance: Field Results of Thin-Glass Triple-Pane Window Demonstrations

To meet California and the nation's ambitious energy targets, energy use in the building sector must drop dramatically. Windows continue to be the lowest thermally performing envelope system in the nation's buildings, resulting in poor overall envelope performance and potential impacts to human health and comfort. Current best practice new window performance is typically met by double-pane low-solar-gain glazing. Thin-glass triple-pane windows are a highly promising next step forward in performance and have been deployed in two California multi-family sites to quantify field performance and building energy savings. The technology assessed offers the performance benefits of traditional triple-pane but with little increase in weight or cost, enabling incremental costs competitive with alternative energy reduction solutions for the building envelope. This paper covers a detailed investigation into the demonstration project and measured performance benefits of the windows after a full year of data collection.

Hart, Robert↗

Are Deep Energy Retrofits in Commercial Buildings Including Window Upgrades?

U.S. Commercial buildings account for about 20% of total U.S. energy consumption. Because the thermal performance of windows significantly affects building energy efficiency and HVAC system performance, best practice guidance often includes window and envelope improvements in conjunction with HVAC upgrades to optimize energy use and improve occupant comfort. It is an open question, however, regarding how often these best practices are implemented in the field. This paper aims to address that gap by conducting a literature review and a series of interviews with commercial building auditing and management professionals to explore the factors that drive window retrofits in commercial buildings. The paper explores a range of case studies from deep energy retrofits across the globe, comparing projects with and without window retrofits. The primary goals of this review are to: (1) provide data from real-world case studies illustrating the role of windows in deep energy renovations and HVAC upgrades, (2) conduct retrofit cost analyses for windows and high-performance HVAC systems and (3) offer insights into how window upgrade decisions are made and when they are implemented as part of deep energy retrofits. Most of the retrofit studies focused exclusively on high performance HVAC upgrades without considering how window upgrades might further enhance the overall energy efficiency of commercial buildings. Interviews with building industry experts shed light on the key factors influencing deep energy retrofit decisions and what factors tip the scales in favor of including window measures with more comprehensive retrofit projects.