Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Neutron Imaging dataset for SMC 2021 data challenge

The neutron radiography (nR) dataset provides information of the neutron events as measured for the Siemens star mask using the Timepix3 detector. The recordings consist of the position (x and y axes), the time-stamp, and time-over-threshold (TOT) values of each neutron event.

Peterson, Peter↗

First Measurement of Near-Threshold and Subthreshold 𝐽/𝜓 Photoproduction off Nuclei

We report on the first measurement of J/ψ photoproduction from nuclei in the photon energy range of 7 to 10.8 GeV, extending above and below the photoproduction threshold in the free proton of ∼ 8.2 GeV. The experiment used a tagged photon beam incident on deuterium, helium, and carbon, and the GlueX detector at Jefferson Lab to measure the semi-inclusive A(γ, e + e − p) reaction with a dilepton invariant mass M(e + e − ) ∼ m J/ψ = 3.1 GeV. The incoherent J/ψ photoproduction cross sections in the measured nuclei are extracted as a function of the incident photon energy, momentum transfer, and proton reconstructed missing light-cone momentum fraction. Comparisons with theoretical predictions assuming a dipole form factor allow extracting a gluonic radius for bound protons of p $\sqrt4⟨r^2⟩$ = 0.85 ± 0.14 fm. The data also suggest an excess of the measured cross section for sub-threshold production and for interactions with high missing light-cone momentum fraction protons. The measured enhancement can be explained by modified gluon structure for high-virtuality bound-protons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nucleon Decays into Light New Particles in Neutrino Detectors

Proton and neutron decays into light new particles 𝑋 can drastically change the experimental signatures and benefit from the complementarity of large water-Cherenkov neutrino detectors such as Super- and Hyper-Kamiokande and tracking detectors such as JUNO and DUNE. The proton decays 𝑝 → ℓ + ⁢𝑋 and 𝑝 → 𝜋 + ⁢𝑋 with 𝑚 𝑋 near phase-space closure lead to charged particles below the Cherenkov threshold, rendering them practically invisible in Super- and Hyper-Kamiokande but not in JUNO and DUNE, which are therefore uniquely positioned for these baryon-number-violating signatures despite their smaller size. As an additional signature, such nucleon decays in the Earth can produce a sizable flux of 𝑋 particles in underground detectors. We present a simple model in which nucleons decay into sub-GeV sterile neutrinos that subsequently decay through active-sterile neutrino mixing, with a promisingly large number of events in Super-Kamiokande even in the seesaw-motivated parameter space.

Baryon & lepton number symmetries↗

High Statistics Measurements of $ν_μ$ Charged-Current Single $π^{+}$ Production with Zero Pion Kinetic Energy Threshold in MINERvA

This Letter presents measurements of single-differential cross sections of $ν_μ$-induced charged-current 1 $π^{+}$ production on scintillator using the MINERvA detector at Fermilab. These measurements use traditional track-based pion reconstruction as well as pions identified solely via Michel electron decays, allowing measurement of kinetic energies from 0 to 350 MeV. In total, 91,843 events were selected with $W_{exp}$$<$ 1.4 GeV/c. Differential cross sections as a function of pion and muon kinematic variables are presented and compared with the predictions of several neutrino event generators. Overall, modern pion production models tend to agree with data at the ends of the kinematic regions probed, but are discrepant with the main regions of the phase space probed by up to 15% in muon observables and up to 20% in pion observables. No model describes any of the variables well, and this result highlights model areas that require improvement for the next generation of neutrino oscillation experiments.

Granados, E. [Guanajuato U.]↗

Measurement of the cross section of the Q=4.4398 MeV 12 C (n, n'γ) reaction from threshold to 16.5 MeV using γ and correlated n–γ detection

The Q=4.4398 MeV 12 C (n, n'γ) cross section was measured using a white incident neutron source through the detection of γ rays only and n–γ coincidences using a segmented liquid scintillator detector array. While the n–γ technique utilized here is more generally applicable to a wide variety of neutron scattering measurements, the γ-only technique was successfully applied to this reaction to exploit the precise time resolution and high efficiency of this detection system to yield results with unprecedented statistical precision and total uncertainties < 2 % from reaction threshold up to 16 MeV incident neutron energy, clearly resolving many features in this reaction that were previously not well known. The γ-only and n–γ results are consistent with each other for the majority of the incident energy range covered in this paper, thereby lending validation to the n–γ technique for future measurements, though significant disagreements are observed between both results and with the ENDF/B-VIII.0 nuclear data evaluation. These differences are particularly noticeable in the recently evaluated energy range below 6.5 MeV, and also near 14 MeV where a “sawtooth”-like feature is observed similar to that in other 12 C+n reaction channels. Finally, both γ-only and n–γ results are presented here with thorough covariance derivations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurements of attenuation and scattering properties of water-based liquid scintillator

Water-based liquid scintillator (WbLS) is a hybrid detector medium which has been proposed as a fill material for future large-volume rare event searches, including ν − detectors. This family of scintillating suspensions promises waterlike attenuation and scattering behavior, while offering scintillation light yield for sub-Cherenkov-threshold events. These features may allow for improved vertex and energy resolution, and concomitant improvements in background rejection and particle identification. While subscale measurements of light yield, timing and pulse-shape have been performed in several WbLS formulations, detailed measurements of the attenuation and scattering properties of WbLS remain a critical, unresolved step along the pathway to deployment. In pursuit of a better understanding of these parameters, a “long-arm” attenuation and scattering instrument has been developed at Lawrence Livermore National Laboratory, dubbed LASE (Livermore Attenuation and Scattering Experiment). Optical property measurements have been performed using LASE in DI water, Gd-water, WbLS and Gd-WbLS. Measurements of the optical properties of WbLS (1% LAB-PPO scintillator) provided by Brookhaven National Laboratory demonstrate an attenuation minimum of 4.87 × 10 − 4 ± 1.42 × 10 − 4 cm − 1 at 450 nm, while Gd-loaded WbLS (1% LAB-PPO scintillator, 0.1% Gd) demonstrated a minimum attenuation coefficient of 4.77 × 10 − 4 ± 1.27 × 10 − 4 cm − 1 at the same wavelength. Measurements of scattering in WbLS show a scattering coefficient of 3.39 × 10 − 4 ± 1.98 × 10 − 5 cm − 1 at the 450 nm attenuation minimum, while Gd-WbLS has a scattering coefficient of 2.8 × 10 − 4 ± 1.63 × 10 − 5 cm − 1 at that wavelength. These scattering and attenuation coefficients are significantly larger than measured for DI water at similar wavelengths ( 8.8 × 10 − 5 cm − 1 ± 3.8 × 10 − 5 attenuation at 430 nm, 2.2 × 10 − 5 ± 1.28 × 10 − 6 cm − 1 scattering). Though the WbLS attenuation and scattering coefficients measured are lower than the corresponding values published for ultrapure oils and LAB-PPO liquid scintillator, the material tested attenuates significantly more than water across the blue and green portions of the visible spectrum. This attenuation is markedly stronger at wavelengths under 430 nm. Published by the American Physical Society 2025

47 OTHER INSTRUMENTATION↗

Study of γ γ → γ ψ ( 2 S ) at Belle

Using 980 fb -1 of data at and around the Υ(nS)(n = 1, 2, 3, 4, 5) resonances collected with the Belle detector at the KEKB asymmetric-energy e+e- collider, the two-photon process γγ → γψ(2S) is studied from the threshold to 4.2 GeV for the first time. Two structures are seen in the invariant mass distribution of γψ(2S): one at M R 1 = 3922.4 ± 6.5 ± 2.0 MeV/c 2 with a width of Γ R 1 = 22 ± 17 ± 4 MeV, and another at M R 2 = 4014.3 ± 4.0 ± 1.5 MeV/c 2 with a width of Γ R 2 = 4 ± 11 ± 6 MeV; the signals are parametrized with the incoherent sum of two Breit- Wigner functions. The first structure is consistent with the X(3915) or the χ c2 (3930), and the local statistical significance is determined to be 3.1σ with the systematic uncertainties included. The second matches none of the known charmonium or charmonium like states, and its global significance is determined to be 2.8σ including the look-elsewhere effect. The production rates are Γ γγ B(R 1 → γψ(2S)) = 9.8 ± 3.6 ± 1.2 eV assuming (J PC , |λ|) = (0 ++ , 0) or 2.0 ± 0.7 ± 0.2 eV with (2 ++ , 2) for the first structure and Γ γγ B(R 2 → γψ(2S)) = 6.2 ± 2.2 ± 0.8 eV with (0 ++ , 0) or 1.2 ± 0.4 ± 0.2 eV with (2 ++ , 2) for the second one. Furthermore, the first errors are statistical and the second systematic, and λ is the helicity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exclusive J/$\psi$ detection and physics with ECCE

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been recommended as a reference design for the proposed Electron-Ion Collider (EIC) program. Here, this paper presents simulation studies of exclusive J/$\psi$ detection and selected physics impact results in EIC using the projected ECCE detector concept. Exclusive quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. Preliminary results estimate the excellent statistics benefited from the large cross section of J/$\psi$ photoproduction and superior performance of ECCE detector concept. The precise measurement of exclusive J/$\psi$ photoproduction at EIC will help us to more deeply understand nuclear gluon distributions, near threshold production mechanism and nucleon mass structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quartz fluorescence backgrounds in xenon particle detectors

It has been known for almost a decade that delayed photon noise with a power law time profile follows scintillation pulses in liquid xenon particle detectors. The origin of the noise has remained unknown, and in the past two years, has become an overwhelming background for low-threshold dark matter searches aimed at 𝒪⁡(10) GeV dark matter particle masses, as well as measurements of coherent neutrino-nucleus scattering of 8 B solar neutrinos. We have performed a comprehensive series of tests in a small liquid xenon cell at LBL, from which we conclude that the dominant component of this delayed photon noise is due to UV-induced fluorescence of quartz photosensor windows.

crystal optics↗

Neutron capture-induced nuclear recoils as background for CE$v$⁢NS measurements at reactors

Nuclear reactors represent a promising neutrino source for CE⁢v⁢NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CEv⁢NS signal for recoils ≲100 eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. Here, in this work we quantify the impact of this background and show that, for a measurement 10 m from a 1 MW reactor, the effective thermal neutron flux should be kept below ~7 × 10 –4 ⁢n/cm 2 s so that the CE⁢v⁢NS events can be measured at least at a 5⁢σ level with germanium detectors in 100 kg yr exposure time. This flux corresponds to 60% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CEv⁢NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

79 ASTRONOMY AND ASTROPHYSICS↗

Heralded Multiplexed High-Efficiency Cascaded Source of Dual-Rail Entangled Photon Pairs Using Spontaneous Parametric Down-Conversion

Deterministic sources of high-fidelity entangled qubit pairs encoded in the dual-rail photonic basis, i.e., presence of a single photon in one of two orthogonal modes, are a key enabling technology of many applications of quantum information processing, including high-rate, high-fidelity quantum communications over long distances. The most popular and mature sources of such photonic entanglement, e.g., those that leverage spontaneous parametric down-conversion (SPDC) or spontaneous four-wave mixing, generate an entangled (so-called continuous-variable) quantum state that contains contributions from high-order photon terms that lie outside the span of the dual-rail basis, which is detrimental to most applications. One often uses low pump power to mitigate the effects of those high-order terms. However, that reduces the pair generation rate, and the source becomes inherently probabilistic. We investigate a cascaded source that performs a linear-optical entanglement swap between two SPDC sources, to generate a heralded photonic entangled state that has a higher fidelity (to the ideal Bell state) compared to a free-running SPDC source. Furthermore, with the Bell swap providing a heralding trigger, we show how to build a multiplexed source, which despite reasonable switching losses and detector loss and noise, yields a fidelity versus success probability trade-off of a high-efficiency source of high-fidelity dual-rail photonic entanglement. We find, however, that there is a threshold of 1.5 dB of loss per switch, beyond which multiplexing hurts the fidelity versus success probability trade-off.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GEM detectors for the CMS endcap muon system: status of three new detector stations

The High-Luminosity LHC (HL-LHC, or Phase-2 LHC) will deliver proton-proton collisions at 5–7.5 times the nominal LHC luminosity, with an expected number of 140–200 pp-interactions per bunch crossing (Pile-up or PU). To maintain the performance of muon triggering and reconstruction under high background, the forward part of the Muon Spectrometer of the CMS experiment will be upgraded with Gas Electron Multipliers (GEM) and improved Resistive Plate Chambers (iRPC) detectors. A first GEM station (GE1/1) was installed during Long Shutdown 2 (LS2, 2019–2021), a 2 nd station (GE2/1) of Triple-GEM detectors will be installed in winter 2023–24 and 2024–25, while a new 6-layer station (ME0) will be installed in the third Long Shutdown (LS3, 2026–2028). GE11 is considered an early Phase-2 upgrade as it will reduce the p T threshold by combining GEM and Cathode Strip Chamber (CSC) hits in the forward muon system at twice the LHC design luminosity ($\mathcal{L}$ = 2 · 10 34 cm -2 s -1 , 50 PU). After a successful start of Run-3 in 2022, with almost 40 fb -1 collected, the commissioning of the GE1/1 detector is nearly complete. Most chambers are operated stably with an efficiency in excess of 95%, next being the demonstration of the combined CSC-GEM trigger in 2023. The lessons learnt with the first large-area GEM station have lead to improvements in detector and electronics design for the Phase 2 detectors GE2/1 and ME0. This proceeding will discuss the progress made since last MPGD Conference (MPGD 2019), discussing the commissioning and early performance of GE1/1; the design improvements and start of construction of GE2/1; and the R&D currently ongoing for ME0.

47 OTHER INSTRUMENTATION↗

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT’s Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe an on-beam excess of 20.6$^{+7.1}_{−6.3}$ counts with a total exposure of 10.22 GWhkg, and we reject the no-CEvNS hypothesis with 3.9⁢𝜎 significance. The result agrees with the predicted standard model of particle physics signal rate within 2⁢𝜎.

Electroweak interaction↗

Discriminator Threshold Study for Scint 1

During electronics testing at NSRL, the fluence/spill is recorded from the QC1 chamber. This chamber, which is a permanent fixture on the NSRL beamline, requires calibration from an external radiation detector that can measure ion flux directly. A 1.0 × 1.0 × 0.5 cm 3 scintillator is used at the testing location to calibrate all NSRL beams for electronic experiments. A calibration factor is derived by comparing the ions observed by the scintillator and QC1 during an exposure of at least 10 5 scintillator counts or total ions.

43 PARTICLE ACCELERATORS↗

MeV Scale Physics in MicroBooNE

This thesis presents the reconstruction and measurement of low-energy electromagnetic activity with beam neutrino interactions within the MicroBooNE Liquid Argon Time Projection Chamber (LArTPC). LArTPCs have proven to be excellent detectors to measure neutrino interaction cross sections and are being used to perform precision measurements of neutrino oscillation parameters. The work presented in this thesis has demonstrated unprecedentedly low, sub-MeV energy thresholds that have increased sensitivity of LArTPCs to detect neutrino interactions from core collapse supernovae and Muon Decay at Rest (µDAR). In addition, such low thresholds have also increased measurement sensitivity for interactions from Beyond the Standard Model (BSM) candidates such as millicharged particles and nuclear and electron recoils from dark matter candidate particles. On the reconstruction side, this work has established an energy resolution of 6.3% for electromagnetic activity i the 0-5 MeV energy range within the MicroBooNE LArTPC. Additionally this work presents the quantitative analysis of the low-energy activity emanating from G-10 support ribs in MicroBooNE and discusses how such activity could be a problematic source of background for low-energy physics analyses in future neutrino detectors such as the Deep Underground Neutrino Experiment (DUNE).

Bhat, Avinay↗

Correlation of Processing and Structure in an Ethylene‐Glycol Side‐Chain Modified Polythiophene via Combined X‐Ray Scattering and 4D Scanning Transmission Electron Microscopy

The results of a combined grazing incidence wide-angle X-ray scattering (GIWAXS) and 4D scanning transmission microscopy (4D-STEM) analysis of the effects of thermal processing on poly(3[2-(2-methoxyethoxy)ethoxy]-methylthiophene-2,5-diyl) are reported, a conjugated semiconducting polymer used as the active layer in organic electrochemical transistor devices. GIWAXS provides a measure of overall crystallinity in the film, while 4D-STEM produces real-space maps of the morphology and orientation of individual crystallites along with their spatial extent and distribution. The sensitivity of the 4D-STEM detector allows for collection of electron diffraction patterns at each position in an image scan while limiting the imparted electron dose to below the damage threshold. In conclusion, the effects of heat treatment on the distribution and type of crystallites present in the films is determined.

36 MATERIALS SCIENCE↗

Test of lepton flavor universality with measurements of 𝑅⁡(𝐷 + ) and 𝑅⁡(𝐷* + ) using semileptonic 𝐵 tagging at the Belle II experiment

We report measurements of the ratios of branching fractions ℛ⁡(𝐷 (*)+ ) = ℬ⁡($\bar{𝐵}$ 0 → 𝐷 (*)+ ⁢𝜏 −⁢ $\bar{𝜈}$ 𝜏 )/ℬ⁡($\bar{𝐵}$ 0 → 𝐷 (*)+ ⁢ℓ − $\bar{𝜈}$ ℓ ), where ℓ denotes either an electron or a muon. These ratios test the universality of the charged-current weak interaction. The results are based on a 365 fb −1 data sample collected with the Belle II detector at the SuperKEKB 𝑒 + ⁢𝑒 − collider, which operates at a center-of-mass energy corresponding to the ϒ⁡(4⁢𝑆) resonance, just above the threshold for $𝐵\bar{𝐵}$ production. Signal candidates are reconstructed by selecting events in which the companion 𝐵 meson from the ϒ⁡(4⁢𝑆) → $𝐵\bar{𝐵}$ decay is identified in semileptonic modes. The 𝜏 lepton is reconstructed via its leptonic decays. We obtain ℛ⁡(𝐷 + ) = 0.418$^{+0.075}_{−0.073}$⁢(stat)$^{+0.049}_{−0.056}$⁢(syst) and ℛ⁡(𝐷 *+ ) = 0.306$^{+0.035}_{−0.033}$⁢(stat)$^{+0.016}_{−0.018⁢}$(syst), which are consistent with world average values. Accounting for the correlation between them, these values differ from the Standard Model expectation by a collective significance of 1.7 standard deviations.

bottom quark↗